TABLE OF CONTENT SAFETY PRECAUTION
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a
2. Parts & Accessories .............................................................................. 3 sufficient strength to withstand 4 times the weight of the ceiling fan.
3. Installation Instruction ........................................................................... 4 - 8 The mounting of the suspension system shall be performed by the manufacturer, its service agent or
suitably qualified persons.
4. Transmitter Assembly & Function ......................................................... 8 - 9 The fan is to be installed so that the blades are more than 2.5m above the floor.
5. Power Supply Connection & Circuit Diagram ....................................... 9 - 10 Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing
conductor. The earthing terminal in the fan assembly should be such that should any part of the suspen-
6. Maintenance ......................................................................................... 10 sion system fall off, the body of the fan assembly shall effectively earthed.
7. Technical Specifications ........................................................................ 11 Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
8. Customer Service Centre ...................................................................... 12 Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from
being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF”
SAFETY PRECAUTION position.
If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to
service personnel or the user.
Warning
Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil
Installation and maintenance work shall only be performed by qualified persons, familiar with local code vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or
and regulation, and experienced with this type of appliance. chemical reaction.
All field wiring must be installed in accordance with the national wiring regulation. Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respec-
tively.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring
Don’t use joined and twisted wires for incoming power supply.
work according to the wiring diagram.
Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
The unit must be GROUNDED to prevent possible hazard due to insulation failure.
The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the The fan suspension system and blade screw tightening shall be examined yearly.
suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent electro-
cution. Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its
service agent or suitably qualified persons.
Tighten the blade firmly using a screw driver.
Blades that are detached from the unit during operation will cause serious injuries and property damages. Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that
the blade is fully static before doing any maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the
manufacturer, its service agent or suitably qualified persons.
1 2
PARTS & ACCESSORIES INSTALLATION INSTRUCTION
Downrod
Motor Assembly Canopy Coupling Cover
Rubber
Pulley Clevis Pin
Nut
Coupling Washer
Cover
Bolt
Blade Panel x 5 Blade Holder x 5 Switch Housing Safety
Wire
with Receiver
Step 2
a) Route all the wires from the Motor through
the Downrod.
b) Fix the Downrod to the coupling with Bolt,
Washer, Nut and tighten them firmly then insert
the Clevis Pin.
Fan Blade x 5 Rubber Pulley Assembly Step 4 - Remove the Safety Wire screw and
with Downrod IMPORTANT : Clevis Pin MUST be inserted to spring washer from the Downrod.
prevent Nut from loosening.
Green/
Yellow (E)
Brown (L)
Blue (N)
Bolt, Washer, Nut Blade Panel Screw Blade Holder Screw
and Clevis Pin x 2 & Washer x 16 & Washer x 11 Safety Wire
Battery x 2
AAA Washer & Nut
AAA Clevis Pin
Coupling
3 4
INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION
Step 5 Step 7
Tie the Safety Wire across the hook as shown. Connect the wires from the fan to house’s supply wire.
Yellow/Green (E)
Blue (N)
Safety Wire
Brown (L)
Step 8
Align the 3 holes on the Blade Holder, Blade and Blade Panel and screw on with Blade Panel Screw and
In the case of “J” Hook is being used. Washer provided.
Step 6
Firmly screw the Safety Wire with spring washer onto the Downrod.
Blade Holder
Blade
Blade Panel
5 6
INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION
IMPORTANT : Assemble the Fan Blades only after the ceiling fan is mounted on the hook.
TRANSMITTER ASSEMBLY
Transmitter
Step 10
Connect the connectors and twist the Switch Housing onto the Fitter Plate till snug.
Transmitter Holder
AAA
AAA
Fitter Plate
Switch Housing
7 8
TRANSMITTER FUNCTION CIRCUIT DIAGRAM
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures
are as follows :
1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution.
2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface.
3. Do not bent the blades while cleaning. At the event where blades are bent or damage,
order new set of blades from service center or dealer shop.
4. There is no need to oil the fan.
Regulator Dimmer Switch
9 10
TECHNICAL SPECIFICATIONS CUSTOMER SERVICE CENTRE
Model AX20-5B/56 AX20-5B/42 If you need any technical assistance or faulty report, please contact our customer service centre at :
Ipoh : 11, Laluan Tasek Timur 5, Pusat Perdagangan Tasek Indra, 31400 Ipoh, Perak.
Tel : 05-545 2282 / 547 2282 Fax : 05-547 6282
Penang : 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
Tel : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966
362mm 460mm
Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
(1’ 2”) (1’ 6”)
Tel : 09-516 5226 Fax : 09-513 9226
More than 1m