8.1.1 Description
This unit includes exercises for DriveWindow 2.
8.1.2 Objectives
To learn, how to control the ACS 800 frequency converter with the DriveWindow 2.0.
DriveWindow 2 Overheads
Reset the fault by the DriveWindow. You have to change to local control from
DriveWindow.
7. Fault logger contents. Double click from the Browse Tree Pane (the upper left
hand window) the motor picture and after this the Fault logger picture. The
contents of the fault logger is visible on the upper right hand window.
You can select a large number of items to on-line at the same time by selecting an
area of items with the mouse. Select first an item by mouse, and whilst keeping
the Shift key pressed, select by mouse the last item you would like to measure. All
signals between the first and last item are now selected. Now select the on-line
mode.
Stop the drive.
Note! For safety reasons parameter saving can be done only in Remote control
mode. Save selection is disabled in Local mode (Grayed).
Change to remote. Select File / Parameters / Save As.. Use the file name FIRST
and when comment dialog box appears use the default Date.
Editing of the parameters will happen all the time in the on-line mode with the
selected drive. Whenever you change a parameter it take immediately affect upon the
drive.
8.2.5 Exercises 5 Parameter download from file (PC) into the drive
During the commissioning several of the same kinds of drive it is reasonable to copy
the parameters from one drive to another. Such kinds of operations are made using the
Download-function.
1. First open the parameter-file First.dwp from the menus File / Parameters /
Open.
2. Using the Control Panel CDP 312 change the acceleration time 22.01 = 3s.
3. Select the drive from the Browse Tree Pane where you would like to download
the parameters, by clicking once on the drive with the mouse.
4. Select the File / Parameters / Download.
5. A dialog box appears. Mark only Restore user data and then OK. The download
operation will start.
6. The next dialog box is warning, that there should be the same macro in the file and
the drive before download occurs. Select in this case YES.
7. The last dialog box ask permission to restart the drive. In this case select YES.
8. In a real case you should check the parameter group 99 Start-up data, because
during download operation these are not copied. This is very important during
commissioning and repairing, when a faulty unit is needed to be replaced with a
new one.
9. Check the values of the parameters 22.01 and 22.02. Current settings should be
now a setting from your file (5s).
10. Finally run the motor to check that the drive is working normally.
BACKUP
1. Backup and Restore functions are only possible in Remote control mode. Change
the drive to remote control.
2. Create a new Backup Package (= Folder or Directory). Select File / System
software / New-menu Backup Package.
3. Select the Backup-command from the File / System Software-menus. Select the
drive. Backing up will start and it will take several minutes to complete.
4. Finally give a name to the Backup Packet. Select the Save As..-command from
File / System Software-menus. Now you can also locate the file to your own
directory or diskette. Give a name to the package, e.g. mybackup.BPG
5. Finally select the Close command from File / System Software-menu. Now the
backup of the selected drive is complete - the entire content of the control board
has been copied into the backup-file, also the firmware.
RESTORE
1. Select Open command from the File / System Software-menus. Choose the
correct backup package, e.g. mybackup.BPG (in the dialog box all backups are
shown which have been made from the same DriveWindow-link).
2. Select Restore command from the File / System Software-menu. A dialog box
appears. Now select the correct drive. Then select the Restore-command. From
the dialog box select the correct backup file to be restored. When the last
confirmation Dialog box appears, select YES. Restoring will take several minutes.
3. Test that the drive works normally.
Figure 6. Monitor-window
4. Start the monitor from the Monitor Tool bar; located in the upper part of the
window area.
5. Start the drive. Increase and decrease the speed of the motor. During the
monitoring the monitoring, it can be paused or stopped. When it is stopped the
whole screen of the monitor can be Cleared, or from the File / Graph-menu other
commands can be selected e.g. copy (copy graphics e.g. to Word or clipboard).
Printing is also possible. Export means that graphics are exported in numerical
form to e.g. Excel-program. Saving graphics themselves is also possible (File /
Graph / Save As…).
Figure 8. Monitor/Graph-commands
6. Clear the monitor. Choose the following signals for measurement:
time _________________s
Clicking with the mouse on the graphical area, causes measured value to appear on
the screen. Use, if necessary, Zoom-command from the View-menu.
Export the GRAPH. Select File-menu and then submenu Graph, and finally the
command Export. Use the filename: Mygraphs.txt. Now the graphs are available in
the numerical form in any kind of MS-Window-applications.
3BSF20 0600 R0401 8-9
Course: ACS800 Multidrive
Alternatively it is possible to print out the graphics. Select the File / Graph / Print-
command.
Interval 3 ms
Pre-Trig 300ms
Trig Conditions Fault Level rising edge
Trig Variable Par 1.4 Motor speed
Trig Level 200 (rpm)
Trig Hysteresis 20 (rpm)
X Axis Length (s) 1s If the program suggests some other time, answer YES.
4. Start the logger from the menu Datalogger / Start.
Datalogger Status information changes to Running, Initialized.
5. Set the speed reference to 400 rpm and start the drive.
Status text changes to Filled, Initialized after logger has been triggered.
6. Read the values to the screen with Upload command from the Datalogger menu.
7. Scale by double clicking on the signal names in the Datalogger window and change
the Coefficient value so that the signals suitable fit on the graphical window.
8. Cross from the menu View / Graph Cursor… selections Time and Unscaled.
Time can be seen in the upper part of the cursor line after clicking the graphical
window by the mouse pointer.
Because not scaled values are selected, the numbers on the screen are real values,
not scaled by the coefficient.
9. Measure the signal values at the moment of triggering (time is zero).
1.04 = _____________
1.11 = _____________
1.28 = _____________
1.29 = _____________
10. Save the Datalogger graphical display File / Graph / Save As… and give a name.
Perform also Export- command. Exported file can be edited also by other
Windows programs.
File / Graph / Export and give a name. From the following window select all four
channels, all samples and measured values.