SDCS Com 81
SDCS Com 81
DC drives
Upgrade Kits DCV700/DCS500/DCS600
DCS800
© ABB Group
May 13, 2013 | Slide 1
DCS800-R Upgrade Kits
Upgrade solutions for DCS500 / DCS800 drives
© ABB Group
May 13, 2013 | Slide 2
DCS800-R Upgrade Kits
Availability overview for DCS500/DCV700
DCS800-R Upgrade kits are only available for yellow highlighted converter types
© ABB Group
May 13, 2013 | Slide 3
DCS800-R Upgrade Kits
Availability overview for DCS500B/DCS600
© ABB Group
DCS800-R Upgrade kits are only available for yellow highlighted converter types
May 13, 2013 | Slide 4
DCS800-R Upgrade Kits
Requirements and Design conditions for Upgrades
© ABB Group
May 13, 2013 | Slide 5
DCS800-R Upgrade Kits
Supported and not supported parts
Supported parts Not supported parts
I/O board SDCS-IOB-2x all old field exciters for DCS 500, DCS 500B
and DCS 600,
I/O board SDCS-IOB-3,
DCS-IOE-1
control panel CDP 312 xx via SDCS-COM-
81 or SDCS-COM-82 and control panels CDP 310 and CDP 311
Nxxx fieldbus adapter used with DCS 500B Nxxx fieldbus adapter used with DCS 500
or DCS 600 via SDCS-COM-82
APC1 used for DCV 700
Reuse of APC2 requires modifications in the
control logic and additional hardware
All old tools like DDCTool, CMTTool,
DriveWindow 1.x and DriveWindow 2.1
© ABB Group
May 13, 2013 | Slide 6
DCS800-R Upgrade Kits
Conditions caused by the application
In case of an additional application three scenarios are possible
Application program located in the APC1 or APC2 of a DCV 700.
APC1: No interface available
APC2: Optical connection board YPQ112 is to add between APC2 and SDCS-COM-
81 and control logic is to modify
The application program is as function blocks in the DCS 500 or DCS 500B. DriveAP
Programmimg or CoDeSys Programming
The application program is located in the AMC board of a DCS 600 see APPLIC NAME
(4.03) CoDeSys Programming
Master-follower configurations
Master-follower via SDCS-COM-8 should be used for upgrading a DCS 600. The fiber
optic cable can be reused.
Master-follower via DCSLink should be used for upgrading a DCS 500 or DCS 500B.
Hard-Parallel configuration
Additional engineering is needed. Please contact your local ABB .
© ABB Group
May 13, 2013 | Slide 7
DCS800-R Upgrade Kits
Upgrade size A5 to D5
Article Codes
DCS800-R00-9305
DCS800-R00-9306 (with field exciter)
Included parts
SDCS-POW-4
FEX-425-Int (only DCS800-R00-9306)
electronic tray
SDCS-CON-4 with SDCS-DSL-4
covers
DCS800 Control Panel
SDCS-PIN-51
all boards are coated
Affected modules:
Converter type DCS 500B Converter type DCS 600
DCS50xB0903-y1 DCS60x-0903-y1
DCS50xB1203-y1 DCS60x-1203-y1
DCS50xB1503-y1 DCS60x-1503-y1
DCS50xB2003-y1 DCS60x-2003-y1
© ABB Group
May 13, 2013 | Slide 8
DCS800-R Upgrade Kits
Upgrade size A6/A7 to D6/D7
Article Code
DCS800-R00-9405
Included parts
SDCS-POW-4
electronic tray
SDCS-CON-4 with SDCS-DSL-4
SDCS-PIN-51
covers
DCS800 Control Panel
all boards are coated
Affected modules:
Converter type DCS 500B Converter type DCS 600
DCS50xB1903-y1 DCS60x-1903-y1
DCS50xB2053-y1 DCS60x-2053-y1
DCS50xB2503-y1 DCS60x-2503-y1
DCS50xB3003-y1 DCS60x-3003-y1
DCS50xB2053-y1 DCS60x-2053-y1
DCS50xB2603-y1 DCS60x-2603-y1
DCS50xB3203-y1 DCS60x-3203-y1
DCS50xB3303-y1 DCS60x-3303-y1
DCS50xB4003-y1 DCS60x-4003-y1
© ABB Group
DCS50xB4803-y1 DCS60x-4803-y1
May 13, 2013 | Slide 9 DCS50xB5203-y1 DCS50x-5203-y1
DCS800-R Upgrade Kits
Upgrade size C2b to D5
Article Code
DCS800-R00-9005
Included parts
SDCS-POW-4
electronic tray
SDCS-CON-4 with SDCS-DSL-4
covers
DCS800 Control Panel
all boards are coated
Affected modules:
Converter type DCS 500B Converter type DCS 600
DCS50x-0680-y1 DCS60x-0680-y1
DCS50x-0820-y1 DCS60x-0820-y1
DCS50x-1000-y1 DCS60x-1000-y1
