0% found this document useful (0 votes)
305 views

Electromagnetic Flow Meter: Q&T Instrument Co.,Ltd

The document describes an electromagnetic flow meter produced by Q&T Instrument Co., Ltd. It can measure the flow of conductive liquids with sizes ranging from DN3 to DN3000. The electromagnetic flow meter has no moving parts, is maintenance-free, and provides accurate bidirectional measurement with a range of liner, electrode, and size options. It is suitable for use in various industries to measure flows such as raw water, potable water, sea water, and waste water.

Uploaded by

Joan Rodriguez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
305 views

Electromagnetic Flow Meter: Q&T Instrument Co.,Ltd

The document describes an electromagnetic flow meter produced by Q&T Instrument Co., Ltd. It can measure the flow of conductive liquids with sizes ranging from DN3 to DN3000. The electromagnetic flow meter has no moving parts, is maintenance-free, and provides accurate bidirectional measurement with a range of liner, electrode, and size options. It is suitable for use in various industries to measure flows such as raw water, potable water, sea water, and waste water.

Uploaded by

Joan Rodriguez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 58

ELECTROMAGNETIC FLOW METER

Q&T Instrument Co.,Ltd


Web: www.qtmeters.com Tel: +86-0371-2788-0299 Fax: +86-0371-2666-9963
Address: No.1 Wangbai Road, Huanglong Industrial Park, Kaifeng City, Henan Province,China
CONTENT

QTLD Flange Electromagnetic Flow Meter 01


QTLD/T Tri-clamp Electromagnetic Flow Meter 11
QTLD/W Wafer Electromagnetic Flow Meter 16
QTLD/C Insertion Electromagnetic Flow Meter 21
QTLD/D Battery-powered Electromagnetic Flow Meter 29
QTLD/F Partially-filled Electromagnetic Flow Meter 36
QTLD/M Mini Electromagnetic Flow Meter 40
QTLD/J Slurry Electromagnetic Flow Meter 44
QTLD/R Reduced Bore Electromagnetic Flow Meter 50
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description
QTLD magnetic flow meter, also known as electromagnetic flow meter or mag meter, is widely used because less
obstruction, cost-effective and accurate measurement. Electromagnetic flow meter don't have any moving parts to
wear down, reducing the need for maintenance or replacement. We offer flowmeters with a range of liners,
electrodes, and sizes, which can meet various conductive liquids.

Compact Remote

01
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Industries

● Effluent Treatment Plant ● Chemical & Fertilizer Industries

● Sewage Treatment Plant Water Supply Scheme ● Dairy Industries

● Steel & Aluminum Industries ● Sugar Industries

● Food & Drug Industries ● Textile Processing Industries

Applications

Raw Water Potable Water Sea Water Waste Water

Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution

Features
Wide range of nominal diameters (DN3-3000) Bi-directional flow measurement

Independent of pressure, temperature, density and


viscosity High accuracy 0.2% available

No moving parts, maintenance-free Self-diagnosis function, empty pipe alarm, exciting


Automatic power failure recording function alarm
(optional)
Support data record / bluetooth / wireless
Built-in grounding electrodes communication

02
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN3-DN3000mm (1/8"-120")


Accuracy ±0.5% of reading at flow velocity ≥ 0.5m/s, ±0.2% optional at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium
Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS RTU standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20°C~60°C
Fluid Temperature Compact: -20°C~80°C, Remote: -20°C~120°C
PTFE (-20°C~150°C, DN15-DN1600)
FEP (-20°C~120°C, DN3-DN1800)
PFA (-20°C~160°C, DN3-DN800)
Liner Material
Polyurethane (-10°C~60°C, DN40-DN1600)
Neoprene (-10°C~80°C, DN40-DN3000)
Hard Rubber (-10°C~80°C, DN 40-DN3000)
Ceramic (-20°C~180°C, DN15-DN200)
Flange Standard DIN, ANSI, JIS
Measuring tube: SS304
Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
PN10 / PN16 / PN25 / PN40 DIN
Nominal Pressure
10K / 20K / 30 K JIS
150# / 300# / 600# ANSI
High pressure 42 MPa / ANSI 2500# can be customized
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, exciting alarm, empty pipe alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean

