0% found this document useful (0 votes)
78 views5 pages

Brazzoli ValvesLST

This document provides information about pneumatic valves and sensors for an Innodye HT dyeing machine. It lists the function, identification numbers, and remarks for over 50 pneumatic valves. It also lists digital and analog sensors for monitoring aspects of the machine like temperature, levels, flow, and feedback for pumps and rollers. Finally, it outlines a dye program format with a series of yes/no questions to control processes like preparing and mixing tanks, filling and heating an auxiliary tank, and transferring materials between the machine and tanks.

Uploaded by

Samar Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views5 pages

Brazzoli ValvesLST

This document provides information about pneumatic valves and sensors for an Innodye HT dyeing machine. It lists the function, identification numbers, and remarks for over 50 pneumatic valves. It also lists digital and analog sensors for monitoring aspects of the machine like temperature, levels, flow, and feedback for pumps and rollers. Finally, it outlines a dye program format with a series of yes/no questions to control processes like preparing and mixing tanks, filling and heating an auxiliary tank, and transferring materials between the machine and tanks.

Uploaded by

Samar Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

APC-504 – BRAZZOLI

INNODYE HT MACHINE GENERAL

PNEUMATIC VALVES LIST

FUNCTION
.AREL No BRAZZOLI No REMARKS

MACHINE

FILL 1 V1
101
FILL 2 V2
102
FILL 3 V3
103
FILL ISOLATE V4
182 MOD, 4-20mA

OVERFLOW V5
107
VENTILATION V10C
140
NORMAL DRAIN V7A 111A

POWER DRAIN 1 V7D


111
POWER DRAIN 2 V7DW
112
.DRAIN INTERM V72
748
SPRAY VALVE VSPRAY 176A

TURBO VARIO VTV 186P/A MOD 4-20mA

DRAIN COOL RINSE VDCD 111B

AIR RELEASE V10


108

HEAT EXCHANGER

HEAT VH
116 MOD 4-20mA

COOL VC
117 MOD 4-20mA

DIRECT COOL VDC


134

AUX. TANK

.FILL AUX. ISOL V4A


750
TRANSFER V25
745
DRAIN V24
711

Page 1
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

FUNCTION
.AREL No BRAZZOLI No REMARKS

HEAT VH20
716

TANK 1

RINSE VT6
131
RECIRCULATION VT6A
141
TRANSFER VT1
145
.RECIRCULATE TO AUX VT6B 141A

TANK 2

RINSE VT7
401
RECIRCULATION VT7A
451
TRANSFER VT2
431
DOSING TO TANK 1 VDOS21 136A

DRUG ROOM

SLOW TRANSFER TO MACHINE VT9S


136
FAST TRANSFER TO MACHINE VT9
137
DRAIN VDR
146
.TRANSFER TO AUX VT9A
738

MOTORS

MAIN PUMP P
201 DIGITAL OUT. + 4-20mA

ROLLER 1 R1
231 DIGITAL OUT. + 4-20mA

ROLLER 2 R2
232 DIGITAL OUT. + 4-20mA

ROLLER 3 R3
233 DIGITAL OUT. + 4-20mA

PUMP CHARGE TANK PTA


730 .DIGITAL OUT
PUMP TANK 1 PT1
203 .DIGITAL OUT
PUMP TANK 2 PT2 203A
.DIGITAL OUT
MIXER TANK 1 MIX1
241 .DIGITAL OUT

Page 2
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

FUNCTION
.AREL No BRAZZOLI No REMARKS

MIXER TANK 2 MIX2


511 .DIGITAL OUT

DIGITAL SENSORS

FLOWMETER FW
282 PULSE DRY CONTACT

FEEDBACK MAIN PUMP FBP DRY CONTACT

FEEDBACK ROLLER 1 FBR1

FEEDBACK ROLLER 2 FBR2

FEEDBACK ROLLER 3 FBR3

SEAM 1 SM1

SEAM 2 SM2

SEAM 3 SM3

ANALOG SENSORS

PT100 MACHINE TEMPERATURE SNS. PT100A

PT100 CHARGE TANK TEMP. SNS PT100B

MACHINE–ANALOG LEVEL SENSOR LMA 4-20mA

CHARGE TANK–ANALOG LEVEL SENSOR LTAX 4-20mA

TANK 1–ANALOG LEVEL SENSOR LTA1 4-20mA

TANK 2–ANALOG LEVEL SENSOR LTA2 4-20mA

"N.C." - for normally closed valve, spring return Legend:


N.O." - for normally open valve, spring return"
D.A." - for double acting valve"
MOD." - for modulating valve"

Page 3
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

DYE PROGRAM FORMAT

Yes / No............................................................ PREPARE TANK 1

Yes / No................................................................... MIX TANK 1

Yes / No............................................................ PREPARE TANK 2

Yes / No................................................................... MIX TANK 2

Yes / No........................................PREFILL TANKS WITH FRESH WATER

Yes / No............................................. PREFILL TANKS FROM MACHINE

Yes / No..................................... POST FILL TANKS WITH FRESH WATER

Yes / No...........................................POST FILL TANKS FROM MACHINE

_ _.............................................OPERATOR MESSAGE PREPARE


Yes / No.......................................... TRANSFER TANK 1 TO AUX. TANK

Yes / No.......................................... TRANSFER TANK 2 TO AUX. TANK

Yes / No............................................. FILL AUX. WITH WATER TYPE 1

Yes / No............................................. FILL AUX. WITH WATER TYPE 2

Yes / No............................................. FILL AUX. WITH WATER TYPE 3

_ . _ _.............................................................. FILL AUX. RATIO


._ _ _ _ L......................................................... FILL AUX. QUANTITY
_ _ _Deg.C............................................................. HEAT AUX. TANK

Yes / No............................................................ MIXER AUX. TANK

Yes / No.....................................RECIRCULATION TANK 1 TO AUX. TANK

_ _ _Deg.C............................................................ DRAIN AUX. TANK

Yes / No...........................WAIT FOR HEAT AUX. TANK BEFORE TRANSFER

Yes / No........................................ TRANSFER AUX. TANK TO MACHINE

Yes / No........................................ FILL MACHINE WITH WATER TYPE 1

Yes / No........................................ FILL MACHINE WITH WATER TYPE 2

Yes / No........................................ FILL MACHINE WITH WATER TYPE 3

_ _.................................................................... FILL RATIO


._ _ _ _ L............................................................... FILL QUANTITY
Yes / No............................................................... FILL TO LEVEL 1

Yes / No.............................................................. FILL TO LEVEL 2

Yes / No.............................................................. FILL TO LEVEL 3

Yes / No................................................................. LOAD FABRIC

_ _............................................... OPERATOR MESSAGE - LOAD


Yes / No...................................................... MACHINE PRESSURIZE

Page 4
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

% _ _ _........................................................... MAIN PUMP SPEED


% _ _ _................................................................ ROLLER SPEED
Yes / No................................................................. SPRAY VALVE

Yes / No........................................................... WORK BY CYCLES

._ _._ Deg.C /min.......................................................................... RATE


_ _ _ Deg.C............................................................... TEMPERATURE

Yes / No.................................................................. COOL RINSE

Yes / No............................................... HEAT CONTROL IN TRANSFER

Yes / No..................................................... RECIRCULATION TANK 1

Yes / No..................................................... RECIRCULATION TANK 2

Yes / No........................................................... TRANSFER TANK 1

Yes / No........................................................... TRANSFER TANK 2

._ _ _ min................................................................. DOSING TIME


_ _.............................................................. DOSING CURVE
Yes / No........................................................ DOSING FROM TANK 1

Yes / No........................................................ DOSING FROM TANK 2

_ _ _ min.................................................................... HOLD TIME

Yes / No................................................. RINSE WITH WATER TYPE 1

Yes / No................................................. RINSE WITH WATER TYPE 2

Yes / No................................................. RINSE WITH WATER TYPE 3

._ _ _ _ L............................................................. RINSE QUANTITY


_ _.................................................................. RINSE RATIO
._ _ _ min.................................................................... RINSE TIME
Yes / No.........................................CONTROLLED RINSE BY FILL VALVE

Yes / No.................................................................... SAMPLING

_ _....................................................... OPERATOR MESSAGE


Yes / No.................................................................. UNLOADING

Yes / No........................................UNLOADING WITH SEAM DETECTION

_ _....................................................... OPERATOR MESSAGE


Yes / No................................................................... FULL DRAIN

Yes / No............................................................... POWER DRAIN 1

Yes / No............................................................... POWER DRAIN 2

Page 5