A B C D A B C D A B C D: Roof Storm Layout Ground Floor Storm Layout Second Floor Storm Layout

The document outlines specifications for a drainage system including pipe dimensions and materials. It lists the dimensions of various pipes including their diameters, lengths, and materials. The system includes 3-inch diameter downspout pipes of various lengths that connect and drain water from different parts of a structure.

Uploaded by

Denzel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views

A B C D A B C D A B C D: Roof Storm Layout Ground Floor Storm Layout Second Floor Storm Layout

The document outlines specifications for a drainage system including pipe dimensions and materials. It lists the dimensions of various pipes including their diameters, lengths, and materials. The system includes 3-inch diameter downspout pipes of various lengths that connect and drain water from different parts of a structure.

Uploaded by

Denzel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A

A B C D A B C D A B C D 4
8000 75
8000 1850 9850
3
12
3"Ø
DO 395
PIP WN 0
B
3950 4050 75
3950 1500 2550 3950 1500 2550 1850
3"Ø DOWNSPOUT
PIPE
3"Ø DOWNSPOUT
PIPE
25 E SP
OU
T
80
00 C
3"Ø DOWNSPOUT 3"Ø
4"Ø DRAINAGE PIPE @2% SLOPE BALCONY D

1275

1275

1275

1275
DO
PIPE
CB
CB
3"Ø DOWNSPOUT
PIPE
3"Ø FD 3"Ø DOWNSPOUT
PIPE
5.03 SQ.M 3"Ø DOWNSPOUT
PIPE
2 12
45
0
39
25 PIP WN 4
E SP 050
OU
T
3"Ø FD

