Troubleshooting Plan - Autosampler and BD Prover Repair 07 12 2021
Troubleshooting Plan - Autosampler and BD Prover Repair 07 12 2021
Remarks: This document is confidential and issued strictly for official purpose only. No part of these document shall be wholly or partly
duplicated or disclosing same to others without the written and approved authority of the company.
TABLE OF CONTENTS
1 INTRODUCTION......................................................................................................................3
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
2. PURPOSE OF VISIT..................................................................................................................3
1.
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
1 INTRODUCTION
Sequel to the site visit conducted at the LACT unit on the 26 th November 2021 and the therein
recommendation to conduct a follow-up troubleshooting exercise, Terra Energy Services Nigeria
Limited (hereinafter referred to as the Contractor) will embark on a diagnostic site visit as part of
the commencement of the CALL-OUT CONTRACT FOR THE PROVISION OF
AUTOSAMPLER, SMALL VOLUME PROVER, AND BI-DIRECTIONAL PROVER
MAINTENACE SERVICES AND OPERATIONAL SPARES FOR OGHAREFE LACT UNIT IN
OML 111.
2. PURPOSE OF VISIT
To correctly diagnose the defective elements of the existing autosampler unit, prover unit and
ancillary equipment at the LACT unit necessary to bring these equipment into functioning condition
as required by the client and par international standard, the contractor will be carrying out
appropriate testing and troubleshooting exercise.
Note: All troubleshooting and diagnosis exercise of the autosampler and bi-directional prover loop at
the LACT unit, will be conducted in compliance with appropriate code and standard.
For the Jiskoot autosampler unit, the following lists highlights our troubleshooting exercise for this
equipment:
The Jiskoot Autosamplers, like other Jiskoot autosamplers, is equipped with a controller
called Inspec controller. The function of this controller is to control the grab functionality
of the equipment. We will be conducting sampling system controller troubleshooting check
to test to determine the functioning state of the device, if it still reusable, require
maintenance services, etc.
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
Based on our visual and physical inspection of the sampling probe, which appears to be
impaired, we will be troubleshooting the device to confirm if it is defective, not fit for use,
still in working condition that requires maintenance services, etc. wherein the probe is in
working condition, we will perform grab efficiency test exercise on the probe to determine
it functionality.
Conduct solenoid valve check on the equipment to determine the condition of these valves.
The existing Jiskoot autosampler is equipped with two solenoid valves, one of the valves
performs grabbing function while the other performs automatic changeover from one
canister to the other.
Conduct instrument integrity checks on the autosampler instruments (pressure transmitter,
temperature sensor, etc.) to determine if these instruments are useable, requires
maintenance services or need replacement.
In furtherance to our initial site visit report on the control system for this equipment, we
will be powering this device and conducting diagnostics on the flow computer, HMI,
instrument cables, junction box and associated electricals.
For the FMC bi-directional prover loop unit, the following lists highlights our troubleshooting
exercise for this equipment:
Picture References 1
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
Based on our initial recommendation on this equipment, we our troubleshooting exercise for this
equipment will involve:
Conducting critical functional test for the observed leaks as well as determining the
condition of the mixer (if it still working, requires maintenance, need parts replacement,
etc.)
Based on our initial site visit recommendation to procure new distribution board for the control
room, we will be conducting electrical continuity test on the general electrical system in the control
room. This is to help us understand the electrical wiring of the control and properly size the new
distribution board to procure and install in the control room.
Picture References 2
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
4.0. EQUIPMENT
The following are list of equipment we use for conducting the troubleshooting exercise:
i. HART Communicator
ii. Field Communicator
iii. Decade resistance box
iv. Temperature calibrator
v. Druck pressure calibrator
vi. Multimeter
vii. Pressure gauge
viii. Thermometer
ix. Mechanical toolbox (containing wrenches, spanners, pliers, etc.)
x. Electrical and instrumentation toolbox
5.0. RESPONSIBILITIES
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.
THE REPAIR AND RECERTIFICATION OF
AUTOSAMPLER AND BI-DIRECTIONAL PROVER IN
AMUKPE LACT UNIT
Troubleshooting Plan
i. Company shall authorize the Contractor through its representative to commence
troubleshooting and diagnosis exercise of the autosampler and bi-directional prover
loop.
ii. The Contractor shall supply all test equipment, material and qualified personnel for the
troubleshooting and diagnosis of the autosampler and bi-directional prover loop
THE Contractor shall submit all reports relating to the troubleshooting and diagnosis of the
autosampler and bi-directional prover loop to Company.
On completion successful completion of this scope, housekeeping activities will be carried out
before demobilization of personnel and equipment
This document is the property of TERRA ENERGY and must not be reproduced, stored, or disclosed without permission from COMPANY.