Rendered PDF File Page 1 of 3 DOC0336974, Rev:1

Electronic Signature Information

Name DOC0336974

Revision 1

Type Generic Document

Title Archived PDS for Cardiac XRay Analysis

Originator 100008808_maria__juhasz

Name Reason For Change File Size (Bytes)


datasheetSCALArevM4.pdf Archived PDS for Cardiac XRay Analysis at Scala Program M4 197407
Archived PDS for Cardiac XRay Analysis at XR Pasting
datasheetSCALA_March2005.pdf 220053
Program M3

There are no signatures or routes related to this business object.

* Printed versions are For Reference Only *


Rendered PDF File Page 2 of 3 DOC0336974, Rev:1

Product Data Cardiac X-Ray Analysis Applications


June 2004 S18021 CA/SA/VA

Introduction
CardioVascular X-Ray Analysis
Applications are optional software
packages, that consist of Vessel Stenosis
Analysis and Left Ventricle Function
Analysis packages. They both run on the
Advantage Workstation.

Cardiovascular X-Ray Analysis


applications can be conducted on XA
DICOM modality images acquired with a
GE Vascular system belonging to the
Innova Digital Flat Panel family.

Application Description
Stenosis Analysis
Stenosis Analysis is an application
designed for estimating vessel
dimensions and relevant parameters of
the arterial Stenosis morphology in X-ray
angiography. It is an expert tool
applicable on:
- cardiac vessels
- peripheral vessels in subtracted
format
Based on the user’s manual identification
of the vessel to be analyzed, the software
automatically detects the vessel edges and perform Wall Motion and Global Requirements
displays the stenosis severity. Ejection Fraction (GEF).
- Wall Motion analysis is built upon - Advantage Workstation 4.2
In order to display measurements in
the centerline method. - Innova Digital Flat Panel X-ray system
millimeters, the operator needs to
perform calibration. It can either be done: - GEF analysis provides results
calculated with both the Simpson’s Regulatory Compliance
- automatically, based on the known
system geometry, rule method and the Dodge-Sandler The CardioVascular X-Ray Analysis
- from an empty catheter present in area-length method. Applications is CE marked (Medical
the image to analyze. Devices Directive 93/42/EEC).

Report/Filming Product Offerings


A Report containing all measurement CardioVascular X-ray Applications, inc.
Left Ventricle Analysis
information is displayed on the screen. It Stenosis and Left Ventricle Analysis:
Left Ventricle Analysis is an expert can then be saved as an image (DICOM - S18021CA
reporting tool designed to estimate wall Secondary Capture) and can then be
motion dynamics of the left ventricle, and filmed (printed) as any other image. It Stenosis Analysis:
to perform Global Ejection Fraction can also be archived on a CD-ROM or - S18021SA
analysis in X-ray angiography. saved as a JPEG file, using the extensive
Based on the user’s manual delineation of functionalities of the Advantage Left Ventricle Analysis:
the end-diastolic and end-systolic Workstation. - S18021VA
contours, the software provides means to

g
Data subject to change.
GE Healthcare
GE Medical Systems-Americas:
For more information,contact your GE Medical Systems representative Milwaukee, WI, USA, Fax: +1 414 544 3384
or visit our Internet Web Site http://www.ge.com/medical/ GE Medical Systems - International:
Buc, France, Fax: +33 (0)1 30 70 96 66
© Copyright 2004 General Electric Company
GE Medical Systems, a General Electric Company, going to market as GE Healthcare 1/1
Rendered PDF File Page 3 of 3 DOC0336974, Rev:1

Product Data Cardiac X-Ray Analysis Applications


March 2005 S18021 CB/SB/VB

Introduction
CardioVascular X-Ray Analysis
Applications are optional software
packages, that consist of Vessel Stenosis
Analysis and Left Ventricle Function
Analysis packages. They both run on the
Advantage Workstation.

Cardiovascular X-Ray Analysis


applications can be conducted on XA
DICOM modality images acquired with a
GE Vascular system belonging to the
Innova Digital Flat Panel family.

Application Description
Stenosis Analysis
Stenosis Analysis is an application
designed for estimating vessel
dimensions and relevant parameters of
the arterial Stenosis morphology in X-ray
angiography. It is an expert tool
applicable on:
- cardiac vessels
- peripheral vessels in subtracted
format
Based on the user’s manual identification
of the vessel to be analyzed, the software
automatically detects the vessel edges perform Wall Motion and Global Requirements
and displays the stenosis severity. Ejection Fraction (GEF).
- Wall Motion analysis is built upon - Advantage Workstation 4.2
In order to display measurements in
the centerline method. - Innova Digital Flat Panel X-ray system
millimeters, the operator needs to
perform calibration. It can either be done: - GEF analysis provides results
calculated with both the Simpson’s Regulatory Compliance
- automatically, based on the known
system geometry, rule method and the Dodge-Sandler The CardioVascular X-Ray Analysis
- from an empty catheter present in area-length method. Applications is CE marked (Medical
the image to analyze. Devices Directive 93/42/EEC).

Report/Filming Product Offerings


A Report containing all measurement CardioVascular X-ray Applications, inc.
Left Ventricle Analysis
information is displayed on the screen. It Stenosis and Left Ventricle Analysis:
Left Ventricle Analysis is an expert can then be saved as an image (DICOM - S18021CB
reporting tool designed to estimate wall Secondary Capture) and can then be
motion dynamics of the left ventricle, and filmed (printed) as any other image. It Stenosis Analysis:
to perform Global Ejection Fraction can also be archived on a CD-ROM or - S18021SB
analysis in X-ray angiography. saved as a JPEG file, using the extensive
Based on the user’s manual delineation of functionalities of the Advantage Left Ventricle Analysis:
the end-diastolic and end-systolic Workstation. - S18021VB
contours, the software provides means to

g
Data subject to change.
GE Healthcare
GE Healthcare -Americas:
Milwaukee, WI, USA, Fax: +1 414 544 3384
For more information,contact your GE Medical Systems representative
or visit our Internet Web Site http://www.ge.com/medical/ GE Healthcare - International:
Buc, France, Fax: +33 (0)1 30 70 96 66
© Copyright 2005 General Electric Company
GE Medical Systems, a General Electric Company, going to market as GE Healthcare 1/1

You might also like