ATC Counter-376B
ATC Counter-376B
count. When the Batch Counter value equals the value in Preset
2, Output 2 will turn ON. The Batch Mode must be Manually
Reset (unless T2 is set to 00.00 (.5 w/AR) for Auto Reset).
TIMED OUTPUTS: The Outputs can be delayed before turning
OFF by setting time delay values for each output. Once the Preset
is reached, a time delay, according to the time value set, will
occur before the outputs turn OFF. This value can range from
0.00 SEC (OFF at Preset) to 99.99 SEC (Latched ON). In addition,
the outputs can also be set to turn OFF upon reaching the preset
for the other output in the Dual Preset Model.
SCALE FACTOR: A Prescale value can be set to allow viewing and
setting counts using real units of measure. The Prescale value is a
multiplier which is applied to the count in-put(s) to determine the
count display and preset values. The Prescale value can be set
from 0.00001 to 9.99999. In addition, the decimal point can be
set on the display to any one of 6 positions.
136
800.727.5646 automatictiming.com Automatic Timing & Controls 376B Series
\\\ SPECIFICATIONS
Single and Dual Preset with either NPN 10 kHz Count Up Mode
MODELS
(Solid State) or Relay Outputs.
9 kHz Count Down Mode
COUNT Bi-Directional MAXIMUM
Quadrature X1 Reduce by 3 kHz when Totalizing Counter
INPUT COUNTING
is enabled
MODES Quadrature X2 FREQUENCY
Quadrature X4 Reduce by 2 kHz when Auto Reset is enabled
(SWITCH Count with Inhibit Min. pulse 10 µSEC on; 90 µSEC off.
SELECTABLE) Interval with Start Input
Count, Batch, Totalizer
Presets 1 to 999,999 Min. 15 mSEC pulse
Scale Factor 0.00001 to 9.99999 REMOTE
SETTINGS Pulled to 5V via 8K ohm res.
RESETS
(FRONT OF 00.01 to 99.98 SEC Active Low. ViL = 0.5V Max.
PANELS Timed Outputs Latched Max. current = .625 mA.
Off at Preset
Current Sinking
Decimal Position 0 to 6
Count Up or Count Down OUTPUT - I sink = 100 mA Max.
Count/Go or Count/Stop SOLID STATE VoL = 1.0 VDC Max.
Sink or Source Count Input Max. Voltage = 30 VDC
High or Low Threshold (Bias) Life 100 million operations (no load)
High preset (Count Up) OUTPUT -
OPERATING RELAY 10 amp @ 30 VDC or 250 VAC,
Auto Reset at Zero (Count Down) Contact Rating
FEATURES 1/4 HP
After Timed Output
(SWITCH DC SUPPLY 12 VDC Regulated, ±4% Max. current = 120 mA
SELECTABLE) Totalizer
Non Volatile EEPROM
Dual Preset/Batch mode
MEMORY 230,000 Power Losses MIN
Access to Presets
Security lockout Access to T1, T2, SF, DP 10 Year Retention
Front panel Reset 8 Digit, 14 Segment
Reset on Power Up DISPLAY 5 mm x 4.1 mm
Sink - 9.4K ohm pull up Blue Vacuum Fluorescent
Max. current = 1.25 mA OPERATING
0° F to 140° F
Source - 4.7K ohm pull down TEMPERATURE
MODEL NUMBER > > > > > > 376B 50 ACCESSORIES
0353-260-27-00: Surface mounting bracket kit
Presets
0305-265-61-70: Round Cutout Retrofit kit
Single Preset 100 0376-320-01-00: Square Cutout Retrofit kit
Dual Preset (with batch) 200 0376-260-13-00: Magnetic Pickup Input Board
Voltage & Frequency 0376-260-14-00: Millisecond timer conversion Board
120, 50/60 Hz Q For prices and further information, consult factory.
240, 50/60 Hz R
Function
Counter with Sealing 50
Output Type
NPN Transistor L
Relay R
Features
Standard unit X
Special K
137
376B Series Automatic Timing & Controls automatictiming.com 800.727.5646
DIP SWITCH SETUP-To set up the Counter for operation, a series of DIP switches located inside the unit must be set.
Single/Dual Preset Counter // 376B Series