Document No: AccuVueMED_UM_COM_EN_01

Revision No: Rev.03.

Released By 2019-03-19
About This Manual
The AccuVueMED User Manual provides instructions for the configuration and use of
AccuVueMED radiological software, developed by RadmediX.

The manual contains the following contents.

✓ Operation Environment, Installation and Method for AccuVueMED


✓ Functions and Instructions for AccuVueMED

Please contact us if there are any problems during the use of the product.
WebSite http://www.radmedix.com
Customer Email [email protected]
Support Team Tel +1-844-723-6334 ex. 2
Fax +1-513-278-0150

To Enhance The Quality Of Human Life!

AccuVueMED_UM_COM_EN_01
About This Manual

Copyright Manual

Information contained in this manual is confidential and is the property of RADMEDIX Inc.,
and is provided exclusively for authorized licensees of RADMEDIX Inc.

The information contained in this manual may not be altered or distributed without prior
written consent of RADMEDIX Inc., and may not be disclosed to unauthorized personnel.

Information contained herein is subject to change without prior notice.

Copyright © 2013 RADMEDIX Corporation. All rights reserved.

AccuVueMED_UM_COM_EN_01
Table of Contents
1 INTRODUCTION ................................................................................................................. 6
2 SYSTEM REQUIREMENTS .................................................................................................... 7
2.1 SUPPORTED DIGITAL X-RAY DETECTOR ..................................................................................................... 7
2.2 SYSTEM REQUIREMENTS FOR ACCUVUEMED ........................................................................................... 8
3 OVERVIEW .......................................................................................................................... 9
3.1 PROGRAM START-UP ................................................................................................................................. 9
3.2 MAIN SCREEN OF PROGRAM...................................................................................................................... 11
3.2.1 Function Tabs .................................................................................................................................... 12
3.2.2 Status Display .................................................................................................................................... 13
4 LIST .................................................................................................................................... 16
4.1 WORK LIST .............................................................................................................................................. 17
4.1.1 Main Screen of Worklist .................................................................................................................... 17
4.1.2 Add Examination Window ............................................................................................................... 22
4.1.3 Edit Projection Window ....................................................................................................................25
4.1.4 Edit Window ..................................................................................................................................... 27
4.1.5 Excel Import Window ....................................................................................................................... 29
4.2 STUDYLIST ............................................................................................................................................... 30
4.2.1 Main Screen of the Studylist ............................................................................................................ 30
4.2.2 Merge Window ...................................................................................................................................35
4.2.3 Export Window ................................................................................................................................. 37
4.2.4 Edit Window ..................................................................................................................................... 44
4.2.5 Report Window ................................................................................................................................. 46
4.2.6 Analysis ............................................................................................................................................. 53
4.2.7 Bodypart Editor ................................................................................................................................ 55
5 EXAM .................................................................................................................................. 56
5.1 TOOLBAR ................................................................................................................................................ 59
5.1.1 Toolbar Overview .............................................................................................................................. 59
5.1.2 Edit Toolbar ....................................................................................................................................... 60
5.1.3 Toolbar Icons .................................................................................................................................... 62
5.2 PROJECTION LIST & IMAGE PROCESSING TAB........................................................................................... 66
5.2.1 Projection List ................................................................................................................................... 67
5.2.2 Image Processing Tab ....................................................................................................................... 69
5.3 TRUVIEW ART ......................................................................................................................................... 71
6 CONFIGURATION .............................................................................................................. 73
6.1 DISPLAY .................................................................................................................................................. 75
6.2 SYSTEM ................................................................................................................................................... 75
6.2.1 Language ........................................................................................................................................... 76
6.2.2 Format ............................................................................................................................................... 77
6.2.3 Institution ......................................................................................................................................... 79
6.2.4 Options .............................................................................................................................................. 80
6.2.5 Workflow ............................................................................................................................................ 81
6.3 IMAGE ..................................................................................................................................................... 85
6.3.1 Image Folder ..................................................................................................................................... 85
6.3.2 Delete Option .................................................................................................................................... 86
6.3.3 Overlay .............................................................................................................................................. 88
6.3.4 Import................................................................................................................................................. 91
6.3.5 Truview ART ...................................................................................................................................... 92
6.4 STORAGE ................................................................................................................................................. 93
6.4.1 Delete................................................................................................................................................. 93

AccuVueMED_UM_COM_EN_01
6.4.2 Backup ............................................................................................................................................... 95
6.5 ACCOUNT ................................................................................................................................................ 97
6.6 BLOCK LIST ............................................................................................................................................. 98
6.7 DATASET ................................................................................................................................................. 99
6.8 NETWORK ..............................................................................................................................................100
6.8.1 Local ..................................................................................................................................................101
6.8.2 MWL................................................................................................................................................. 102
6.8.3 PACS ................................................................................................................................................. 104
6.8.4 Printer .............................................................................................................................................. 105
6.8.5 MPPS ................................................................................................................................................ 108
6.9 DETECTOR .............................................................................................................................................109
6.9.1 General ..............................................................................................................................................110
6.9.2 Detailed Configuration by Panel ..................................................................................................... 111
6.10 RIS CODE................................................................................................................................................ 113
6.10.1 Edit RIS Code Window ..................................................................................................................... 114
6.10.2 Add Marker Window ........................................................................................................................118
6.11 PROJECTION EDITOR ...............................................................................................................................119
6.11.1 Projection Editor Window ............................................................................................................... 120
6.12 RECYCLE BIN .......................................................................................................................................... 124
APPENDIX A. GLOSSARY .......................................................................................................................... 126
APPENDIX B. UPDATE .............................................................................................................................. 129
APPENDIX C. STITCHING .......................................................................................................................... 132
APPENDIX D. PORTABLE FUNCTION .......................................................................................................136
APPENDIX E. HOW TO USE ROTATION TOOLS ....................................................................................... 141
APPENDIX F. GAIN CALIBRATION ........................................................................................................... 144

AccuVueMED_UM_COM_EN_01
1 Introduction
AccuVueMED is a complete digital image processing console software specialized for the
digital X-ray detector FLAATZ and EVS series developed by DRTECH Co, Ltd.
AccuVueMED provides the best image processing solution for fine tuned quality images
by integrating with the X-ray generator and the digital detector. AccuVueMED not only
processes the acquired images but also complies with DICOM standards which allow the
user to transmit and receive data with the PACS system and print images through the
DICOM printer.

Figure 1. AccuVueMED Image Processing Workflow (Wired Detector)

Figure 2. AccuVueMED Image Processing Workflow (Wireless Detector)

AccuVueMED_UM_COM_EN_01 6 / 149
2 System Requirements

2.1 Supported Digital X-ray Detector

AccuVueMED supports the following Digital X-ray Detectors manufactured by DRTECH


Co, Ltd.

 FLAATZ 330N

 FLAATZ 500
 FLAATZ 560

 FLAATZ 600 Wireless


 FLAATZ 750E

 FLAATZ 760
 EVS 4343 Series
 EVS 4343 A Series

 EVS 4343 W Series


 EVS 3643 Series
 EVS 3643 A Series

 EVS 3643 W Series


 EVS 2430 Series
 EVS 2430 W Series

AccuVueMED_UM_COM_EN_01 7 / 149
2.2 System Requirements for AccuVueMED

The table provides the minimum recommended specifications for the operating system
that runs AccuVueMED. All specifications are subject to change without notice.

Table 1. Recommended Operating System Specifications

Items Recommended
CPU Intel i5-3470
RAM 8 GB
HDD 500 GB
NVIDIA GeForce
VGA
GT630 1GB
ODD DVD Recorder
Windows 7 Pro
OS 32 / 64bit
Win8, Win10
Display Size 23 inch
Display Resolution 1920 x 1080

* Optimal performance is not guaranteed for PC that does not comply with the recommended specifications.

AccuVueMED_UM_COM_EN_01 8 / 149
3 Overview

3.1 Program Start-up

In order to run the program, double click the [AccuVueMED] icon on the desktop or select
‘AccuVueMED’ from ‘Windows Menu’ – ‘All Programs’ – ‘AccuVueMED’.

Figure 3. AccuVueMED Shortcut Icon

A login window as seen in [Figure 4] will appear if the program is properly initiated.

Figure 4. Login Window

Enter the ID and Password, and click the [Login] icon.

AccuVueMED_UM_COM_EN_01 9 / 149
If you enter an invalid ID or Password, an ‘Error Window’ will appear as shown in [Figure
5] and you will not be able to log in.

Figure 5. Login Error

AccuVueMED_UM_COM_EN_01 10 / 149
3.2 Main Screen of Program

You will see the AccuVueMED main screen as in [Figure 6] after logging in.

Figure 6. Main Screen of the AccuVueMED

a) Function Tabs
b) Status Display

AccuVueMED_UM_COM_EN_01 11 / 149
3.2.1 Function Tabs

Two tab icons can be found on the upper left corner in the main screen as in [Figure 7]

Figure 7. Tab Icons of the AccuVueMED

The functions of these tabs are as follows.

- Manage the Worklist and Studylist.


 Worklist: List of patients.
 Studylist: List of examined studies.
- Refer to 4. List for more details

- Perform X-ray projection of the selected patient in the


Worklist
- Review the examined study of the selected patient in
the Studylist.
- Refer to 5. Exam for more details.

AccuVueMED_UM_COM_EN_01 12 / 149
3.2.2 Status Display

Status display bar can be found on the bottom in the main screen as in [Figure 8].

Figure 8. Status Information Bar

① Hardware & Connection Status Display

Display the status of hardware and the connection status between equipment.

[EVS-2430W Series (Support model only)]


Display the current image transfer option setting of the detector.
(HR : High Resolution / HT : High Transfer)

Display the current acquisition mode set in detector

[FLAATZ-600]
- AED mode
- Switch box mode

[EVS4343, EVS3643, EVS2430]


- AED mode
- Switch box mode
- Sync mode

Click this icon to change the mode. You can change the
default setting using ECali1. (ECali1 - Configuration -
Detector X - Exposure mode)

Mode change sequence.


∙ USB Switch box : USB Switch box <-> AED
∙ Sync Trigger : Sync Trigger <-> AED
∙ AED : AED only

AccuVueMED_UM_COM_EN_01 13 / 149
Display the connection status and the available space left on
the currently connected HDD.
The displayed number indicates the remaining HDD
capacity.
Display the connection status (On/Off) with the X-ray
detector.
[EVS Series]
Display the temperature.
Display the connection status with the Storage Server.
When you click this icon, a pop-up window will appear. You
can change the PACS settings or conduct a test in the new
window. The UI is very similar to the PACS menu of
Configuration. .
Refer to 6.8.3 PACS for more details.