03
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Transmitter Drawing

Compact Transmitter

Remote Transmitter

04
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN15-DN600 Compact Electromagnetic Flow Meter DN15-DN600 Remote Electromagnetic Flow Meter
with DIN Drawing with DIN Drawing

Compact Mag Flow Meter Size Remote Mag Flow Meter Size

Nominal L φD φA H N–φh Nominal L φD φA H N–φh


Size Size
Pressure (mm) (mm) (mm) (mm) (mm) Pressure (mm) (mm) (mm) (mm) (mm)

15 200 95 65 332 4-φ14 15 200 95 65 220 4-φ14


20 200 105 75 332 4-φ14 20 200 105 75 220 4-φ14
25 200 115 85 335 4-φ14 25 200 115 85 223 4-φ14
32 200 140 100 352 4-φ18 32 200 140 100 240 4-φ18
40 200 150 110 362 4-φ18 40 200 150 110 250 4-φ18
50 200 165 125 375 4-φ18 50 200 165 125 263 4-φ18
65 PN16 200 185 145 395 4-φ18 65 PN16 200 185 145 283 4-φ18
80 200 200 160 402 8-φ18 80 200 200 160 290 8-φ18
100 250 220 180 422 8-φ18 100 250 220 180 310 8-φ18
125 250 250 210 452 8-φ18 125 250 250 210 340 8-φ18
150 300 285 240 485 8-φ22 150 300 285 240 373 8-φ22
200 350 340 295 542 12-φ22 200 350 340 295 430 12-φ22
250 450 405 355 607 12-φ26 250 450 405 355 495 12-φ26
300 500 445 400 652 12-φ22 300 500 445 400 540 12-φ22
350 550 505 460 707 16-φ22 350 550 505 460 595 16-φ22
400 600 565 515 770 16-φ26 400 600 565 515 658 16-φ26
PN10 PN10
450 600 615 565 820 20-φ26 450 600 615 565 708 20-φ26
500 600 670 620 872 20-φ26 500 600 670 620 760 20-φ26
600 600 780 725 994 20-φ30 600 600 780 725 882 20-φ30

05
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Size is from 1/2"-24", other sizes can be provided upon request.

Electromagnetic Flow Meter Circuit

1/2"-24" Compact Electromagnetic Flow Meter with ANSI 150# Drawing

Flange Pressure
Size H (mm) L (mm) φA (mm) φB (mm) N (mm) φh (mm)
Standard Rate
1/2" ANSI 150# 318 200 88.9 60.45 4 15.7
3/4" ANSI 150# 323 200 98.6 69.85 4 15.7
1" ANSI 150# 328 200 108 79.25 4 15.7
1¼" ANSI 150# 333 200 117.3 88.9 4 15.7
1½" ANSI 150# 343 200 127 98.6 4 15.7
2" ANSI 150# 363 200 152.4 120.7 4 19.1
2½" ANSI 150# 383 200 177.8 139.7 4 19.1
3" ANSI 150# 398 200 190.5 152.4 4 19.1
4" ANSI 150# 426 250 228.6 190.5 8 19.1
5" ANSI 150# 449 250 254 215.9 8 22.4
6" ANSI 150# 477 300 279.4 241.3 8 22.4
8" ANSI 150# 538 350 342.9 298.5 8 22.4
10" ANSI 150# 613 450 406.4 362 12 25.4
12" ANSI 150# 678 500 482.6 431.8 12 25.4
14" ANSI 150# 728 550 533.4 476.3 12 28.4
16" ANSI 150# 784 600 596.9 539.8 16 28.4
18" ANSI 150# 830 600 635 577.9 16 31.75
20" ANSI 150# 887 600 698.5 635 20 31.75
24" ANSI 150# 999 600 812.8 749.3 20 35.1

06
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Electromagnetic Flowmeter Circuit

