Vulkan
Vulkan
VULKARDANVULKARDAN-L
E
VULKARDAN-P
Rubber + Silicone
U-JOINT COUPLINGS
VKL/VKP
VULKARDAN-L
VULKARDAN-P
for U-Joint Applications
VULKARDAN-L
VULKARDAN-P
VKL
VKL
Size (#)
(# - See Notes
on Prev Page)
1714
1711
1715
1712
1914
1911
1915
1912
2114
2111
2115
2112
2514
2511
2515
2512
2914
2911
2915
2912
3414
3411
3415
3412
4114
4111
4115
4112
4514
4511
4515
4512
4814
4811
4815
4812
5014
5011
5015
5012
5814
5811
5815
5812
TECHNICAL DATA
Nominal
Torque
[lb-ft ]
TKN (1)
Torque
Max1
[lb-ft]
TKmax1 (2)
Torque
Max2
[lb-ft]
TKmax2 (3)
Vibratory
Torque
[lb-ft ]
TKW (4)
Power
Loss
[KW]
PKV30 (5)
Max
Speed
[RPM ]
N (6)
118
118
148
148
184
184
229
229
295
295
369
369
465
465
590
590
738
738
922
922
1180
1180
1475
1475
1844
1844
2286
2286
2323
2323
2950
2950
2950
2950
3688
3688
3688
3688
4647
4647
7376
7376
9220
9220
177
177
221
221
277
277
343
343
443
443
553
553
697
697
885
885
1106
1106
1383
1383
1770
1770
2213
2213
2766
2766
3430
3430
3485
3485
4425
4425
4425
4425
5532
5532
5532
5532
6970
6970
11063
11063
13829
13829
425
425
531
531
664
664
823
823
1062
1062
1328
1328
1673
1673
2124
2124
2655
2655
3319
3319
4248
4248
5310
5310
6638
6638
8231
8231
8364
8364
10621
10621
10621
10621
13276
13276
13276
13276
16728
16728
26552
26552
33190
33190
44
44
44
44
74
74
74
74
118
118
118
118
184
184
184
184
295
295
295
295
472
472
472
472
738
738
738
738
930
930
930
930
1180
1180
1180
1180
1476
1476
1476
1476
2952
2952
2952
2952
0.170
0.170
0.170
0.170
0.200
0.200
0.200
0.200
0.230
0.230
0.230
0.230
0.260
0.260
0.260
0.260
0.330
0.330
0.330
0.330
0.380
0.380
0.380
0.380
0.480
0.480
0.480
0.480
0.530
0.530
0.530
0.530
0.530
0.530
0.530
0.530
0.650
0.650
0.650
0.650
0.560
0.560
0.560
0.560
6350
6350
6350
6350
5550
5550
5550
5550
4900
4900
4900
4900
4200
4200
4200
4200
3550
3550
3550
3550
3000
3000
3000
3000
2500
2500
2500
2500
2300
2300
2300
2300
2300
2300
2300
2300
2000
2000
2000
2000
1800
1800
1800
1800
Dyn. Torsional
Stiffness
(X106)
[lb-in/rad]
CTdyn (7)
0.006
0.008
0.013
0.018
0.009
0.012
0.021
0.028
0.015
0.019
0.033
0.046
0.023
0.031
0.053
0.073
0.036
0.049
0.083
0.115
0.058
0.078
0.133
0.186
0.089
0.120
0.204
0.283
0.115
0.151
0.257
0.363
0.146
0.195
0.332
0.460
0.177
0.239
0.407
0.566
0.265
0.338
0.549
0.658
Relative
Damping
(8)
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
A torsional vibration analysis, which considers power loss in the VKL rubber element, should be conducted to confirm coupling selection
VKL
1640
D1
D2
D3
VKL
Group
Size
SAE
FW
Size
LKR*
U-Joint
to suit
Nominal
Overall Dimensions
Torque
TkN
D1
D2
D3
L8
lb-ft
118
171x
8
10.374
5.91
3.15
1.73
148
184
191x
8
10.374
6.77
3.74
2.03
229
295
211x
8
10.374
7.68
4.13
2.22
369
465
8
10.374
8.86
4.92
2.50
251x
590
11.5
13.874
8.86
4.92
2.50
738
11.5
13.874
10.59
6.10
3.01
291x
922
14
18.374
10.59
6.10
3.01
1180
11.5
13.874
12.32
7.28
3.45
341x
1475
14
18.374
12.32
7.28
3.45
1844
411x
14
18.374
14.65
9.06
3.90
2286
2323
451x
14
18.374
16.26
10.04
4.41
2950
2950
481x
14
18.374
16.42
8.98
4.69
3688
3688
501x
18
22.500
18.74
11.42
5.14
4647
* Refer to SAE standard J620 for flywheel connection details; a copy is provided on page 11
Dimensions in inches. VKL group size does not specify stiffness.