Display the connection status with the DICOM Printer.

Display the connection status with the Modality Worklist


Server.
[Wireless model only]
Display the remaining battery life in the wireless connection.

[Wireless model only]


Battery is in wireless charging.
[Wireless model only]
Display the signal strength of the wirelessly connected
detector.

Display the connection status with the MPPS server.

AccuVueMED_UM_COM_EN_01 14 / 149
② Current Time & Log-in Information Display

 Display the current date, time and user name.


 You can terminate the program by clicking the [Logout] icon.

③ Configuration

 Open the ‘Configuration Window’ for various settings.


 Refer to 6. Configuration for more details.

AccuVueMED_UM_COM_EN_01 15 / 149
4 List
The List tab displays the lists of patients and studies, which can be divided into two
categories as described below.

 Worklist (prior to examination)


 Display the list of patients to be examined.
 You can add/edit/delete patients on the list.
 You can select the patient on the list to proceed with the examination.
 When you run the AccuVueMED Vet for the first time, you will be asked to set the
length of the list. The setting will be saved automatically.
 Refer to 4.1 Work List for more details.

 Studylist (post examination)


 Display the examined studies.
 You can edit and delete the examined studies on the list.
Note: The changes such as editing and deleting images on the list will not affect
the data in the PACS server.
 You can transmit examined images to the PACS server.
 Refer to 4.2 Studylist for more details.

 Please Note!
 The information on the Worklist and Studylist is stored on the Local Storage
(HDD) as default settings.
 Every time AccuVueMED runs, a new Worklist is retrieved from the Worklist
server and stored on the Local Storage.
 Only the contents on the list which are edited and deleted in the AccuVueMED
Vet affect the Local Storage as default. However, edited records may be
transmitted to the PACS server using the ‘Send’ command.

AccuVueMED_UM_COM_EN_01 16 / 149
4.1Work List

Display the list of patients. The list is displayed by clicking the [Work List] icon on the
upper left side of the List tab.

4.1.1 Main Screen of Worklist

The main screen of the Worklist is as seen in [Figure 9].

Figure 9. Worklist Screen

AccuVueMED_UM_COM_EN_01 17 / 149
① List of Patients

 The types of information are as noted in [Table 2].


 The displayed information as well as its order can be set in ‘Configuration’.
 Click or drag the name of the information type (ID,Name,and etc.) to change the
order.

Table 2. Information Type of the Worklist

Type Description
ID Patient ID
Name Patient name
Study Desc. Study Description
Accession Number.
Acc. No.
X-ray study registration number
Date/Time Time of Registration
D.O.B. Date of Birth
Sex Sex of the patient
Order Date Time of order
Operator Radiographer Name
Exam requesting physician’s
Requesting Physician
name

 Patient selection in the Worklist.


 Click the patient to select..
 The selected patient is displayed in blue.
 Patient can be edited and deleted after selection.

 Projection can be performed in the Exam tab by double clicking on the selected
patient.
 You can also click [Exam] icon after selecting a specific patient to perform
projection. Refer to 5. Exam for more details.

AccuVueMED_UM_COM_EN_01 18 / 149
② Search Bar & Refresh Icon

 Search Bar
 Search the entered value such as Patient, ID, Name, and Access Number in the
Worklist (when ‘Modality Query Base’ is selected in Configuration options)
 Search the entered value in the Worklist server that has selected the entered
value as Base. (when ‘Patient Query Base’ is selected in Configuration options)

 If you click the [Search] icon after entering the value to be searched, only
the relevant works will be displayed on the list.

 If you click the [Search] icon without entering a specific value, an


‘Advanced Search Window’ will appear.

AccuVueMED_UM_COM_EN_01 19 / 149
 Advanced Search Window

Figure 10. Advanced Search Window

 Search by specifying multiple options to be searched simultaneously.


 Only the search results that satisfy the entered details will be displayed. .

 Refresh icon
 Retrieve recently registered patients from the PACS server.

AccuVueMED_UM_COM_EN_01 20 / 149
③ Add / Edit / Delete Icon

Table 3. Add/Edit/Delete Icon

Icon Description

Add a new patient.


When clicking the icon, an ‘Add Examination Window’ will appear.
Refer to 4.1.2 Add Examination Window for more details.
Add
Edit the selected patient information in the Worklist.
This function is only available for the patient info which has been
added by Econosole1. When clicking this icon after selecting the
patient, an ‘Edit Window’ will appear.
Edit
Refer to 4.1.4 Edit Window for more details.

Delete the selected patient.


This function is only available for the patient info which has been
added by Econosole1.
Delete

Import the excel file to the Worklist


Refer to 4.1.5 Excel Import Window for more details.
Excel import

Save the patient list in detector.


This function works only with FLAATZ600, EVS3643 and EVS2430
W. The CR Mode of the EVS2430W is available through this portable
function of AccuVueMED.
Portable
Refer to Appendix D. Portable Function for more details.

④ Exam

 Switch to the Exam tab for examination of the selected patient.


 Refer to 5. Exam for more details.

AccuVueMED_UM_COM_EN_01 21 / 149
4.1.2 Add Examination Window

An ‘Add Examination Window’ appears when clicking the icon as shown in


[Figure 11] below.

Figure 11. Add Examination Window

AccuVueMED_UM_COM_EN_01 22 / 149
① Patient Information

Patient information is entered according to the category described in [Table 4].

Table 4. Patient Information (Add Examination Window)

Category Description
ID Patient ID
Accession Number Registered identification number
Name Patient Name
Operator Radiographer Name
Gender Gender of the patient
Birth Date Date of birth of the patient
Age Age of the patient (Year / Month selection available)
RIS Code RIS Code to be used for examination
Requesting Physician Exam requesting physician’s name

② Emergency

 When clicking this icon, the default values are automatically entered as ID and
Accession Number and it switches to the Exam tab.
③ Projection Information

 Display the information related to projection


 No information is provided initially. Set the projection information by clicking
registered RIS code or [Edit] icon(④).
④ Edit

 Open an ‘Edit Projection Window’ where projection information can be entered.


 Refer to 4.1.3 Edit Projection Window for more details.
⑤ OK

 Save the patient with the entered information and close the window.
⑥ Exam

AccuVueMED_UM_COM_EN_01 23 / 149
 Save the patient with the entered information and directly switch to the Exam tab for
examination.
 Refer to 5. Exam for more details.
⑦ Cancel

 Cancel the work and close the window.

* Please Note!

If multiple projections are registered for a single patient, each projection receives a
different Accession Number [Figure 12].

Figure 12. Multiple Projections Registration in a Single Event

Click the [OK] icon to register each projection for two separate studies in the Worklist
as seen in [Figure 13]

Figure 13. Two studies for one patient

AccuVueMED_UM_COM_EN_01 24 / 149
4.1.3 Edit Projection Window

The ‘Edit Projection Window’ will appear when clicking the [Edit] icon.

Figure 14. Edit Projection Window

① Anatomy Information

 Select the anatomical region to be examined.


 Projection and Position are determined based on the selected anatomical region.
 Receptor Type will be changed by clicking the icons below

Stand Table Wireless1 Wireless2 Wireless3

AccuVueMED_UM_COM_EN_01 25 / 149
② Projection & Position List

 Specific projection as well as position selection in the region selected in Anatomy.

③ Add

 Register the currently set Projection, Position, and Receptor Type information.
 The currently set Projection, Position and Receptor Type are also registered
when clicking the selected Position.

④ Registered Projection Information

 Display the list of registered Projection, Position and Receptor Type.


 The Receptor Type can be changed by double clicking the Position in Dual Mode.

⑤ Projection Information Sequence Edit Icon

 Change the order of projections on the list.

Up Down
⑥ Delete

 Delete the selected item.

⑦ OK

 Save and close the window.

⑧ Cancel

 Cancel and close the window.

AccuVueMED_UM_COM_EN_01 26 / 149
4.1.4 Edit Window

The ‘Edit Window’ will appear when selecting a study from the Worklist and then clicking
the [Edit] icon.

Note: The ‘Edit Window’ is not activated if the study information is retrieved from the
PACS server.

Figure 15. Edit Window

AccuVueMED_UM_COM_EN_01 27 / 149
① Study Information

 Edit the information of the radiographer(s) and the patient(s).


 The study information described in [Table 5] below is entered.

Table 5. Study Information (Edit Window)

Category Detail
ID Patient ID
Name Patient Name
Accession Number Registered Identification Number
Operator Radiographer Name
Study Description Study Description
Sex Sex of the Patient
Birth Date Date of Birth of the Patient
Age Age of the Patient (Year/Month Selection Available)
Schedule date & time Scheduled date and time of imaging
Requesting Physician Exam requesting physician’s name

② OK

 Save changes and close the window.

③ Cancel

 Cancel changes and close the window.

AccuVueMED_UM_COM_EN_01 28 / 149
4.1.5 Excel Import Window

① Create a patient list

 Use the template found at 'installed path\ Config\Worklist_sample.xlsx' to create a


patient list.

② Limitation

 You can select the patient’s sex among the 'M', 'F', and 'U'.
 The format of Birth Date and Study Date is 'MM/DD/YYYY'. Any other format is not
provided.
 The format of Birth Time and Study Time is 'HH:MM:SS'. Any other format is not
provided.

③ Excel import

 Click the [Excel Import] and load the file.

AccuVueMED_UM_COM_EN_01 29 / 149
4.2 Studylist

Display the examined study list. When clicking the [Study List] icon on the upper side of
the screen, the study list will be activated.

4.2.1 Main Screen of the Studylist

The main screen of the Studylist is displayed as seen in [Figure 16].

Figure 16. Main Screen of the Studylist

① List of the Examined Patients

 Display the list of examined patients’ information.


 Each row represents the information of one patient and one ID can have multiple
studies.
 The column of the list can be changed by dragging the names of the categories
(e.g. ID, Name, and etc.).

AccuVueMED_UM_COM_EN_01 30 / 149
 Height of the list is adjustable using [Ctrl key] + Mouse wheel or using [Ctrl key] +
[Arrow key].
 Types of information are as noted in [Table 6].