4
4

4
CB 8 9 10 11 12 8 9 10 11 12 7
7 7 6 8 9
LAUNDRY AREA COMMON 13 13
4 5 10

1200
11
COMMON
T&B
3.00 SQ.M T&B 6
5
14
15
6
5
14
15
1 40
0 0
1
2 3
1
15 4
12
13
12
75

2575

2575

2575

2575
3"Ø 16

3"Ø DOWNSPOUT PIPE


4 16 4 16 FD
67
5 RO

3500
3 3 42. OF

4"Ø DRAINAGE PIPE @2% SLOPE

1375
KS BEDROOM 1 2 2 52 DE
TERRACE SQ C
15.405 SQ.M 3"Ø FD .M K
1 1
9.415 SQ.M 3"Ø

3
3

3
FD
925

925
3"Ø FD 0 5
50 77

1125
3"Ø FD 10 11

1325

3"Ø DOWNSPOUT PIPE


39

3"Ø DOWNSPOUT PIPE


50
KITCHEN & 3"Ø
3A

FD
DINING AREA 80

3925

3"Ø DOWNSPOUT PIPE


11775
00

1500
17.10 SQ.M

12450
40
LANAI
3000

3000
50

2800
T&B BEDROOM 2 ROOF DECK

10500
DN
CARPORT 5.60 SQ.M
7.15 SQ.M 42.52 SQ.M

3"Ø DOWNSPOUT PIPE


41.475 SQ.M

14450

14450
1100
3"Ø FD
12425

12425
3"Ø FD
CB
4 A

2
2

2
MASTER
BEDROOM 75
3 132"Ø
DO

4"Ø DRAINAGE PIPE @2% SLOPE


UP DN 17.335 SQ.M PIP WN

2700
25
75 E S PO
UT 39
50
B
BA
C

3875
4000

4000

4000
5.0 L
LIVING AREA 25 3 S CON
13.85 SQ.M 2 00
13 4"Ø
ST SO
AC IL
B
Q.M S Y4"Ø
TA S
CK OIL 15
00
98
50

45
0 15 K
15. EDR D

5925
14 00 405 OO
11 4"Ø SQ M PIP
E FD CO 3"Ø 25
FD .M 1 DO 50

1375
PIP N
4"Ø
T& MMO
N E PIP WN

1
WC
3"Ø FD BALCONY 3"Ø FD 0 0 T& FD
N CO CO FD
N
WC
B N7 E SP
O
27 B LA LA 8 9 3 UT
5.45 SQ.M V V 5 6 10 "Ø F 18

1
1

1
50
3 4 11 D
12
1 2

675
2"Ø DOWNSPOUT 75
B MA TE 13
13
PIPE
17. EDR STE 9.4 RR 14
335 O R 15
SQ ACE 16 15
PORCH

2050
1925

DN
CB 00 SQ OM 3"Ø .M 12
75
UP 26 .M FD
8.00 SQ.M

2675
2600

3"Ø DOWNSPOUT PIPE


BE

4"Ø SOIL STACK


B DR
5.4 ALC
3"Ø FD 7.1 75
5 S ON 5 S OO 25
Q.M Y Q.M M
2"Ø DOWNSPOUT 2
PIPE 25
11

0 0
3950 4050 28
1700 2350 TO SIDE 925 775 2350 39
5
3"Ø
4 50
DRANAGE 8000 0 D 14
PIPOWN

3"Ø DOWNSPOUT PIPE

3"Ø DOWNSPOUT PIPE


3950 4050 1850 3950 4050 E S

3"Ø DOWNSPOUT PIPE


PO

3"Ø DOWNSPOUT PIPE


3"Ø UT
92 D 0 0
5 40

4"Ø SOIL STACK


9850 8000 80 77 PIPOWN
00 5 E S PO
UT
40
1 GROUND FLOOR STORM LAYOUT 2 SECOND FLOOR STORM LAYOUT 3 ROOF STORM LAYOUT
50 23
50

26
75
SCALE 1:100 m. SCALE 1:100 m.
P 2 P 2 P 2 SCALE 1:100 m.

4 A
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE 12. WATER METER SHOULD BE LOCATED OUTSIDE THE PROPERTY LINE. 3"Ø
EXECUTED IN ACCORDANCE TO THE REQUIREMENTS 3 5
S
TAEPT
NK IC
DO
PIP WN
E S
OF THE PHILIPPINE PLUMBING CODE. 13. WATER SUPPLY FOR CISTERN AND SUPPLY LINE TO THE BUILDING
MUST BE LOCATED ALONG PERIMETER FENCE 400m. HEIGHT ABOVE LEGENDS: 3A
257 PO
CB UT
4"
Ø
6"Ø DRA
39
50
B
2. COORDINATE THE DRAWING WITH OTHER RELATED DRIVEWAY LEVEL WITH 3 LAYERS OF JUTE SACK AND BLACK COAL TAR.
92
5
4" ØP
IPE PIP INA
E GE 80
00 C
DRAWINGS AND SPECIFICATIONS. THE ENGINEER SHALL
BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY
PITCH OR SLOPE OF PIPE LINE: USUALLY, THE WASTE PIPE IS BALL/GATE VALVE
WC WATER CLOSET
CB CATCH BASIN
2 00
0
PIP
STE4"@Ø2
AC S %
K OSILLO
15
00

FOUND THEREIN.
14. WATER LINE LAYOUT FOR WASHROOM TO SUPPLY UNITS. INSTALLED AT 2% OR 20mm SLOPE PER METER RUN. WATER LINE
UR URINAL
HB
KS
HOSE BIBBED FAUCET
KITCHEN SINK
12
42
5 3 CO
ST4"Ø
AC SO
K IL E
CO PE
CB 3
"Ø 25
D
15. ALL WATER LINE SUPPLY FOR WASHROOMS SHALL NOT BE EMBEDDED IN SOIL PIPE PIP FD
N CO DO 50
3. THE PLUMBING LAYOUT IS ONLY DIAGRAMMATIC. PIPES LAV LAVATORY 4"Ø PIP WN
AC AIR CHAMBER
T& MMO
SLAB, BLOCKS OUT SHALL BE PROVIDED FOR POSSIBLE DIRECTION OF PIPES.
1 00
CO FD WC E SP
OU

3"Ø DOWNSPOUT PIPE


CLEANOUTS AND CHECK VALVES SHALL BE CONCEALED. STORM DRAIN PIPE FCO FLOOR CLEANOUT N B NL 18
40 LA T AU 50

3"Ø DOWNSPOUT PIPE


ST SEPTIC TANK CA V
16. ALL FINAL LOCATION OF TOILET FIXTURES SHALL BE BASED ON THE FD 4 RP
41. 3.0 NDR
4. ALL SLOPE OF HORIZONTAL BRANCHES (SEWER) VENT PIPE FLOOR DRAIN F FAUCET 75 OR 0S Y
SQ T Q.M AR
MAINTAIN 1% A MINIMUM, UNLESS NOTED OTHERWISE. MODULAR SETTING OF TILES. .M E A CB
WYE STRAINER SHO SHOWER HEAD 5
2
DINKITC

