The document provides technical specifications for the DTG1000B generator. It has a prime rated power of 1000 kVA and emergency standby rating of 1100 kVA. Key features include a Stamford or Meccalte alternator, Baudouin 12M26G1100/5 engine, and set mounted control panel. The generator set is skid mounted and meets standards like BS5000, ISO 8528, and ISO 3046. It provides power at 400/230 volts and 1500 RPM.

Uploaded by

chris connors
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

DT Gen-Technical Data Sheet - DTG1000B-2023

The document provides technical specifications for the DTG1000B generator. It has a prime rated power of 1000 kVA and emergency standby rating of 1100 kVA. Key features include a Stamford or Meccalte alternator, Baudouin 12M26G1100/5 engine, and set mounted control panel. The generator set is skid mounted and meets standards like BS5000, ISO 8528, and ISO 3046. It provides power at 400/230 volts and 1500 RPM.

Uploaded by

chris connors
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TECHNICAL DATA SHEET

DTG1000B
GENERATOR SPECIALISTS

POWER RATING & VOLTAGE


PRP Rating: 1000 kVA
ESP Rating: 1100 kVA
DCC Rating: OA
3 Phase, 400/230 Volts, 1500 RPM, 50 Hz, 0.8 pf

CIRCUIT BREAKER
Set mounted 3-pole fixed output breaker, rated to maximum
output of generator set
Manufacturer: ABB OR SCHNEIDER
Rating: 1600 Amp

ALTERNATOR DIMENSIONS
Make: Stamford or Meccalte Length: 4800 mm
Model: TBA Width: 2050 mm
Insulation Class: Class H Height: 2200 mm
Ingress Protection: IP23 Wet Weight: 7,800 kg
No. of Poles: 4
No. of Bearings: 1 (Single)
Voltage Regulation: ±1%

ENGINE GENERATOR SET BUILD OPTIONS


Make: Baudouin • Close coupled and remote engine cooling
Model: 12M26G1100/5
• Comap & Deepsea control systems
Configuration: Vee 12 Turbocharged
• 4 Pole air circuit breakers
Governing: Electronic
Displacement: 31.8 litres • Remote oil level tanks
Fuel Consumption: 205 Litres/hr @ ESP Rating • Loadbank circuit breakers
Electrical System: 24v • Dual starting systems

GENERATING SET STANDARDS load with diesel fuel with specific gravity of 0.85 and conforming to
BS2869: 1998, Class A2, EN590.
The equipment meets the following standards: BS5000, All data provided subject to manufacturing tolerances.
ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
Skid mounted generator set with 1500 RPM industrial water
cooled diesel engine, brushless self-regulating alternator, POWER RATINGS
set mounted control panel (2 wire start), 24 Volt heavy duty lead
acid staring batteries, battery leads, starter motor, charge alternator, ESP - Emergency Standby to ISO 8528. limited to 200 hours per
anti-vibration mountings, 3 pole fixed type circuit breaker. Generators annum, 70% average load.
configuration includes a self-regulating battery charger and a PRP - Prime Rated Power to ISO8528, unlimited hours , 70% average load.
thermostatically controlled engine water jacket heater (Both DCC - Data Centre Continuous , unlimited hours, 100% load. Strictly for
require a separate single phase auxiliary supply). DC application only.

Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m Ratings based on ambient temperature 35 DegC / NTP Conditions.
(328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full For kW ratings apply a multiplication factor of 0.8 to the kVA rating.