0% found this document useful (0 votes)
86 views

PHMI5

The document discusses licensing options for Premium HMI 5 human-machine interface (HMI) software. It lists various license codes for the WinCE and Win32 versions of the software in Basic, Advanced, and Pro editions. Notes indicate that the first order of a runtime license requires a development tool license and details compatible operating systems for the development kit. Feature comparisons are provided between the Basic and Advanced editions.

Uploaded by

Javier Solis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views

PHMI5

The document discusses licensing options for Premium HMI 5 human-machine interface (HMI) software. It lists various license codes for the WinCE and Win32 versions of the software in Basic, Advanced, and Pro editions. Notes indicate that the first order of a runtime license requires a development tool license and details compatible operating systems for the development kit. Feature comparisons are provided between the Basic and Advanced editions.

Uploaded by

Javier Solis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

HMI & Cloud Solutions software

WinCE
Industrial Automation - Products & Configurations
Premium HMI 5 WinCE BASIC
CODE
> see note 1

footprint 

0SW74410 Premium HMI 5 Win CE runtime licence for PRELOAD on ASEM SYSTEMS 20MB

0SW74411 Premium HMI 5 Win CE runtime licence for AFTER SALES activation on ASEM SYSTEMS 20MB

Premium HMI 5 WinCE ADVANCED


CODE
> see note 1

footprint 

0SW74420 Premium HMI 5 Win CE runtime licence for PRELOAD on ASEM SYSTEMS 20MB

0SW74421 Premium HMI 5 Win CE runtime licence for AFTER SALES activation on ASEM SYSTEMS 20MB

0SW74423 Premium HMI 5 Win CE UPGRADE license from BASIC to ADVANCED 20MB

Premium HMI Studio


CODE
> see note 2

footprint 

0SW73601 Premium HMI Studio development tool licence 500MB

NOTES
1: With the first order of a Premium HMI 5 runtime license, one development tool Premium HMI Studio license must be sold.
2: Development kit can be installed with the following operating systems: Windows 7 32/64bit, Windows XP/2000, Windows XP Embedded, Windows 2003 server.
Application and help-online available in: Italian, English, German and Spanish

Premium HMI 5 Win CE runtimes BASIC ADVANCED

Minimum system memory 512MB 512MB

RealTime DB (max, byte) 1.024 8.192

OPC UA Client *  

OPC UA Server ** 

Communication drivers Max 2 Max 4

XAML Vector Graphics rendering (WEC7 and greater)  

Swipe Gesture Recognition for page change  

Multitouch *  

Alarms (max) 1.024 4.096

Alarm notification (SMS, E-Mail) 

SMS notification via SMPP protocol 

Recipes / Data Logger (CSV/XML)  

Recipes / Data Logger (ODBC) Max 2 unlimited

Data analysis  

Historical and Real Time Trends viewers  

Text Reports  

Graphic Reports and Alarm Statistics  

Security management in 1024 levels with user and groups  

CFR21 Part 11 tools  

Runtime users management  

Unicode multiple languages  

VBA Scripting multithreading  

VBA Interface for communication drivers  

Networking Client/Server  

Web Client (Java Applet and HTML5) Max 4 clients

Multicore processors support *  

Premium HMI Mobile 

* The function is available only in version 5.0.1181.xx or greater

** The function is available only in version 5.0.1183.xx or greater

2020.01 pg. 1 / 3 Rel.00


HMI & Cloud Solutions software

Win32
Industrial Automation - Products & Configurations
Premium HMI 5 Win32 BASIC
CODE
> see note 1
footprint 

0SW74430 Premium HMI 5 Win 32 runtime licence for PRELOAD on ASEM SYSTEMS 40MB

0SW74431 Premium HMI 5 Win 32 runtime licence for AFTER SALES activation on ASEM SYSTEMS 40MB

Premium HMI 5 Win32 PRO


CODE
> see note 1
footprint 

0SW74440 Premium HMI 5 Win 32 runtime licence for PRELOAD on ASEM SYSTEMS 40MB

0SW74441 Premium HMI 5 Win 32 runtime licence for AFTER SALES activation on ASEM SYSTEMS 40MB

0SW74443 Premium HMI 5 Win 32 UPGRADE license from BASIC to PRO 40MB

Premium HMI 5 Win32 ADVANCED


CODE
> see note 1
footprint 

0SW74450 Premium HMI 5 Win 32 runtime licence for PRELOAD on ASEM SYSTEMS 40MB

0SW74451 Premium HMI 5 Win 32 runtime licence for AFTER SALES activation on ASEM SYSTEMS 40MB

0SW74453 Premium HMI 5 Win 32 UPGRADE license from BASIC to ADVANCED 40MB

0SW74454 Premium HMI 5 Win 32 UPGRADE license from PRO to ADVANCED 40MB

Premium HMI Studio


CODE
> see note 2
footprint 

0SW73601 Premium HMI Studio development tool licence 500MB

NOTES
1: With the first order of a Premium HMI runtime license, one development tool Premium HMI Studio license must be sold.
The minimum configuration as a footprint of about 1GB and it is composed by Windows Embedded Standard 2009 + .NET + PHMI Win32 runtime. For this
configuration minimum Compact Flash is 2GB.
2:
Development kit can be installed with the following operating systems: Windows 7 32/64bit, Windows XP/2000, Windows XP Embedded, Windows 2003 server.
Application and help-online available in: Italian, English, German and Spanish