2%
DS DOWNSPOUT 19 KS
5. AIR CHAMBER : ALL INDIVIDUAL BRANCHES TO FIXTURE 17. DOUBLE DRAINS FOR BATH TUBS. 17. ING HEN LO
P E
10 S
OR GROUP OF FIXTURES AND/OR EQUIPMENT SHALL SQ ARE & E@
2%
18. DOWEL FOR DOWNSPOUTS AND REINFORCEMENT 10mmØ @ 600mm STAGGERED .M A IP
BE PROVIDED WITH AIR CHAMBER OF CAPPED VERTICAL EP 00
UP AG 12
PIPE EXTENSION OF DIMENSION AS SHOWN IN THE DETAIL. DN DR
AIN

6. ALL FLOOR DRAIN SHALL BE VENTED INDIVIDUALLY.


19. PVC CEMENT FOR JOINTS WITH EPOXY OUTSIDE BONDING. 7 PITCH OF PIPE LINE 700 LIV
IN 5.6 LAN
0 S AI
4"Ø
5
13
75
35
00
13.
20. RISER SHOULD NOT CROSS MASTER'S BEDROOM OR OTHER MAIN AREAS. SCALE NTS PROVIDE 85 G A CB Q.M 92
7. ALL CLEANOUTS SHALL BE FLUSH-MOUNTED TO WALL. DO P 2 12MMØ LIFTING UP SQ RE
ANGULAR . M A OP
E
NOT INSTALL FLOOR CLEANOUT EXCEPT AT LINES ON GRADE & EDGING HANDLE SL
SERVICE AREAS NOT SUBJECTED TO TRAFFIC. 21. GI. PIPE SHOULD BE PAINTED WITH RED LEAD OR BLACK COALTAR, 39 @
2% 00
FIN. FLR. LEVEL 50 IPE 30
IT SHOULD NOT BE EMBEDDED ON SLAB. SLEEVING OF PIPE IS REQUIRED P
8.0 OR E P
AG
8. ALL BRANCHES OF FIXTURE OR GROUP OF FIXTURES SHALL 0 S CH AIN 5
ON BEAM. FOLLOW WATER LINE LAYOUT AS PER PLAN. 17 Q .M DR
12
42
BE PROVIDED WITH AIR CHAMBER MADE OF CAPPED VERTICAL 00 4"Ø
75
CB 38
EXTENSION PIPE. VENT & DOWNSPOUT - 50 TO 150mmØ SHALL BE 98
5 40
0 23
50
POLYVINYL CHLORIDE (PVC) PIPE. 50 25
9. ALL UNDERGROUND GALVANIZED IRON (G.I.) INDIRECT CONTACT 15MMØ HOSE BIBB 59
12MMØ BARS @ 150
WITH SOIL SHALL BE PROVIDED WITH TWO(2) COATS OF TAR DRAINAGE LINE - 50 TO 150mmØ SHALL BE POLYVINYL O.C. BOTHWAYS 20
50
COVERING WRAPPED WITH JUTE CLOTH. CHLORIDE (PVC) PIPE.SERIES 1000. 1
DR TO 850
MANUFACTURED ACCORDING TO ASTM 2729 CHB WALL 100 600 100 AN SID
10. ALL PVC PIPE SHALL BE OF APPROVED QUALITY AND POLYPROPYLENE AG E
E
PIPES FOR WATER DISTRIBUTION SHALL BE TYPE 20. GATE VALVE
SEWER LINE - 50 TO 150mmØ SHALL BE 90° ELBOW
11. ALL PLUMBING WORKS THEREIN, SHALL BE UNDER THE POLYVINYL CHLORIDE (PVC) PIPE. SECTION OF CONCRETE COVER 4 SEWER AND STORM LINE ISOMETRIC LAYOUT
DIRECT SUPERVISION OF A REGISTERED MASTER PLUMBER AND/ SDR-35 MANUFACTURED
ACCORDING TO ASTM 3034.
OR A DULY LICENSED SANITARY ENGINEER. PLAN P 2 SCALE 1:120 m.
WATER LINE - SHALL BE POLYPROPYLENE (PPR) PIPE. 12MMØ LIFTING
PIPE DIAMETER - ALL PIPE DIAMETERS INDICATED IN (HOT & COLD) "BOR PLUS", "UNITEC", OR "VESBO" PROVIDE HANDLE
ANGULAR BAR 12MMØ BARS @ 150
THE DRAWINGS ARE INSIDE DIAMETERS. EDGING
5 GENERAL NOTES 800 O.C. BOTHWAYS
FIN. FLR. LEVEL
WATER DEMAND CONSUMPTION: SCALE N/A 100 600 100
P 2 90° ELBOW
A. NUMBER OF FIXTURE UNITS FLEXIBLE HOSE
SEWAGE (SEPARATE LINE) 15MMØ CWL