1/2"-24" Remote Electromagnetic Flow Meter with ANSI 150# Drawing

Flange Pressure
Size H (mm) L (mm) φA (mm) φB (mm) N (mm) φh (mm)
Standard Rate
1/2" ANSI 150# 204 200 88.9 60.45 4 15.7
3/4" ANSI 150# 209 200 98.6 69.85 4 15.7
1" ANSI 150# 214 200 108 79.25 4 15.7
1¼" ANSI 150# 219 200 117.3 88.9 4 15.7
1½" ANSI 150# 229 200 127 98.6 4 15.7
2" ANSI 150# 249 200 152.4 120.7 4 19.1
2½" ANSI 150# 269 200 177.8 139.7 4 19.1
3" ANSI 150# 284 200 190.5 152.4 4 19.1
4" ANSI 150# 312 250 228.6 190.5 8 19.1
5" ANSI 150# 335 250 254 215.9 8 22.4
6" ANSI 150# 363 300 279.4 241.3 8 22.4
8" ANSI 150# 424 350 342.9 298.5 8 22.4
10" ANSI 150# 499 450 406.4 362 12 25.4
12" ANSI 150# 562 500 482.6 431.8 12 25.4
14" ANSI 150# 614 550 533.4 476.3 12 28.4
16" ANSI 150# 670 600 596.9 539.8 16 28.4
18" ANSI 150# 716 600 635 577.9 16 31.75
20" ANSI 150# 773 600 698.5 635 20 31.75
24" ANSI 150# 885 600 812.8 749.3 20 35.1

07
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Main Performance of Electrode Material

Electrode Material Application

Applicable to industrial and municipal water, wastewater and low corrosive mediums.
SS316L Widely used in petroleum, chemical industries.

Strong resistance to hydrochloric acids below the boiling point.


Hastelloy B Resist against oxidable acids, alkali and non-oxidable salts, like vitriol,phosphate,
hydrofluoric acids and organic acids.

Exceptional resistance to strong solutions of oxidizing salts and acids, like Fe+++, Cu++,
Hastelloy C
Nitric acids, mixed acids.

Titanium can withstand corrosive mediums such as seawater, chloride salt solutions,
Titanium hypochlorite salts, oxidable acids (including fuming nitric acids), organic acids, and alkali.
Not resistant to high purity reducing acids such as sulphuric acids, hydrochloric acids.

Highly resistant to corrosive mediums.Applicable to all chemical mediums except


Tantalum Hydrofluoric Acids, Oleum and Alkali.

Platinum-iridium Applicable to all chemical mediums except for Ammonium salts and Fortis.

Main Performance of Liner Material

Best chemical resistance, withstand boling hydrochloric acid, sulfuric acid,nitric acid,
PTFE alkali and a variety of organic solvents.
Poor wear resistance and poor adhesion.

Highly resistant to chemicals.


PFA Performance well under vacuum pressure condition.

Excellent elasticity, good abrasion resistance.


Neoprene Withstand the corrosion of low-concentration acid, alkali, salt and other media.
Not resistant to corrosion by oxidizing medium.

Strong abrasion resistant, applicable for slurries and muds.


Polyurethane
Poor corrosion resistance, can't be used for corrosive medium.

Withstand the corrosion of hydrochloric acid, acetic acid, oxalic acid, ammonia water,
Hard Rubber phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide.
Use for general acid, alkali, and salt solutions, not resistant to the corrosion of strong oxidants.

Withstands high temperature, corrosion and wear


Ceramic Smooth inner
Totally vacuum resistant

08
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table QTLD

QTLD X X X X X X X X X X X
Caliber size DN3-DN3000 (1/8"-120")
Compact 1
Remote 2
Structure
Compact with explosion proof 3
Remote with explosion proof 4
±0.5% 1
Accuracy ±0.2% 2
Others 3
PTFE 1
FEP 2
PFA 3
Neoprene 4
Lining Material
Polyurethane 5
Hard Rubber 6
Ceramic 7
Others 8
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply 9~36 VDC solar power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/ Communication 4~20 mA + Profibus PA/DP C
GPRS D
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25, D40: DIN PN40 D**
Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
Process Connection JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2
Square A
Transmitter
Round B

