Utd2025 Series User Manual
Utd2025 Series User Manual
Page 1 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Table of Contents
Page 2 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Computer Windows 2000/XP/Vista, 128 MB RAM, 16x CD-ROM or better (Vista users
please refer to its individual hardware requirements), SVGA display or better.
Connection cable USB A-B cable or RJ45 net cable or GPIB communication cable.
Your UTD2025_3025 Series Digital Storage Oscilloscope (“Oscilloscope”) comes with an oscilloscope
communication and control software (contained in the CD-Rom supplied with your oscilloscope).
Alternatively, you can download the software online :
File name : UTD2025_3025 oscilloscope communication and control software.
Installation :
Step one : Insert the CD-rom supplied with your oscilloscope into the CD-Rom drive of the computer.
Wait for the system to read and find the oscilloscope communication and control software
contents (Fig. 1-1).
Fig 1-1
Note : 1. The installation pack downloaded online must be unzipped before application.
2. The software supports Windows 2000, Windows XP and Vista operating systems. On Vista only
USB2.0 communication protocol is supported.
Step two : Double left click the mouse to run the oscilloscope communication and control software
installation as shown in Fig 1-1.
The installation wizard for the oscilloscope communication and control software will pop up, as
shown in Fig. 1-2.
Page 3 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 1-2
Step three : Read the prompt in Fig 1-2 then click the [NEXT (N)] button to enter the next step, as shown in
Fig 1-3.
Fig 1-3
Step four : In Fig 1-3, enter your user name and company name, then click the [NEXT (N)] button to enter
the next step, as shown in Fig 1-4.
Page 4 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 1-4
Step five : In Fig 1-4, click the [CHANGE (H) …] button to specify the installation path of the software,
then click [NEXT (N)]. You can also click [NEXT (N)] directly to use the default path. Enter
the screen shown in Fig 1-5.
Fig 1-5
Step six : In Fig 1-5, after confirming the message is correct, click [NEXT (N)] to enter the front page for
automatic installation, as shown in Fig 1-6.
Page 5 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 1-6
Step seven : When automatic installation is complete and the box shown in Fig 1-7 pops up, click the
[FINISH (F)] button. Your oscilloscope communication and control software is now
successfully installed on your computer and ready for use.
Fig 1-7
To return to the previous installation guide interface, click [BACK (B)] on any installation guide page.
To stop installation, press [CANCEL (C)] on any installation guide page.
Page 6 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
When installation of the oscilloscope communication and control software is complete, you can run it on your
computer in two ways.
1. When installation of the oscilloscope communication and control software is complete, an short-cut icon is
automatically created on the computer desktop, as shown in Fig 1-8. To run the software, simply double left
click the icon in Fig 1-8 with your mouse.
Fig 1-8
2. Alternatively, you can run the software by going through START Programme Digital storage
oscilloscope DSO, as shown in Fig 1-9.
Fig 1-9
Page 7 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
If you are using the oscilloscope’s USB device port for software communication and control, the USB driver must
be installed after installation of the oscilloscope communication and control software is complete. Follow the
steps below :
1. There is a USB device port on the rear panel of your UTD2025_3025 Series Digital Storage Oscilloscope.
With the supplied USB A-B cable, you can connect the USB device port to the USB Host port of the
computer and obtain power supply for the oscilloscope.
2. After checking that connection and power supply are normal, power on the digital storage oscilloscope.
When the operation status screen appears, a prompt will appear at the right bottom corner to indicate “New
hardware DSO detected”, as shown in Fig 1-10.
Fig 1-10
Next, an icon will be created for the “New hardware DSO detected”, as shown in Fig 1-11.
Fig 1-11
Then a “hardware update wizard” dialog box will pop up on the desktop, as shown in Fig 1-12.
Fig 1-12
Page 8 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 1-13
4. As shown in Fig 1-13, the hardware installation wizard of your digital storage oscilloscope begins automatic
searching and installing the USB driver for the oscilloscope communication and control software. When
installation is complete the dialog box shown in Fig 1-14 pops up.
Fig 1-14
Page 9 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Page 10 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Virtual display
Range indicator
Channel status
Virtual control
panel
Real-time control
Fig 2-1
Page 11 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
1. Document
Load : This means saving the oscilloscope communication and control software to the computer hard
disk or other storage media, or save it in a waveform file on any mobile storage media by using
the long save function of the oscilloscope save menu, and then open the saved waveform on the
virtual display panel with the “Load” feature.