Weight
lb
Inner
Outer
Inertia
lb-in-sec
Inner
Outer
L7
H5
L9
0.59
0.31
0.39
0.04
0.27
0.75
0.43
0.39
0.09
0.35
0.87
0.55
0.35
10
0.18
0.44
1.10
1.10
0.98
0.98
1.57
1.22
0.79
0.39
0.47
0.39
1.10
0.39
0.31
0.31
0.67
0.67
0.31
0.67
12
12
22
22
32
32
11
18
17
28
23
35
0.27
0.27
0.80
0.80
1.50
1.50
0.44
1.15
1.42
3.27
2.03
4.43
1.36
0.39
0.73
51
29
3.45
4.07
1.61
0.98
0.71
69
42
5.66
6.46
1.81
1.26
0.71
71
56
5.31
8.23
2.09
1.34
0.79
113
89
11.95
19.03
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKL
1660/1670
21 Flywheel
L3
L1
L2
L1
L2
L4
L3
L4
L3
D1
D2
D3
U-Joint
to suit
LKR*
LKR*
D2
D1
U-Joint
to suit
D1
D2
U-Joint
to suit
LKR*
Series 1670
Series 1660
Series 1660
5810 Group only
L3
18 Flywheel
L2
L1
VKL
Group
Size
SAE
FW
Size
Nominal
Overall Dimensions
Weight
Inertia
Torque
lb
lb-in-sec
TkN
D1
D2
D3
L1
L2
L3
L4
Inner
Outer
Inner
Outer
lb-ft
118
171x
8
10.374
5.91
3.15
1.73
1.06
0.31
0.39
4
6
0.04
0.27
148
184
191x
8
10.374
6.77
3.74
2.03
1.30
0.43
0.39
6
9
0.09
0.35
229
295
211x
8
10.374
7.68
4.13
2.27
1.56
0.55
0.35
9
10
0.18
0.44
369
8
10.374
8.86
4.92
2.50
1.81
0.79
0.31
12
11
0.27
0.44
465
251x
590
11.5
13.874
8.86
4.92
2.50
1.81
0.39
0.31
12
18
0.27
1.15
11.5
13.874
10.59
6.10
3.01
1.91
0.47
0.67
22
17
0.80
1.42
738
291x
922
14
18.374
10.59
6.10
3.01
1.91
0.39
0.67
22
28
0.80
3.27
11.5
13.874
12.32
7.28
3.45
2.66
1.10
0.31
32
23
1.50
2.03
1180
341x
1475
14
18.374
12.32
7.28
3.45
2.30
0.39
0.67
32
35
1.50
4.43
1844
411x
14
18.374
14.65
9.06
3.90
2.64
0.39
0.73
51
29
3.45
4.07
2286
2323
451x
14
18.374
16.26
10.04
4.41
3.11
0.98
0.71
69
42
5.66
6.46
2950
2950
481x
14
18.374
16.42
8.98
4.69
3.23
1.26
0.71
71
56
5.31
8.23
3688
3688
501x
18
22.500
18.74
11.42
5.14
3.60
1.34
0.79
113
89
11.95
19.03
4647
7380
18
22.500
22.83
12.60
8.35
7.40
7.01
112
255
14.43
64.52
581x
9220
26.500
22.83
12.60
9.06
8.23
1.02
112
356
14.43 100.18
21
Dimensions in inches. VKL group size does not specify stiffness.
