Solenoid valve
Types EV220B and EV220BW
Features
• For water, steam, oil, compressed air and
gases
• Ambient temperature: Up to 80 °C
• Coil enclosure: Up to IP67
• Water hammer damped
• Built in filter for protection of pilot system
• Adjustable closing time available
• EV220B 15-50 NC and NO brass version for
neutral liquids and gasses
• EV220B 15-50 NC DZR brass version for
neutral and slightly aggressive liquids and
gases
• EV220B 15-50 NC Stainless Steel version for
neutral and aggressive liquids and gases
• EV220BW 40-50 NC+NO EPDM and WRAS for
drinking water
AI236986444669en-001101
Solenoid valve, Types EV220B 15-50 and EV220BW 40-50
1 Portfolio overview
2 Functions
Figure 1: Function, NC
1. Coil
2. Armature spring
3. Valve plate
4. Pilot orifice
5. Diaphragm
6. Main orifice
7. Equalizing orifice
7
Figure 2: Function, NO
1. Coil
2. Armature spring
3. Valve plate
4. Pilot orifice
5. Diaphragm
6. Main orifice
7
7. Equalizing orifice
3 Applications
It is recommended to use a filter in front of the valve. Recommended filter 50 mesh (297 microns).
Figure 3: Filter
32U1460
Danfoss
In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The
valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up.
ON
32U9100
Danfoss
OFF
24h
To minimize scaling, and corrosion attack it is recommended that the water passing the valve have the following
values:
• Hardness 6-18 °dH to avoid scaling (chalk / lime stone build up).
• Conductivity 50 – 800 µS/cm to avoid brass dezincification and corrosion.
• Above 25°C media temperature avoid stagnant water inside the valve to avoid dezincification and corrosion
attack.
4 Product specification
(1)
Low pressure steam, 4 bar: Max. 140 °C.
BA AC/DC and BB/BE DC coils: Max. 100 °C.
BO and BP coils: Max. 90 °C.
(2)
BO and BP coils: Max. 90 °C.
Capacity diagram
Example, water: Capacity for EV220B 15B at differential pressure of 3 bar. Approx. 7 m3/h
Example, air:
Capacity for EV220B 15B at inlet pressure (p1) of 5 bar and outlet pressure (p2) of 3.5 bar: Approx. 245 Nm3/h
20
Time to open/close
Table 4: Time to open/close
EV220B EV220B EV220B EV220B EV220B/BW EV220B/BW
Main
15B/BD/SS 20B/BD/SS 25B/BD/SS 32B/BD/SS 40B/BD/SS 50B/BD/SS
Time to open [ms](1) 40 40 300 1000 1500 5000
Time to open [ms] (1) 350 1000 1000 2500 4000 10000
(1)
The times are indicative and apply to water. The exact times wil depend on the pressure conditions.
Closing timescan be changes by replacement of the equalizing orifice.
Materials
Table 5: Materials
Components Materials Specifications
Stainless steel W.no. 1.4581 / AISI 318
Valve body/cover Brass W.no. 2.0402
DZR brass CuZn36Pb2As / CZ132
Armature Stainless steel W.no. 1.4105 / AISI 430 FR
Armature tube Stainless steel W.no. 1.4306 / AISI 304L
Armature stop Stainless steel W.no. 1.4105 / AISI 430FR
Springs Stainless steel W.no. 1.4310 / AISI 301
Orifices Stainless steel W.no. 1.4404 / AISI316L
O-rings EPDM, NBR or FKM
Valve plate EPDM, NBR or FKM
Diaphragm EPDM, NBR or FKM
Weight
L B B1 [mm] / coil type H H1
Type without coil
[mm] [mm] BA BB / BE BG / BO BP [mm] [mm] [kg]
