SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 33/N
Control box
3.2.1 Daily inspection items and standards - - - - - - - - - - - - - - - - - - - - - - - - - - - 34
3.2.2 Control box MCCB --------------------------------------- 38
3.2.3 Determine voltage and fuse - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 38
3.2.4 Insulation measuring and earthing- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 39
3.2.5 Electronic contactor --------------------------------------- 40
3.2.6 PCB base board --------------------------------------- 41
1) Main PCB --------------------------------------- 41
2) Synchromotor PG card - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 46
3) SM.02/1 PCB(TOC Controller Board) - - - - - - - - - - - - - - - - - - - - - - - - - - - - 47
4) SM.02/G PCB --------------------------------------- 49
5) SM-03 PCB(Car Call Board) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 50
6) SM.04V 12/A(Call & Display Control Board) - - - - - - - - - - - - - - - - - - - - - - 51
7) SM.04V 12/A --------------------------------------- 52
8) BST Door Controller - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 53
3.2.7 Transformer --------------------------------------- 54
3.2.8 Regeneration resistance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 54
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 34/N
Notice
When check the control box, cut off the power supply; after
performing Lock Out /Tag Out, conduct work.
Please determine whether plastic cap is covered on the terminal.
If cap is not covered on its top, please make cap cover the top.
If power supply is 200V or 400V, please affix marking label to
make others take care.
If PCB is applied, it should be avoided that PCB is scratched by
protruded pin at back.
If INV elevator type is applied, after cutting off power supply,
smoothing condenser is still in charging state; therefore, please
determine whether DC voltage on capacitor two ends conduct
working after discharging completely.
Ambient temperature:
Naked eyes, lower than 40℃,
Ambient temperature, moisture, vibration,
Operating thermometer, accord with moisture 1 month
dust, corrosive gas, oil, dust, dribbles etc.
environment hygrometer etc. environment
requirements
Whether danger exists around the assembly Naked eyes No dangerous item 1 month
LCD
Whether LCD indicating is normal Naked eyes Indicating is normal 1 month
indicating
Connector Bolts relaxation is not allowed. Naked eyes, No abnormal condition
1 month
terminal Connector relaxation is not allowed. screwdriver Assemble is stable
Bolts and tail Determine whether protective layer cracks Naked eyes No abnormal condition 1 month
cord or discolors
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 35/N
(1) Num of electric wire connected on a terminal is 2 strands, and num of both sides is less
than 4 strands. And it is not allowed that the current is higher than maximum permissible
current of the terminal.
(2) Slightly draw the electric wire to determine fastening state and connecting state of jack.
(3) Leave electric wire long enough for conditions of contact moving, or cover opening for
fault handle or inspecting etc..
(4) Figure 2-1 is outline drawing of control box (for function description, please refer to STEP
control box manual).
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 36/N
(5) When connect 2 strands of electric wire end terminal to another, keep maximum contact
face between terminals. Please not make wire connecting angle become higher than 60˚.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 38/N
60˚
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 39/N
(1) If fault is related to input power supply, please inspect following content.
1) The 1st side: ⓐ R-S, ⓑ R-T, ⓒ S-T
nd
2) The 2 side: ⓓ R1-S1, ⓔ R1-T1, ⓕ S1-T1
If measured voltage (ⓐ) of the 1st side and measured voltage (ⓓ) of the 2nd side are
higher than 2% of service voltage, cut off MCCB of building distributor box, and measure
resistance between R-R1 after opening control box MCCB, measuring result should be
0[Ω] or near to 0[Ω].
(2) Measure rest S, T phase with method same with the one for R mentioned above. If there
is abnormal condition, please conduct accurate inspection and takes measures
(replacing) according to inspection results.
(3) Measure peak (p.m. 3~4 o’clock, 8~9 o’clock) voltage in each summer and ordinary (a.m.)
voltage, and record measuring results on the daily inspection record.
(4) After cutting off the power supply and implementing Lock Out / Tag Out, inspect whether
MCCB surface discolors; and determine whether its temperature is normal after
measuring the temperature.
(5) Please determine whether there is abnormal noise or vibration inside MCCB.
3.2.3 Determine voltage and fuse
Inspection
Part Inspection item Tool State/standard
circle
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 40/N
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 41/N
(1) Please determine whether electric wire used for wiring has excess part.
(2) Please determine whether changeable tension device could be started smoothly.
(3) Please determine whether there is serious arc trace occurs for abnormal abrasion
(irregular abrasion) of contact point.
