CMM366A-4G

CLOUD MONITORING COMMUNICATION MODULE

USER MANUAL
Chinese trademark

English trademark
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: +86-371-67988888/67981888/67992951
+86-371-67981000 (overseas)
Fax: +86-371-67992952
Web: www.smartgen.com.cn/
www.smartgen.cn/
Email: [email protected]

All rights reserved. No part of this publication may be reproduced in any material form (including
photocopying or storing in any medium by electronic means or other) without the written permission of
the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication
should be addressed to SmartGen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective
companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.

Table 1 – Software Version

Date Version Note


2017-12-25 1.0 Original release.
2022-07-14 1.1 Update company logo and manual format.

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 2 of 16


CONTENT

1 OVERVIEW ................................................................................................................................................. 4
2 PERFORMANCE AND CHARACTERISTICS.............................................................................................. 4
3 SPECIFICATION ........................................................................................................................................ 5
4 PANEL AND TERMINAL DESCRIPTION ................................................................................................... 6
4.1 PANEL INDICATOR AND BUTTONS ...................................................................................................... 6
4.2 GPRS ......................................................................................................................................................... 7
4.3 GPS............................................................................................................................................................ 7
4.4 SIM INSTALLATION ................................................................................................................................ 7
4.5 RS485........................................................................................................................................................ 8
4.6 RS232........................................................................................................................................................ 8
4.7 LINK........................................................................................................................................................... 9
4.8 USB HOST................................................................................................................................................. 9
4.9 USB DEVICE.............................................................................................................................................. 9
4.10 TERMINAL .............................................................................................................................................. 10
5 PROGRAMMABLE PARAMETERS .......................................................................................................... 11
5.1 CONTENTS AND SCOPES OF PARAMETERS..................................................................................... 11
5.2 PC CONFIGURATION INTERFACE ....................................................................................................... 13
6 SYSTEM DIAGRAM ................................................................................................................................. 14
7 CASE DIMENSION AND INSTALLATION ............................................................................................... 15
8 FAULT FINDING ...................................................................................................................................... 16
9 PACKING LIST ......................................................................................................................................... 16

CMM366A-4G Cloud Monitoring Communication Module Page 3 of 16


1 OVERVIEW

CMM366A-4G Cloud Monitoring Communication Module is 4G GPRS wireless network


communication protocol switch module which can achieve genset (with SCI) connect to Internet. After
logging into cloud server, module will receive corresponding genset controller communication protocol
from cloud server. And the module gains genset data via RS485 port, USB port, LINK port or RS232 port.
Then the module transmits the data to corresponding cloud server via 4G wireless network for
achieving user’s real-time monitoring to running status and searching of running records via APP (IOS
or Android) and pc terminal devices.
CMM366A-4G module not only can achieve genset monitoring but also can insert some digital
alarm input/output signal to achieve monitoring of generator room entrance guard, guard against theft
and fire facilities.
CMM366A-4G module, which has GPS locate function, can upload gained longitude, latitude and
altitude to corresponding cloud server.

2 PERFORMANCE AND CHARACTERISTICS

 Connect to cloud server via 4G wireless network, one to one monitoring;


 Multiple ports for communication with genset control module: RS485, RS232, LINK and USB (Host);
can monitor great majority genset control modules of international first-class brands;
 Widely power supply: DC (8~35)V, can direct use genset built-in battery;
 With ARM-based 32-bit SCM, high integration of hardware and strong programming ability;
 Include with GPS locate function to achieve gain location information and locate genset;
 Take JSON network data communication protocol, upload real-time data variation and take
compression algorithm to vastly reduce network flow at the same time;
 When alarm occurs it can upload data to server immediately;
 2 auxiliary digital input ports which can receive external alarm signal;
 1 auxiliary relay output ports which can output various of alarm signal;
 Power and multiple communication status indicators on front panel that working status is clear at
a glance;
 Lamp test function;
 Parameter adjust function: users can adjust parameters via USB port;
 Take standard π-type 35mm guide-rail installation or screw-fixed installation that the module can
be installed in the genset control box;
 Modular design, self extinguishing ABS plastic shell, light weight, compact structure with easy
installation.

