Parts
Parts
1 04453846 CAREPROFILE - C
Radiation free placement of collimator blades in the LIH.
Qty Part No. Item Description
1 04484106 Careposition C
Radiation-free object positioning through graphic display of the X-ray center beam and the
image edges in the LIH (Last Image Hold) for dose reduction.
1 14402070 Fluoroloop - C
Storage and review of dynamic fluoroscopic sequences (Fluoro Loop) with all available frame
rates. The fluoroscopic sequence can be stored subsequently, after fluoroscopy has been
performed. The maximum storable fluoroscopy time depends on the selected pulse rate.
1 14428639 VA Kit
Second documentation set for deliveries to the Veterans' Affairs Administration Hospitals in
the U.S.
I
Qty Part No. Item Description
OPTIONS:
Patient positioning
Patient positioning table easily accessible from all sides, tiltable from +90° to max. 20° Trendelenburg position.
- Table height adjustable from 65 to 112 cm (min. fluoro height 82 cm)
- Patient positioning tabletop 210 cm x 80 cm with examination range over the entire radiolucent part (193 cm x
53 cm). Motorized longitudinal travel ± 80 cm and transverse travel ± 17.5 cm.
- Foot rest insertable at head or foot end, up to a load of 230 kg.
- Comprehensive collision protection within the travel range of the image receptor.
Patient weight:
- Up to 182 kg (400 lbs) No limitation for tabletop movement longitudinal ±80 cm from center position, table tilt
is permitted.
- From 182.1 kg to 230 kg (400.1 lbs to 507 lbs): Longitudinal travel of tabletop limited to ±40 cm from center
position, table tilt is permitted.
- From 230.1 kg to 275 kg (507.1 lbs to 606 lbs): Tabletop movement and table tilt are not permitted.
Transparent grids improve the image quality by reducing scattered radiation on the film.
Flat detector:
The digital high-resolution dynamic flat detector with integrated removable grid is especially designed to fulfill the
requirements of general and interventional applications.
- Semi-conductor material: Amorphous silicon (a-Si) with CsI-scintillator
- Size 43 cm x 43 cm
- Pixel size: 148 µm (6.76 pixel per mm)
- Matrix size: 2,880 x 2,880 (8.3 million pixels)
- Detail resolution: 3.4 LP/mm
- Acquisition depth: 16 bits
148 m pixel arrays provide highest spatial resolution and excellent contrast. Fluoroscopy as well as image
acquisition are always done in 14-bit gray scale resolution, allowing excellent detail visibility. Acquisition frame
rates of up to 8 f/s are possible.
Multileaf collimator
Undertable multileaf collimator with rectangular collimation for automatic format collimation. Motor-driven Cu
prefilters.
CAREmax
Electronic unit with KermaX-Plus, a measurement chamber integrated into the collimator housing for acquisition
and fluoro systems to record the dose area product and/or standardized patient entry dose.
Detector tray
Detector tray with automatic format selection ACSS (automatic cassette size sensing) for acquisitions with the
fully-synchronized Ysio ceiling support as 2nd plane. It is positioned underneath the patient positioning tabletop
and has a longitudinal travel range of 100 cm.
Automatic servo tracking of the tray (at the table level and for source-image distance).
Automatic parking of the tray when selecting a fluoro organ program.
In 2 further axes ( - and -axes) the tube assembly collimator unit can be manually adjusted for oblique
acquisitions of the recumbent patient, or for horizontal, oblique, or lateral acquisitions on the portable detector, or
for free bedside acquisitions.
- Rotation around the vertical axis of the ceiling-mounted support from +154° to -182°. Lock-in positions every
90°.
- Rotation around the horizontal axis of the tube assembly support arm ±140°. Lock-in positions at 0° and ±90°.
Multileaf collimator:
With full field and laser line light localizer. Rectangular collimation, manual and motorized, via organ programs.
- Multileaf collimator rotatable by ±45° around the center beam axis, e.g. for correct positioning of objects.
- A tape measure is integrated to check the focus-to-object distance.
- To improve radiation quality through dose reduction of the soft radiation parts, Cu filters (0.1Cu; 0.2 CU and
0.3 Cu) are inserted into the primary beam projection, depending on the organ program selected. They can
also be selected manually.