Table 6. Information Types of Patient

Category Description

Name Patient name

ID Patient ID

Sex Sex of the patient


D.O.B. Date of Birth
Date/Time Date / time for recent examined study

 Patient Selection
 Patient can be selected by left-clicking. .
 The selected patient is highlighted in blue. In the ‘① Examined Patient List’ and
‘② Examined Study List per Patient’, an activated study is highlighted in darker
color, while an inactivated study is highlighted in lighter color.
 The selected patients can be edited or deleted.

② Examined Study List per Patient

 Display detailed study information of the selected patient on ‘① List of the Examined
Patients’.
 Types of information are as noted in [Table 7].

AccuVueMED_UM_COM_EN_01 31 / 149
Table 7. Information Types of Examined Study List

Items Description
Acc. No. Accession Number. Registered Identification Number
Study ID RIS code
Study Desc. Study Description
Status [Number of images] / [Number of projections]
Date/Time Date / Time for examined study
PACS [Number of images transmitted] / [Number of projections]
Printer [Number of images printed] / [Number of projections]
Report Report documentation
Operator Radiographer Name
Requesting Physician Exam requesting physician’s name
③ Thumbnail

 Display the images from the selected patient.


 A check mark is added to the thumbnail of the selected images, for opening or
transmitting the images
 The thumbnail can be selected by double-clicking on it.
 Images transmitted to the PACS server are shown in green outlines.
 1/1 : Series number / Image number
④ Search Bar & Refresh Icon

 Search Bar
 Search the values of Patient ID, Name, and Access Number within the Studylist.

 If you click the search icon after entering the value to be searched, only
the relevant works will be displayed on the list.

 Refresh Icon

AccuVueMED_UM_COM_EN_01 32 / 149
⑤ Tool Icons

Table 8. Studylist Icons

Icon or Button Description


Open detailed overview of a single selected image from the list
of thumbnails.
Open Study Refer to 5. Exam for more details.

Repeat exam for the selected study in the Exam tab.

Repeat Exam Refer to 5. Exam for more details.

Perform merging two images or studies.

Merge Refer to 4.2.2 Merge Window for more details.

Stores images on a USB, CD, or DVD, and print through the


DICOM Printer.
Export Refer to 4.2.3 Export Window for more details.
Edit the selected patient or study information in the Studylist.
The ‘Edit Window’ appears when clicking the [Edit] icon.
Edit Refer to 4.2.4 Edit Window for more details.

Delete the selected item.


Delete

Save the patient list in an EXCEL file format


EXCEL Export

Make the selected series report.

Report Refer to 4.2.5 Report for more details.

Display the statistics of exams during the selected period

Statistics Refer to 4.2.6 Analysis for more details.

Body part and position editor. Change and apply exam

Bodypart Editor information at study list. Refer to 4.2.7 Bodypart Editor

AccuVueMED_UM_COM_EN_01 33 / 149
⑥ Send

 Transmit the selected images to the PACS server.

AccuVueMED_UM_COM_EN_01 34 / 149
4.2.2 Merge Window

 Merge the images and studies.


 If a patient has multiple ‘Patient ID’, it is more convenient to group them by using this
function. Edit if the image and patient information do not match with each other.

Figure 17. Merge Window

① & ② Merge Subject Imaging Information

 Study lists appear on each side. (One page only shows 100 items.)
 Required items can be easily searched by using the search tool.
 Identical items selected in ① will be also located in ② if the same list is checked.
 You can view the list of taken jobs, detailed list of shooting, and thumbnails at a
glance.
 If ‘Show worklist’ is selected, patient list information is displayed in ①. You can merge
the images by selecting the patient on the patient list.

AccuVueMED_UM_COM_EN_01 35 / 149
③ Merge Icon

 Transmit the selected items.


 Every change is saved while being transmitted.

④ Close

 Close the ‘Merge Window’.

AccuVueMED_UM_COM_EN_01 36 / 149
4.2.3 Export Window

Save the images of the selected study from the Studylist in a USB, CD, DVD, or PDF and
print it through the DICOM Printer.

4.2.3.1 Drive

Figure 18. Export drive Screen

 Store the images in the local drive.


 Only the files in DCM, BMP, JPG, PNG, and TIF format can be exported.
 If a local drive is selected, the current lists of stored files are displayed.
 New folders can be created by right clicking the mouse after selecting the designated
Drive.
 Export File Format
 Select the file format for storage.
 Image is stored in a USB when clicking the [OK] icon
 File name is automatically designated and it will be stored in 'Selected
folder/Patient ID/Acc No/' folder.

AccuVueMED_UM_COM_EN_01 37 / 149
4.2.3.2 Print

Figure 19. Export - Print Screen

 Print through the DICOM Printer.


 The DICOM Printer must be connected.

① Print Setting

 Printer Selection
 Select a DICOM Printer.
 Register the Printer using 'Config' - 'Network' - 'Printer' menu.
 Film Orientation
 Select a film orientation between portrait / landscape.
 Film Size
 Select the size of the film.
 Layout
 Set the print layout.

AccuVueMED_UM_COM_EN_01 38 / 149
 The [Divide] icon must be clicked in order to apply any changes made in the
Layout.
 Zoom
 Perform zoom in/out of the image.

② Preview

 Thumbnail
 The image to be printed appears in the thumbnail list on the right.
 Preview
 If an image is selected in the thumbnail, a large image appears in the center as a
preview screen.
 Merge
 Merge the divided screen which has been separated by the ‘Divide’ function.
 Only adjacent screens of the same sizes can be merged
 The merged shape must be a square.
 Divide
 Divide the screen by the value set in ‘Layout’.
 Rotation
 Rotate the screen 90 degrees clock-wise.
 Flip
 Reverse the up and down sides.
 Print
 Print out using general printer.
 100%
 Perform paper printing in the actual object size.
 Fit to Screen
 Perform paper printing according to the screen size.

③ DICOM Print

 Perform printing with the DICOM Printer.

AccuVueMED_UM_COM_EN_01 39 / 149
4.2.3.3 CD / DVD

Figure 20. Export - CD / DVD

 Store the images on a CD or DVD.


 Only DICOM files can be exported.
 A CD/DVD Writer is required.

① CD / DVD Media Configuration

 Select the target media to be exported.


 CD and DVD can be used.
 Volume Label
 Set the name of the target media.
 Total Space
 Display the total available space of the target media.
 Insert
 Close the CD / DVD Writer.

AccuVueMED_UM_COM_EN_01 40 / 149
 Eject
 Eject the tray of the CD / DVD Writer.

② Export File List

 Display the list of files to be exported.

③ Export Process

 Estimated Time
 Present the expected time needed for Export.
 Time Left
 Display the estimated time left to the completion of Export.

④ Task Icons

 Burn
 Perform the Export task.
 Cancel
 Cancel the Export task.

AccuVueMED_UM_COM_EN_01 41 / 149
4.2.3.4 E-Mail

Figure 21. E-mail

① Address Book

 Select E-mail address and double-click to populate the “To:” field automatically.
 User can add or edit or delete addresses using add, edit, delete button.

② To

 Adds the recipient E-mail address.


 If you want to add more than 1 recipient, use ';' delimiter.

③ Subject

 Adds the E-mail subject.

④ Body

 Adds the E-mail text.

AccuVueMED_UM_COM_EN_01 42 / 149
⑤ Account

 Add or Edit sender's E-mail account.


 E-mail account must be a gmail.com address
 E-mail account credentials are encrypted in the database.

Figure 22. E-mail

⑥ Sending status

 It shows sending status.

⑦ Sending image choose

 Select the sending image.

⑧ Send or Cancel

 Images are converted to JPG format before sending.

AccuVueMED_UM_COM_EN_01 43 / 149
4.2.4 Edit Window

4.2.4.1 Edit Patient Information

Figure 23. Edit Window in Studylist (Patient Information)

 Only the patient information (ID, Name, Sex, Birth Date, and Age) can be edited when
clicking the [Edit] icon in the patient list of the Studylist (upper part of the list).
 OK
 Save and close the window.
 Cancel
 Cancel and close the window.

AccuVueMED_UM_COM_EN_01 44 / 149
4.2.4.2 Edit Study Information

Figure 24. Edit Window in Studylist (Study Information)

 Only the study information (Accession Number, Study Description, Requesting


Physician and Schedule date & time) can be edited when clicking the [Edit] icon in the
projection list (lower part of the list) of the Studylist.
 OK
 Save and close the window.
 Cancel
 Cancel and close the window.

AccuVueMED_UM_COM_EN_01 45 / 149
4.2.5 Report Window

4.2.5.1 Report
Create a report using the Report button in the StudyList.

Figure 25. Create Report

① Patient and Exam information

 Check or change the patient information of the selected series.


② Attached image

 The User can attach up to 4 images using the 'Image load' button.

AccuVueMED_UM_COM_EN_01 46 / 149
③ Write opinion

 The User can write an opinion.


④ Review / Print / Save as PDF / Save / Send / Setting

 Review can review report. (Mark as reviewed)


 The User can print the report.
 Save a report as PDF file.
 Save a report.
 Report can be sent in DICOM format to the designated PACS.
 Set the report format.
4.2.5.2 Image load

Figure 26. Create Report

 Layout button
 Select 1X1, 1X2, 2X2 layout.

AccuVueMED_UM_COM_EN_01 47 / 149
 Image load button
 Select an image
 OK / Cancel button
 Attach the selected image to the report / Cancel and close image load window.
4.2.5.3 Select the image

Figure 27. Select the image

 You can select the image when clocking "Image load" button
 Search area
 Search the patient
 Patient/Series/Image list
 Select an image.
 OK button
 Load the selected patient`s image.
 Cancel button
 Cancel to load the image.

AccuVueMED_UM_COM_EN_01 48 / 149
4.2.5.4 Input the opinion

Figure 28. Input the opinion

 Input the opinion on the selected series of images.

AccuVueMED_UM_COM_EN_01 49 / 149
4.2.5.5 Set report form

Figure 29. Set report form

 The User can set the report form using the 'setting' menu.
 Address/ Extra Info
 Input the Hospital address or further information.
 Session
 Input the titles of each Session.
 Visible setting
 Select the contents of the report to be printed.
 All items are selected as default.
 Save as default button
 Save the current setting as default.
 OK button
 Use the selected form.
 Cancel button
 Cancel the selected form.

AccuVueMED_UM_COM_EN_01 50 / 149
4.2.5.6 Print

Figure 30. Print

 Print the report using the [Print] button.

4.2.5.7 Save as PDF

Figure 31. Save the report as a PDF file

 Click the [Save PDF] button to save the path and file name as a PDF file.

