Kobelco Error Codes
Kobelco Error Codes
Last 2-3 High pressure Proportional valve Proportional valve Potentiometer Battery
Controller memory Low pressure sensor Solenoid valve Speed sensor Communication Relay output
digits sensor for valves for pumps etc relay
Engine adjust Battery Wiper ark
01 Boom up P1 pump P1 unload P1 pump ATT boost Acceleration
data relay prevention relay
Torque adjust Wiper ark forward
02 Boom down P2 pump P2 unload P2 pump Swing parking Boom angle
data rotation relay
Unload adjust Angle sensor for Wiper ark reverse
03 Arm out Boom head Travel straight Travel 1,2 speed Arm angle
data shovel rotation relay
Boom up adjust Angle sensors for
04 Arm in Boom rod Option selector Washer motor
data shovel & ECU
Arm in adjust
05 Bucket digging Bucket stroke limit
data
Arm out adjust Arm 2 spool for
06 Bucket dump
data arm in
07 Swing
08
09 Travel right Fuel sensor
10 Travel left
Selector position CAN
11
detection communication
12
Swing flasher right
13
relay
Swing flasher left
14
relay
15 Travel alarm relay
24 Hourmeter sector 2
Proportional valve
25
adjust data
Cluster
31
communication
Larger than normal Larger than
0
range normal range
Transistor OFF
1 failure / Grounding CAN error
short circuit
Transistor ON Transistor ON
2 Wrong output Wrong output Over run
failure failure
Transistor ON
3 Disconnection Disconnection Disconnection Disconnection failure / Disconnection Disconnection Time is over
Disconnection
Power source short Power source Power source Power source short
4
circuit short circuit short circuit circuit