* Refer to SAE standard J620 for flywheel connection details; a copy is provided on page 11
Series 1660 is available in all sizes listed. Series 1670 with companion flange is available in all sizes up to 5010; Series 1670 with Mechanics style yoke is available in size
1910 up to size 4510. Weights and inertias are without companion flange or yoke.
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKL
1680
SHAFT TO U-JOINT
L1
L2
D2
Flange or Yoke
to suit*
D3
D1
Hub
to suit*
Series 1680
Overall dimensions
Nominal
Torque
TkN
D1
D2
D3
lb-ft
118
7.165
5.91
3.15
171x
147
184
8.031
6.77
3.74
191x
229
295
211x
9.213
7.68
4.13
369
465
251x
10.630
8.86
4.92
590
738
291x
12.362
10.59
6.10
923
1181
341x
14.173
12.32
7.28
1476
1845
411x
16.535
14.65
9.06
2288
2325
451x
18.701
16.26
10.04
2952
2952
481x
18.701
16.42
8.98
3690
3690
501x
22.835
18.74
11.42
4649
Dimensions in inches. VKL group size does not specify stiffness.
*Weights and inertias are without companion flange, hub or yoke.
VKL
Group
Size
Weight
lb
Inertia
lb-in-sec
L1
L2
Inner
Outer
Inner
Outer
2.09
1.71
10
0.09
0.18
2.44
2.07
10
0.09
0.27
2.72
2.34
14
0.18
0.53
3.07
2.68
13
23
0.27
1.06
3.66
3.21
22
31
0.80
2.04
4.17
3.68
32
46
1.50
3.89
4.72
4.17
51
60
3.45
6.64
5.31
4.72
69
96
5.66
14.07
5.51
4.76
71
109
5.31
15.49
6.18
5.41
111
178
12.04
36.55
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKL
1690
SHAFT TO U-JOINT
L1
L2
D1
U-Joint
to suit
L3
D3
D2
VKL
Group
Size
Nominal
Hub Details
Torque
TkN
Max Bore
L3
D3
lb-ft
118
171x
1.250
1.77
1.65
147
184
191x
1.375
2.24
2.05
229
295
211x
1.625
2.64
2.44
369
465
251x
2.000
3.23
3.07
590
738
291x
2.750
4.41
4.13
923
1181
341x
3.250
5.00
4.96
1476
1845
411x
4.250
6.30
6.30
2288
2325
451x
4.500
6.85
6.90
2952
2952
481x
4.250
6.30
6.30
3690
3690
501x
5.000
7.60
7.72
4649
All dimensions in inches. VKL group size does not specify stiffness
Overall Dimensions
Weight
lb
D1
D2
L1
L2
7.165
5.91
3.19
8.031
6.77
9.213
Inertia
lb-in-sec
Inner
Outer
Inner
Outer
2.08
10
0.09
0.18
3.94
2.44
10
0.09
0.27
7.68
4.41
2.72
13
14
0.18
0.53
10.630
8.86
5.32
3.07
20
23
0.27
2.04
12.362
10.59
6.81
3.66
40
31
0.89
3.89
14.173
12.32
7.72
4.17
61
46
1.86
3.72
16.535
14.65
9.39
4.72
108
60
4.43
6.64
18.701
16.26
10.32
5.31
145
96
7.26
14.07
18.701
16.42
9.84
5.51
129
109
6.28
15.49
22.835
18.74
11.77
6.18
217
178
14.96
36.55
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKL
1690/TL
SHAFT TO U-JOINT
Hubs machined for Taper-Lock bushings
L1
D1
U-Joint
to suit
D2
VKL
Group
Size
Nominal
Torque
TkN
lb-ft
Taper-Lock
Bushing
Size
Max Bore
Weight
lb
Overall Dimensions
D1
295
211x
2525
2.50
9.213
369
465
251x
3030
3.00
10.630
590
738
291x
3535
3.50
12.362
922
1180
341x
3535
3.50
14.173
1475
1844
411x
4040
4.00
16.535
2286
All dimensions in inches. VKL group size does not specify stiffness
SeeTaper-lock Mounting Instructions on page 11.
