DFML 67197-1-1-en-US-1311 Juntas Inflables
DFML 67197-1-1-en-US-1311 Juntas Inflables
tions
DFML-8000, DFML-10000 (-Ex)
DFML-67197-1-1-en_US-1311
Original Operating instructions
Copyright
All rights reserved.
Any duplication of these Operating instructions in any manner, either in whole or in
part, is not allowed without express permission from Bühler AG.
Technical progress
Bühler AG reserves the right to make modifications due to technical progress up to
the time of delivery.
Table of contents
2 Safety....................................................................................................................... 6
2.1 Designated use ........................................................................................................ 6
2.2 Technical condition ................................................................................................... 6
2.3 ATEX ID.................................................................................................................... 6
2.4 Personnel qualification ............................................................................................. 6
2.5 Protection against unexpected start-up .................................................................... 6
2.6 Protective devices .................................................................................................... 7
2.7 Safety signs.............................................................................................................. 7
2.8 Safe work environment............................................................................................. 7
2.8.1 Slipping and stumbling hazard .................................................................... 7
2.8.2 Aspiration .................................................................................................... 7
4 Conversion.............................................................................................................. 9
4.1 Preparing the installation location............................................................................. 9
4.2 Converting the mechanics........................................................................................ 9
4.3 Converting the pneumatics..................................................................................... 12
4.4 Converting the electrical system ............................................................................ 14
5 Decommissioning ................................................................................................ 16
5.1 Removing ............................................................................................................... 16
5.2 Disposal.................................................................................................................. 16
Bühler AG
Seitendichtung aufblasbar DFML-67197-1-1-en_US-1311
Table of contents 3
1 Important information
1.3 Contact
■ Address questions to the appropriate branch office or subsidiary of the
manufacturer.
■ Have the Operating instructions at hand.
Bühler AG
Customer Service Grain Processing
CH-9240 Uzwil, Switzerland
Phone: +41 71 955 30 40
Fax: +41 71 955 33 05
[email protected]
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
4 Chapter 1 Important information
1.4 Personnel qualification
1.4.1 Mechanics
Personnel that work on mechanical devices must be technically trained or have
completed training provided by the manufacturer.
1.4.2 Electricians
Personnel that work on electrical devices must be technically trained or have
completed training provided by the manufacturer.
1.4.3 Welders
Personnel that carry out welding work on equipment must be technically trained.
DANGER
Type and source of danger.
Danger will result in death or serious injury.
Actions for protecting against danger.
WARNING
Type and source of danger.
Danger can result in death or serious injury.
Actions for protecting against danger.
CAUTION
Type and source of danger.
Danger can result in injury.
Actions for protecting against danger.
NOTICE
Type and source of danger.
Danger can result in property damage.
Actions for protecting against property damage.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 1 Important information 5
2 Safety
2.3 ATEX ID
The ATEX ID indicates the conditions required for integrating the machine into an
Ex zone or connecting the machine to an Ex zone.
If the machine starts unexpectedly, people who are working at the machine can be
seriously injured.
■ Set the safety switch to "0" and lock it.
■ Remove the key and keep it with you.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
6 Chapter 2 Safety
2.6 Protective devices
If protective devices are ineffective, this poses a danger to people.
■ Before operating the machine, always verify that all protective devices are
effective.
■ Always keep walkways, grips, steps, railings, platforms and ladders free of
grease, oil, and other dirt.
■ Never climb or walk on the machine and do not use it for storage. Use the
provided steps and platforms only.
■ Wear non-skid safety shoes.
2.8.2 Aspiration
Gases and dust are health hazards and can lead to dangerous situations when the
machine is in operation.
■ Always leave ventilation units running when the machine is in operation and do
not remove them.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 2 Safety 7
3 Parts needed
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
8 Chapter 3 Parts needed
4 Conversion
Fig. 4.1
Fig. 4.2
4. Install a new seal with filler plate. Lay the filler plate (5) with the beveled
edge (A) on the seal holder (6).
IMPORTANT
Do not damage the plug of the sealing profile (B).
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 4 Conversion 9
Fig. 4.3
IMPORTANT
Inspect the seals without using compressed air.