AccuVueMED_UM_COM_EN_01 51 / 149
4.2.5.8 Export of DCM report

 DCM report is created when the send button is clicked. The created DCM report
is then sent to PACS.
 The report can be found and viewed on the PACS.

AccuVueMED_UM_COM_EN_01 52 / 149
4.2.6 Analysis

You can check the shooting statistics (number of captured patients, number of shots,
number of regas, number of PACS transmissions, number of prints, etc.) during the set
period.

Figure 32. Statistics

① Statistical results

 Date based analysis


 Show the shooting statistics by date.
 User Account Based Analysis
 Show statistics by patient.
 Reject code based analysis
 Show statistics by Reject code.

AccuVueMED_UM_COM_EN_01 53 / 149
② Period setting

 Set the period for which statistics are recorded.

③ Search and Export

 Search
 Show the statistics according to the set period.
 Export
 Save the statistics according to the set period as an Excel file.

④ Analysis by rejected code

 Show the statistics of reject code by type

⑤ Analysis by projection

 Show the statistics of all projected positions

AccuVueMED_UM_COM_EN_01 54 / 149
4.2.7 Bodypart Editor

Apply body part position and information at study list.

Figure 33. Body part editor

① Patient information

 Possible to change information of selected patient.


② Images

 Select image of patient and select body part from ③Body part position for change
body part
③ Body part position

 Select body part, it will change body part of selected image.


④ OK & Cancel

 Click OK button to apply changes and Click Cancel button to cancel changes.
 If click OK, changed information, Body part and image parameter will apply to select.

AccuVueMED_UM_COM_EN_01 55 / 149
5 Exam
The Exam tab processes the exam and edits images.
* Review mode is same as Exam tab bun cannot process exposure.

Figure 34. Main Screen of Exam Tab

① Patient Information

 Display ID, patient name, and study description.

② X-ray Detector Status Display and Suspend

 Display the status of the detector to be used for exam.


 READY: The state where shooting can start
 BUSY: The acquisition is being performed or the detector is being ready for the next
shooting
 FLATTENING: Status in preparation for shooting
 SLEEP: Weak sleep mode
 DEEP SLEEP: Strong sleep mode

 : Pauses the current patient’s imaging session and the screen is returned to

AccuVueMED_UM_COM_EN_01 56 / 149
the patient list. The patient information currently in session is highlighted in orange on
the patient list.

③ Image Display Screen

 Area - display images.


 To adjust window leveling base on mouse pointer nearby area, CTRL + Double click.
(This will adjust window leveling base on pointed area nearby.)

④ Toolbar

 Collection of image editing icons


 The width of the column can be adjusted.
 Refer to 5.1 Toolbar for more details.

⑤ Projection List & Image Processing Tab

 View the list for images, or set the post-processing parameters which will be applied
to the images.
 Refer to 5.2 Projection List & Image Processing Tab for more details.

⑥ Generator Condition Setting

 Some settings are only available when integrated with X-ray generator.
 Tube Voltage (kVp), Tube Current (mA), Tube Current Amount (mAs) setting.
 When clicking the tube current amount icon (mAs), the unit can be changed to
exposure time (seconds).
 Patient Size
 Select the volume of the patient‘s body.
 The values of the tube current, tube voltage and tube current amount are
renewed subsequent to the patient’s volume.
 AEC
 Set the AEC to be used.
 Density

AccuVueMED_UM_COM_EN_01 57 / 149
 Configure the imaging density.
 Focus
 Configure the Focal Size.
 Grid
 Configure the applied Grid.

⑦ Save / Indicator / Finish / Send

 Save
 Store the images on the Local Storage.
 Finish
 Save the captured (or edited) image to Local Storage and automatically move to
the list screen.
 Send
 Transmit the images to the PACS server.
 If long-clicking the icon, all the images that have been acquired or edited are
transmitted to the PACS server.
 Indicator Icon

Standby Ready Exposure

 Standby: Default status. Exam can start..


 Ready: Ready for the detector to acquire image.
 Exposure: Emit x-ray to the detector.

AccuVueMED_UM_COM_EN_01 58 / 149
5.1 Toolbar

Collection of the icons to analyze and edit

5.1.1 Toolbar Overview

① Toolbar Width Adjustment Icon

 Adjust the width of the toolbar.


 The width can be set from 1 to 4.

② Tools List

 Display the currently configured list of icons.


 The icons can be edited in the ‘Edit Toolbar Window’.

③ Edit

 Open the ‘Edit Toolbar Window’ to edit the icons.


 Refer to 5.1.2 Edit Toolbar for more details.

AccuVueMED_UM_COM_EN_01 59 / 149
5.1.2 Edit Toolbar

Figure 35. Edit Toolbar Window

① Applied Icons Box

 The currently applied icons in the Exam tab are displayed in this box.
 Icons in this box can be deleted by dragging & dropping the icon into ‘② Tools
Collection’ on the right.
 Icons can be added into this box by dragging icons in ‘② Tools Collection’ and
dropping it on any empty location.
 When the horizontal width of the Toolbar changes from 1 to 4, the column will be
visible from the left.

AccuVueMED_UM_COM_EN_01 60 / 149
② Available Icons

 All the available image editing icons are listed.


 Icons can be added in ‘① Applied Icons Box’ by dragging & dropping the icons.
 The icons that have already registered in the icon list appear dark.

③ Add Shutter Icon

 Add the icons with ROI Shutter Sizes specified by the User.
 The following window appears when clicking the icon.

Figure 36. Add Sutter Size Window

 Enter the size (Width and Height) and click [OK] to add a new ROI.

④ Shutter Delete Icon

 Delete the Shutter size added by the User only.


 Shutter icon that have been added can be deleted by dragging and dropping it on the
trash box icon

⑤ OK

 Apply the modified tool arrangement and close the window.

⑥ Cancel

 Cancel and close the window.

AccuVueMED_UM_COM_EN_01 61 / 149
5.1.3 Toolbar Icons

The functions of all the icons in the toolbar are described in [Table 9].
For more details about certain tools, please refer Appendix E.

Table 9. Toolbar Icons

Icon Description

Set the ROI size to 8×10

Set the ROI size to 10×12

Set the ROI size to 14×17

Set the ROI size to 17×17

Set the ROI size to the user specified size

Set the ROI into a square shape

Set the ROI into a circular shape

Display the “R" marker on the screen

Display the "L" marker on the screen

Display the "ERECT" marker on the screen

Display the "SUPINE" marker on the screen

Display the "SITTING" marker on the screen

Display the "STRESS" marker on the screen

Display the text entered by the User on the screen


(Check box checked items are added to tool bar)

Display the "PA" marker on the screen

Display the "AP" marker on the screen

AccuVueMED_UM_COM_EN_01 62 / 149
Display the "OBL" marker on the screen

Display the "LAT" marker on the screen

Display the "FLEX" marker on the screen

Display the "EXT" marker on the screen

Display the "↑" marker on the screen

Display the "←" marker on the screen

Display the "↓" marker on the screen

Display the "→" marker on the screen

Arrange windows side-by-side symmetrically

Arrange windows up-and-down symmetrically

Rotate the image 90 degrees clockwise

Rotate the image 90 degrees counter-clockwise

Zoom-in and out of the image by using left mouse button drag.

Fit image to screen

Partially expand the image

Move the image by using left mouse button drag

Display the screen in 1×1

Display the screen in 2×1

Display the screen in 1×2

Display the screen in 2×2

AccuVueMED_UM_COM_EN_01 63 / 149
Measure the length of the image

Measure the angle of the image

Verify the DICOM Header information

Delete any annotation or markers indicated on the image using other


tools

Adjust the window level and width of the image

Invert the image

Stitch images

Capture the image.

Print the image.

Reset the edited image into its initial form

Delete the image

Ruler calibration

Duplicate the image

Change mouse sensitivity

Run the dark scan manually(EVS-4343, EVS-3643 only)

Draw ellipse annotation

Draw rectangle annotation

Draw polygon annotation

Draw free line annotation

Draw arrow annotation

AccuVueMED_UM_COM_EN_01 64 / 149
Select annotation

Add Free Text Annotation

Add VHS Annotation

Fit image to real pixel size

Activates Truview Binning

Displays grid pattern on the image

Retrieves images acquired with portable mode


(only for detectors supporting this function)

Adjusts the size of Free Text Annotation

Activates TPLO measurement tool (Only for AccuVueMED Vet)

Activates TTA measurement tool (Only for AccuVueMED Vet)

Activates Noberg measurement tool (Only for AccuVueMED Vet)

Cobb`s Angle tool. Measure angle between 2 lines.

Display the screen in 3×3

Display the screen in 4×4

Window leveling adjust with selected area`s window leveling average

Free angle image rotate tool (Draw angle will rotate image)

Free area image crop and rotate (Draw rectangle will crop image)

AccuVueMED_UM_COM_EN_01 65 / 149
5.2 Projection List & Image Processing Tab

The Projection List & Image Processing Tab can be used through the tab icon on the
upper right corner.

Figure 37. Projection List (Left) & Image Processing Tab (Right)

AccuVueMED_UM_COM_EN_01 66 / 149
5.2.1 Projection List

Display a list of studies categorized by projections.

Figure 38. Projection List Tab

① & ④ Projection and Position

 Projection can be selected by clicking ① icon.


 ④ presents the available positions of the selected projection.
 It allows verification of thumbnails, position designations, and Receptor type.

POP-UP function

 When right clicking, you can change the options.


 ROI Marker visible: Set the use of ROI and Marker of the positions that are set as

AccuVueMED_UM_COM_EN_01 67 / 149
default when receiving the image from the detector.
 Find auto position
∙ All projection: Find unexposed position among the all projections when you save or
send an image.
∙ One projection: Find unexposed position in the selected projection when you save
or send an image.
∙ Do not apply: do not find unexposed position when you save or send an image.
 Auto Save
∙ Use : Enable auto save. If enabled, image will auto saved according to time interval
when exposure end.
∙ Time setting : Set the time interval for image auto save after exposure.
 RIS Code Save/Update : Update RIS code to current exposure list. If no RIS code,
create new RIS code using current exposure list.
 Position info. Update : Update position information according to current position`s
information. (Marker / rotation / flip / bucky type)

② Projection Guide

 The projection guide for the selected projection.

Figure 39. Projection Guide

 Left-click to close the presented projection guide.


③ Edit Projection

 You can edit the shooting list.