Option:
A measuring chamber for the dose area product can be integrated into the multileaf collimator.
- Ambient light sensor for optimum adaptation of the image display to the room brightness.
Imaging system
High-resolution digital imaging system with innovative image display, DICOM network connection and syngo-like
user interface. It was optimized for general fluoro and multi-functional workplaces.
With the FLUOROSPOT Compact both single acquisitions and series from 0.5 to 8 images per second in 1440²
matrix can be made and reviewed dynamically.
The digital acquisition process produces continuously high-quality images for all fluoroscopy-guided contrast
medium examinations, skeletal acquisitions and interventional procedures.
Operating modes:
- Digital radiography (DR) with up to 2,880²/12-bit matrix.
- CAREvision: Pulsed fluoroscopy with selectable pulse frequencies 3 f/s, 7.5 f/s, 10 f/s, or 15 f/s in 1024²/12-bit
matrix.
- High-speed fluoro at 30 f/s in Zoom 2 (22 cm x 22 cm)
Pulsed fluoroscopy is especially suitable for time-intensive examinations to reduce the radiation dose for
physician, staff, and patient.
- Display and storage of the last fluoroscopic image after switching off radiation (Last Image Hold).
- Single image and serial mode up to 1,440²/12-bit or 1,024²/12-bit matrix (depending on zoom).
- Serial mode (max. 8 f/s) with variable frame rate in three steps (max. 1,440²/12-bit matrix).
- DDO (Dynamic Density Optimization) for on-line harmonization of native series and single images.
- Live auto-windowing during fluoroscopy
- Live auto-shutter during fluoroscopy
Image processing:
- Real-time edge enhancement, positive/negative image display, windowing, contrast/brightness, electronic
display (shutter), image shift (roaming), vertical and horizontal image inversion, magnifying glass and zoom
functions.
- DiamondView Plus: multi-scaling procedure for image post-processing with high detail contrast and reduced
noise. Filter size and strength are weighted differently and are used for adaptation to the overall image
content. DiamondView Plus enhances the signal exploitation of the dynamic range and improves the organ-
specific detail contrast (soft tissue and bone). Can be preset in the organ program, and can subsequently be
selected or deselected.
- Storing of single images as reference images also during fluoroscopy.
- Quantification: angle/length measurement, automatic and/or manual calibration.
- Text functions: User-defined image annotation, free annotation or using text components, comment line for
the image, R/L display, image report and image quality graphics.
- Image gallery for harmonization (visualization support for image post-processing)
Image display:
Image review and display in 100 Hz progressive display (1,024² matrix) through high-resolution, flicker-free flat-
Part No. / Product Description
(Continued) screen displays.
14428644 - Screen layout with 4, 9, 16, 25, or 36 images of an examination.
Lum. Agile w/ Ysio - Display of R/L marks.
Opt. f. wi-D
Image storage capacity:
50,000 images for permanent storage in 1k/12-bit matrix and 2,000 images for permanent storage in 2840 x 2880
matrix.
Connectivity
- DICOM Send: Digital, unidirectional image transfer of single images or complete folders to a network in
DICOM format.
- DICOM Print: Provision of DICOM Print service for connection to a laser camera or a network printer
(postscript-capable).
- DICOM Storage Commitment (StC): The network/archive sends a receipt acknowledgment for images/folders
to the image system in DICOM format.
The description in the "DICOM Conformance Statement" downloadable from the Internet is exclusively binding for
the functionality of the DICOM interface(s).
Functionalities across system borders with/between partner systems require explicit validation, since the
interpretation of the interface by the partner/target system is not part of the product's responsibility.
A modification of the interface that might be required is not included in the offer; e.g. for the rare case, that
available configurations are not sufficient.
With regard to expenses for interface configurations that might be required, the agreements on
maintenance/service of the product apply.
Prerequisite for the early warning system is a permanent connection to the system via LAN and router. It is the
project manager's task to make this available on-site.
You will find detailed information on our e-learning program and further details on general Customer Care. Life
services on the internet.
