0% found this document useful (0 votes)
25 views1 page

Assignment 2

The document is an assignment from an Integrated Polytechnic Regional College in Rwanda for a module on basic geotechnical engineering. It contains two questions: the first asks the student to use Terzaghi's bearing capacity factors to determine the gross allowable load per unit area for a given continuous foundation, and the second asks the student to determine the size of a square footing needed to support a given gross load using a factor of safety of 3.

Uploaded by

Wilfharry billy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views1 page

Assignment 2

The document is an assignment from an Integrated Polytechnic Regional College in Rwanda for a module on basic geotechnical engineering. It contains two questions: the first asks the student to use Terzaghi's bearing capacity factors to determine the gross allowable load per unit area for a given continuous foundation, and the second asks the student to determine the size of a square footing needed to support a given gross load using a factor of safety of 3.

Uploaded by

Wilfharry billy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

IPRC GISHARI

P.O. Box60 RWAMAGANA -


RWANDA
Tel:+ 250 788 329 149
Integrated Polytechnic Regional College Email:[email protected]

Module’s details Trainee’s details


SECTOR Construction and Building Services Reg. No
SUB-SECTOR Construction Technology Name
MODULE (Code CSTGE701 Basic Geotechnical Engineering
& title) Other information
Competence Apply basic geotechnical engineering Trainer NZITUNGA Emmanuel
Learning Unit LU2. Analyze shallow foundations Duration
Learning Outcome Date ……../02/2023

Assignment No 2 Marks

1. Some determined values for a continuous foundation are given below: Using Terzaghi’s bearing
capacity factors, determine the gross allowable load per unit area that the foundation can carry.
Given: γ =18.07KN/m3, C=19.15KN/m2, ф =250, Df= 0.6096m, B=0.762m, Factor of safety = 4.
Assume general shear failure. (Answer: the gross allowable load per unit area that the foundation can
carry =169.9KN/m2)

2. A square foundation is shown in figure below: The footing will carry a gross load of 60,000lb.Using a
factor of safety of 3, determine the size of the footing-That is, the size of B. (still assume the case of