 Refer to 4.1.3 Edit Projection Window for more details.

AccuVueMED_UM_COM_EN_01 68 / 149
5.2.2 Image Processing Tab

* Function for advanced users *


 It is utilized to acquire a more optimized image by adjusting the post-processing
parameters of the completed image.

Figure 40. Image Processing Tab

① Histogram

 Display the histogram of the currently selected image.


 Auto WL: Set the window level automatically.

AccuVueMED_UM_COM_EN_01 69 / 149
② Image Enhancing Parameters

 Adjust the image enhancing parameters.


 The adjustable parameters are as noted in [Table 10].

Table 10. Image Enhancing Parameters

Image Processing Description


Contrast Adjust the contrast
Edge Adjust the Edge
Mask Adjust the Mask
Brightness Adjust the Brightness
Smooth Adjust the Smooth

③ Parameter Functions

 Wizard
 Open the multi-image viewer window.
 8 types of images are shown based on the currently set parameter.
 Apply
 Apply the currently set parameters to the image.
 Reset
 Reset the parameter to its initial setting.
 Save
 Save the currently set parameters and apply them when performing the projection
of the relevant projection-position.

AccuVueMED_UM_COM_EN_01 70 / 149
5.3 Truview ART

* Function for advanced users *


 It works only EVS series detector for image sharpness

Figure 41. Truview ART Tab

① Use TRUVIEW ART


 Default : "OFF".
 If you set "ON", it will be adjusted selected image.

② Magnified screen
 It magnifies selected position in the image viewer.

AccuVueMED_UM_COM_EN_01 71 / 149
 You can magnify the certain area by double clicking the area.

③ Compare
 Compare the two images with and without applying Truview ART.
 2 images will appear. Left image is not adjusted by TRUVIEW ART, and Right image
is adjusted by TRUVIEW ART.

④ Save
 Save TruviewART enable / disable status to parameter.

AccuVueMED_UM_COM_EN_01 72 / 149
6 Configuration
Configure the user settings of AccuVueMED.

 Administrator privileges are required for configuration.


 Contents of configuration are saved and applied immediately following any changes
made.

Categories of Configuration are as noted in [Table 11].

Table 11. Configuration Category

Category Description

The tab (List/Exam) of AccuVueMED may be viewed


simultaneously by division depending on the number of
Display
connected monitors, and performs relevant configurations.
Refer to 6.1 Display for more details

Configure language, date display, hospital information and


System etc.
Refer to 6.2 System for more details.

Configure image storage folder, delete policy, annotation


Image information and etc.
Refer to 6.3 Image for more details.

Set configuration related to PC Storage (HDD).


Storage
Refer to 6.4 Storage for more details.

Manage the accounts of AccuVueMED users


Account
Refer to 6.5 Account for more details.

AccuVueMED_UM_COM_EN_01 73 / 149
Configure unnecessary RIS code filtering subsequent to
Blocked
ultrasound or other devices.
List
Refer to 6.6 Block List for more details.

Configure the DICOM Header Format.


Dataset
Refer to 6.7 Dataset for more details.

Configure the network information, such as Local, PACS,


Network Printer and etc.
Refer to 6.8 Network for more details.

Configure the Detector which will be connected with the


Detector AccuVueMED.
Refer to 6.9 Detector for more details.

Configure the RIS Code.


RIS Code
Refer to 6.10 RIS Code for more details.

Configure projection and position.


Projection
Refer to 6.11 Projection Editor for more details.

Recycle Configure deleted images


Bin Refer to 6.12 Recycle Bin for more details.

Generator Not use. Will be deleted.

AccuVueMED_UM_COM_EN_01 74 / 149
6.1 Display

 Display mode will be added soon.

Figure 42. Display Configuration

6.2 System

 Perform configurations affecting the overall AccuVueMED.

Subcategory Description
Language Select system language.
Format Select date and name format.
Institution Enter the information of the institution.
Enable and disable automatic running of AccuVueMED
Options
at startup of Windows.
Workflow Set miscellaneous function.

AccuVueMED_UM_COM_EN_01 75 / 149
6.2.1 Language

Figure 43. Language Configuration

 Configure the system language.


 DICOM character set
Note that DICOM character set is defined separately from system language. It is set by
the language that was chosen when installing the program.
Items DICOM character set
Korean \ISO 2022 IR 149
Chinese GB18030
Japanese ISO 2022 IR 13\ISO 2022 IR 87
Default ISO_IR 100
Turkish ISO_IR 148
Thai ISO_IR 166
Ukrainian,
ISO_IR 144
Russian
UTF-8 ISO_IR 192
Japanese \ISO 2022 IR 87

AccuVueMED_UM_COM_EN_01 76 / 149
6.2.2 Format

Figure 44. Date Configuration Screen

 Configure the date format.


 Date
 Y: Year , M: Month, D: Day
 Delimiter
 Set the symbol to be used between Y, M, and D.
 For example, If today is May 31st, 2012

Date Delimiter Final Notation


MM DD YYYY / 5/31/2012
MM DD YYYY - 5-31-2012
MM DD YYYY . 5.31.2012
YYYY MM DD / 2012/5/31
MM DD YY - 5-31-12
YY MM DD . 12.5.31

AccuVueMED_UM_COM_EN_01 77 / 149
 Enable Name Format
 Name format configuration is available when this checkbox is checked.
 Name Order
 Alphabetic
 Ideographic
 Phonetic
 Name Use Option: Select the type of name to use. At least one option should be
selected.
 Last Name
 First Name
 Middle Name

AccuVueMED_UM_COM_EN_01 78 / 149
6.2.3 Institution

Figure 45. Institution Configuration

 Input the hospital/institution information using the AccuVueMED.


 Hospital
 Hospital Name
 Department
 Department name of the hospital.
 Station Name
 The name of projection station that is used at the hospital

AccuVueMED_UM_COM_EN_01 79 / 149
6.2.4 Options

Figure 46. Options Configuration

 Auto Start
 If checked, AccuVueMED will automatically start when Windows starts.
 Not available on Win8.
 Virtual Keyboard
 If checked, virtual keyboard will be available for use.

AccuVueMED_UM_COM_EN_01 80 / 149
6.2.5 Workflow

Figure 47. Workflow Configuration Screen

 Use input exposure dose data manually


 If checked, you can enter the dose information manually.
 Use of automatic ID generation option
 If checked, patient ID is generated automatically
 ID generation rule
 ID is created based on the creation date.
 Y: Year , M: Month, D: Day
 Identifier
 Select an identifier to be combined with the ID generated based on the creation date.
 Time : Based on patient generation time
 Automatic Sequencing: Generated in sequence according to the ID generation order

AccuVueMED_UM_COM_EN_01 81 / 149
Example) Patient ID Generation on May 31st 2012 at 23:45

Generation
Identifier ID Generation Example
Rule
YYMMDD Time 120531112345
MMDDYY Automatic Sequencing 120531000001
DDMMYY Time 310512112345
YYYYMMDD Automatic Sequencing 20120531000001
MMDDYYYY Time 05312012112345
DDMMYYYY Automatic Sequencing 31052012000001

 Send all images to server


 If checked, when sending 2 or more images to the server, all images are sent to the
server.
 Remove unexposed projection
 If checked, projections which were unexposed during the imaging session are
deleted.
 Quick Exposure Mode
 Use quick exposure mode : activate quick exposure mode. Please refer 6.2.5.1
Quick exposure mode(Add patient) and 6.2.5.2 Quick exposure mode (exam)
 Use default parameter : Apply default image parameter when exposure via quick
exposure mode

AccuVueMED_UM_COM_EN_01 82 / 149
6.2.5.1 Quick exposure mode (Add patient)

 Exposure mode and exam sequence will changed when activate quick exposure
mode.

Figure 48. Quick exposure mode (Add patient)

① Quick Exam
 Originally located EMERGENCY button will replaced to QuickExam button.
 Click QuickExam button to enter Quick exposure. Quick exposure has no position
and patient information.(Added patient`s information, position and other information
will filled “UNKNOWN”)

② EMERGENCY
 Originally EMERGENCY button moved to work list.
 For exposure EMERGENCY patient, no need to enter add patient window.

AccuVueMED_UM_COM_EN_01 83 / 149
6.2.5.2 Quick exposure mode (exam)

 More quickly exposure will possible when entering exam window with QuickExam.

Figure 49. Quick exposure mode (exam)

 After using quick exposure mode, PACS sending function will not work till change
patient`s information. (correct position and patient name will need to send image to
PACS)
 To change information of quick exposure study, recommend 4.2.7 Bodypart Editor to
change information. 4.2.7 Bodypart Editor is more easily and fast.

AccuVueMED_UM_COM_EN_01 84 / 149
6.3 Image

 Allow configuration relevant to examined images.

Subcategories Description
Image Folder Set the location to save the images.
Delete Option Set delete options for image files.
Overlay Set overlay on the images.
Import Import images to the Studylist.
Truview ART Enable or disable the Truview ART feature

6.3.1 Image Folder

Figure 50. Image Folder Configuration

 Set the location to save the images in the operating PC.


 Edit

AccuVueMED_UM_COM_EN_01 85 / 149
 Open the folder selection window.
 Select the folder where the images are to be stored.
(The folder path to save the images must be set to Drive: \Images\)
 Save Raw DICOM automatically
 If checked, Raw DICOM is created automatically when acquired images are saved.

6.3.2 Delete Option

Figure 51. Delete Option Configuration

① Image Delete Option

 Use Password
 If checked, deletion of image requires a password.
 Use Reject Code
 If checked, a reject code (reason for deletion) is required whenever attempting to
delete an image file.

AccuVueMED_UM_COM_EN_01 86 / 149
 Use Recycle Bin
 If checked, recycle bin function is activated.

② Reject Code

 List of reasons for deletion.


 Statistics
 Display the statistical record of each applied Reject Code.
 The statistics can be exported to the Microsoft Excel file when clicking the [Export]
Icon on the statistics display window.
 Delete
 Delete the selected Reject Code from the list.
 Add
 Add a new Reject Code.
 Edit
 Edit the selected Reject Code.

AccuVueMED_UM_COM_EN_01 87 / 149
6.3.3 Overlay

 Allow overlay configuration.

Figure 52. Overlay Configuration

 Edit types of overlay to be displayed on the top left, top right, bottom left and bottom
right of the images.
 The editing method is the same while the displaying locations differ.