* Not all services of the Customer Care. Life offerings are necessarily available for all systems.
14417239 Mobile, wireless flat detector (wi-D) for image acquisition, 3543pR, CsI scintillator, amorphous silicon (a-Si).
wi-D (wireless - Detector acquisition matrix approx. 3,000 x 2.364 (7 million pixels).
detector) - Pixel size 144 µm
- Acquisition depth (gray scales) 16 bit.
- Acquisition formats up to 34.0 cm x 43.2 cm (13.4" x 17").
- Data transmission via W-LAN or backup cable.
- Wireless use for approx. 2 hours.
- Detector weight 4.8 kg
- Max. load 135 kg (patient lying down) and 100 kg (patient standing).
Loading and receiving unit for the wireless detector connected to PACS via the imaging system.
Functionalities across system borders with/between partner systems require explicit validation, since the
interpretation of the interface by the partner/target system is not part of the product's responsibility.
A modification of the interface that might be required is not included in the offer; e.g. for the rare case, that
available configurations are not sufficient.
With regard to expenses for interface configurations that might be required, the agreements on
maintenance/service of the product apply.
Functionalities across system borders with/between partner systems require explicit validation, since the
interpretation of the interface by the partner/target system is not part of the product's responsibility.
A modification of the interface that might be required is not included in the offer; e.g. for the rare case, that
available configurations are not sufficient.
With regard to expenses for interface configurations that might be required, the agreements on
maintenance/service of the product apply.
Part No. / Product Description
04453846 Radiation-free positioning of primary collimators in the LIH on the monitor. Especially suitable for dose-saving
CAREPROFILE - C examinations.
04484106 With CAREposition it is possible to position an object without radiation under visual control.
Careposition C In case of table movement, the current radiation field position and the center beam position are superimposed on
the LIH as orientation points.
04484114 SW license for systems with FLUOROSPOT Compact to support enhanced user management, including:
Security Package - user authentication to prohibit unauthorized access.
- privileges to define user/role based functionality.
- permissions to control data access.
- audit trails to log system and data access.
14428636 Ceiling-mounted, swiveling rotatable and height-adjustable display suspension system with longitudinal travel and
DCS 1FT with 1 one (1) 19 high-contrast b/w display for live image display in the examination room.
Display b/w
Monochrome TFT technology with high luminance and extended viewing angle.
- Screen size 19" (48 cm).
- Resolution: 1280 x 1024 (pixels).
- Maximum brightness (typ.): 1000 cd/m .
2
The ceiling-mounted tube assembly support can be adjusted in 3 axes for longitudinal, transverse, and height
adjustment (x, y, and z-axes).
- Horizontal travel range in longitudinal direction 346 cm.
- Horizontal travel range in transverse direction 220 cm.
- Vertical lift 180 cm.
In 2 further axes ( - and -axes) the tube assembly collimator unit can be manually adjusted for oblique
acquisitions of the recumbent patient, or for horizontal, oblique, or lateral acquisitions on the portable
detector/cassette, or for free bedside acquisitions.
- Rotation around the vertical axis of the ceiling-mounted support from +154° to -182°. Lock-in positions every
90°.
- Rotation around the horizontal axis of the tube assembly support arm ±140°. Lock-in positions at 0° and ±90°.
X-ray tube assembly OPTITOP 150/40/80 HC-100:
Single-track dual-focus rotating anode tube with compound anode (rhenium-tungsten, molybdenum, graphite), with
high heat storage capacity and high load capacity for small focal spots. Integrated overpressure safety device in
the tube protective housing.
- 150 kV nominal voltage acc. to IEC 613.
- Nominal power (focal spot nominal values acc. to IEC 336):
40 kW: small focus 0.6
80 kW: large focus 1.0
- Anode speed 8,500 r/min, anode angle 12°.
Part No. / Product Description
(Continued) - Heat storage capacity of the anode 580 kJ (783 kHU) acc. to IEC 613.
14428628 - Total filtration (IEC 601-1-3) 2.5 mm Al equiv.
Fully synch. ceiling-
mtd. stand, 3m Multileaf collimator:
With full field and laser line light localizer. Rectangular collimation, manual and motorized, via organ programs.
