0% found this document useful (0 votes)
39 views

File Information: Drive Information: Torque/Force Foldback Information

This document contains configuration information for a motion control drive, including motor, tuning, and I/O settings. It lists 92 parameters with their values and units.

Uploaded by

prajwal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views

File Information: Drive Information: Torque/Force Foldback Information

This document contains configuration information for a motion control drive, including motor, tuning, and I/O settings. It lists 92 parameters with their values and units.

Uploaded by

prajwal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Configuration Report - Node 0

File Information: 46. RAS™ Jerk Setting: 15 (msec)


47. Anti-Hunt™: OFF
1. File Name: Z1 new.mtr
Torque/Force Foldback Information:
Drive Information:
48. Foldback Torque: 5. (% of max)
2. Model: Teknic SST-1500-UCX-1-1-1 49. Hard Stop Torque Threshold: 80 (% of Torque Limit)
3. Firmware Version: TEK32DA50 1.1.1 0x2EAA 50. Hard Stop Qualify Time: 50. (msec)
4. Online State: Disabled 51. Foldback Relax Time: 100 (msec)
5. Maximum Output Current: 23 (amperes) 52. Hard Stop Foldback: ON
6. Serial Number: 4,920,872 53. Move Done Foldback: OFF
7. Hardware Version: T1 54. Mode Line Foldback: OFF
8. Bus Voltage, Nominal: 75 (volts)
9. EE Update Acknowledge: &H2EAA Monitor Port:
10. Configuration Change Count: 0
55. Tracking Error 200 (quad counts)
11. Step Input Resolution: 819.2 (steps/rev)
56. Filter OFF
12. Direction Polarity: Reversed
13. Command Input Mode: Step+Direction Position Logic Power Backup:
14. High Level Feedback: Move Done
15. Max. Step Input/Encoder Step=1.25 MHz, Encoder=10.0 57. Logic Power Position OFF
Limit: MHz Recovery:
16. Analog Input Filter: ON 58. Recovery Window: 0 (quad counts)
59. Delay to Ready Out: 0 (msec)
Shutdown History: 60. Delay to Servo On: 250 (msec)
* No Shutdowns in the History Safety Setup:
Log *
61. Limit Switch Mode: Position
Motor Information: 62. Tracking Error Limit: 4,000 (quad counts)
63. Torque Limit: 100. (% of max)
17. Motor Type: Rotary Brushless
18. Max. Continuous (RMS) 9. (amperes) Configuration Settings:
Motor Current:
19. Max. Time @ 3x RMS Current 3. (sec) 64. Configuration Register: &H5212C0A9 (bit-field)
Limit: 65. Velocity Estimator: 2
20. Pole Count: 8 66. Step-Input Filter: ON
21. Encoder Density: 8,192 (quad counts/rev) 67. Encoder Filter: ON
22. Ke: 22.00 (Vpeak/kRPM) 68. Vector Torque Loop: ON
23. Comm. Sensor Reference 0 (elec. deg.) 69. Vector Lock: OFF
Offset: 70. Mode Line Action: HS Inh
24. Winding Resistance (phase 1.6 (ohms) 71. Run-time Calibration: ON
to phase): 72. Power-on Calibration: ON
25. Elec. Time Constant: 4.1 (msec) 73. Logic Power Backup Support: YES
26. Encoder Speed Limit: 600,440 (quad counts/sec)
27. Commutation Sensor Polarity: Normal
Miscellaneous:
28. Encoder Bad Sequence ON 74. Move Done Verify Time: 10.1 (msec)
Detect: 75. In-Range Window: 20 (quad counts)
29. Commutation Sensors: Use Upon Reset 76. Analog Offset Adjust: 0. (%)
30. Commutation Sensor Check: ON 77. Torque, Commanded: 0.000 (amperes)
78. Position, Commanded: 0 (quad counts)
Tuning Information: 79. Position, Measured: 0 (quad counts)
31. Kv: 150,000 80. Velocity, Measured: 0 (k quad counts/sec)
32. Kp: 22,000 81. RMS Level: 0 (% to shutdown)
33. Ki: 60
Software Version Information:
34. Kfv: OFF
35. Kfa: 250,000 82. SST Quickset Version:
36. Knv: 3,000 6.4.1 C:\Program Files (x86)\Teknic\Quickset 6.4\quickset64
37. Knv(Anti-hunt): OFF 83. Flash Library Version:
38. Knp: OFF 1.0.55 C:\Program Files (x86)\Teknic\Quickset 6.4\TekFlashLib
39. Kfj: OFF 84. Drive Library Version:
40. Kff: OFF (% of max) 4.2.57 C:\Program Files (x86)\Teknic\Quickset 6.4\TekDrvLib42
41. Kip: 2,500 85. Networking Library Version:
42. Kii: 1,000 2.0.135 C:\Program Files (x86)\Teknic\Quickset 6.4\TekNetLib2
43. Torque Bias: OFF (% of max) 86. Serial Port Library Version:
44. Fuzzy Aperture: 0 (quad counts) 1.0.33 C:\Program Files (x86)\Teknic\Quickset 6.4\TekSerialLib
45. Anti-Hunt Hysteresis: 0 (quad counts)

05/07/2022 12:32:58 Z1 new.mtr Page 1


87. Timer Library Version:
1.0.45 C:\Program Files (x86)\Teknic\Quickset 6.4\TekTimer
88. Value Library Version:
1.0.150 C:\Program Files (x86)\Teknic\Quickset 6.4\ValuesLib
89. Stimulus Helper Version:
1.0.4 C:\Program Files (x86)\Teknic\Quickset
6.4\TekMGutils.DLL
90. Enhanced Text Box Version:
1.0.67 C:\Program Files (x86)\Teknic\Quickset 6.4\nTextBox
91. LED Control Version:
1.0.27 C:\Program Files (x86)\Teknic\Quickset 6.4\LED
92. Parameter Editor Control Version:
1.0.86 C:\Program Files (x86)\Teknic\Quickset 6.4\ParamEditor
93. Radio Group Control Version:
1.0.19 C:\Program Files (x86)\Teknic\Quickset
6.4\ParamRadGrpEditor
94. Scope Control Version:
5.0.3 C:\Program Files (x86)\Teknic\Quickset 6.4\TekGraph.ocx

05/07/2022 12:32:58 Z1 new.mtr Page 2