Premium HMI 5 Win 32 runtimes BASIC PRO ADVANCED


Minimum system memory 1GB 1GB 2GB
RealTime DB (max, byte) 2.048 2.048 4.096
OPC UA Client *   
OPC UA server **  
ODBC Realtime I/O Link  
Trace DB (Audit trail)  
Communication drivers Max 2 Max 2 Max 4
XAML Vector Graphics rendering (WEC7 and greater)   
Swipe Gesture Recognition for page change   
Objects' Drag&Drop   
Public Symbols (Symbols with hierarchy)  
Power Templates (Symbols with embedded VBA script)  
Style Source Management in Symbols  
Grid, combo box, list box, check box, tab objects  
Synapses  
Objects’ Alias Management  
Multitouch *   
Alarms (max) 2.048 2.048 4.096
Historical Management (ODBC)  
Alarm notification (SMS, E-Mail) 
Comment on ACK alarm  
Recipes / Data Logger (CSV/XML)   
Recipes / Data Logger (ODBC)  
Windows users (Active Directory integration) 
Data analysis  
Historical and Real Time Trends viewers   
Text Reports   

with limitations (access


Graphic Reports and Alarm Statistics  
only through IMDB)

Screen Navigation editor  


Security management in 1024 levels with user and groups   
CFR21 Part 11 tools  
Runtime users management   
Unicode multiple languages   
VBA Scripting multithreading Max 2 scripts unilimited unlimited
VBA Interface for communication drivers  
Script’s IntelliSense Tags  
Networking Client/Server   
Father/Child Projects  
Web Client (Java Applet and HTML5) Max 2 clients
Multicore processors support *   
Premium HMI Mobile 
* The function is available only in version 5.0.1181.xx or greater
** The function is available only in version 5.0.1183.xx or greater

2020.01 pg. 2 / 3 Rel.00


HMI & Cloud Solutions software

Communication driver
Industrial Automation - Products & Configurations
Premium HMI
Driver/protocols compatibile list
Operating System
Interface
Protocols / devices WinCE Win32/64
Serial Ethernet HW add-on ARM x86 x86
Codesys, ELAU, KEB, PARKER,…  (1)  
Rockwell DF1 and Data Highway    
Rockwell EtherNet/IP    
Rockwell EtherNet/IP Micro800    
Applicon cards Applicon Cards 
B&R PVI with protocol INA2000 (2)     
B&R TCP (3)    
BACNET IP  
Beckhoff Twincat (ADS protocol) (4)    
CANOpen Master NETcoreX CANOpen Master  
CANOpen Slave only PDO NETcoreX CANOpen Slave  
KNX (EIBUS Konnex)   
ELAP    
FATEK TCP    
GE FANUC SNP-X   
GE SRTP2    
Hilscher DPM in PROFIBUS, CANOPEN CIF cards  
Hilscher MPI CIF card  
Hilscher NETLINK   
Hilscher NETX MPI NETCoreX MPI  
Hilscher NETX PROFIBUS Slave NETCoreX PROFIBUS SLAVE  
Hitachi PLC serie H  
IBH Softech    
KEB DIN66109-II    
LENZE LECOM AB    
LonWorks   
Mitsubishi MELSEC A  
Mitsubishi MELSEC FX    
Mitsubishi MELSEC Q     
Mistubishi FX3U TCP  
Modbus RTU Master / Slave    
Modbus TCP IP    
Moeller SUCOM    
OMRON FINS     
OMRON Host Link    
OMRON EtherNET/IP    
PANASONIC FP MEWTOCOL     
ROBOX    
SAIA via SCOMM DLL   
SAIA S-BUS     
SCHNEIDER UNITELWAY SLAVE    
SIEMENS MPI PC ADAPTER    
SIEMENS S5 CPU  RS-232 to Current Loop Converter   
SIEMENS S5 DK3864R    
SIEMENS S7 200 PPI    
SIEMENS S7 300/400 MPI (5)   (6)
SIEMENS S7 TCP 300/400    
SIEMENS CP5611, 5613, 5614, 5412
SIEMENS SAPI S7  and SIMATIC NET

SIEMENS SIMOTION    
SIEMENS S7 TIA (7)    
SIEMENS S7 Profinet (8)    

1. Requires CoDeSys Gateway running on controller side


2. Requires PLC communication support program supplied by ASEM
3. PVI communication libraries supplied by B&R are mandatory
4. ADS communication libraries supplied by Beckhoff are mandatory
5. Ethernet-MPI Gateway" function, local or remote using UBIQUITY, supported ONLY with PHMI4
6. Only OT600/HMI600/Smartbox
7. Supports the variable import from TIA Portal and communication S7-1200 / S7-1500 controllers via absolute addressing (no symbolic)
8. Supports the variable import from TIA Portal and communication S7-1200 / S7-1500 controllers via symbolic addressing

2020.01 pg. 3 / 3 Rel.00

You might also like