Note : When storing a waveform from the digital storage oscilloscope to a mobile USB device,
storage mode of the oscilloscope must be set to “long storage” to load the waveform onto the
computer software. To set “long storage”, use the STORAGE button on the front panel of the
oscilloscope : STORAGE Type : WAVEFORM NEXT Disk (USB) Storage
depth (Long storage).
Save : This means saving the waveform currently on the virtual display panel to a computer or other
storage equipment. Select “Document” “Save” and save it on the hard disk or mobile external
hard disk in *.dat format. Assign any file name you like.
Record : Enable the “data transmission” function and select “Document” “Record”. A prompt box
shown in Fig 2-2 will pop up on the virtual display panel and recording of the virtual display
waveform begins. The recording prompt box shows the current waveform recording progress.
To pause recording, simply click the “pause” button. To resume, click the “continue” button and
recording will resume from the point where it was paused.
The dialog box in Fig 2-3 appears when you close the waveform recording function or recording
has reached the maximum number of data screens. Click “YES” in Fig 2-3 to save it in *.dat
format on the computer hard disk or other storage device. If you wish to abandon recording,
press “NO” as shown in Fig 2-3. The waveform recording function can record up to 2000
screens of data.
Page 12 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Dynamic
playback : Select “Document” “Playback” “Dynamic playback”. The waveform playback loading
interface in Fig 2-4 will pop up. Specify the search area to locate the storage path of the
recorded waveform, select the recorded waveform document you require, then click the [Load]
button. The recorded waveform will be played continuously on the virtual display with the
current playback progress.
Static
playback : Select “Document” “Playback” “Static playback”. The waveform playback loading
interface in Fig 2-4 will pop up. Specify the search area to locate the storage path of the
recorded waveform, select the recorded waveform document you require, then click the [Load]
button. Fig 2-5 will now appear. By using the “manual playback” button, you can play back the
recorded waveform screen by screen. Alternatively, enter the required screen number in the
screen number display field and press “ENTER”. Your specified screen will be displayed. To
close the static playback function, click the “close static playback” button.
Fig 2-5
Page 13 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Waveform : The preview waveform is the last screen of waveform data uploaded from the oscilloscope to
the communication and control software after “data transmission” is completed, or the
waveform on the computer hard disk or mobile USB device which is downloaded to the
software with the “load” function.
Depending on the number of channels working at the time of data transmission, you can select
the channel mode on the waveform preview interface with the selection function of the menu.
When uploading with two channels, you can select “single channel” (CH1, CH2), “two
channels” (CH1 & CH2, CH1 & Math, CH2 & Math) or “all” to preview the waveform. To quit
the preview screen, click the exit button.
Interface : The preview interface is the last screen uploaded by the oscilloscope to the computer after the
“transmission interface” is closed.
Printing : When “data transmission” is complete, select “Document” “Print” to print the waveform or
the interface.
Waveform : The printed waveform is the last screen of waveform data uploaded from the oscilloscope to the
communication and control software after “data transmission” is completed, or the waveform on
the computer hard disk or mobile USB device which is downloaded to the software with the
“load” function.
Interface : The print interface is the last screen uploaded by the oscilloscope to the computer after the
“transmission interface” is closed.
Exit : After the “data transmission” or “transmission interface” task is complete, select “Document”
“exit” to quit the oscilloscope communication and control software.
2. Functions
All sub-menus under the FUNCTION menu can be operated only when the “data transmission” or “transmission
interface” task is complete.
◆ Mathematics functions : When this menu is clicked, a mathematics function dialog box will pop up to enable
“mathematics selection” or “FFT mathematics”, as shown in Fig 2-6.
Page 14 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 2-6
Mathematics selection : You can select the mathematical relation between signal sources A and B. There
are four mathematical relations : +, -, x, ÷.
Signal source selection : There are A and B signal sources. You can set them up as CH1 or CH2 channel
signals respectively.
FFT function selection : You can switch between “Rectangle”, “Hanning”, “Hamming” and “Blackman”.
◆ Remote control : You can operate the digital storage oscilloscope on remote control with the
communication and control software. In the remote control mode, the computer screen will display a virtual
instrument control panel which is fundamentally the same as the oscilloscope control panel, as shown in
Fig 2-7.