(4) Please determine ON / OFF action of electronic contactor.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 42/N
도면 3.18 제어电路端子
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 43/N
2) Switch function
Switch
No. State Function Remark
name
On ARM Program start Setup state: OFF
1 ARM Normal working Note: when start
Off program, start CPLD
state
firstly → and set
SW1 On DSP Program start SW1 to be ON→
DSP program start→
2 DSP Normal working ARM program start
Off
state (start window is
different)
SW2 CAN Terminal SW2 assembly state:
On OFF
SW3 resistance setup
SW3/SW4
SW4 CAN Terminal
Off assembly state: ON
resistance invalid
RS485 Terminal
On
resistance setup
SW5 assembly state: ON
RS485 Terminal
Off
resistance invalid
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 44/N
Mic Connected
Name Function Default
name Wire num
1 X0 Auto/Inspection input signal default
2 X1 X0 and X1 all input→automatic default
JP1
3 X2 Up signal default
4 X3 DN signal, default
1 X4 2LS(SDS1U) close
2 X5 1LS(SDS1D) close
3 X6 4LS(SDS2U) close
4 X7 3LS(SDS2D) close
GOV CTT contact point input
5 X8 open
JP2 signal
KMZ CTT contact point input
6 X9 open
signal
FR CTT contact point input
7 X10 open
signal
8 X11 open
1 X12 UL(up limit switch) close
2 X13 DL(down limit switch) close
3 X14 2LV(level switch signal) open
JP3
4 X15 1LV(level switch signal) open
5 X16 close
6 X17 open
1 x18 Fireman(fire-hazard reset switch) open
2 x19 Fireman Service fireman switch open
3 x20 SW CTT contact point input open
4 x21 signal open
JP4
5 x22 BY CTT input signal open
6 x23 BS1 switch signal (left) open
7 x24 BS2 switch signal (right) open
8 x25 MTH signal input open
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 45/N
Mic Connected
Name Function Default
name Wire num
1 x28 UCM1,2 CTT contact point input open
2 x29 KAD CTT contact point input open
FIRE1 CTT contact point input
3 x30 open
(the 1st fire-fighting)
JP5
FIRE2 CTT contact point
4 x31 nd open
input(the 2 fire-fighting)
X0~X31 input signal common
5 COM
terminal
0VDC power input terminal
1 GND
(used for CTT input circuit)
24VDC power input terminal
2 24V
(used for CTT input circuit)
JP6
0VDC power input
3 GND
(used for CTT output circuit)
24VDC power input
4 24V
(used for CTT output circuit)
1
2
JP7 3 CAN1H Tandem communication signal
(TXA1+)/(TXA1-)
4 CAN1L
(Car & Hall CAN communication)
1 +24V
2 0V
JP8
3 CAN2H Parallel or group-control tandem
4 CAN2L signal (TXA2+) (TXA2-)
1 +24V
JP9 2 0V
3 CAN3H
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 46/N
4 CAN3L
JP10 1
MODEM telemonitoring
JP11 1 interface; ARM tandem guiding
window
Could be connected with RS232
JP12 1 interface portable governor; DSP
tandem guiding window
Mic Connected
Name Function Default
name Wire num
1 Y14B Output
2 Y14A Output
3 COM6 Output
JP13 4 Y15B Fire-fighting reset indicating Output
5 Y15A Fire-fighting reset indicating Output
Fire-fighting reset output relay
6 COM7 Output
Y15 common terminals
1 Y8 FIRE1 CTT output terminal Output
2 Y9 FIRE2 CTT output terminal Output
3 Y10 UCM1,2 CTT output terminal Output
4 Y11 DZI Lamp output terminal Output
JP14 Output relay Y8-Y11 common
5 COM4
terminals
6 Y12 Output
7 Y13 Output
8 COM5
1 Y4 FR CTT output terminal Output
2 Y5 Output
Output relay Y4-Y5 common
JP15 3 COM2
terminals
4 Y6 Output
5 Y7 Output
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 47/N
6 COM3
1 Y0 BY CTT output Output
2 Y1 KMZ CTT output Output
3 Y2 Output
JP16
4 Y3 SW CTT output Output
Output relay Y0-Y3 common
5 COM1
terminals
Used for inspecting abnormal
1 X32 In-put
conditions of safety circuit
Used for inspecting abnormal
2 X33 In-put
conditions of landing door circuit
JP17 Used for inspecting abnormal
3 X34 In-put
conditions of CAR door circuit
4 X35 In-put
X32-X35 input signal common
5 COM
terminal 0V
JP25 CPLD program JTAG guiding window
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 48/N
Specification
W phase signal
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 49/N
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 50/N
JP1
JP5
SW1
SW3
JP3
JP2
JP7
DB1
JP6
SW2 JP4
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 51/N
JP4
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 52/N
Remark
Used for button connecting of F Used for button connecting of F Used for button connecting of F
1 car floor 9 car floor 57 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
2 car floor 10 car floor 58 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
3 car floor 11 car floor 59 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
4 car floor 12 car floor 60 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
5 car floor 13 car floor 61 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
6 car floor 14 car floor 62 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
7car floor 15 car floor 63 car floor
Used for button connecting of F Used for button connecting of F Used for button connecting of F
8 car floor 16 car floor 64car floor
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 53/N
JP3 2: 24V 4P
3:GND
JP4 4P
4: Input
JP5 4P
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 54/N
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 55/N
Input power
Earthing
Signal output
Signal output
Function
Signal output
Signal
Drive power
Earthing
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 56/N
TEST Used for confirming door action OPENED Used for confirming Open
state finish(OLS)
(Push to Check The Door) CLOSED Used for confirming Close finish,
3.2.7 Transformer
Inspection
Part Inspection item Tool State/standard
circle
Terminal/terminal relaxation, noise, he Naked eye 6 months
ating s
Transformer
Wire connecting of earthing wire, cap Naked eye 6 months
s
One side of the 1st and 2nd transformer is electrified, therefore, please conduct inspe
ction after cutting off power supply and implementing Lock Out /Tag Out.
(1) Please determine whether abnormal odor or over-heating state occurs.
(2) Please determine whether there is abnormal noise.
(3) Please determine whether Transformer bears over-load.
(4) Please determine whether there is dust or carbon powder between terminals, adopt
cleaning cloth or brush to clean up.
3.2.8 Regeneration resistance
Inspection
Part Inspection item Tool State/standard
circle
Naked No relaxation is
Fixing state of connecting part 6 months
Regeneration eyes allowed
resistance Heating and assembly state of cap Naked No relaxation is
3 months
(partition) eyes allowed
(1) Please determine whether electric wire connected on regeneration resistance is relax.
(2) Please determine whether over-heat condition occurs on regeneration resistance.
2005.12.27. Approval