02 RDU Overview

The document provides an overview of RDU monitoring products, including the RDU-A G2, RDU-SIC G2, and RDU-EX. The RDU-A G2 can monitor up to 32 devices through its RS485 ports, extension cards, or SNMP. The RDU-SIC G2 is a monitoring card that can connect to UPS devices, PDUs, air conditioners, sensors, and more. The RDU-EX is a small, rack-mounted monitoring device with an independent power supply.

Uploaded by

Oak Soe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
127 views

02 RDU Overview

The document provides an overview of RDU monitoring products, including the RDU-A G2, RDU-SIC G2, and RDU-EX. The RDU-A G2 can monitor up to 32 devices through its RS485 ports, extension cards, or SNMP. The RDU-SIC G2 is a monitoring card that can connect to UPS devices, PDUs, air conditioners, sensors, and more. The RDU-EX is a small, rack-mounted monitoring device with an independent power supply.

Uploaded by

Oak Soe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

RDU Overview

CS R&D Dept.
Ryan Zhou
[email protected]
目录
RDU Products Overview

RDU-A G2 Introduction

RDU-SIC G2 Introduction

RDU-EX Introduction

FAQ

All rights reserved 版权所有,仿冒必究


Company Confidential 公司机密,不得公开
RDU Products
Overview
Converged System Product Line
Solution
Smart

SmartCabinet SmartRow SmartAisle SmartMod


Rack

E Series F Series Coolflex CoolTherm Accessories


Monitoring

RDU-M RDU-A G2 RDU-EX RDU-C

RDU-SIC G2 IRM-Sensors
PDU

PDU (Basic) MPS PDU MPI PDU MPH2 PDU


Other

Access Control IP Camera Power Meter Sensors

Avocent Core
RDU Monitoring System
RDU Products Appearance

RDU-A G2

RDU-EX
RDU-M

IRM-TH Sensor
All rights reserved 版权所有,仿冒必究
RDU-SIC G2
Company Confidential 公司机密,不得公开
RDU-A G2
RDU-A G2
2×USB Modem/Camera 2 × Smoke
2 × DI SMS Modem 2 × Card Slot: 4COM/8DIAI/8DOAO
Console
2 ×Power Indicator 2×10/100M LAN 2 × Sensor 2 × Card Slot: 4COM/8DIAI/8DOAO
Run/Alarm Indicator 2× DO 3 × COM
RDU-A G2 access capability
Option1:
Networking Networking by RS485, with up to 16 intelligent devices in
for intelligent system (Every COM port support up to 4 intelligent devices
devices with same type which support daisy chain connection)
Option2:
Networking by SNMP(RDU-SIC card/ SNMP card), with
up to 16 intelligent devices in system
Networking by SNMP
Networking by RS485 ports
3 x RS485 series port Two Ports share
2 × 4COM extension card with
for intelligent devices one same bus
up to 8 x RS485 series port
RDU-A G2
Every COM Port supports only one Note:
type of intelligent device! 1. When adding one 4COM card, the access capability adds 4.
2. The max access capability can extend to 32 by installing
authorization code.
RDU-A G2 access capability
1. Sensor1 supports to connect 16
T/TH sensors whose number
address is 1 in daisy chain.
2. Sensor2 supports to connect 16 T/TH
knots, T/TH sensors whose
number address is 2 in daisy
Environmental chain or 4DI (only 01 and 10) .
3. Smoke sensor port (only 2) or
4DI extension modular. Leakage
4. DI1&DI2 port for water leakage
sensor, door magnetic sensor or
4DI
infrared detective.
Remark: Extension modular
T/ TH/Door/water/4DI/4DO/DO = 1 knot
Infrared
Smoke/Infrared = 4 knots
Smoke
Door
magnetic