09
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Flow Range Table

Size Flow Range & Velocity Table

mm Inch 0.1 m/s 0.2 m/s 0.5 m/s 1 m/s 4 m/s 10 m/s 12 m/s 15 m/s

DN3 1/8" 0.003 0.005 0.013 0.025 0.102 0.254 0.305 0.382
DN6 1/4" 0.01 0.02 0.051 0.102 0.407 1.017 1.221 1.526
DN10 3/8" 0.028 0.057 0.141 0.283 1.13 2.826 3.391 4.239
DN15 1/2" 0.064 0.127 0.318 0.636 2.543 6.359 7.63 9.538
DN20 3/4" 0.113 0.226 0.565 1.13 4.522 11.304 13.56 16.956
DN25 1" 0.177 0.353 0.883 1.766 7.065 17.663 21.2 26.494
DN32 1¼" 0.289 0.579 1.447 2.894 11.575 28.938 34.73 43.407
DN40 1½" 0.452 0.904 2.261 4.522 18.086 45.216 54.26 67.824
DN50 2" 0.707 1.413 3.533 7.065 28.26 70.65 84.78 105.98
DN65 2½" 1.19 2.39 5.97 11.94 47.76 119.4 143.3 179.1
DN80 3" 1.81 3.62 9.04 18.09 72.35 180.86 217 271.3
DN100 4" 2.83 5.65 14.13 28.26 113.04 282.6 339.1 423.9
DN125 5" 4.42 8.83 22.08 44.16 176.63 441.56 529.9 662.34
DN150 6" 6.36 12.72 31.79 63.59 254.34 635.85 763 953.78
DN200 8" 11.3 22.61 56.52 113.04 452.16 1130.4 1356 1696
DN250 10" 17.66 35.33 88.31 176.53 706.5 1766.25 2120 2649
DN300 12" 25.43 50.87 127.2 254.34 1017 2543.4 3052 3815
DN350 14" 34.62 69.24 173.1 346.19 1385 3461.85 4154 5193
DN400 16" 45 90 226.1 452 1809 4522 5426 6782
DN450 18" 57 114 286.1 572 2289 5723 6867 8584
DN500 20" 71 141 353.3 707 2826 7065 8478 10598
DN600 24" 102 203 508.7 1017 4069 10174 12208 15260
DN700 28" 138 277 692.4 1385 5539 13847 16617 20771
DN800 32" 181 362 904.3 1809 7235 18086 21704 27130
DN900 36" 229 458 1145 2289 9156 22891 27469 34336
DN1000 40" 283 565 1413 2826 11304 28260 33912 42390
DN1200 48" 407 814 2035 4069 16278 40694 48833 61042
DN1400 56" 554 1108 2769 5539 22156 55390 66468 83084
DN1600 64" 723 1447 3617 7235 28938 72346 86815 108518
DN1800 72" 916 1831 4578 9156 36625 91562 109875 137344
DN2000 80" 1130 2261 5652 11304 45216 113040 135648 169560
DN2200 88" 1368 2736 6839 13678 54711 136778 164134 205168
DN2400 96" 1628 3256 8139 16278 65111 162778 195333 244166
DN2600 104" 1910 3821 9552 19104 76415 191038 229245 286556
DN2800 112" 2216 4431 11078 22156 88623 221558 265870 332338
DN3000 120" 2543 5087 12717 25434 101736 254340 305208 381510
Remark: Recommend flow velocity range 0.5~15 m/s

10
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description

QTLD/T tri-clamp magnetic flow meter is designed for sanitary applications, size is DN15-DN200, the sensor is
SS304 or SS316 and lined with PFA. With tri-clamp, the magnetic flow meter can be installed and torn down easily
to clear, it meet the strict requirements of food-processing and pharmaceutical industries.

Industries

Food Processing CIP/SIP Industries Process or Industry

Filling and metering of Filling and metering of liquid


infusion products such as foods such as vegetable juice,
Pharmaceutical Industry Food and Beverage Industry saline and glucose water. juice, beer.

11
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Features
Tri-clamp electromagnetic flow meter is easy to be installed and dismantled.
It adopts harmless food grade stainless steel as raw material, so it can contact with food directly.
It is easy to clean, customer just need open the tri-clamp and dismantle the flow meter.
It has current output and pulse output for connecting with PLC or other devices. And user can also read flow
measurement by RS485/HART/Profibus.
Stainless steel material has long service life, and it can be used to measure most of drinks.

