0% found this document useful (0 votes)
37 views

Zelio Time RE22R1AMR Document

This document provides product specifications for a modular timing relay made by Schneider Electric. The key details are: - It is a modular timing relay with 8A current, adjustable time delays from 0.05 seconds to 300 hours, and 1 changeover contact. - It has a rotary knob and diagnostic button for control, and accepts 24-240V AC/DC power supply. - Environmental specifications include operating temperature range of -20°C to 60°C, IP40 housing protection, and compliance with various EMC standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views

Zelio Time RE22R1AMR Document

This document provides product specifications for a modular timing relay made by Schneider Electric. The key details are: - It is a modular timing relay with 8A current, adjustable time delays from 0.05 seconds to 300 hours, and 1 changeover contact. - It has a rotary knob and diagnostic button for control, and accepts 24-240V AC/DC power supply. - Environmental specifications include operating temperature range of -20°C to 60°C, IP40 housing protection, and compliance with various EMC standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Product data sheet RE22R1AMR

Characteristics Modular timing relay, 8 A, 0.05 s…300 h, 1 CO,


power on delay , 24...240 V AC/DC

Main
Range of product Zelio Time
Product or component Modular timing relay
type
Discrete output type Relay
Device short name RE22
Nominal output current 8 A

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Complementary
Contacts type and composition 1 C/O timed contact, cadmium free
Time delay type A
Aw
Time delay range 3...30 s
30...300 s

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
10...100 s
0.05...1 s

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1...10 s
30...300 h
30...300 min
0.3...3 s
3...30 h
3...30 min
Control type Rotary knob
Diagnostic button
[Us] rated supply voltage 24...240 V AC/DC 50/60 Hz
Release input voltage <= 2.4 V
Voltage range 0.85...1.1 Us
Supply frequency 50...60 Hz +/- 5 %
Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable
end
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable
end
Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Tightening torque 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale 25 °C IEC 61812-1
Control signal pulse width 100 Ms with load in parallel
30 ms
Insulation resistance 100 MOhm 500 V DC IEC 60664-1
Recovery time 120 ms on de-energisation
Immunity to microbreaks 10 ms
Power consumption in VA 3 VA 240 V AC
Power consumption in W 1.5 W 240 V DC
Switching capacity in VA 2000 VA

Jan 13, 2021


1
Minimum switching current 10 mA 5 V DC
Maximum switching current 8 A
Maximum switching voltage 250 V AC
Electrical durability 100000 Cycles, 8 A 250 V, AC-1
100000 cycles, 2 A 24 V, DC-1
Mechanical durability 10000000 cycles
Rated impulse withstand voltage 5 kV 1.2…50 µs IEC 60664-1
Power on delay 100 ms
Creepage distance 4 kV/3 IEC 60664-1
Overvoltage category III IEC 60664-1
Safety reliability data MTTFd = 308.2 years
B10d = 280000
Mounting position Any position
Mounting support 35 mm DIN rail EN/IEC 60715
Status LED Green LED backlight steady)dial pointer indication
Yellow LED steady)output relay energised
Yellow LED fast flashing)timing in progress and output relay de-energised
Yellow LED slow flashing)timing in progress and output relay energised
Maximum Width 0.89 in (22.5 mm)
Net Weight 0.22 lb(US) (0.1 kg)

Environment
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic
insulation IEC 61812-1
Standards UL 508
IEC 61812-1
Directives 2006/95/EC - low voltage directive
2004/108/EC - electromagnetic compatibility
Product certifications CE
UL
GL
CCC
EAC
RCM
CSA
Ambient air temperature for operation -4…140 °F (-20…60 °C)
Ambient air temperature for storage -40…158 °F (-40…70 °C)
IP degree of protection Housing IP40 IEC 60529
Front face IP50 IEC 60529
Terminals IP20 IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Vibration resistance 20 m/s² 10…150 Hz)IEC 60068-2-6
Shock resistance 15 gn not operating 11 ms IEC 60068-2-27
5 gn in operation 11 ms IEC 60068-2-27
Relative humidity 95 % 77…131 °F (25…55 °C)
Electromagnetic compatibility Fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC
61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC
61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC
61000-4-5
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to
IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC
61000-4-2
Radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1
GHz)level 3 IEC 61000-4-3
Conducted RF disturbances 10 V 0.15...80 MHz)level 3 IEC 61000-4-6
Fast transient bursts 2 kV direct contact)level 3 IEC 61000-4-4
Immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11
Immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11

2
Ordering and shipping details
Category 22376 - RELAYS-MEASUREMENT(RM4)
Discount Schedule CP2
GTIN 00785901451709
Nbr. of units in pkg. 1
Package weight(Lbs) 0.2 lb(US) (0.09 kg)
Returnability Yes
Country of origin ID

Packing Units
Package 1 Height 0.260 dm
Package 1 width 0.820 dm
Package 1 Length 0.950 dm

Offer Sustainability
Sustainable offer status Green Premium product
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and
lead compounds, which is known to the State of California to cause cancer
and birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS
Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information

3
Product data sheet RE22R1AMR
Dimensions Drawings

Dimensions

4
Product data sheet RE22R1AMR
Connections and Schema

Wiring Diagram

5
Product data sheet RE22R1AMR
Technical Description

Function A: Power On-Delay

Description
On energisation of power supply, the timing period T starts. After timing, the output(s) R close(s).The second output (R2) can be either timed
(when set to "TIMED") or instantaneous (when set to "INST").

Function: 1 Output

Function: 2 Outputs

Function Aw : Power On-Delay With Retrigger / Restart Control

Description
On energisation of power supply, the timing period T starts.At the end of the timing period T, the output(s) R close(s).Energization of Y1
makes the output(s) R open(s).Deenergization of Y1 restarts timing period T.At the end of timing period T, the output(s) R close(s).The
second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST")

Function: 1 Output

Function: 2 Outputs

Legend
Relay de-energised
Relay energised
Output open
Output closed

6
U Supply
-
T- Timing period
R1/ 2 timed outputs
R2
-
R2 The second output is instantaneous if the right position is selected
inst.
-
Y1 Retrigger / Restart control
-

You might also like