Dimensions

Pre- filter, General purpose filter and Superfine filter Grades VD (E), ZPD(E), XPD(E) and XP4(E)
V, ZP, XP, XP4 Complete with automatic drain and differential pressure gauge
Standard format with automatic condensate drain (E with volt-free contact)

T T T T

Activated carbon filter A & KTA Activated carbon filter AOP & KTAOP
Standard format with manual drain Compete with manual drain and oil indicator

T T T T

Dimensions with electronic condensate drains


LS range LC range
~190
~190

~190
~190

~190

~190
~195

~290

T T T T T T T T
Microfilter
Technical Data

Max. pressure

Filter element
Dimensions
Connection
Capacity*1
nominal

Weight
ZANDER (inches) (inches) (inches) (inches) Qty/
Type scfm NPT/Flg psi A B C D lbs Type
G 2 18 1/4” NPT 232 2.36 6.57 0.06 2.36 1.76 1/1030
G 3 29 1/4” NPT 232 3.43 8.23 0.83 2.95 3.30 1/1050
G 5 41 3/8” NPT 232 3.43 8.23 0.83 3.54 3.30 1/1070
G 6 50 1/2” NPT 232 3.43 8.23 0.83 3.54 3.30 1/1070
G 7 59 1/2” NPT 232 3.43 10.98 0.83 6.30 3.74 1/1140
G 9 106 3/4” NPT 232 5.12 12.40 1.69 5.31 9.46 1/2010
G 10 135 1” NPT 232 5.12 12.40 1.69 5.31 9.46 1/2010
G 11 177 1” NPT 232 5.12 16.34 1.69 9.25 11.00 1/2020
G 12 277 1 1/2” NPT 232 5.12 20.28 1.69 13.19 12.10 1/2030
G 13 412 1 1/2” NPT 232 5.12 28.15 1.69 20.67 15.18 1/2050
G 14 553 2” NPT 232 6.46 32.40 1.89 20.47 21.12 1/3050
G 17 853 2” NPT 232 6.46 42.24 1.89 30.31 39.38 1/3075
G 18 1142 2 1/2” NPT 232 9.84 41.42 2.91 24.02 44.00 1/5060
G 183 1325 3” NPT 232 9.84 41.42 2.91 24.02 44.00 1/5060
G 19 1412 3” NPT 232 9.84 47.32 2.91 29.92 60.50 1/5075

TF 17 853 2” Flg 260 16.0 48.0 8.0 30.0 115.0 1/3075


TF 19 1410 3” Flg 260 17.9 54.0 12.0 30.0 140.0 1/5075
TF 20 1700 4” Flg 260 21.1 55.9 13.0 30.0 330.0 2/3075
TF 30 2560 4” Flg 260 21.1 55.9 13.0 30.0 330.0 3/3075
TF 40 3413 6” Flg 260 23.8 56.6 14.4 30.0 360.0 4/3075
TF 50 4265 6” Flg 260 27.5 59.9 18.0 30.0 400.0 5/3075
TF 60 5120 6” Flg 260 27.5 59.9 18.0 30.0 450.0 6/3075
TF 80 6827 8” Flg 260 28.8 66.0 19.0 30.0 600.0 8/3075
TF 100 8533 8” Flg 260 33.0 65.0 15.0 30.0 500.0 10/3075
TF 120 10240 10” Flg 260 37.0 72.0 18.0 30.0 625.0 12/3075
TF 160 13650 10” Flg 260 37.0 72.0 18.0 30.0 640.0 16/3075
TF 200 17065 12” Flg 260 37.0 72.0 18.0 30.0 875.0 20/3075
* Calculated at 14.5 psi and 68˚F at 100 psig working pressure
1

Filter Element Performance Tables

Pre-filter element V – 0.29 psi (dry) – 1.02 psi (saturated) – 99.99% (3μ)
General Purpose Filter ZP – 0.44 psi (dry) – 1.45 psi (saturated) – 99.9999% (1μ) – ≤ 0.5 ppm (14.5 psi and 68˚F)
Oil Removal Filter XP – 0.87 psi (dry) – 2.18 psi (saturated) – 99.99999% (0.01μ) – ≤ 0.01 ppm (14.5 psi and 68˚F)
Super Fine Filter XP4 – 1.74 psi (dry) – 4.06 psi (saturated) – ≥ 99.99999% (0.01μ) – ≤ 0.001 ppm (14.5 psi and 68˚F)
Activated Carbon Filter A – 0.44 psi - ≤ 0.003 ppm (14.5 psi and 68˚F) with an inlet concentration of ≤ 0.01 ppm
Activated Carbon Cartridge KTA – Depending on size 2.18 - 5.8 psi – psi (Oil Removal as A grade)
Conversion factor f for other operating pressures*2

Operating pressure psi 14.5 29.0 45.5 58.0 72.5 87.0 101.5 116.0 130.5 145.0 159.5 174.0 188.5 203.0 217.6 232.1
f= 0.25 0.38 0.50 0.63 0.75 0.88 1.00 1.13 1.25 1.38 1.50 1.63 1.75 1.88 2.00 2.13
*2 calculated for constant velocity and 68°F