Fig. 4.4
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
10 Chapter 4 Conversion
IMPORTANT
Do not drill the sealing profile.
8. Drill the sealing profile at the designated spot (C) using a ø3 mm drill.
Fig. 4.5
9. Screw in the separation union (8) through the aluminum profile until it is
centered in the sealing profile.
Fig. 4.6
10. Seal: Pull the silicon hose D 16 over the separation union and pneumatic hose
and insert it in the stand through the ø14 mm through-hole.
11. Use a sealing compound to seal the cover plate facing the stand and seal
holder.
12. Screw the cover plate into place.
13. Install the covers of the consoles and close the gate.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 4 Conversion 11
4.3 Converting the pneumatics
1. Connect the separation connections of the seals using a pneumatic hose D6
(L = 20 cm).
2. Connect the other end of the pneumatic hose D6 to the pneumatic hose D10
using a reducer and a plug-in connector.
3. Disconnect the pneumatic hose at the locking cylinder (close position) and
install a T-piece.
4. Attach the GOK pressure regulator to D10 with 2 screw-in connectors G¼".
5. Install a T-piece at the connection to the pressure regulator.
□ On one side of the T-piece, install the pressure switch with angle swivel
union.
□ Install additional T-piece on opposite side.
6. Install roller lever valve (1).
Fig. 4.7
7. At the roller lever valve install a silencer and 2 screw-in connectors G¼“.
Fig. 4.8
8. On the other side, distribute the pneumatic hose D10 on both side seals using a
T-piece.
9. Make sure that the roller lever valve is actuated when the locking cylinder is
closed.
□ Side seals are inflated.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
12 Chapter 4 Conversion
Fig. 4.9 Pneumatics conversion
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 4 Conversion 13
4.4 Converting the electrical system
1. Integrate the pressure controller (D) into the terminal box according to the wiring
diagram.
2. Accept the signal into the installation control system.
Fig. 4.10
Item Description
01 EMERGENCY STOP: Supplied by the customer in accordance
with locally applicable codes and regulations
1 Hinge switch, lock-out device (first access door)
2 Safety switch, safety device for openings (first access door)
1A Hinge switch (second access door)
2A Safety switch, safety device for openings (second access door)
S3 Limit switch, operator’s side gate open
S4 Limit switch, back side gate open
S5 Limit switch, operator’s side gate closed
S6 Limit switch, back side gate closed
S1 Limit switch, interlock system of left side, gates unlocked
S2 Limit switch, interlock system of right side, gates unlocked
S7 Limit switch, interlock system of left side, gates locked
S8 Limit switch, interlock system of right side, gates locked
D Pressure controller, side seal inflatable
Y4 Compressed air supply
Y1a Solenoid valve, opening gates
Y1b Solenoid valve, closing gates
Y2 Solenoid valve, unlocking gates
02 Motor temperature monitor (posistor)
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
14 Chapter 4 Conversion
Fig. 4.11
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 4 Conversion 15
5 Decommissioning
5.1 Removing
When decommissioning the machine (for overhaul, dismantling or disposal
purposes), disassemble it by following the installation steps in reverse order.
■ Before beginning the disassembly work, the person in charge must obtain the
instructions for safe disassembly from the manufacturer.
■ The machine may be disassembled only in observance of all accident
prevention measures and only by trained personnel. These personnel must be
familiar with all relevant safety precautions.
5.2 Disposal
Dispose of the machine and its components in accordance with your locally appli-
cable codes and regulations.
■ Sort and dispose of metal parts by type of metal.
■ Dispose of electric motors properly.
■ Dispose of electronic parts properly.
■ Dispose of plastic pieces properly.
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
16 Chapter 5 Decommissioning
6 Spare parts
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 6 Spare parts 17
6.4 Spare parts lists
6.4.1 DFML-11964-001 Inflatable side seal
Fig. 6.1
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
18 Chapter 6 Spare parts
Bühler AG
Inflatable side seal DFML-67197-1-1-en_US-1311
Chapter 6 Spare parts 19
Bühler AG
CH-9240 Uzwil, Schweiz
Telefon +41 71 955 11 11
Telefax +41 71 955 33 79
www.buhlergroup.com