Page 15 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Virtual control
panel
Fig 2-7
The sign of every button or knob on the virtual control panel is identical to that on the oscilloscope control panel.
You can click the same buttons to operate the corresponding functions. To use the virtual control panel efficiently,
you must be familiar with all function menus as well as the current status of the oscilloscope.
Note : You can only operate the digital storage oscilloscope with the virtual control panel. Waveform observation
or screen display function is not available. You cannot operate the “remote control” and “transmission
interface” tasks simultaneously.
◆ Data table : This shows the function relation between the voltage and time of the sampling point of the
waveform currently on display, i.e. V=F(t).
Channel
indication
Fig 2-8
Page 16 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Select the
path
Enter the
document
Fig 2-9
◆ Parameter measurement : This shows all the parameter values of the waveform currently on display in the
selected channel.
Start/pause transmission : “Start transmission” means beginning to transmit data. “Pause transmission” means
stopping transmission.
Fig 2-10
Page 17 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Single refresh : This is a single waveform trigger. The acquired waveform display is stored on the display
panel of the virtual control panel.
Waveform time interval setup : To set up the time interval for waveform refresh.
4. Help
This menu shows the version of the oscilloscope communication and control software.
Channel status : This indicated the current control status of the digital storage oscilloscope.
During “data transmission”, this status bar indicates the current control status of the oscilloscope. This bar
changes with the actual control status of the oscilloscope but you cannot control the current status of the
oscilloscope with this bar.
CH1 : Coupling method (DC, AC, GND); Bandwidth suppression (On, Off); Filter type (low-pass,
high-pass, band-pass, band-stop); Digital filter (when the indicator light comes on the function is ON, when
the indicator light goes off the function is OFF); Reverse (when the indicator comes on the function is ON,
when the indicator light goes off the function is OFF); Probe (1X, 10X, 100X, 1000X).
CH2 : Coupling method (DC, AC, GND); Bandwidth suppression (On, Off); Filter type (low-pass,
high-pass, band-pass, band-stop); Digital filter (when the indicator light comes on the function is ON, when
the indicator light goes off the function is OFF); Reverse (when the indicator light comes on the function is
ON, when the indicator light goes off the function is OFF); Probe (1X, 10X, 100X, 1000X).
Interpolation : Yes; No
Real-time Control : Equipment selection (USB, LAN, GPIB); ON/OFF (when the indicator light comes on
the function is ON, when the indicator light goes off the function is OFF); Data transmission (when the
indicator light comes on the function is ON, when the indicator light goes off the function is OFF);
Transmission interface (when the indicator light comes on the function is ON, when the indicator light goes
off the function is OFF).
Page 18 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Mathematics function : Select mathematics functions with the function menu in the menu bar.
Auto Refresh : Set up the refresh time interval with the waveform refresh menu in the menu bar.
Operation mode
Menu :
Function selection : Saving and exiting screen
Save : Select “Single” as in Fig 2-11 to save the waveform and screen on the virtual
display panel in *.bmp format on the computer hard disk or mobile USB device.
Exit : Quit the remote control transmission interface mode.
Serial : When “serial” is selected, the waveform on the virtual display panel will be updated in real
time and in synchronization with the waveform stored by the oscilloscope. In this mode,
data volume is sizeable and control response is slower.
Single : When “single” is selected, the waveform on the waveform display screen is not displayed in
synchronization with the waveform stored by the oscilloscope. In this mode, data volume is
limited and control response is faster.
Close : Close the transmission interface and return to the main control panel (Fig 2-1).
Page 19 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
To enjoy optimal software performance, we recommend you to read the oscilloscope user manual and this chapter
to familiar with application.
After installing the software and driver properly, connect the cable to the USB A-B communication port. Power on
the oscilloscope and activate the software. The software control panel shown in Fig 3-1 will appear on your
computer screen.
Fig 3-1
Page 20 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
1. Select “USB” in the equipment selection option on the virtual control panel.
2. Click the [Equipment ON/OFF] button to turn it “ON”. The indicator light is green. When the button is
turned “OFF”, the indicator light will go off, as shown in Fig 3-2.
3. Click the [Data Transmission] button to turn it on. When the indicator light comes on the function is ON.
When the indicator light goes off the function is OFF, as shown in Fig 3-3. When data transmission is on,
you can operate the digital storage oscilloscope with the buttons and knobs on the control panel. The
parameters and setups of the virtual control panel will change accordingly.