100
water closets=2x6dfu=12dfu SIZE OF MAIN WATER LINE:
GATE VALVE
lavatories=2x2dfu =4dfu CHB WALL 12MMØ BARS @ 200
floor drains=4x2dfu =8dfu a. Total no. of fixture units = 8- fu 12MMØ LIFTING
500

800
O.C. BOTHWAYS
kitchen sink =1x2dfu =2dfu From Hunter's Curve (International Plumbing Code). HANDLE
TOTAL SEWAGE =26dfu the equivalent liters per second requirement for
300

B.SIZE OF SEPTIC TANK: predominantly flush tank is 6.31 lps (100 gpm).
a. Average of Sewage Flow Rate per Day (in every one unit): b. For fairly rough pipe ( from graph: Uniform Plumbing Code or
from American Society of Heating, Refrigeration and Air Conditioning INLET PIPE OUTLET PIPE
1,170 liters/day is EQUIVALENT TO 26dfu from FIN. FLR. LEVEL
800
600

TABLE B-2 OF RA1378 Engineers manual), 100gpm at water velocity of 2.44 m/sec= 50
mmØ pipe
INLET PIPE
b. Total sewage flow rate per day = 1,170 liters/day OUTLET PIPE
=(1,170 liters per day) x 1.5= SEPTIC TANK SIZE Use 50 mmØ water supply pipe from Snta Ignacia Water District.
SLOPE
=1,755 liters per day=463.62gals per day= 1.755cum Note: Provide water backflow preventer before the water meter.
90° ELBOW
c. Size of Septic Tank

125
water closets=2x6dfu=12dfu 15MMØ CWL WRAPPED W/
Digestive Chamber = 1.755 m³ (minimum) lavatories=2x2dfu =4dfu
SECTION BURLAP COATED W/
100

12MMØ BARS @ 150


Leaching Chamber = 0.59 m³ (minimum) floor drains=4x2dfu =8dfu COALTAR IF BURRIED IN SOIL
O.C. BOTHWAYS
kitchen sink =1x2dfu =2dfu
SIZE OF CISTERN (if needed): TOTAL SEWAGE =26dfu 8 HOSE BIBB DETAIL 100 600 100
a. Average of Flow Rate per Day: 1,170 liters/day=309.10gals (WASTE GENERATION & WATER DEMAND) P 2 SCALE 1:15 m. PLAN SECTION
(Reserved for 3 days)
=927.3 gallons 6 COMPUTATIONS
9 CATCH BASIN DETAIL
=2000gallons=7.57 m³ (minimum) SCALE 1:15 m.
P 2 SCALE N/A P 2

RA 9266 SEC 33 CADD BY: REVISIONS PROJECT SHEET CONTENTS SHEET NO.
Ownership of plans, specifications, and other construction
documents. AS SHOWN
drawings and specifications and other contract
documents duly signed, stamped or sealed, as instruments of P
service, are the intellectual property and documents of the
architect, whether the object for which they are made is
executed or not. it is unlawful for any person to duplicate or to
make copies of said documents for use in the repetition of and CHECKED BY: LOCATION
2
for other projects of buildings, whether executed partly or in
PRC whole, without the written consent of the architect or author of
PTR TIN said documents.

DATE PLACE

You might also like