Example 1: If you have a flow of 765 scfm (14.5 psi and 68˚F) – ) at a minimum working pressure of 145 psi,
what size filter do you require? Answer: Flow ÷ f = 765 scfm ÷ 1.38 = 553 scfm => G14 size
Example 2: What is the nominal flow through a G14 filter with a minimum working pressure of 145 psi?
Answer: Flow: · f = 553 scfm · 1.38 = 765 scfm (14.5 psi and 68˚F)
Microfilter Housing Construction ZANDER
Microfilter

All ZANDER Microfilter housings housings, which can weigh up to a


are two piece. This means ton, have a hinged lower
that, no matter what the cover, which one person 2 piece
housing
size is, one person can can open and close,
change the filter when it is time to
elements. change the elements.
Other
The TF flanged filter types of
housing
lb. 3 piece housing
with retaining ring

Microfilter Tie Rod ZANDER element


secured with
tie rod
The tie rod support of the element Equally, the tie rod makes the
to the housing ensures that the element easier to change. There is
element sits in the housing no risk of the element end cap
without any possibility of corroding. This does occur in
movement and therefore leakage competitive filters with aluminum
between the dirty and clean threads on the element
side. corroding into the housing.
The lower end cap of the This means an expensive
element is firmly secured new replacement housing
to the tie rod. This instead of a simple Another
eliminates any possibility of element replacement. method
the end cap separating under A small difference with large
severe shock conditions. cost savings!

filter hous-
Microfilter Modular Concept ZANDER
ings combinations

The user can install simply and consequential pressure drop.


economically ZANDER These filter combinations can be
Microfilters in modular units up easily wall mounted with
to the G13 size. Using a filter brackets.
combination kit, the
installer can link together
up to three filters in a
set. This lowers the
Other types of
housing linked
with pipe or
nipples
Microfilter Construction
and user selection chart Filter head accessories
(Available from G3 size)

Connections Standard

Screwed plugs Pressure


differential gauge

1/4” - 3” NPT

Filter element

General
Pre-filter
TF 99.99% purpose filter
99.9999%
2” - 12” Flg (3 μm) (1 μm)
≤ 0.5 ppm

Combination kits

Activated Activated
carbon carbon cartridge
(For G3-G13
housings only)
≤ 0.003 ppm ≤ 0.003 ppm
Standard combination kits
(up to G13 size only)

Condensate drains

Combination kits and Automatic


condensate drain Manual drain
wall brackets G2 - G13 Standard on V-XP4 Standard on
No need to specify! A-KTA
No need to specify!
Head accessory
Connection

Comb. Kit
Filter size

Element

Drain

Examples

G 7 ZP Filter with 1/2” NPT thread connection, plug in head and automatic condensate drain
(Standard on V–XP4)
G 11 XP D LS Filter with 1” NPT thread connection, oil removal element, differential pressure gauge and electronic
"zero air loss” condensate drain LS range.
G 14 A W 2” NPT connection with activated carbon filter, plug in head, manual drain (Standard for A & KTA filter).
Wall brackets
Microfilter – Compressed air, gas
and vacuum filters
Compressed air filters are now product development is lead by Dust, dirt and oil mist filtration is
recognized as being an integral strong partnerships with common enough today. ZANDER
part of any system. Few, if any, compressed air and gas users to emphasizes not only the filtration
compressed air systems can ensure the best available product efficiency but links this to energy
operate successfully without high for increasingly demanding costs in terms of pressure
efficiency filters. Production and applications. differential, product consistency
process standards demand the and reliability.
finest quality air and components
are now manufactured to such
tight tolerances that no
contamination is permitted.

ZANDER is one of the leaders in


the purification of compressed air,
gas and vacuum flows. Their

Z A N D E R Filter Housings
ZANDER supplies Microfilters in three housing formats:

G-Housings with threaded TF In-line Flanged & ZF Floor-


connection from 1/4” to 3” NPT mounted Flanged housings
years Li
2” to 12” ANSI Flange
fe t e
10

- High grade aluminum casting


im

- Alochromed in and outside to - Welded mild steel vessels


y

wa
rrant

prevent corrosion - Sand blasted, cleaned and de-


- Powder coated to ensure top greased
quality finish - Polyester primed in and outside Untreated and Alochromed filter bowls
- Acrylic paint outside after a salt spray test to
DIN 50021 SS > 250 hours

All three types of housings are powder coating and the steel 10 year guarantee on the filter
built to the highest quality housings with intensive cleaning, housings. This gives confidence to
standards and have a double priming and acrylic paint. Thanks the user!
surface protection. The aluminum to the attention to quality surface
housings with alochrom and epoxy treatment, ZANDER offers a
A division of Parker Hannifin Corporation © 2008 Parker-Hannifin Corporation
Publication Reference: Microfilter USA 11/08 Rev. 002
Parker Hannifin
ZANDER division
North Carolina, USA
Tel: (678) 924-1000
Toll Free: 1-800-543-0851
Fax: (678) 924-1111

www.zanderusa.com
Parker-Hannifin Corporation, ZANDER division has a continuous policy of product development and although the Company reserves the right to change specifications, it attempts to keep customers informed
of any alterations. This publication is for general information only and customers are requested to contact your ZANDER sales representative for detailed information and advice on a products suitability for
specific applications. All products are sold subject to the Company’s standard conditions of sale.

You might also like