If you wish to set up a tower in an area that does not have a grid power supply readily accessible, solar is a
good alternative.
You must capture more energy from the sun than you use.
Contents
[hide]
If you cannot find the watt rating of the device using google, you can use a multimeter or a very good device to
have on hand is a product called a kill-a-watt. A Kill-a-watt is a device with a similar shape to a surge protector
with a small screen. It tells you how many watts per hour the device that you plug into it will be using.
For reference
Powerstation 2 6.5w
Nanostation2 4w
Nanostation2 Loco 4w
Bullet2 4w
Picostation2 4w
Bullet2HP / Pico HP 8w
Another way to work out how much power a device uses, is to look at the wall wart or transformer.
The above transformer states that it has an output of 12 volts at 800 milliamps. To convert a voltage and amp
rating to watts, we multiply one by the other.
12v x 0.8a = 9.6 watts. - This transformer is capable of powering a device that uses up to 9.6 watts. The device
may not use 9.6 watts and so you would need to use a multimeter or kill-a-watt to get a more accurate
prediction.
Important Note:
You should always look for 12 volt equipment. If your device can not handle a 12 volt supply you will need to
get a 12volt DC to X volt DC Converter which means loosing some power during the conversion. The
abovementioned reference devices can handle a direct connection to a 12 volt battery which makes them
suitable for solar use.
Another important note is that you should only use DC devices. If the device's transformer says it has an AC
output, then it will have extra supply requirements that cost more and has a power loss through the DC to AC
conversion.
Once you have worked out the watt ratings of all your devices, add them together.
If we had a powerstation2 and a bullet2hp, we would be using a total of 14.5 watts per hour.
To work out how many watts per day, multiply the hourly usage by 24. For our example PS2 and B2HP, we are
using 348 watts per day.
Even with the discharge capability of a deep cycle battery, it should never drop below 50% of its capacity, but
can go several days or sometimes weeks without being recharged and still be as good as new.
A Deep cycle battery will have a rating on the side. It will specify a voltage - usually 6 or 12, and an Amp-Hour
/ Ah rating. More expensive batteries will have a higher Amp-hour rating and therefore have a larger capacity.
It is recomended that you purchase 12 volt batteries because your solar panels will most likley be 12 volt. If you
need to purchase 6 volt batteries, they can be wired in a special way to increase the voltage to 12. You can
purchase more batteries to add capacity as we will see below.
Wiring Methods
There are 2 ways to wire batteries together. You can use both at the same time if you like.
Parallel: This means that the Amp-Hour capacity of the batteries will be added together
Series: This means that the voltage of the batteries will be added together
In the example above of a PS2 and a B2HP, we need 4 days of 348 watts, multiplied by 2. This means our
battery bank capacity needs to be 2,784 watts.
To convert the watts back to amp-hours, we would divide by the battery voltage rating (12) so 2784 / 12 = 232
Ah total. Lets just round this to 240 Ah.
Types of Batteries
Flooded / Wet Cells: The older and more common type of deep cycle battery. Needs maintanence such
as water topups. Water is lost in gases when charging.
Gel or AGM: Are sealed and maintanence free. There is no gas lost becuase the battery case is sealed
and a special solar controller needs to be used so that the built up pressure from the gasses does not
damage the battery. Gel or AGM are able to deliver more power, faster and so are ideal for starting
engines or using on boats. They work well for our wisp radio towers too.
The solar panel will need to be able to capture enough solar power to run your equipment for the day, as well as
recharge your battery bank following a rainy or overcast period. It also needs to be able to do this during winter.
So if the example has 4 hours of sunlight to capture 24 hours worth of power (348 watts), thats a basic
requirement of an 87 watt solar panel. (348 / 4 = 87 watts per hour)
Now we need to factor in the recharging after a rainy or overcast period. If it rained for 4 days, and on the 5th
day it was sunny, thats 5 days worth of power that needs to be captured. In the example thats 1,740 watts worth
of power. We also need to capture this power as fast as possible before it rains again. So to capture 1,740 watts
of power during 4 hours of sunlight, that means we need a 435 watt panel. If we wanted to, we could set a goal
of recharging the batteries over 2 days. That means we have 8 hours to capture 6 days worth of power - which a
260 watt panel would be able to do. If you decide to set a longer recharge period, you can save some money on
solar panels, but will need to spend more on adding more capacity to your battery bank incase you only get one
sunny day and it returns to rain.
It is also probable that if you have an average of 4 hours of sunlight per day in winter, that also means half the
days will be rainy or overcast, and the other half would be sunny. This means that on the sunny day, there could
be up to 8 hours to capture the required power instead of the 4 assumed above. It is best to oversize your panels
just in case, so you should not rely too much on extra average sunlight hours from rainy days.
Polycrystalline: Are cheaper to produce, but are not as efficient as mono. Panels are usually larger for
the same watt rating.
Monocrystalline: Are more expensive to produce but are more efficient than poly and can capture the
more watts per square foot of solar cells.
Overcast Days: Some panels will still capture solar energy when there is a light overcast of cloud (bright white
clouds) and they can sometimes work at up to 40% of the panel's rating. You may be interested in checking
how your panel performs by using a multimeter and testing the panel's output on an overcast day.
Prevents power from the battery traveling back up and getting lost through the solar panel at night
Prevents the panels from overcharging the battery by disconnecting them when the battery is full
Gives an indication on the battery bank's State Of Charge
Stops the batteries from being discharged too much by disconnecting your devices when the battery
SOC gets too low.
Counts how much power you have generated and how much power your devices have used
Helps lower the amount of maintanence work required on your batteries by charging in certain ways
Old solar controllers used to be called solar regulators. This is simply because they stopped the battery getting
overcharged and would simply use a relay and volt metre to check when to disconnect or reconnect the panel.
You will want to make sure you get a solar controller that will display the State of charge for your battery bank.
This helps diagnose problems if your tower stops working and your customers need it fixed urgently.
You will want to mount your panel so its surface is perpendicular to the sun's rays during winter.
During winter, the sun will be on a lower angle than in summer. Because there is more sunlight hours in
summer, we are not too concerned if the panel is less efficient because of its angle but in winter, it makes more
of a difference. You should therefore mount your solar panel so it is most efficient in the winter.
Here is a link to a website that further explains how to mount your solar panel and calculate the angles. It gives
examples for a hot water solar collector but the angles will be the same for a solar power panel.
Solar Direct's Angle Guide
A portable generator of around 300 watt with 12v DC and mains AC outputs - make sure the amp output
of the 12v is less than your solar controllers limitation.
A few backup batteries or pairs of batteries to swap into to your bank to run your tower for 2 days.
The first step would be to check the solar controller. Some with lcd screens will show an error code to help you
diagnose the problem. If its just been raining too long then you will need to add another solar panel and expand
the size of your battery bank to prevent it from happening again.
You can disconnect your solar panels, and connect the solar panel input of your solar controller to the 12v
output of the generator and safely charge the battery bank and run your tower again. For faster charging, you
would disconnect the batteries from the solar controller and directly connect them to the 12v output of the
generator.
Another way is to take out some fully charged batteries from your workshop and connect them in parallel to
your battery bank - this will flow on to power your devices and slightly charge some of your batteries.
No matter what you do to get it going, the fact is that you have to work out what caused the issues, fix it as soon
as possible and power up your tower or risk loosing customers. It is not a good for your customer's internet
access to disconnect after x amount of days of rain because your battery bank is not big enough to suit your
local area.