- Multileaf collimator rotatable by ±45° around the center beam axis, e.g. for correct positioning of objects.
- A tape measure is integrated to check the focus-to-object distance.
- To improve radiation quality through dose reduction of the soft radiation parts, Cu filters (0.1Cu; 0.2 CU and
0.3 Cu) are inserted into the primary beam projection, depending on the organ program selected. They can
also be selected manually.
Option:
A measuring chamber for the dose area product can be integrated into the multileaf collimator.
14407006 Electronics unit with KermaX-Plus, a measurement chamber integrated into the collimator housing for acquisition
Caremax plus HS and fluoro systems with POLYDOROS generator for acquisition of dose-area product and/or standardized patient
Integrated entry dose.
Display of the measured dose-area product and the calculated patient entry dose (CAREwatch) on the flat-screen
display, with CAREmax.
It is especially suited for acquisitions of skeletal radiography of the standing and seated patient:
- Orthopedic diagnostics.
- Thorax and general diagnostics.
- Trauma and ER diagnostics.
With this Bucky wall stand more profound diagnostic requirements for acquisitions of thorax (lungs), abdomen,
pelvis, spine, skull and extremities are met.
The basic configuration consists of a radiography system with a vertically positioned detector Bucky for horizontal,
oblique, or lateral patient acquisitions.
The additional tilting range* of the detector Bucky extends the diagnostically relevant acquisition projections.
- Vertical height adjustment of the counter-balanced, easily movable detector Bucky from detector center
approx. 26 cm to 173 cm above floor:
- Tilting range between 0° and +90°, and up to -20° continuously around the horizontal axis; lock-in position at
0°.
- In combination with a ceiling-mounted support, tracking between it and Bucky wall stand.
Detector Bucky
The detector Bucky with single-handed operation includes a IONTOMAT three-field chamber for automatic
exposure control (incl. three-field templates) and a device for symmetric positioning of the flat detector.
- Front plate detector distance 37 mm.
- Radiation absorption of the front plate 0.55 mm Al.
- A stationary, exchangeable transparent grid for scattered radiation reduction; Pb 15/80. Optionally for SID 115
cm and/or 150 cm and/or 180 cm (see tender further down).
Removable grid:
The grid can easily be removed, saving the user time in examinations not requiring a grid. For example in
pediatrics, where dose reduction is especially important.
Accessories
Scope of delivery:
- Lateral patient handles for optimum patient positioning, e.g. during PA thorax exposures.
- Patient overhead handle, swiveling around the horizontal axis, for optimal patient positioning for lateral
Part No. / Product Description
(Continued) acquisitions.
14411248
Bucky Wall Unit for *) Only in conjunction with ceiling-mounted support; no tilting when combined with basic X-ray tube.
wi-D right
14411087 Wired control unit at Bucky wall unit with the following functions:
Manual Control - On/off tube tracking
Bucky Wall Unit - On/off light localizer
- Tube parking*
- Tuber centering*
- Autopositioning of tube*
14409345 This mobile and height-adjustable holder is designed for use with a mobile, digital flat detector (with or without
Detector Holder, grid). Alternatively, it can be used for fixating cassettes with film-transparency systems or storage phosphor
Mobile screens.
This mobile holder can be positioned freely in the room or at the patient or positioning table; acquisitions with
vertical, horizontal, and oblique beam projections can be made.
- Clamping size of the holder for detectors 53.5 cm wide and up to 3.3 cm thick.
- Clamping size for cassette formats between 24 cm and 55 cm wide.
- Height adjustment from the lower edge of the detector holder up to 2 cm to 120 cm above the floor.
- Height adjustment counterbalanced at a total weight of approx. 6.7 kg.
04491234 Compression is achieved through an easy-to-clean, radiolucent plastic belt by means of a tensioning device with
Compression band locking.
Advantages of compression:
- Fast and secure fixation of patient to the tabletop.
- Reduction of patient thickness, i.e. improvement of image quality through reduction of scattered radiation.
