This document provides specifications and information about Fluke IR Thermometers models 64 MAX, 62 MAX+, and 62 MAX. It details their temperature ranges, accuracy, response times, memory capabilities, and other technical specifications.

Uploaded by

Daniel Arturo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

64max 62max Ds

This document provides specifications and information about Fluke IR Thermometers models 64 MAX, 62 MAX+, and 62 MAX. It details their temperature ranges, accuracy, response times, memory capabilities, and other technical specifications.

Uploaded by

Daniel Arturo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TECHNICAL DATA

64 MAX, 62 MAX+ and 62 MAX


IR Thermometers

Takes the heat, the dust and water and a 3 meter


drop. And now, internal memory and unattended
monitoring.
The Fluke 64 MAX, 62 MAX+ and 62 MAX IR Thermometers have the
TEMPERATURE RANGE precision you need to do your job accurately and will not break the
64 MAX budget. Designed and tested to survive a 3 meter drop, you can count
-30 °C to 600 °C (-22 °F to 1112 °F)
on these lightweight, compact infrared thermometers to work when
62 MAX+ you need them to work–even in the harshest environments and when
-30 °C to 650 °C (-22 °F to 1202 °F)
you’re not able to be there (64 MAX).
62 MAX
-30 °C to 500 °C (-22 °F to 932 °F) • Precise laser technology for more accurate and repeatable
TEMPERATURE ACCURACY measurements
64 MAX • Temperature accuracy of up to ≥ 0 °C: ± 1 °C or ± 1 % of reading
± 1.0 °C or ± 1.0 % of reading, whichever is greater with 20:1 distance to spot ratio (64 MAX)
whichever is greater
± 2.0 °C at -10 °C to 0 °C • Flashlight (64 MAX) and large, easy-to-read backlit LCD display for
± 3.0 °C at -30 °C to -10 °C easy viewing even in dark environment
62 MAX+
± 1.0 °C or ± 1.0 % of reading, • IP54 rated for extra protection against airborne contaminants
whichever is greater
± 2.0 °C at -10 °C to 0 °C
• Get your tool to work when you can’t–set time and desired interval
± 3.0 °C at -30 °C to -10 °C between measurements and Auto Capture will capture spot tem-
62 MAX
peratures unattended (64 MAX)
± 1.5 °C or ± 1.5 % of reading, • 99 data point logging (64 MAX)
whichever is greater
± 2.0 °C at -10 °C to 0 °C • Displays the minimum, maximum or average temperature, or the
± 3.0 °C at -30 °C to -10 °C difference between two measurements
DISTANCE:SPOT
• Hi and Lo alarms for rapid display of measurements outside set
64 MAX
20:1
limits
62 MAX+ • The 62 MAX+ has dual rotating lasers to help you identify area to
12:1 be measured. The measurement area is the spot between the dots
62 MAX (62 MAX and 64 MAX have 1).
10:1
• Small and lightweight, fits easily into your tool box
INTERNAL MEMORY
64 MAX
99 data point logging
AUTO CAPTURE
64 MAX
Specifications
64 MAX 62 MAX+ 62 MAX
Key features
- 30 °C to 600 °C - 30 °C to 650 °C - 30 °C to 500 °C
Temperature range
(-22 °F to 1112 °F) (-22 °F to 1202 °F) (-22 °F to 932 °F)
Accuracy (Calibration ± 1.5 °C or ± 1.5 % of reading, whichever is greater
± 1.0 °C or ± 1.0 % of reading, whichever is greater
geometry with ambi-
± 2.0 °C at -10 °C to 0 °C ± 2.0 °C at -10 °C to 0 °C
ent temperature 23 °C
± 3.0 °C at -30 °C to -10 °C ± 3.0 °C at -30 °C to -10 °C
+/- 2 °C)
20:1 12:1 10:1
Optical resolution
(calculated at 90 % energy) (calculated at 90 % energy) (calculated at 90 % energy)
Response time (95 %) < 500 ms (95 % of reading) < 300 ms (95 % of reading) < 500 ms (95 % of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Display resolution 0.1 °C (0.2 °F)
Repeatability (% of ± 0.8 % of reading or
± 0.5 % of reading or ± 0.5 °C (whichever is greater)
reading) ± 1 °C (whichever is greater)
Set time and interval
Auto Capture -
to capture up to 99 measurements
Internal memory 99 data point logging capability -
Flashlight Yes -
Power 1 AA alkaline battery
Battery life 30 hours with laser and backlight on 8 hours with laser and backlight on 10 hours with laser and backlight on
Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating temperature 0 °C to 50 °C (32 °F to 122°F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) (without battery)
Non- condensing @ ≤ 10 °C (50 °F)
≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)
Operating humidity
≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)
≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
Drop test 3 meters
Implement standard Q/ASF01
Standards and agency approval
Compliance IEC 61010-1: Pollution Degree 2

Laser safety IEC 60825-1 Class 2, 650 nm, < 1 mW

Ingress protection rating IP 54 per IEC 60529


Warranty 3 years

Ordering information
Fluke-64 MAX IR Thermometer
Fluke-62 MAX+ IR Thermometer
Fluke-62 MAX IR Thermometer

Included with product


IR Thermometer
Printed instruction sheet
Carabiner (62 MAX+ only)
Product manuals available for download from fluke.com

Kits
Fluke T5-600/62 MAX+/1AC II Fluke. Keeping your world For more information call:
In the U.S.A. (800) 443-5853 or
IR Thermometer, Electrical Tester up and running.® Fax (425) 446-5116
and Voltage Detector Kit In Europe/M-East/Africa +31 (0)40 267 5100 or
Fluke 62 MAX+/323/1AC Fluke Corporation Fax +31 (0)40 267 5222
PO Box 9090, Everett, WA 98206 U.S.A. In Canada (800)-36-FLUKE or
IR Thermometer, Clamp Meter and Fax (905) 890-6866
Voltage Detector Kit Fluke Europe B.V. From other countries +1 (425) 446-5500 or
PO Box 1186, 5602 BD Fax +1 (425) 446-5116
Optional accessories Eindhoven, The Netherlands Web access: http://www.fluke.com
FLK-TI-TRIPOD Tripod Mounting Accessory for 64 MAX Modification of this document is not ©2017 Fluke Corporation.
permitted without written permission Specifications subject to change without notice.
from Fluke Corporation. 2/2017 6008893b-en