Inertia
lb-in-sec
D2
L1
Inner
Outer
Inner
Outer
7.68
3.13
14
0.18
0.53
8.86
4.06
13
23
0.27
1.06
10.59
4.56
22
31
0.80
2.04
12.32
4.60
32
46
1.50
3.89
14.65
5.00
51
60
3.45
6.64
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKP
VKP
Size (#)
(# - See
Notes
Below)
0512
0522
0612
0622
0712
0722
0732
0812
0822
1012
1022
1212
1222
1232
1411
1422
1712
1722
2012
2022
2032
1.
2.
3.
4.
5.
TECHNICAL DATA
Nominal
Torque
[lb-ft]
TKN (1)
Torque
Max
[lb-ft]
TKmax
236
280
369
465
590
738
922
1180
1475
1844
2323
2950
3688
4610
5900
7376
9220
11653
14751
18439
23233
708
841
1106
1394
1770
2213
2766
3540
4425
5532
6970
8851
11063
13829
17701
22127
27659
34960
44254
55317
69700
Vibratory
Torque
[lb-ft]
TKW (4)
96
111
148
185
236
295
369
472
590
738
923
1181
1476
1845
2362
2952
3688
4661
5900
7376
9293
Power
Loss
[KW]
PKV30 (4)
Max
Speed
[RPM]
N (2)
0.10 TkN
0.25 TkN
0.50 TkN
0.75 TkN
1.00 TkN
0.020
0.020
0.030
0.030
0.070
0.070
0.070
0.100
0.100
0.180
0.180
0.300
0.300
0.300
0.510
0.510
0.820
0.820
1.510
1.510
1.510
4100
4100
3100
3100
3100
3100
3100
3100
3100
2540
2540
2100
2100
2100
1950
1950
1650
1650
1650
1650
1650
0.011
0.011
0.019
0.020
0.028
0.032
0.034
0.057
0.067
0.100
0.097
0.147
0.152
0.173
0.266
0.236
0.358
0.434
0.757
0.947
0.969
0.014
0.015
0.024
0.026
0.035
0.043
0.050
0.065
0.085
0.120
0.122
0.185
0.200
0.232
0.333
0.633
0.487
0.611
0.934
1.075
1.159
0.022
0.025
0.036
0.043
0.056
0.071
0.087
0.100
0.145
0.179
0.197
0.272
0.329
0.407
0.549
0.339
0.823
1.089
1.434
1.580
2.045
0.032
0.038
0.054
0.068
0.085
0.109
0.139
0.149
0.220
0.266
0.316
0.398
0.504
0.646
0.845
1.058
1.257
1.708
2.182
2.487
3.456
0.045
0.053
0.080
0.094
0.119
0.154
0.192
0.208
0.319
0.367
0.447
0.553
0.726
0.907
1.181
1.549
1.757
2.376
3.173
3.708
5.178
When selecting coupling, the permanent output of the engine is to be used as a basis. See page 2 for explanation and calculations of
Technical Data.
The listed permissible speed is based on the maximum flange diameter of the respective coupling size. If a different flange diameter is
used, the permissible speed must be corrected accordingly.
The stated values refer to the dynamic torsional stiffness at f= 10 Hz and t = 86F. Specific torsional stiffness must be calculated from
formula: CTdyn = CTdyn 0.95 + (0.005 f )
At ambient temperatures higher than 140F, a control calculation should be made using CTdyn140F = 0.75 CTdyn. The allowable vibratory
torque, TKW, and the allowable power loss, PKV, are then reduced by the factor S t = 0.6.
Due to the physical characteristics of the elastic elements. Tolerances are possible in the mentioned values.