EV220B 32 120 82 32 46 68 45 120 27 2
EV220B / BW 40 130 95 32 46 68 45 129 32 3
EV220B / BW 50 162 113 32 46 68 45 135 37 4.8
Figure 7: Dimension
B₁
32U1783.10
Danfoss
H
H₁
L B
4.3 Mounting
Figure 8: Mounting angle
32U1784.10
Danfoss
5 Ordering
5.2 Accessories
Coils
Table 8: Below coils can be used with EV220B 15 – EV220B 50, EV220BW 40-50
Coil Type Power consumption Enclosure Features
11 - 17 W AC
BE, clip on IP67 With terminal box
15 - 16 W DC
11 - 15 W AC
BF, clip on IP67 With 1 m cable
14 - 16 W DC
11 - 16 W AC
BG, clip on IP67 With terminal box
16 - 20 W DC
For explosion-risk
IP67
10 W AC environment zone 1.
BO, screw on only including seal kit
10 W DC With terminal box and 5 m ca-
018Z0090
ble
Cable plug
Figure 9: Cable plug
NOTE:
Valve height is increased by 16 mm.
32U947.11
32U948.10
Danfoss
Danfoss
1 1
2 2
3 3
4 4
5 5
6
1. 4 x Screws 1. 4 x Screws
2. O-ring 2. O-ring
3. Manual override body 3. Manual override body
4. O-ring 4. O-ring
5. O-ring 5. O-ring
6. Equalizing orifice size III (1)
(1)
For FKM and NBR valves, it is recommended to change the equalizing orifice to size III, to obtain a proper function.
NOTE:
Valve height is increased by 16 mm.
Danfoss
80Z880
1
6
7
1. 4 x Screws
2. Armature tube
3. O-ring
4. Armature incl. closing spring
5. Stainless steel valve body
6. O-ring
7. O-ring
1
Danfoss
5
1. Locking buttom
2. Locking nut
3. 4 x screws
4. Assembled isolating unit
5. O-ring
(1)
Media temperature -20 - 50°C
(2)
Media temperature 0 - 50°C
Orifice
Equalizing orifice
A shorter closing time is obtained with a larger orifice (the shorter closing time, the greater risk of water
hammering). A longer closing time is obtained with a smaller orifice.
The valves closing time can be changed by installing an equalizing orifice of a size which deviates from the standard
valve.
Adjustable orifice
The valves closing time can be adjusted by turning the setting screw.
• A shorter closing time is obtained with a larger orifice (the shorter closing time, the greater risk of water
hammering).
• A longer closing time is obtained with a smaller orifice.
80Z857_10
Danfoss
80Z856_10
Danfoss
1
2
(1)
Approved by WRAS.
Approved by Attestation de Conformite Sanitaire (ACS).
EPDM is recommended of water (Steam max. 40 °C / 4 Bar).
Danfoss
80Z845
1 1
2 2
3 3
5 4
5
7
8
1. Locking button 1. Locking button
2. Locking nut 2. Locking nut
3. Armature with valve plate and spring 3. NO actuator unit
4. O-ring for the armature tube 4. O-ring for armature unit
5. 2x O-rings for the equalizing orifice
6. Closing spring
7. Diaphragm
8. 2 x O-rings for the pilot system
(1)
DN 15-32 approved by WRAS.
DN 15-50 (Brass and DZR) approved by attestation de conformite Sanitaire (ACS) and PZH.
DN 15-50 SS approved by PZH.
EPDM is recommended for water. (steam max. 140 °C/4 bar).
(2)
EPDM is recommended for water. (steam max. 140 °C/4 bar)
Danfoss
80Z894
Danfoss
32U1786_11_032U1071_RJA(1A)
80Z895
1 1
Danfoss
1
2 2
2
3 3
4
5
4 4 6
Danfoss offers a wide range of support along with our products, including digital product information, software,
mobile apps, and expert guidance. See the possibilities below.
Danfoss Learning
Danfoss Learning is a free online learning platform. It features courses and materials specifically
designed to help engineers, installers, service technicians, and wholesalers better understand the
products, applications, industry topics, and trends that will help you do your job better.
Spare Parts
Get access to the Danfoss spare parts and service kit catalog right from your smartphone. The app
contains a wide range of components for air conditioning and refrigeration applications, such as
valves, strainers, pressure switches, and sensors.
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other
technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download,
shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any
responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to
products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material
are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.