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 4 of 16


3 SPECIFICATION

Table 2 – Technical Data

Items Contents
Operating Voltage DC 8.0V~35.0V, continuous power supply.
Standby: ≤2W
Power Consumption
Working: ≤5W
Digital Input Digital Input, connect (B-) is active.
Relay Output 1A DC30V Volts free output
USB Host A-type USB female port
RS485 Isolated type
RS232 General type
LINK SmartGen exclusive port
USB Device B-type USB female port
GPRS Port Standard SMA port (female), SMA port (male) for antenna
GPS Port Standard SMA port (female), SMA port (male) for antenna, active antenna
LTE-TDD/LTE-FDD/HSPA+/TD-SCDMA/EVDO
Wireless Network
GSM/GPRS/EDGE
Case Dimensions 72.5mmx105mmx34mm
Working Temperature (-25~+70)°C
Working Humidity (20~93)%RH
Storage Temperature (-25~+70)°C
Weight 0.15kg

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 5 of 16


4 PANEL AND TERMINAL DESCRIPTION

4.1 PANEL INDICATOR AND BUTTONS

Fig.1 – CMM366A-4G Front Panel Diagram

Table 3 – Indicators Description

Icon Note
Green LED Light: Power supply normal indicator;
POWER/ALARM
Red LED Light: Common alarm indicator.
Normally Extinguish: RS485 disabled;
RS485(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: USB(Host) disabled;
USB(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: GPS disabled;
GPS(Red) Normally Light: GPS not gained satellite signal;
Blink: GPS gained satellite signal.
Normally Extinguish: Disabled;
LINK(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: RS232 disabled;
RS232(Red) Normally Light: Communication fail;
Blink: Communication normal.
Extinguish: CMM366A-4G login with server unsuccessfully;
GPRS/4G(Red) Light: Login with server successfully;
Blink: Real-time communication normal.

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 6 of 16


Internal Lamp test/Reset Key:
Press it for 1s, all the LEDs are illuminated; press it for 10s, reset the module to default and all the
LEDs blink for 3 times.
NOTE: After reset the module, parameters need to be re-configured via PC software. Please operate cautiously.

4.2 GPRS

Connect GPRS antenna to GPRS/4G port.


Antenna: 50Ω/SMA female.

4.3 GPS

GPS enabled, connect GPS antenna to CMM366A-4G.


NOTE: GPS antenna needs to be placed to open outdoors, otherwise location information may not accurate or cannot
be gained.
Antenna: 50Ω/SMA female, active antenna.

Fig.2 – CMM366A-4G Antenna Connection

NOTE: GPRS antenna and GPS antenna cannot be connected reversely.

4.4 SIM INSTALLATION

Insert 4G, 3G or 2G SIM card. CMM366A-4G will connect to servers via wireless mobile network.
NOTE: 4G GPRS wireless network is supported. Use standard SIM card (25mmX15mm); GPS indicator and GPRS
indicator blink in the same time, which means SIM card hasn’t been inserted or bad contacts.
After removing the head cover, the installation steps are as below:

Fig.3 – SIM Card Installation Steps

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 7 of 16


4.5 RS485

Receive genset data information by connecting module RS485 port with Genset Controller RS485
port.
If communication is abnormal, 120Ω terminal resistance is recommonded. One end of shield wire
hangs in the air and the other one connects with SCR.

Fig.4 – RS485 Connection

4.6 RS232

Receive genset data information by connecting module RS232 port with Genset Controller RS232
port.

Fig.5 – RS232 Connection

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 8 of 16


4.7 LINK

Receive genset data information by connecting module LINK port with Genset Controller LINK port.

Fig.6 – LINK Connection

4.8 USB HOST

Receive genset data information by connecting module A-type USB port (female port) with Genset
Controller USB port via USB cable.

Fig.7 – USB HOST Connection

4.9 USB DEVICE

All the parameters can be configured and view CMM366A-4G ID&Login password by connecting
USB port with USB disk of PC software.

Fig.8 – USB Connect PC Device

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 9 of 16


4.10 TERMINAL

Table 4 – Terminals Description

No. Function Cable Size Note


2
1 B- 1.0mm Connected with negative of starter battery.
Connected with positive of starter battery. 3A
2 B+ 1.0mm2
fuse is recommended.
3 Digital Input 1 1.0mm2 Active when connect to B-.
2
4 Digital Input 2 1.0mm Active when connect to B-.
Normally
5 1.0mm2
Open
Relay
6 Common 1.0mm2 Volt free output with 1A DC30V.
Output
Normally
7 1.0mm2
Close
8 RS485 B(-) 0.5mm2
Impedance-120Ω shielding wire is recommended,
9 RS485 A(+) 0.5mm2
its single-end earthed.
10 RS485 (SCR) 0.5mm2
11 RS232 RX 0.5mm2
12 RS232 TX 0.5mm2 RS232 port.
13 RS232 GND 0.5mm2