Technical Data
Size DN15-DN200 (1/2"-8")
Accuracy ±0.5% of reading at flow rate ≥ 0.5m/s, ±0.2% optional at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 std, IP68 (submersible, only available for remote type)
Electrode SS316L
Power Supply 85~250 VAC (50/60 HZ), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃
Liner material PFA
Measuring tube: SS304
Sensor Material
Tri-clamp & housing: SS304 standard, SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure 1.6 Mpa
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean

12
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN15-DN200 (1/2"-8'') Sanitary ( Tri-clamp) Electromagnetic Flow Meter Drawing (Compact)

Size
φA(mm) φB(mm) φC(mm) φD(mm) E(mm) H(mm) L(mm)
mm Inch

DN15 1/2" 50.5 43.5 16 76 2.85 303 200

DN20 3/4" 50.5 43.5 19 83 2.85 310 200

DN25 1" 50.5 43.5 24 83 2.85 310 200

DN32 1¼" 50.5 43.5 31 94 2.85 321 200

DN40 1½" 50.5 43.5 35 94 2.85 321 200

DN50 2" 64 56.5 45 108 2.85 335 200

DN65 2½" 77.5 70.5 59 115 2.85 342 250

DN80 3" 91 83.5 72 135 2.85 362 250

DN100 4" 119 110 98 159 2.85 386 250

DN125 5" 145 136 129 183 3.6 410 300

DN150 6" 183 174 150 219 3.6 446 300

DN200 8" 233.5 225 199 261 3.6 488 350

13
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN15-DN200 (1/2"-8") Sanitary (Tri-clamp) Electromagnetic Flow Meter Drawing (Remote)

Size
H(mm) L(mm) W(mm)
mm Inch

DN15 1/2" 188 200 76

DN20 3/4" 191 200 83

DN25 1" 191 200 83

DN32 1¼" 202 200 94

DN40 1½" 202 200 94

DN50 2" 216 200 108

DN65 2½" 223 250 115

DN80 3" 243 250 135

DN100 4" 267 250 159

DN150 6" 327 300 219

DN200 8" 369 350 273

14
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/T X X X X X X X X X

Caliber size DN15-DN200 (1/2"-8")

Compact 1

Remote 2
Structure
Compact with explosion proof 3

Remote with explosion proof 4

±0.5% 1

Accuracy ±0.2% 2

Others 3

SS316L 1

Hastelloy B 2
Electrode Material
Hastelloy C 3

Others 4

SS304 1
Sensor Material
SS316 2

85~265 VAC E

Power Supply 20~36 VDC G

Others X

4~20 mA + Pulse + RS485 Modbus A

4~20 mA + HART B
Signal Output
/Communication
4~20 mA + Profibus C

GPRS D

IP65 Transmitter + IP65 sensor 1


Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2

Square A
Transmitter
Round B

15
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description

QTLD/W wafer electromagnetic flow meter is designed with flangeless structure for minimum size and weight.
Eliminate gaskets and prevent moisture ingress with an all-welded sensor. No moving parts, which reduced the
maintenance and repair with an obstructionless design. Alignment rings are available to install easily.

Features

Wafer electromagnetic flow meter has short body, it can be


installed in narrow areas such as well, ditch, irrigation pipe, etc.

And wafer electromagnetic flow meter adopts harmless and


durable stainless steel as raw material(SS304 or SS316), so it
can be used for drinking water, underground water, etc. For food
grade measurement, we suggest customer use SS316 material.

Wafer electromagnetic flow meter is easy to deliver, save your


freight fee. Not only its body is short and thin, but its weight is
also very light.

It has multiple output signals for selection. It has current output


and pulse output for connecting with PLC or other devices. And
you can also read flow measurement by RS485/HART/Profibus.

