General notes:
1. Design parameters:
1.1 Wind velocity = 57mps, 3s gust wind speed
1.2 Wind loads as per ANSI/TIA-222-G
1.3 Antenna loading: 6.65sqm over top 10m of the tower
3pcs antenna
1.4 Exposure category = C
1.5 Topographic category = 1
1.6 Classification of tower = Ⅱ
1.7 Max. twist & sway < 0.5 degree under 70%*57mps
2. Material
2.1 Tower structure shall be Q355B&Q420B for legs, splice
plates,tower shoes and anchor bolts. And Q235B for other
members.
2.2 Bolts shall be ISO grade 8.8 or equivalent.
3. Galvanizing and erection
3.1 Galvanizing to be in accordance with ISO 1461 specifications.
3.2 All components include bolts shall be hot dip galvanized.
3.3 Tower anchor bolts shall be embedded truly aligned and
leveled
with the aid of template.
4. All dimensions are in mm unless otherwise specified.