。。。
sensor
Video 1. 2 x USB for Camera On
Surveillance Line Real-time surveillance
2. 1 x USB for Camera, 1 x
USB for SMS Modem Cable total length in
single port <=100m
RDU-A G2 access capability
EMR Intelligent Devices supported
(standard configuration or SFA)
Cooling
Third Party Intelligent Device supported
depending on specific protocol
(RS485 / SNMP)
(Through SFA process, charged)
EMR Intelligent Devices supported
(standard configuration or SFA)
Power Third Party Intelligent Device supported
depending on specific protocol
(RS485/SNMP)
(Through SFA process, charged)
SMS Modem support
2G/3G Mobile Network GSM/WCDMA
–Huawei E220
–Huawei E173u-1,E173u-2,E173u-3,E173s-6
–Huawei E303
–Huawei E1750
–Huawei E1752cu
–Huawei E1762
–e-TEK TD-8311USB
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-SIC G2
RDU-SIC G2
A monitoring card used for
Liebert UPS\PDU\Air Condition\Sensors
IRM 4DI Smoke
Door
Magnetic
USB 2G IRM T/H
Modem Sensor
1-wire Sensor
……
LTS Battery Monitor
ITA UPS MPS
PDU
APM 150 DME
3000
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-SIC G2
• RDU-SIC G2 (02311887)
– Replace the 1-wire port with COM port
– Enhanced hardware platform (CPU180Mhz->450Mhz \Memory 32M->64M \Linux 2.4-
>2.6)
– 3G modem supported: Same as RDU-A G2(Huawei E173U,.etc)
– RDU-UA software platform
– No more Java compatible issues
– SNMP V3 supported
– MIB export supported
– Access ready for ITS remote
monitoring service platform
– Enhanced storage capacity on log and events
– Batch configuration supported
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-SIC G2
Equipment name Equipment type
• Port & default Devices support ITA 1kVA ~ 3kVA
ITA 5VA, 6kVA, 10kVA
ITA 16kVA ~ 20kVA
ITA 30kVA ~ 40kVA
GXT 3G
UPS
GXT 4G
APM 150
Liebert APS
GXE
Mini SPM (M90)
DATAMATE 3000
ATP
PACC
Air conditioner
CRV+
SDC2
SPC
16A LTS (STS Single)
Water-cooled cabinet (W081322-
30/W081322A-30)
Cabinet and others
Battery detector BM42
Clever PDU (OEM)
MPS PDU
IRM TH Sensor/4DI
Note: The range of the intelligent equipment that can be
All rights reserved 版权所有,仿冒必究 connected to the RDU-SIC G2 card is subject to change
Company Confidential 公司机密,不得公开
without notice
RDU-EX
RDU-EX
• The independent rack mount
• Independent power supply
• Mini box (42mm*130mm*170mm)
• For Rack using IRM 4DI Smoke
Door
Magnetic
USB 2G IRM T/H
Modem Sensor
……
LTS Battery Monitor
ITA UPS MPS
PDU
APM 150 DME
3000
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-EX Ports
• 3 ports for RS-485
• 1 port for RS-232/485 compatible
LAN USB COM1 Sensor COM2 COM3
US 485/ 232/4
网口 485 485
Internet
Internet
Internet B 12V 85
Monitor
Console
Modem
TH TH TH TH 4DI 4DI
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-EX Installation
• 3 ways to Rack Mounting
– With Baffle Panel, airflow isolate
– Rack Mount, on bracket
– Hanging Mode, magnetic forces
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-EX Capacity
Max
Device type Description
number
COM1, Sensor, COM2 and COM3 can connect intelligent device,
Intelligent
4 and up to 2 devices can be connected to each interface and totally 4
device
devices can be connected.
The Sensor interface can connect sensors and can connect up to 4
IRM TH sensors and 2 extended IRM-4DI ;
Sensor 4+2 The modbus address of IRM-TH sensors are 20, 21, 22 and 23 by
default;
The modbus address for IRM-4DI sensors are F0, F1 by default;
Note: 1.The total length of the cable connected to the interface is less than 100m.
2. When the sensor port is connected to a sensor, it cannot connect any intelligent device.
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-M
RDU-M
A top tier monitoring platform in RDU system
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-M
• A top tier monitoring platform in RDU system
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-M
Configuration RDU-MP RDU-MI RDU-MII
RDU-M II
Install Rack
Hight 1U
Hardware

Network network card 1: Monitor network


Card network card 2: Device Comm. network
Storage 500G 1T 2T
Power Single Power Single Power Double Power
RDU-M I
Video No Yes, Yes,<=256Camera
Software

<=32 Camera
RDU-A <=32 RDU-A <=10 RDU-A <=256 RDU-A
Num.
RDU-MP
RDU App
RDU App
• Android version is available now
• iOS version is in developing
• Support RDU-A G2 V4.5 RDU-M V3.5, RDU-EX\RDU-SIC
\SmartCabinet support feature will be release soon.
http://mobile.emersonnetwork.com.cn/SmartRowSAppDownLoad/RDUApp.htm
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU App Features
• System configure, Internationalize
• Data center over view
• Datacenter real time alarm push
• Datacenter real time status monitoring
• Favorite device signal view
• History data report
• Real time alarm acknowledgement
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
RDU-APP User Interface
All rights reserved 版权所有,仿冒必究
Company Confidential 公司机密,不得公开
Thanks!