© ABB Group
May 13, 2013 | Slide 10
DCS800-R Upgrade Kits
Upgrade size C3 to D6
Article Code
DCS800-R00-9205
Included parts
SDCS-POW-4
electronic tray
SDCS-CON-4 with SDCS-DSL-4
SDCS-PIN-51
covers
DCS800 Control Panel
all boards are coated
Affected modules:
Converter type DCS 500B Converter type DCS 600
DCS50xB0900-y1 DCS60x-0900-y1
DCS50xB1200-y1 DCS60x-1200-y1
DCS50xB1500-y1 DCS60x-1500-y1
DCS50xB2000-y1 DCS60x-2000-y1
© ABB Group
May 13, 2013 | Slide 11
DCS800-R Upgrade Kits
Upgrade size C4 to D7
Article Code
DCS800-R00-9105
Included parts
SDCS-POW-4
electronic tray
SDCS-CON-4 with SDCS-DSL-4
SDCS-PIN-51
covers
DCS800 Control Panel
all boards are coated
Affected modules:
Converter type DCS 500B Converter type DCS 600
DCS50xB2050-y1 DCS60x-2050-y1
DCS50xB2500-y1 DCS60x-2500-y1
DCS50xB2650-y1 DCS60x-2650-y1
DCS50xB3200-y1 DCS60x-3200-y1
DCS50xB3300-y1 DCS60x-3300-y1
DCS50xB4000-y1 DCS60x-4000-y1
DCS50xB4750-y1 DCS60x-4750-y1
DCS50xB5150-y1 DCS50x-5150-y1
© ABB Group
May 13, 2013 | Slide 12
DCS800-R Upgrade Kits
Overview Parts Upgrade Kit
© ABB Group
May 13, 2013 | Slide 13
DCS800-R Upgrade Kits
DCV700 System Structure
For Master-Follower
communication DCS-Link via
DCS-DSL-4 or DDCS via
SDCS-COM-81 are to use
© ABB Group
May 13, 2013 | Slide 14
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (1/3)
Extension of APC2 controller with a DDCS interface adapter.
YPQ112B
DDCS
Interface
Fiber
optic
link
Not more in
use. Can be
SDCS-COM-81 removed.
SDCS-DSL-4
SDCS-CON-4
Please note:
Installation of the YPQ112B interface adapter requires small modifications in the APC control program.
Availability of the right software tools and programming skills for APC controller are to ensure.
© ABB Group
May 13, 2013 | Slide 15
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (2/3)
Removal of APC2 and direct connection to the overriding system via AF100 (MB90)
= Advant Fieldbus (AF100)
CI810B
Interface
DDCS / Advant
Fieldbus TB810
AF100 communication
interface kit NAFA-01
consisting of:
CI810 + TC505 +
TB810/TB811 Fiber
optic
link
Not more in
SDCS-COM-81 SDCS-DSL-4 use. Can be
removed.
SDCS-CON-4
Please note:
Installation of the CI810B communication interface requires small modifications in the overriding control
system e.g. AC450. Furthermore the removal of the APC controller requires adaption of the existing APC
software program either into the overriding system or into the drive via DriveAP or CoDeSys. Availability of
the right software tools and programming skills are to ensure.
© ABB Group
May 13, 2013 | Slide 16
DCS800-R Upgrade Kits
How to connect existing control system to SDCS-CON-4 (3/3)
Removal of APC2 and direct connection to the overriding system via MFB (MasterFieldbus)
Not more in
SDCS-COM-81 SDCS-DSL-4 use. Can be
removed.
SDCS-CON-4
Please note:
Installation of the PE1354B fieldbus converter requires small modifications in the overriding control system
e.g. MP200. Furthermore the removal of the APC controller requires adaption of the existing APC software
program either into the overriding system or into the drive via DriveAP or CoDeSys. Availability of the right
software tools and programming skills are to ensure.
© ABB Group
May 13, 2013 | Slide 17
DCS800-R Upgrade Kits
Upgrade Kits - Additional Information
Manual with detailed information
For further information regarding hardware, assembling and commissioning see Manual
3ADW00256R0101
Parameter settings
After upgrading parameters have to be adjusted due to different parameter groups in
DCS500/DCS600 and DCS800.
For parameter comparison see document 3ADW000405R0201
Sales Chanel
Product Sales and PartsOnline
© ABB Group
May 13, 2013 | Slide 18