Figure 53. Edit Overlay

AccuVueMED_UM_COM_EN_01 88 / 149
① Registered Overlay Type & Font Size

 Overlay: Information which will be displayed.


 Size: Font size of the relevant information.
 Information is displayed in accordance with the arrangement on the list.

② Edit Icon


 Add a new overlay to the list.
 The following window as shown in [Figure 50] appears when clicking the icon.

Figure 54. Overlay Option

 The selected overlay is added after entering the size and clicking [OK].
 The Texts that have already been registered will be displayed in black.

AccuVueMED_UM_COM_EN_01 89 / 149

 Delete the selected annotation from the list.


 The selected annotation moves up by one row.


 The selected annotation moves down by one row.


 Change font size of each location.

AccuVueMED_UM_COM_EN_01 90 / 149
6.3.4 Import

Figure 55. Import Configuration Screen

 Import an external image into the Studylist.


 Import
 Open the file selection window.
 Select the image to be imported.

AccuVueMED_UM_COM_EN_01 91 / 149
6.3.5 Truview ART

Figure 56 Truview ART Configuration

 Set the scope for applying TRUVIEW ART

AccuVueMED_UM_COM_EN_01 92 / 149
6.4 Storage

 Configurations concerning the deletion and storage of data in the operating pc where
the images will be saved.

Details Description
Configure the deletion and automatic
Delete deletion function of images stored in
Local Storage.
Compress and back-up the images stored
Backup
in Local Storage.

6.4.1 Delete

 Configure the deletion and automatic deletion function of images stored in Local
Storage.

Figure 57. Delete Configuration

AccuVueMED_UM_COM_EN_01 93 / 149
① Storage Delete

 The [Delete] Icon deletes all images stored in the Local Storage.
 Deleted images cannot be restored, so please make sure to perform a backup prior to
deleting images!

② Auto Delete

 Auto Delete
 If checked, all images satisfying the specified conditions are automatically deleted
from the PC Storage.
 Disk Size
 If checked, images in the PC Storage are automatically deleted once the used
disk space exceeds the set limit.
 If remaining storage is less than ‘Disk Size’, overflowed images will be
automatically deleted. (Whole disk volume except ‘Disk Size’ is allocated for
AccuVueMED.)
 Max: maximum limit of disk space set for storage of images in the PC Storage.
 Period
 If checked, images in the PC Storage are continuously deleted automatically
during the set period below.
 ex1) Set to "2", "Month": Delete all images that were stored 2 months earlier as of
today..
 ex2) Set to "1" "Day": Delete all images that were stored 1 day earlier as of today.
 The cycle may be set by one of the followings; Day/Week/Month/Year.
 Only one of the two auto deleting methods, ‘Disk Size’ and ‘Period’, may be selected
at a time.

AccuVueMED_UM_COM_EN_01 94 / 149
6.4.2 Backup

 Compress and back-up the images stored in Local Storage.

Figure 58. Backup Configuration

① Database Backup Configuration

 Display the location of the folder used for Data Backup.


 Edit
 Open the selection window for choosing a folder to be used in backup.
 Compress
 Compress and then store the currently used data in the selected folder.
 Restore
 File selection window opens.
 Restore the selected database file and store it in the system.
 Backup

AccuVueMED_UM_COM_EN_01 95 / 149
 Back-up the currently used database in the selected folder.

② Automatic Backup

 Auto Backup Check


 If checked, automatic backup is performed during the set period explained below.
 Period
 Set the automatic backup period.
 Available units consist of Day / Week / Month.

AccuVueMED_UM_COM_EN_01 96 / 149
6.5 Account

 Configure the account of the AccuVueMED user.

Figure 59. User Account Configuration

 The currently registered user information is available on the list.


 Configure the user ID, Password, and authorization.
 Delete
 Delete the selected user account.
 Add
 Add a new user account.
 Edit
 Edit an existing user account.

AccuVueMED_UM_COM_EN_01 97 / 149
6.6 Block List

 Filter unnecessary RIS codes such as codes related to ultrasound or other devices.

Figure 60. Block List Configuration

 The currently registered Block List information is available on the list.


 Delete
 Delete the selected Block List entry.
 Add
 Add a new entry to the Block List.
 Edit
 Edit the existing Block List entry.

AccuVueMED_UM_COM_EN_01 98 / 149
6.7 Dataset

 Configure the DICOM Header Format.

Figure 61. Dataset Configuration

① DICOM Header Item Configuration

 CR and DR are separately applied.


② Image format

 Configure the Image format information.


③ Study Format

 Series Order
 Set the series order to be used when transmitting the images to PASC
 One series: Combine the images in the same study into one series (DR method)
 Each series: Separate the images in the same study into individual series.

AccuVueMED_UM_COM_EN_01 99 / 149
6.8 Network

 Configure network information such as IP addresses.

Subcategory Description
Network connection is required.
Configure the network information of the PC (or
Local
Work Station) currently operating
AccuVueMED.
Network connection is required.
MWL Configure the network information of the server
storing the Modality Worklist.
Network connection is required.
Storage Configure the network information of the
Storage Server, which stores the image files.
Printer connection is required.
Printer Configure the connection information of the
printer.
Network connection is required.
MPPS Configure the network information of the MPPS
server

AccuVueMED_UM_COM_EN_01 100 / 149


6.8.1 Local

 Configure the network information of the PC (or Work Station) currently operating
AccuVueMED.

Figure 62. Local Configuration Screen

 AE Title
 Enter the name of the local PC (or Work Station) which will be displayed on the
Network.
 IP
 Enter the IPv4 Address of the PC (or Work Station) currently operating
AccuVueMED.
 Port
 Enter the Port number.
 It should be configured in accordance with the linked server.
 All entered information will be automatically saved and applied.

AccuVueMED_UM_COM_EN_01 101 / 149


6.8.2 MWL

 Modality Worklist Server.


 Set the server retrieving the patient lists.

Figure 63. MWL Configuration Screen

① Information of server being accessed

 Manage the information of server being accessed.


 List of AE Title(Access Server Name), IP, and Port information.
 Test
 Verify the connection with the selected server.
 Delete
 Delete the selected server from the list.
 Add
 Add an access server.
 Edit
 Edit the selected server information.

AccuVueMED_UM_COM_EN_01 102 / 149


② Option

 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is unresponsive for the set period
of time.
 Query
 Decide whether you want to perform the refresh automatically or manually.
 Interval
 Refresh is performed automatically every input interval.

③ Query

 Decide which item to use for the condition to load the worklist
 Type
 Modality Query Base : Invokes the Worklist only in terms of duration and modality.
 Patient Query Base : The Worklist is loaded in addition to the items set as Base in
the Period and Modality types.
 Base
 Perform a Patient Query Base with the set items.

④ Modality

 Select the modality type of the imaging equipment.


 E.g. CR, DR
 Add
 Add Modality.
 Delete
 Delete the selected Modality.

⑤ MWL Date type

 Specify the format of the date to be used for the condition in which the Worklist is to
be loaded.

AccuVueMED_UM_COM_EN_01 103 / 149


6.8.3 PACS

 Configure the Storage Server (PACS).

Figure 64. Storage Configuration

① Storage Server

 Manage the information of accessing storage server.


 It consists of AE Title (Access server name), IP, Port and Selection information.
 DICOM images are sent to the PACS server if the selection item of the server is ‘O’.
More than one PACS server can be selected at a time.
 Test
 Verify the connection with the selected server.
 Delete
 Delete the selected server from the list.
 Add

AccuVueMED_UM_COM_EN_01 104 / 149


 Add an access server.
 Edit
 Edit the selected server information.

② Option

 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is unresponsive for the set period
of time.

6.8.4 Printer

Figure 65. Printer Configuration

① Printer Information & Printer Selection for Connection

 Manage the information of the printer to be connected.

AccuVueMED_UM_COM_EN_01 105 / 149


 Select the printer from the list.
 Add
 Add a printer.
 Edit
 Edit the selected printer information.
 Delete
 Delete the selected printer from the list.
 Test
 Verify the connection with the selected printer.

② Option

 Restrict the response time by the Printer.

③ Medium Type

 Select the type of film. (Clear Film / Blue Film)

④ Border

 Set the color of the border line. (Black / White).

⑤ Smoothing

 Apply an ‘Smoothing’ effect. (Medium / Sharp / Smooth)

⑥ Magnification

 Set the Magnification.

⑦ Density

 Adjust the Gray-Level Scale.

AccuVueMED_UM_COM_EN_01 106 / 149


⑧ Printer DPI

 Select the resolution of the printer.

⑨ Overlay information

 Select the additional annotation information added on the film.


 The following pop-up window in [Figure 62] appears when clicking the [Edit] icon.

Figure 66. Printer Overlay Information Edit

 Instructions for use are identical with the overlay configuration of the image.

Refer to 6.3.3 Overlay for more details.

AccuVueMED_UM_COM_EN_01 107 / 149


6.8.5 MPPS

 Modality Performed Procedure Step

Figure 67. MPPS Information Edit

① Information of server being accessed

 Manage the information of server being accessed.


 It consists of AE Title (Access Server Name), IP, and Port information.
 TEST
 Verify the connection with the selected server.
 Delete
 Delete the selected server from the list.
 Add
 Add an access server.
 Edit
 Edit the selected server information.

AccuVueMED_UM_COM_EN_01 108 / 149


② Option

 Station AE Title
 Inner Name of MPPS Server
 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is unresponsive for the set period
of time.

6.9 Detector

 Detector related configurations.


 Run Calibration Tool and Terminal Console programs.

Subcategory Description
Register and edit the model of panel
(detector) being used.
General
Execute detector software, ECali1 (or
Caliview) and Terminal Emulator.
Detailed configuration screen related to
Panel A, registered in ‘General’ tab.
Panel A Detailed configuration items for panel are
created in accordance with the number of
panels registered in ‘General’.

AccuVueMED_UM_COM_EN_01 109 / 149


6.9.1 General

 Register and edit the panel (detector) to be used.


 Execute calibration software, ECali1 (or Caliview) and Terminal Emulator.

Figure 68. General Configuration

① Panel(Detector) Model Registration and Editing

 Register the panel to be connected.


 Add
 Register the detector selected from ‘Model Select’.
 Edit
 Replace the currently registered detector with the detector selected from
the ’Model Select’.
 Delete
 Delete the most recently registered detector.

AccuVueMED_UM_COM_EN_01 110 / 149


② ECali1

 Press [Run] icon to execute the ECali1 (or Caliview) program.

