0% found this document useful (0 votes)
33 views13 pages

ATV630C22N4

This 3 sentence summary provides the high level information about the ATV630C22N4 variable speed drive product: The ATV630C22N4 is a 380-480V IP00 variable speed drive with a power rating of 220kW/350HP that can control asynchronous and synchronous motors and has communication capabilities including Modbus TCP, Ethernet, and additional optional communication modules.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views13 pages

ATV630C22N4

This 3 sentence summary provides the high level information about the ATV630C22N4 variable speed drive product: The ATV630C22N4 is a 380-480V IP00 variable speed drive with a power rating of 220kW/350HP that can control asynchronous and synchronous motors and has communication capabilities including Modbus TCP, Ethernet, and additional optional communication modules.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Jan 14, 2020

Characteristics
Product data sheet

380...480V - IP00
ATV630C22N4

1
variable speed drive ATV630 - 220kW/350HP -

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Product availability: Non-Stock - Not normally stocked in distribution facility

Main
Range of product Altivar Process ATV600
Product or component Variable speed drive
type
Product specific applica- Process and utilities
tion
Device short name ATV630
Variant Standard version
Product destination Synchronous motors
Asynchronous motors
Mounting mode Wall mount
EMC filter Integrated 164.04 ft (50 m) EN/IEC 61800-3 category
C3
IP degree of protection IP00IEC 61800-5-1
IP00IEC 60529
IP21 with kit VW3A9112)IEC 61800-5-1
IP21 with kit VW3A9112)IEC 60529
Type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
Phase 3 phase
[Us] rated supply volt- 380...480 V - 15...10 %
age
Motor power kW 160 KW heavy duty)
220 kW normal duty)
Maximum Horse Power 350 Hp normal duty
Rating 250 hp heavy duty
Line current 397 A 380 V normal duty)
324 A 480 V normal duty)
296 A 380 V heavy duty)
246 A 480 V heavy duty)
Prospective line Isc 50 kA
Apparent power 247 KVA 480 V normal duty)
187 kVA 480 V heavy duty)
Continuous output cur- 302 A 2.5 kHz heavy duty
rent 427 A 2.5 kHz normal duty
Maximum transient cur- 453 A 60 s heavy duty)
rent 470 A 60 s normal duty)
Asynchronous motor Constant torque standard
control profile Variable torque standard
Optimized torque mode
Synchronous motor Permanent magnet motor
control profile Synchronous reluctance motor
Output frequency 0.0001…0.5 kHz
Speed drive output fre- 0.1…599 Hz
quency
Nominal switching fre- 2.5 kHz
quency
Switching frequency 2.5...8 kHz with derating factor
2...8 kHz adjustable
Safety function STO (safe torque off) SIL 3
Discrete input logic 16 preset speeds

2
Communication port Modbus TCP
protocol Ethernet
Modbus serial
Option card Slot A communication module, Profibus DP V1
Slot A communication module, Profinet
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/Ether-
Net/IP
Slot A communication module, CANopen daisy
chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw ter-
minals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A: communication module, Ethernet IP/Modbus
TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink

Complementary
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Motor slip compensation Adjustable
Automatic whatever the load
Not available in permanent magnet motor law
Can be suppressed
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Braking to standstill By DC injection
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Frequency resolution Display unit 0.1 Hz
Analog input 0.012/50 Hz
Electrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 2 x 150 mm² 2 x 350 kcmil
Motor screw terminal 2 x 150 mm² 2 x 350 kcmil
Connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Physical interface 2-wire RS 485 Modbus serial
Transmission frame RTU Modbus serial
Transmission rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Method of access Slave Modbus TCP
Supply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and
short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %,
<10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload
and short-circuit protection