4. When data transmission is complete, Click the [Data Transmission] button again to turn it off.
During data transmission, you cannot operate the oscilloscope with the software. The function keys on the
virtual control panel are disabled but they continue to indicate the current status of the oscilloscope.
Page 21 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 3-4
6. On the virtual control panel in Fig 3-4, you can operate your oscilloscope with different buttons as instructed
by the oscilloscope user manual. Select “Serial” on the above screen so the oscilloscope can transmit the
oscilloscope screen to the virtual display panel in real time. When “Single” is selected, the virtual display
panel will only show the first transmission interface.
Note : In serial mode when transmission volume is high, response of the software is relatively slow. In single
mode, however, response is quick as there is only one transmission and data volume is low.
Note : The “data transmission”, “remote control” and “transmission interface” functions cannot be operated
simultaneously.
Page 22 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
With the optional UT-M01 (for UTD2025 models) or UT-M05 (for UTD3025 models) Ethernet module, you can
operate the oscilloscope through the LAN interface as follows :
1. Select “LAN” in the equipment selection option on the real-time control panel.
2. When “LAN” is selected, the dialog box in Fig 3-5 will pop up.
Fig 3-5
Enter the DSO IP address in this box. The IP addresses set in the software and the communicated oscilloscope
must be the same, otherwise communication between the oscilloscope and the software cannot be established.
Please refer to the oscilloscope user manual for operation instructions. Access sub-menu page 3 by pressing
[UTILITY] LAN on the oscilloscope control panel for TCP/IP protocol setup. You should set up the IP address,
netmask and default gateway in LAN. In the same network, the IP address of every individual digital storage
oscilloscope is unique and must not conflict with the IP address of any other equipment (in-network IP addresses).
3. For other operation instructions refer to steps 2, 3, 4, 5, 6 and 7 for “USB interface controls” in this chapter.
Note : When using the LAN interface, you can operate the oscilloscope by remote control via LAN or the Internet.
Mapping feature of the router must be enabled and the public network address of your company should provided.
Page 23 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
The GPIB port is a dedicated interface module of UTD3025 Series Digital Storage Oscilloscopes. After installing
the communication and control software, you can carry out system operation and control your oscilloscope
through the GPIB interface. You can create an automatic testing system simply, quickly and efficiently, and carry
out testing and measuring.
With the optional UT-M02 extension module, you can operate your UTD3025 oscilloscope through the GPIB
interface as follows :
1. Select “GPIB” in the equipment selection option on the real-time control panel.
2. When “GPIB” is selected, the dialog box in Fig 3-6 will pop up.
Fig 3-6
Enter the GPIB device address in this box (range : 1-30). The GPIB device addresses set in the software and the
communicated oscilloscope must be the same, otherwise communication between the oscilloscope and the
software cannot be established.
Access sub-menu page 3 by pressing [UTILITY] GPIB on the oscilloscope control panel for GPIB device
address setup.
There must not be two identical GPIB device addresses on one GPIB main line.
3. For other operation instructions refer to steps 2 and 3 for “USB interface controls” in this chapter.
Note : When using the GPIB interface, the “transmission interface” feature is disabled.
Page 24 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
SCAN prompt : SCAN will perform single transmission. Please carry out single refresh. Continue?
Are you sure you want to exit Virtual Instrument? A prompt to ask you if you wish to close the software.
4.2 Troubleshooting
1. If the system prompts you to check serial or USB configuration when you enter [Equipment ON/OFF], take
the following steps :
Check whether oscilloscope ports match the communication and control software setups.
After carrying out the above checks, restart the software and oscilloscope to continue operation.
2. If you are unable to update the software driver, take the following steps :
Right click the box on your computer desk-top as shown in Fig 4-1 to activate the right-click menu in Fig
4-2.
Page 25 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 4-3
Fig 4-4
Page 26 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual
Fig 4-5
In Fig 4-5, delete “digital storage oscilloscope” in “Universal serial main line controller” to restart the
oscilloscope. Select automatic driver update to complete the update process.
Note : When the communication and control software is communicating with the digital storage oscilloscope,
you cannot connect both the network cable and USB device cable to the oscilloscope ports, and do not
remove the cable to disconnect during communication.
Page 27 of 27
Communication & Control Software for UTD2025_3025 Series Oscilloscopes User Manual