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 10 of 16


5 PROGRAMMABLE PARAMETERS

5.1 CONTENTS AND SCOPES OF PARAMETERS

Table 5 – Parameter Content & Scope

No. Items Parameters Defaults Description


Gateway
20 Chinese characters, letters or
1 Site Name (0-65535)
numbers
2 URL (0-65535) www.monitoryun.com 40 characters
3 Server Port (0-65535) 91
4 Security Code (0-65535) 123456 16 characters
GPS
1 GPS Enabled (0-1) 1 0: Manual Input 1: GPS Location
2 Longitude ((-180)-180)° 0.000000
3 Latitude ((-90)-90)° 0.000000 GPS location, altitude information
4 Altitude ((-9999.9)-9999.9)m 100.0
GSM
1 GSM Enabled (0-1) 1 0: Disabled; 1: Enabled
2 GPRS Password Reserved
3 Message Center Reserved
4 PIN Enabled (0-1) 0 0: Disabled; 1: Enabled
5 APN (0-65535) 40 characters
Digital Input
Digital Input 1
1 Setting (0-9) 0 Default: Not used
0: Active when close
1: Active when open
2 Type (0-1) 0
See: Table 6 – Digital Input Ports
Content
3 Delay (0-20.0) 0.0 Action delay
Digital Input 2
1 Setting (0-9) 1 Default: Lamp test
0: Active when close
1: Active when open
2 Type (0-1) 0
See: Table 6 – Digital Input Ports
Content
3 Delay (0-20.0) 0.0 Action delay
Digital Output
Default: Not used
1 Setting (0-14) 0 See: Table 7 – Relay Output Ports
Content
NOTE: Configuration of monitoring genset controller model, communication port, communication baud rate, and
communication ID need to be set on the platform, and cloud monitoring module needs to restart up after setting.

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 11 of 16


Table 6 – Digital Input Ports Content

No. Item Description


0 Not Used Not used.
1 Lamp Test All the indicators are illuminated when input is active.
2 Remote Control Inhibited Cloud start/stop control is prohibited when input is active.
3 Access Alarm Input Access alarm is uploaded to server when input is active.
4 Fire Alarm Input Fire alarm is uploaded to server when input is active.
5 Alarm Input External alarm is uploaded to server when input is active.
6 Reserved
7 Reserved
8 Reserved
9 Factory Test Mode It is only used for factory test when active.

Table 7 – Relay Output Ports Content

No. Item Description


0 Not used Output port won’t output when this item is selected.
1 Digital Input 1 Active Output when auxiliary input 1 is active.
2 Digital Input 2 Active Output when auxiliary input 2 is active.
3 RS485 Comm. Fail Output when RS485 communication fails.
4 Network Comm. Fail Output when Network communication fails.
5 LINK Comm. Fail Output when LINK communication fails.
6 RS232 Comm. Fail Output when RS232 communication fails.
7 Common Alarm Output when there is an alarm.
Send remote control commands via cloud platform with fixed
8 Remote Control Output
output delay 20s.
9 Reserved
10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 Reserved

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 12 of 16


5.2 PC CONFIGURATION INTERFACE

Connecting the USB port of CMM366A-4G communication module with PC USB port to configure
the parameters.

Fig.9 – Gateway Configuration

Fig.10 – Module Monitoring Interface

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 13 of 16


6 SYSTEM DIAGRAM

One CMM366A-4G module connects with one genset monitor module. It can be connected via
RS485 port, LINK port, RS232 port or USB port.

Fig.11 – CMM366A-4G System Diagram

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 14 of 16


7 CASE DIMENSION AND INSTALLATION

2 ways for installation: 35mm guide rail in box or screw (M4) installation as below:

Fig.12 – CMM366A-4G Case Dimension

Fig.13 – CMM366A-4G Guide Rail Installation

Fig.14 – CMM366A-4G Screw Installation

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 15 of 16


8 FAULT FINDING

Table 8 – Fault Finding

Symptoms Possible Solutions


Controller No Response for Check power voltage;
Power Check controller connection wirings.
Check SIM card is inserted or not;
GPRS/4G Indicator Not Light
Check GPRS antenna is connected or not.
Check GPS parameters are enabled or not;
GPS Not Gain Location
Check GPS antenna is connected or not and placed outdoor or not.
Check connections;
Check RS485 port is enabled or not;
RS485 Comm. Abnormal
Check settings of genset ID and baud rate are correct or not.
Check RS485’s connections of A and B is reverse connect or not.
Check connections;
RS232 Comm. Abnormal Check RS232 port is enabled or not;
Check settings of genset ID and baud rate are correct or not.
Check connections;
LINK Comm. Abnormal Check LINK port is enabled or not;
Check settings of genset ID and baud rate are correct or not.

9 PACKING LIST

Table 9 – Packing List

No. Name Quantity Remark


1 CMM366A-4G 1
2 Osculum type GSM antenna 1
3 External GPS antenna 1
4 Certificate 1
5 User manual 1

_________________________________

CMM366A-4G Cloud Monitoring Communication Module User Manual Page 16 of 16