③ Terminal

 [Run] icon executes the Terminal Emulator.


 It only works with FLAATZ Model.

6.9.2 Detailed Configuration by Panel

 Perform detailed configuration for each panel (detector).


 A menu such as ‘Panel A’ and ‘Panel B’ are generated in accordance with the
number of panels registered in ‘General’.

Figure 69. Detector Detailed Configuration Screen

① Receptor

AccuVueMED_UM_COM_EN_01 111 / 149


 Set which Receptor type the detector will utilize.
 Stand, Table and Wireless mode are available.
 Wireless Mode is only available for wireless detectors

② Model

 Model types of the detector.


 Automatically set by the value registered in ‘General’ tab.

③ Serial Number

 Enter the serial number of the Detector.

④ Grid Type

 Grid Type: Select type of grid.


 Line / Inch: Enter the line/inch value of the grid.
 Angle: Enter the angle value of the grid.
 The information about the Grid that has been set in Ecali (Grid sensitivity, Offset, etc)
can be checked.

⑤ Image Mode

 Configure the sensitivity of the image.


 Configure the offset value of the image.
 Configure image mode.

⑥ Transmission Mode

 Select the transmission mode for the acquired images.


 You can select between the transmission mode with high resolution image and fast
transmission mode. .
 This function is only available for EVS 2430.

AccuVueMED_UM_COM_EN_01 112 / 149


6.10 RIS Code

 RIS (Radiology Information System) Code is a collection of projections.


 It regulates contents in areas. For example, “A, B, C regions are to be imaged for RIS
Codes for certain cancers.”
 It allows the rearrangement of sequence of projections.

Figure 70. RIS Code Configuration

 RIS Coode Import from Excel


 Add the RIS Code value from an Excel file.
 Note: Duplicate code values are overwritten with contents of the Excel file. (It
overwrites the existing data).
 Delete
 Delete the selected RIS Code.
 Deletion of information part of the Code, such as the projection, is executed by

AccuVueMED_UM_COM_EN_01 113 / 149


using the [Edit] icon.

 Edit
 Manage the information, such as detailed projection information and imaging
environment, of the RIS Code.
 Refer to 6.10.1 Edit RIS Code Window for more details.

6.10.1 Edit RIS Code Window

Figure 71. RIS Code Edit Window

① RIS Code List

 Manage the code and provide description of RIS Codes.


 Text Box
 Used to view the Code and Description when adding or editing the RIS Code.

AccuVueMED_UM_COM_EN_01 114 / 149


 3 task icons are available. The descriptions are as noted in [Table 12].

Table 12. RIS Code List Management Icon


Icon Description
Edit the code and description of the RIS Code selected from
the list with the information entered in the text box below the
icon.

Edit [Editing Sequence]


1) Select the code to be edited from the list.
2) Enter in new information in the textbox below the icon.
3) Click the [Edit] icon.
Add the RIS Code with the information entered into the textbox
below the icon.

Add [Adding Sequence]


1) Enter new information in the textbox below the icon.
2) Click the [Add] icon.
Delete the RIS Code selected from the list.

[Deleting Sequence]
Delete 1) Select the code to be deleted from the list.
2) Click the [Delete] icon.
Extract and add the RIS code from the patient list retrieved
from the MWL server.

RIS Code and description is added but position information is


not included

AccuVueMED_UM_COM_EN_01 115 / 149


② Editing of projections included in the RIS Code

 Manage the projections to be included in the selected RIS Code.


 Descriptions concerning the task icons are as noted in [Table 13].

Table 13. RIS Code Projection Management Icon

Icon Description
Both icons perform identical tasks.
, Add the projections relevant to the selected
Add Projection/Position in the RIS Code.

Delete the Projection category from the RIS Code.


Delete

Move the selected Projection category up by one


row.
Move up

Move the selected Projection category down by one


row.
Move down

③ Imaging Environment Configuration

 Enter the automatically configured environment value when imaging of the pertinent
RIS Code is performed.
 HR / HT
 Select the image transfer mode according to the imaging body part.(EVS-2430 Only)
 HR : High Resolution, HT : High Transfer
 Patient Size
 Select the patient size.
 4 levels of selections are available.
 AEC
 Set the AEC.
 Grid
 Select the Grid Type being used. (None / Fixed / Moving).
 Focal Spot

AccuVueMED_UM_COM_EN_01 116 / 149


 Set the focus. (Large / Small)
 Density
 Set the density.
 SID
 Set the distance between the Detector and X-ray Tube.
 kVp, mA, mAs(mSec)
 Set the Generator condition.
 Parameter
 Locate the parameter file of the image processing which will be applied after
talking image.
 Rotation
 Set the rotation rate of the image.
 Flip H, Flip V
 Select whether to flip the image horizontally or vertically.
 Shutter
 Select the ROI Size.
 Marker
 Set and manage the marker, which will be automatically inserted in the image.
 Descriptions regarding the Marker Icon are as noted in [Table 14].
Table 14. Marker Icon

Icon Description
Add a new Marker.
Refer to 6.10.2 Add Marker Window for more
Add details.

Delete the selected marker.


Delete

Move the selected Marker up.


Move up

Move the selected Marker down.


Move down

AccuVueMED_UM_COM_EN_01 117 / 149


6.10.2 Add Marker Window

Figure 72. Add Marker Window

 Location
 Select the location for the marker to appear on the image
 Text
 Select the type of Marker
 In addition to the texts provided by default, random texts can be used as a marker
 User registered markers can be selected from the list
 The Marker list window can be edited by using the [Add] Icon and [Delete] Icon
 To change overall marker size, go to ‘Projection’ tab – “Marker font size” menu.

AccuVueMED_UM_COM_EN_01 118 / 149


6.11 Projection Editor

 Manage the Projection type

Figure 73. Projection Editor Configuration

 Marker Size
 Change marker size.
 Rotation
 Set rotation selected receptor's all projection & position.
 Flip V and Flip H are first applied and then Rotation is applied.
 Delete
 Delete the selected Projection or Position
 Recent selections which will be deleted by clicking the [Delete] icon are
highlighted in yellow
 Edit
 Edit the Projection and Position after opening the ‘Project Editor Window’.
 Refer to 6.11.1 Projection Editor Window for more details.

AccuVueMED_UM_COM_EN_01 119 / 149


6.11.1 Projection Editor Window

Figure 74. Projection Editor Window

① Anatomy

 It must be selected first.


 Projection and position will not appear unless an anatomical region is selected
from the Anatomy
 Select the projection
 If the Receptor Type is different, even if the anatomical regions are the same, it will
be saved as a different setting
 Make sure to set the anatomical region, as well as the Receptor type.

AccuVueMED_UM_COM_EN_01 120 / 149


② Projection

Figure 75. Projection Configuration

 Manage the Projection list


 Refer to [Table 15] for instructions of each icon

AccuVueMED_UM_COM_EN_01 121 / 149


Table 15. Projection/Position List Management Icon

Icon Description

Edit the name of the selected category from the list with
the entry in the left textbox

[Edit Sequence]
1) Select the category to be edited from the list
Edit
2) Enter the new information in the textbox on the left of
the icon
3) Click the [Edit] icon
Add the category with the information entered into the
textbox on the left of the icon

[Add Sequence]
Add 1) Enter the new information in the textbox on the left of
the icon
2) Click the [Add] icon
Delete the selected category from the list

[Delete Sequence]
Delete 1) Select the category to be deleted from the list
2) Click the [Delete] icon

Move the selected projection category up one row in the


list
Move up

Move the selected projection category down one row in


the list
Move down

AccuVueMED_UM_COM_EN_01 122 / 149


③ Position

Figure 76. Position Configuration

 Manage the Projection list


 Refer to [Table 15] for instructions concerning each icon

④ Imaging Environment

 Set the appropriate imaging environment for the selected projection


 Detailed information concerning the Imaging Environment Configuration is identical to
the Imaging Environment Configuration of the ‘RIS Code Edit Window’.
 Refer to ‘③Imaging Environment Configuration’ of 6.10.1. Edit RIS Code Window.

AccuVueMED_UM_COM_EN_01 123 / 149


6.12 Recycle Bin

 Configure deleted images.


 Recycle Bin setting is available if “Use Recycle Bin” is checked in “Delete” option of
“Image” tab.

Figure 77. Recycle Bin Setting

 If an image is deleted while the recycle bin option is activated, you can see the
information of the deleted image through “Recycle Bin” tab.

① Deleted image information


 Show the list of deleted images
 Search an image by date using Search button.

AccuVueMED_UM_COM_EN_01 124 / 149


 Select all the images stored in recycle bin at once using “Select all” button.
 All selected items are unselected when clicking “Deselect all” button.

② Recycle Bin Function


 Delete
 Delete the selected image permanently.
 Restore
 Restore the selected file.

AccuVueMED_UM_COM_EN_01 125 / 149


Appendix A. Glossary

Terms Description

Picture Archiving and Communication System.


PACS System for the storage, interpreting and access of
medical imaging information
Digital Imaging and Communication in Medicine.
DICOM Standards and regulations regarding medical
digital imaging and communications.
DICOM Directory.
DICOMDIR DICOM directory information file is stored in the
root folder of the media (CD/DVD).
Hospital Information System.
HIS Information of registration/administrative system,
including OCS, PACS, etc.

OCS Order Communication System

Radiology Information System.


RIS
Operated as part of HIS or independently
Modality Worklist.
MWL DICOM standards for sharing scheduled
examination information
Computer Unified Device Architecture.
CUDA High speed parallel processing architecture
utilizing a GPU developed by NVIDIA
GPU Graphic Processing Unit.
Graphical User Interface.
GUI Computer interface for the user, developed by
graphic elements
Detector Flat Panel Digital X-ray Detector.
Program which converts source codes in high level
Compiler
language into specific machine codes

AccuVueMED_UM_COM_EN_01 126 / 149


Process where the source code is being converted
Build
for computer operation
Application Programming Interface.
API Interface developed for use of specific functions in
the application program
Program run for installation, maintenance and
Installer
removal of a specific application program.
Process authenticating the user for permission to
Login
access the system
Coding
Style guideline to create a source code
Convention
Code Process where developers inspect and verify the
Review created/edited source code
Code Tested number of code components/Total number
Coverage of code components * 100
Process of discovering potential defects of the
Static Code
program without operating it by analyzing the
Analysis
source code
Cyclomatic Digitized level of complexity of the program’s
Complexity source code
Continuous Integration.
Automated integration process of the source code,
CI
and the process of improvement and receiving
feedback through periodic build, test analysis
Encryption Encrypting the data
Protection Protection preventing program hacking through
(Anti-Crack) Reverse Engineering
SCP Service Contents Provider
Text and various shapes marked on the completed
Annotation
image
Lookup Table.
LUT
Table of previously calculated values.