08861002 The radiolucent table pad matches the size of the tabletop and has a heavy-duty soft plastic cover that is easy to
Patient positioning clean. The soft cushion allows comfortable patient positioning and repositioning.
mattress To prevent the pad from sliding during head-up positions, the straps of patient table pad can be attached to the
handrail at the head end.
08860947 Leg supports are required for gynecological and urological examinations. They can be adjusted in height and for
Knee Crutches leg positioning, the leg supports are anatomically designed.
(Stirrups), pair The leg support is attached with a clamping device and clamping bolts.
AXD_INITIAL_24 Up to 24 hours of on-site clinical education training, scheduled consecutively (Monday Friday) during standard
Initial onsite training business hours for a maximum of (4) imaging professionals. Training will cover agenda items on the ASRT
24 hrs approved checklist. Uptime Clinical Education phone support is provided during the warranty period for specified
posted hours. This educational offering must be completed (12) months from install end date. If training is
not completed within the applicable time period, Siemens obligation to provide the training will expire
without refund.
AXD_ADD_12 Up to (12) hours of on-site clinical education training, scheduled consecutively (Monday Friday) during standard
Additional onsite business hours for a maximum of (4) imaging professionals. Training will cover agenda items on the ASRT
training 12 hours approved checklist if applicable. This educational offering must be completed (12) months from install end
date. If training is not completed within the applicable time period, Siemens obligation to provide the
training will expire without refund.
CID4948 The unique design of the DR Panel Protector provides an easy way to take weight-bearing x-rays of feet (AP view).
Portable DR Panel The unit is simply placed over the DR panel which is first positioned on the floor. Patients step onto the DR Panel
Protector Protector with as much weight as needed to get the desired image. The face plate is made of polycarbonate
designed to support patients weighing up to 500 pounds. The face plate is x-ray lucent, allowing the x-rays to
pass through the DR Panel Protector with no significant absorption or scattering. The non-slip rubber floor grips
Part No. / Product Description
(Continued) keep the DR Panel Protector from slipping on a hard floor. The Panel Protector frame is notched to accommodate
CID4948 the cable connection from the digital DR panel to the host system. One year warranty through Clear Image
Portable DR Panel Devices.
Protector
PKP07300U00 EZ PIC is a video acquisition workstation that enables digital recording to a hard drive on the workstation for
EZ PIC Universal review, editing and exporting to portable media and storage systems, including PACS. The EZ PIC provides audio
Package recording capabilities and audio playback functionality. The EZ PIC is on a PC platform and includes a keyboard,
mouse, and an LCD display with built in speakers. Perkins Electronics provides the EZ PIC Package system in a
complete installation and product package that is designed to be integrated to the R/F system providing recording
control to the R/F system footswitch providing a seamless integration to the R/F modality.
Package includes:
1 PAK-07300-U00 EZ PIC System
EZ PIC Processor
20" LCD
Keyboard & Mouse
EZ PIC Scan Converter
Installation Kit
Includes applicable video power cables
Includes 1 year service agreement from Perkins Electronics.
AXD_INITIAL_12 Up to (12) hours of on-site clinical education training, scheduled consecutively (Monday Friday) during standard
Initial onsite training business hours for a maximum of (4) imaging professionals. Training will cover agenda items on the ASRT
12 hrs approved checklist. Uptime Clinical Education phone support is provided during the warranty period for specified
posted hours. This educational offering must be completed (12) months from install end date. If training is
(Optional)
not completed within the applicable time period, Siemens obligation to provide the training will expire
without refund.
Acquisitions at the patient table should use a source-image distance (SID) of 150 cm. If 150 cm is not possible,
reduce the source-image distance (SID) to 115 cm.
The Ortho package (ortho support and grid Pb 15/80, 300 cm grid focusing) has to be ordered separately.
The use of an 80kW generator is recommended for acquisitions of the lateral spine.
Spine Composing
Spine Composing takes individually acquired digital radiographic images of the spine and composes them into an
overall image.
Ortho-Leg Composing
Ortho-Leg Composing takes individually acquired digital radiographic images of the legs and composes them into
an overall image.
Part No. / Product Description
(Continued)
14428649 The main functions are:
Ortho applications - automatic composing of digital radiographies into an overall image.
package - standard image post-processing functions are available.
(Optional)