16
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN25-DN200 /1"-8"


Accuracy ±0.5% of reading at flow rate ≥ 0.5m/s, ±0.2% optional at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%

Structure Compact / remote, cable length 10m standard, 100m max


Conductivity > 5 μS/cm, demineralized water > 20 µS/cm

Transmitter: IP65 standard, IP67 optional


Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)

Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium


Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W

Analog 4~20mA ( load resistor 0~750Ω)


Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz

Alarm Two isolated open collector transistor (OCT) outputs for alarm signals

Communication RS485 MODBUS std, HART, GPRS, PROFIBUS optional

Display LCD Display,128X128mm, three lines, 4 buttons

Ambient Temperature -20℃~60℃

Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃

Liner Material PTFE FEP PFA

Sensor Material Carbon steel (standard), SS304 / SS316 optional

Transmitter Material Aluminium alloy with epoxy painting

Nominal Pressure 1.6 Mpa

Display Instantaneous flow, total flow, flow velocity

Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis

Totalizer Three built-in totalizers: forward flow, reverse flow and net flow

Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h

Language English, Chinese, Italian, Portuguese, French, Spanish, Korean

17
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN25-DN200 (1"-8") Wafer Electromagnetic Flow Meter Drawing (Compact)

Size
φA(mm) φB(mm) φC(mm) H(mm) L(mm)
mm Inch

DN25 1" 60.5 68 22 295 100

DN32 1¼" 68.5 76 30 303 100

DN40 1½" 74.5 89 36 316 100

DN50 2" 90.8 102 48 329 100

DN65 2½" 109.8 119.5 64 346.5 150

DN80 3" 120.7 133 77 360 150

DN100 4" 150.2 159 102 386 150

DN125 5" 174.8 190 121 417 200

DN150 6" 204.7 219 147 446 200

DN200 8" 257.8 237 207 500 200

18
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Size
Size Inch φA(mm) φB(mm) L(mm) H(mm)

DN25 1" 60 68 98 181

DN32 1¼" 68 76 98 189

DN40 1½" 74 89 98 202

DN50 2" 90 102 98 215

DN65 2½" 110 120 146 233

DN80 3" 120 132 146 245

DN100 4" 150 159 146 272

DN150 6" 204 219 196 332

DN25-DN150 (1"-6") Wafer Electromagnetic Flow Meter Drawing (Remote)

19
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/W X X X X X X X X X X

Caliber size DN15-DN200 (1/2"-8")


Compact 1
Remote 2
Structure
Compact with explosion proof 3
Remote with explosion proof 4
±0.5% 1
Accuracy ±0.2% 2
Others 3
PTFE 1
PFA 2
Lining Material
FEP 3
Others 4
SS316L 1
Hastelloy B 2
Electrode Material
Hastelloy C 3
Others 4
Carbon Steel 1
Sensor Material SS304 2
SS316 3
85~265 VAC E
20~36 VDC G
Power Supply 9~36 VDC solar power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A

Signal Output 4~20 mA + HART B


/Communication 4~20 mA + Profibus C
GPRS D
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2
Square A
Transmitter
Round B

20
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description

QTLD/C insertion electromagnetic flow meter is used to


measure the flow of conductive liquids. It is available for use
in pipes ranging in size from DN100 to DN3000. It can
configure thread or flange ball valve to be hot-tapped, which
allows sensor to be installed and retracted from process
piping without shutting down the process.

It's an economic alternative when installed in large pipeline


no matter in cost and delivery compared with full bore
magnetic flow meter.

21
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Industries

Sewage Treatment Plant Steel & Aluminum


Effluent Treatment Plant Food & Drug Industries
Water Supply Scheme Industries

Chemical & Fertilizer Dairy Industries Sugar Industries Textile Processing


Industries Industries

Applications

Raw Water Potable Water Sea Water Waste Water

Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution

Features

No moving parts, no pressure loss and require very less maintenance.


More economical option for large pipelines flow measurement.
It can achieve hot-tapping online installation.
Simple structure, light weight and easy to transport.
Bi-directional flow measurement.
Automatic self-diagnosis.
Protection Class: IP68 (sensor submersible) available.