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKP
1630
FLYWHEEL TO U-JOINT
L1
L2
L3
D2
PD*
D1
D3
LKR*
VKP group size does not specify stiffness (e.g. VKP group 0802 includes 0812 and 0822)
VKP
Group
Size
Nominal
Torque
TkN
lb-ft
SAE
FW
Size*
8
10
11.5
8
10
11.5
11.5
14
0502
236
280
0602
369
465
0702
590
922
0802
1180
1475
1002
1844
2323
1202
2950
4610
1402
5900
7376
1702
9220
11653
2002
14751
23233
14
14
16
18
18
21
21
24
24
Overall dimensions
Weight
lb
D1
D2
D3
L1
L2
L3
Inner
7.99
8.43
4.72
2.56
0.35
0.31
9.13
9.65
5.91
2.95
0.39
0.35
12
10.71
11.26
7.09
3.62
0.47
0.31
20
13.11
13.70
8.86
4.33
0.51
0.39
35
15.16
15.91
9.84
5.12
0.59
0.55
54
17.56
18.43
11.22
5.79
0.63
0.71
91
20.47
21.26
12.40
6.93
0.87
0.87
130
24.21
25.28
14.09
7.48
0.87
0.94
225
28.35
29.69
16.54
9.25
0.98
0.87
357
Inertia
lb-in-sec
Outer
17
21
24
26
30
42
43
56
77
107
118
129
167
194
287
312
410
476
627
Inner
0.08
0.18
0.38
1.16
2.19
4.89
9.03
21.33
43.55
Outer
0.55
0.81
1.17
1.15
1.56
3.70
2.39
5.04
7.28
10.94
13.37
16.92
23.64
34.43
56.20
68.77
103.20
145.86
220.38
*Refer to SAE standard J620 for flywheel connection details on page 11. All dimensions in inches
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VKL/VKP
CONNECTION DATA
Standard SAE
J620D
Flywheel
#4
Tapped holes
H
LKR
PD
T
No. of
Holes
S
Bolt Size
0.50
9.625
10.375
3/8-16
#3
10
0.62
11.625
12.375
3/8-16
#2
11.5
1.12
13.125
13.875
3/8-16
#1
14
1.12
17.250
18.375
1/2-13
#1/2
16
1.12
19.250
20.375
1/2-13
#0
18
1.25
21.375
22.500
5/8-11
#00
21
1.25
25.250
26.500
12
5/8-11
H
PD
LKR
2)
Insert bushing into element hub. Match the hole pattern, not
threaded holes. Each complete hole will be threaded on one
side only.
3)
LIGHTLY oil the set or cap screws and thread into those half threaded holes
indicated by O in figure 1. Do not lubricate the bushing taper, bushing bore, hub
taper or shaft. Doing so could result in breakage of the product.
4)
Position the assembly onto the shaft. The bushing should be flush with the end of
the shaft.
5)
Alternately torque the set or cap screws to recommended torque setting in chart
below.
211x
251x
291x
2525
3030
3535
1/2 x 1
5/8 x 1-1/4
1/2 x 1-1/2
36
67
84
1/4
5/16
3/8
Nos. 3535 / 4040 have socket head cap screws.
341x
3535
1/2 x 1-1/2
84
3/8
411x
4040
5/8 x 1-3/4
142
1/2
American VULKAN reserves the right to change or otherwise modify the values on this page; certified prints are available.
Occupational safety and health administration standard 1910.219 requires guards, casings, covers, or other protective devices for mechanical power transmission apparatus.
VULKAN
FLEXIBLE COUPLINGS
VULKARDAN-E
VULKARDAN-E
Free-standing
TORFLEX
VULASTIK-L
MEGIFLEX-B
VULKARDAN-L
VULKARDAN-P
Highly flexible VULKAN couplings for use with universal and CV joint shafts.
VULKARDAN-L
Coupling with linear torsional stiffness.
Torque range: 118 9220 lb-ft
VULKARDAN-P
Coupling with progressive torsional stiffness.
Torque range: 236 23,234 lb-ft