AccuVueMED_UM_COM_EN_01 127 / 149


Region of Interest.
ROI
Actual region necessary in a completed image.
Exception Task calibrating the quality of the detector image.
Generic term of data files used for the calibration
Calibration
of detector image quality.
Lookup Table.
Map File
Table of previously calculated values.
Pixel Map Data file used to calibrate bad pixels in detectors.
Data file used to calibrate the properties of the
Gain Map
detector subsequent to installation environment.
Data file used to calibrate the properties of the
Panel Map
detector panel itself.

AccuVueMED_UM_COM_EN_01 128 / 149


Appendix B. Update
If currently using version has bugs, please contact CS team so that CS team send you an
update (patch) installer.

If you receive the update installer file, please run the provided setup file.

 Please back up original AccuVueMED folder (ex: C:\EConsole1) in order to prevent a


fatal error.

If the setup file runs the following screen will appear..


Click [Next] to start the installation.

AccuVueMED_UM_COM_EN_01 129 / 149


Select license protection type you purchased.

 Hardware License Protection (Dongle Key)


 Provide special USB
 You can run AccuVueMED only when the USB connected.
 Software License Protection
 Provide the license on the special PC.

AccuVueMED_UM_COM_EN_01 130 / 149


Do not change installation folder and click [Next].
It will update the program automatically. When the installation is finished, please run the
AccuVueMED and check the version.

AccuVueMED_UM_COM_EN_01 131 / 149


Appendix C. Stitching
Stitching provides the ability to automatically align images taken from multiple sites and
one of the features that combine Images.

 Support up to 4 mages.
 Set SID as 180cm.
 When performing the projection, please minimize the
patient's movements.
Caution
 When performing the projection, please make sure that
the overlapping area is at least 10cm.
 Please note there may be errors in automatic
alignment according to projection environment.

In order to perform the stitching function, you should select the projection in following two
ways.

 WHOLE SPINE
 LONG BONE

AccuVueMED_UM_COM_EN_01 132 / 149


Same projection – After acquiring the images to be stitched, press the toolbar icon.
A ‘Stitching Window’ will pop-up. Then images that are used for stitching will be
automatically sorted.

Stitching screen is split into three areas.

 Thumbnail
 Display an image that can be used for stitching.
 Image Viewer
 Display aligned the images automatically.
 Toolbar
 A collection of icons and buttons that let you perform various commands.

Common course of stitching are as follows.


 When automatically aligned images are in right position.

 Press the button to apply stitching.


 When the automatically aligned images are not in right position.
 Place images to be stitched in image viewer and align the images manually.

AccuVueMED_UM_COM_EN_01 133 / 149


 Press the button in the Toolbar and click the overlapped part of the
image to be stitched.
 Press the button to apply stitching.

 When you want to align the images in the image viewer automatically.

 Press the button to align the images automatically.

When you finish all the stitching works, press the [OK] button to exit.
Descriptions of the icons in the toolbar are as follows.

Icon Description

Stitching direction.

Move the image.

Change the W/L.

Zoom In

Zoom Out

Perform zoom in/out of image according to the


height of the Viewer.
Perform zoom in/out of image according to the
width of the Viewer.

Left and right Flip

Up and down Flip

Change the image sequence (top)

Change the image sequence (bottom)

AccuVueMED_UM_COM_EN_01 134 / 149


Image rotation (counter clock-wise)

Image rotation (clock-wise)

Enter stitching point

Clear stitching point

Align images in image viewer.

Separate pasted the image.

When entering the stitching point, two images


are synthesized.
When no stitching point is input, all the aligned
images are synthesized in the image viewer.
Additional image processing options Point:
When you enter the stitching point, revise Hand
tremors in touch environments. (Default is OFF)
Brightness: Revise the brightness between the
images. (Default is ON)

Move the selected image to the pixel unit.

Store all the stitching operation and then end


the procedure.

Clear the stitching operation, and shutdown.

AccuVueMED_UM_COM_EN_01 135 / 149


Appendix D. Portable function
* The CR Mode of the EVS2430W is available through this portable function of
AccuVueMED. Some of wireless detectors offer a function to save a x-ray image.
If the user shot a x-ray without using the software, the image will be saved in the detector.
This saved image control function is called "Portable function".

Portable function summary

AccuVueMED_UM_COM_EN_01 136 / 149


AccuVueMED Vet's portable has two following functions.
 Download the image saved in detector
 Register the exam order to detector

1) Download the image saved in detector.


Proceed in the following order
① Select an exam order and go to acquisition.

② Click icon in the ToolBar


 If it is not in the toolbar, click the [Edit]' and add it.
③ Save portable image pop-up comes up.
 Select an image in the Detector.
 Click [OK].

Save Portable Image Window

Save portable image

① Select an image saved detector.

AccuVueMED_UM_COM_EN_01 137 / 149


② Show the file names of the saved images of the selected detector
③ The preview image of the selected image.
④ Function button and UI.
 Refresh
 Refresh a image list
 Delete
 Delete the selected image in detector.
 Delete all
 Delete all the images in the selected detector.
 Used(%)
 Used storage of the selected detector.
 OK
 Get the selected image and show it to AccuVueMED Vet's image viewer.
 Cancel
 Close the 'Save Portable Image Window’.

2) Register the exam order to detector


It is the function that saves exam orders to the detector and shots an image without PC
depending on the given exam list.

Save exam order function

① Click button.
② The 'Save Image List Window’ comes up.
 Select a detector.
 Select List on the right side and click '<' button.
 The list on the left side is saved to the detector when clicking the [Save] button.

AccuVueMED_UM_COM_EN_01 138 / 149


Save Image List

Save image list

① Select a detector.
② The list will be saved in detector.
③ Show Current work list.
④ Function buttons.
 < Button
 Add a selected list.
 Delete
 Delete selected list.
 Delete all
 Delete all work list.
 UP/Down
 Change work list's order.
 Refresh
 Refresh work list.
 Set portable
 Change the detector's image acquisition mode to portable mode.
 Caution: If it is set to portable mode, AccuVueMED vet and detector's
connection will be disconnected.

AccuVueMED_UM_COM_EN_01 139 / 149


 If you want to connect AccuVueMED Vet and detector, press [AP] button on
the detector's side.
 Used (%)
 Used storage of the selected detector.
 Save
 Save worklist on the left side to the detector.
 Cancel
 Close the 'Save Image List Window’.

AccuVueMED_UM_COM_EN_01 140 / 149


Appendix E. How to use rotation tools

1) Image rotate
 Image rotate tool operation procedure.

① Click tool for activate rotate mode.


② Draw angle to rotate. Rotate direction will same as finish direction.

Prepare rotation

Apply rotation

AccuVueMED_UM_COM_EN_01 141 / 149


③ Click tool again to apply rotation and save image.

Image rotation applied

2) Free area image cropping and rotate

① Click tool for activate free area crop and rotate mode.
Draw rectangle to crop and rotate.

Activate tool and draw rectangle to crop

AccuVueMED_UM_COM_EN_01 142 / 149


② Adjust rectangle area and angle.

Adjust rectangle area.

③ Click tool again to apply

Cropping and rotation applied

AccuVueMED_UM_COM_EN_01 143 / 149


Appendix F. Gain Calibration
Please perform gain calibration every 6 months in order to avoid any abnormal effects.

Preparation

- Aging for 20 minutes before starting calibration


- Fully open Collimator to cover X-ray on the whole detector area.
- Put an Acryl Phantom (4cm) on Bucky.
- Set Grid type as “None” in ECali1 configuration. (When Grid Line Pattern appears, set
Grid Type depending on the product model)

Calibration Procedure

* Check the radiation field and clear Acryl Phantom as well as Bucky before calibration.
* If the Mean values of every image have more than 300Gy difference, you have to re-
take images.

1. Run Ecali1

2. Select the detector to perform the Gain Calibration from the Detector Menu. (Tool bar
→ Detector)

Detector Selection

3. Select Gain Map Calibration from the Tool bar or select the shortcut icon.

AccuVueMED_UM_COM_EN_01 144 / 149


Starting Gain Calibration

4. When a notification message appears, select [OK]

Gain Calibration Start Notification

5. ECali1 alerts whether the radiation dose is appropriate or whether it should be


automatically calculated. Proceed by selecting [OK].

* Set OP console manually (approx. 28kVp 80mAs)


* Mean value should be 2,200 ~ 2,500Gy.

X-ray Radiation Dose Check Activation

AccuVueMED_UM_COM_EN_01 145 / 149


6. A main screen will appear. Proceed with the X-ray projection at this point in order to
acquire an image.

Projection Standby Main Screen

7. The program automatically determines the appropriateness of the X-ray radiation dose
when the image is acquired.

X-ray Radiation Dose Verification Notification

8. If provided with a notification of low radiation dose, please select [OK] then increase
the X-ray radiation dose and re-project.

Notification for Low X-ray Radiation Dose

AccuVueMED_UM_COM_EN_01 146 / 149


9. A notification will also appear if the X-ray radiation dose is high. Please select [OK]
then reduce the X-ray radiation dose and re-project.

10. If the X-ray radiation dose is appropriate, please select [OK] and proceed with the
projections

Notification for Appropriate X-ray Radiation Dose

11. A notification informing the requirement of 7 images will appear. The required number
of images may be set in Configuration. Select [OK] and proceed with the projections of 7
images.

.
Notification Informing 7 Images Requirement

Starting the Gain Calibration Projection

AccuVueMED_UM_COM_EN_01 147 / 149


Standby post Projection of 1 Image

12. Wait until the next designated projection is ready after the initial projection.

Projection Standby Timer

13. The next projection will take place after the projection standby timer (60 seconds)
disappears. The projection standby time may be set in Configuration.

14. The Gain Calibration results are automatically saved as Gain Map (*.GMP) when all
required images are projected and the existing files are backed-up.

Notification for Gain Calibration Completion

AccuVueMED_UM_COM_EN_01 148 / 149


15. The existing GMP files are backed up in the [ECali1 Installation Folder]\MAP folder.
The file name is as noted in [Figure 89]

Example of back-up file

AccuVueMED_UM_COM_EN_01 149 / 149