3
Local signalling Local diagnostic 3 LEDs
Embedded communication status 3 LEDs dual colour)
Communication module status 4 LEDs dual colour)
Presence of voltage 1 LED red)
Width 17.32 in (440 mm)
Height 47.05 in (1195 mm)
Depth 14.96 in (380 mm)
Product weight 379.20 lb(US) (172 kg)
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Discrete input number 8
Discrete input type DI1...DI6 programmable, 24 V DC <= 30 V)3.5 kOhm
DI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Input compatibility DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Discrete input logic Positive logic (source) DI1...DI6), < 5 V, > 11 V
Negative logic (sink) DI1...DI6), > 16 V, < 10 V
Positive logic (source) DI5, DI6), < 0.6 V, > 2.5 V
Positive logic (source) STOA, STOB), < 5 V, > 11 V
Analogue output number 2
Analogue output type Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AO1, AO2 0...20 mA 10 bits
Sampling duration 2 Ms +/- 0.5 ms DI1...DI4) - discrete input
5 Ms +/- 1 ms DI5, DI6) - discrete input
5 Ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Relay output number 3
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Refresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3 5 mA 24 V DC
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Isolation Between power and control terminals
Variable speed drive application selection Building - HVAC Compressor centrifugal
Food and beverage processing Other application
Mining mineral and metal Fan
Mining mineral and metal Pump
Oil and gas Fan
Water and waste water Other application
Building - HVAC Screw compressor
Food and beverage processing Pump
Food and beverage processing Fan
Food and beverage processing Atomization
Oil and gas Electro submersible pump (ESP)
Oil and gas Water injection pump
Oil and gas Jet fuel pump
Oil and gas Compressor for refinery
Water and waste water Centrifuge pump
Water and waste water Positive displacement pump
Water and waste water Electro submersible pump (ESP)
Water and waste water Screw pump
Water and waste water Lobe compressor
Water and waste water Screw compressor
Water and waste water Compressor centrifugal
Water and waste water Fan
Water and waste water Conveyor
Water and waste water Mixer
Motor power range AC-3 110…220 KW 380…440 V 3 phase
110…220 kW 480…500 V 3 phase

4
Environment
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Noise level 66 dB 86/188/EEC
Power dissipation in W Forced convection 5030 W
Natural convection 451 W 380 V 2.5 kHz
Volume of cooling air 227192.03 Gal/hr(US) (860 m3/h)
Operating position Vertical +/- 10 degree
Maximum THDI <48 % full load IEC 61000-3-12
Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC
61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Pollution degree 2 EN/IEC 61800-5-1
Vibration resistance 1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
1 gn 13…200 Hz)IEC 60068-2-6
Shock resistance 15 gn 11 ms IEC 60068-2-27
Relative humidity 5…95 % without condensation IEC 60068-2-3
Ambient air temperature for operation 14…104 °F (-10…40 °C) without)
104…140 °F (40…60 °C) with derating factor)
Ambient air temperature for storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without
3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Environmental characteristic Chemical pollution resistance class 3C2 EN/IEC 60721-3-3
Dust pollution resistance class 3S2 EN/IEC 60721-3-3
Standards UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Product certifications TÜV
CSA
UL
REACH
Marking CE

Ordering and shipping details


Category 22207 - ATV630 FRAMES 5 & 6
Discount Schedule CP4E
GTIN 00785901527923
Package weight(Lbs) 182.80 kg (403 lb(US))
Returnability Yes
Country of origin CN

Offer Sustainability
Sustainable offer status Green Premium product
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead
compounds which is known to the State of California to cause Carcinogen & Re-
productive harm. For more information go to www.p65warnings.ca.gov
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration

5
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins.

6
Product data sheet ATV630C22N4
Dimensions Drawings

Dimensions

Rear, Right and Front Views

7
Product data sheet ATV630C22N4
Mounting and Clearance

Clearances

X1 X2 X3

≥ 200 mm (7.87 in.) ≥ 150 mm (5.91 in.) ≥ 10 mm (0.39 in.)

Mounting Types

Mounting Type A: Individual IP21

a≥ 0

8
Mounting Type B: Side by Side IP20

Mounting Type C: Individual IP20

a≥ 0

9
Product data sheet ATV630C22N4
Connections and Schema

Three-Phase Power Supply with Upstream Breaking via Line Contactor

Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1

(1) Line choke if used


(2) Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
KM1 :Line Contactor
Q2, Circuit breakers
Q3 :
S1, Pushbuttons
S2 :
T1 : Transformer for control part

Three-Phase Power Supply with Downstream Breaking via Contactor

Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1

(1) Line choke if used


(2) Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
KM1 :Contactor

10
Control Block Wiring Diagram

(1) Safe Torque Off


(2) Analog Output
(3) Digital Input
(4) Reference potentiometer
(5) Analog Input
R1A, Fault relay
R1B,
R1C :
R2A, Sequence relay
R2C :
R3A, Sequence relay
R3C :

Sensor Connection
It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.

Sink / Source Switch Configuration

The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.
● Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
● Set the switch to Ext if using PLC outputs with NPN transistors.

11
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs

Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs

Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs

Switch Set to EXT Position Using an External Power Supply for the DIs

12
Product data sheet ATV630C22N4
Performance Curves

Derating Curves

40 °C (104 °F)
50 °C (113 °F)
60 °C (140 °F)
In : Nominal Drive Current
SF : Switching Frequency

13

You might also like