MICROFILTER
MICROFILTER
Pre- filter, General purpose filter and Superfine filter Grades VD (E), ZPD(E), XPD(E) and XP4(E)
V, ZP, XP, XP4 Complete with automatic drain and differential pressure gauge
Standard format with automatic condensate drain (E with volt-free contact)
T T T T
Activated carbon filter A & KTA Activated carbon filter AOP & KTAOP
Standard format with manual drain Compete with manual drain and oil indicator
T T T T
~190
~190
~190
~190
~195
~290
T T T T T T T T
Microfilter
Technical Data
Max. pressure
Filter element
Dimensions
Connection
Capacity*1
nominal
Weight
ZANDER (inches) (inches) (inches) (inches) Qty/
Type scfm NPT/Flg psi A B C D lbs Type
G 2 18 1/4” NPT 232 2.36 6.57 0.06 2.36 1.76 1/1030
G 3 29 1/4” NPT 232 3.43 8.23 0.83 2.95 3.30 1/1050
G 5 41 3/8” NPT 232 3.43 8.23 0.83 3.54 3.30 1/1070
G 6 50 1/2” NPT 232 3.43 8.23 0.83 3.54 3.30 1/1070
G 7 59 1/2” NPT 232 3.43 10.98 0.83 6.30 3.74 1/1140
G 9 106 3/4” NPT 232 5.12 12.40 1.69 5.31 9.46 1/2010
G 10 135 1” NPT 232 5.12 12.40 1.69 5.31 9.46 1/2010
G 11 177 1” NPT 232 5.12 16.34 1.69 9.25 11.00 1/2020
G 12 277 1 1/2” NPT 232 5.12 20.28 1.69 13.19 12.10 1/2030
G 13 412 1 1/2” NPT 232 5.12 28.15 1.69 20.67 15.18 1/2050
G 14 553 2” NPT 232 6.46 32.40 1.89 20.47 21.12 1/3050
G 17 853 2” NPT 232 6.46 42.24 1.89 30.31 39.38 1/3075
G 18 1142 2 1/2” NPT 232 9.84 41.42 2.91 24.02 44.00 1/5060
G 183 1325 3” NPT 232 9.84 41.42 2.91 24.02 44.00 1/5060
G 19 1412 3” NPT 232 9.84 47.32 2.91 29.92 60.50 1/5075
Pre-filter element V – 0.29 psi (dry) – 1.02 psi (saturated) – 99.99% (3μ)
General Purpose Filter ZP – 0.44 psi (dry) – 1.45 psi (saturated) – 99.9999% (1μ) – ≤ 0.5 ppm (14.5 psi and 68˚F)
Oil Removal Filter XP – 0.87 psi (dry) – 2.18 psi (saturated) – 99.99999% (0.01μ) – ≤ 0.01 ppm (14.5 psi and 68˚F)
Super Fine Filter XP4 – 1.74 psi (dry) – 4.06 psi (saturated) – ≥ 99.99999% (0.01μ) – ≤ 0.001 ppm (14.5 psi and 68˚F)
Activated Carbon Filter A – 0.44 psi - ≤ 0.003 ppm (14.5 psi and 68˚F) with an inlet concentration of ≤ 0.01 ppm
Activated Carbon Cartridge KTA – Depending on size 2.18 - 5.8 psi – psi (Oil Removal as A grade)
Conversion factor f for other operating pressures*2
Operating pressure psi 14.5 29.0 45.5 58.0 72.5 87.0 101.5 116.0 130.5 145.0 159.5 174.0 188.5 203.0 217.6 232.1
f= 0.25 0.38 0.50 0.63 0.75 0.88 1.00 1.13 1.25 1.38 1.50 1.63 1.75 1.88 2.00 2.13
*2 calculated for constant velocity and 68°F
Example 1: If you have a flow of 765 scfm (14.5 psi and 68˚F) – ) at a minimum working pressure of 145 psi,
what size filter do you require? Answer: Flow ÷ f = 765 scfm ÷ 1.38 = 553 scfm => G14 size
Example 2: What is the nominal flow through a G14 filter with a minimum working pressure of 145 psi?
Answer: Flow: · f = 553 scfm · 1.38 = 765 scfm (14.5 psi and 68˚F)
Microfilter Housing Construction ZANDER
Microfilter
filter hous-
Microfilter Modular Concept ZANDER
ings combinations
Connections Standard
1/4” - 3” NPT
Filter element
General
Pre-filter
TF 99.99% purpose filter
99.9999%
2” - 12” Flg (3 μm) (1 μm)
≤ 0.5 ppm
Combination kits
Activated Activated
carbon carbon cartridge
(For G3-G13
housings only)
≤ 0.003 ppm ≤ 0.003 ppm
Standard combination kits
(up to G13 size only)
Condensate drains
Comb. Kit
Filter size
Element
Drain
Examples
G 7 ZP Filter with 1/2” NPT thread connection, plug in head and automatic condensate drain
(Standard on V–XP4)
G 11 XP D LS Filter with 1” NPT thread connection, oil removal element, differential pressure gauge and electronic
"zero air loss” condensate drain LS range.
G 14 A W 2” NPT connection with activated carbon filter, plug in head, manual drain (Standard for A & KTA filter).
Wall brackets
Microfilter – Compressed air, gas
and vacuum filters
Compressed air filters are now product development is lead by Dust, dirt and oil mist filtration is
recognized as being an integral strong partnerships with common enough today. ZANDER
part of any system. Few, if any, compressed air and gas users to emphasizes not only the filtration
compressed air systems can ensure the best available product efficiency but links this to energy
operate successfully without high for increasingly demanding costs in terms of pressure
efficiency filters. Production and applications. differential, product consistency
process standards demand the and reliability.
finest quality air and components
are now manufactured to such
tight tolerances that no
contamination is permitted.
Z A N D E R Filter Housings
ZANDER supplies Microfilters in three housing formats:
wa
rrant
All three types of housings are powder coating and the steel 10 year guarantee on the filter
built to the highest quality housings with intensive cleaning, housings. This gives confidence to
standards and have a double priming and acrylic paint. Thanks the user!
surface protection. The aluminum to the attention to quality surface
housings with alochrom and epoxy treatment, ZANDER offers a
A division of Parker Hannifin Corporation © 2008 Parker-Hannifin Corporation
Publication Reference: Microfilter USA 11/08 Rev. 002
Parker Hannifin
ZANDER division
North Carolina, USA
Tel: (678) 924-1000
Toll Free: 1-800-543-0851
Fax: (678) 924-1111
www.zanderusa.com
Parker-Hannifin Corporation, ZANDER division has a continuous policy of product development and although the Company reserves the right to change specifications, it attempts to keep customers informed
of any alterations. This publication is for general information only and customers are requested to contact your ZANDER sales representative for detailed information and advice on a products suitability for