22
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN100-DN3000 (4"-120" )


Accuracy ±1.5% of reading at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinoiridium
Power Supply 85~250 VAC (50/60 Hz), 8~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature -20℃~80℃
G2" thread ball valve
Process connection
DN50 flange ball valve
Probe material: ABS standard, Polypropylene optional
Sensor material Valve: SS316
Pole: SS304
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure 1.6 Mpa
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h,t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean

23
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Type

Compact Insertion Magnetic Flow Meter


with Thread Ball Valve Remote Insertion Magnetic Flow Meter with Thread Ball Valve

Compact Insertion Magnetic Flow Meter


with Flange Ball Valve Remote Insertion Magnetic Flow Meter with Flange Ball Valve

24
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 693mm 1
400≥DN≥250 793mm 2 DN

1200≥DN>400 893mm 1
2000≥DN>1400 1093mm 4 DN

4"-80" Thread Ball Valve Insertion Electromagnetic Flow Meter Drawing (Compact)

Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 583mm 1
400≥DN≥250 683mm 2 DN

1200≥DN>400 783mm 1
2000≥DN>1400 983mm 4 DN

4"-80" Thread Ball Valve Insertion Electromagnetic Flow Meter Drawing (Remote)

25
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 480mm 1
400≥DN≥250 580mm 2 DN

1200≥DN>400 680mm 1
2000≥DN>1400 880mm 4 DN

4"-80" Flange Ball Valve Insertion Electromagnetic


Flow Meter Drawing (Compact)

26
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Insertion Electromagnetic Flow Meter

D≤400mm, H=1/2 D
D>400mm, H=1/4 D

Remarks:
Insertion depth has no relationship with pipe
thickness.For example, DN400 pipe thickness is
5mm, insertion depth should be ½ of 400mm, the L1
should be 200 mm.

FLOW

≥15D ≥10D
Upstream Downstream

27
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/C X X X X X X X X X

Caliber size DN100-DN3000/4"-120"

Compact 1

Remote 2
Structure
Compact with explosion proof 3

Remote with explosion proof 4

ABS 1
Probe
Polyurethane 2

SS316L 1

Hastelloy B 2
Electrode Material
Hastelloy C 3

Others 4

20~36 VDC G

85~265 VAC E
Power Supply
9~36 VDC solar power SD

Others X

4~20 mA + Pulse + RS485 MODBUS A

Signal Output 4~20 mA + HART B


/Communication C
4~20 mA + Profibus

GPRS D

IP65 Transmitter + IP65 sensor 1


Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2

Square A
Transmitter
Round B

G2" thread ball valve 1


Insertion
DN50 flange ball valve 2

28
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description
QTLD/D battery-powered electromagnetic flow meter is an ideal flow
measurement device for water and wastewater systems located at remote sites.
Various signal and communication are available like, pulse, RS485, all real-time
flow data can be monitored on computer or mobile phone by GPRS. Beside flow, it
also can measure temperature or pressure. With 5 pcs of 3.6V lithium battery,
lifespan is up to 8 years, and battery can be changed when it's used up. The
transmitter shell is SS304 and the protection grade is IP68, which is available to
be buried or submerged in the water.

Industries

Effluent Treatment Plant Chemical & Fertilizer Industries


Sewage Treatment Plant Water Supply Scheme Dairy Industries
Steel & Aluminum Industries Sugar Industries
Food & Drug Industries Textile Processing Industries

29
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Applications

Raw Water Potable Water Sea Water Waste Water

Heat Exchanger Industrial Acid alkali solution Cooling Water Irrigation

Features

It has a long life span, standard battery can work for 3-8 Multiple network interfaces:
01 04
years, determined by the excitation current. QTLD/D has GPRS, RS485, HART
and other network communication
02 Dual power supply: it’s equipped with external power for users.
supply interface, which can be powered by external 12-
24VDC power supply, enabling users to have a variety of 05 3.6V lithium battery can be
power options. changed if its used up.

03 Multiple work mode: QTLD/D has ‘Flow Only’ mode, ‘Flow 06 Infrared remote control display and
+ Pressure’ mode, ‘Flow +Temperature’ mode for users. operation.

Technical Data

Size DN10-DN2000 (3/8"~80")


Accuracy ±0.5% of reading at flow velocity≥0.5m/s, ±0.2% optional at flow velocity≥0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Structure Compact / remote, cable length 10m standard, 100m max

30
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Conductivity > 5 μS/cm, demineralized water > 20 µS/cm

Transmitter: IP65 standard, IP68 optional


Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)

Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium

Power Supply 3.6V lithium Battery

Power Consumption <20W

Signal Output 4~20 mA, Pluse

Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional

Display LCD Display,128X128mm, three lines, 4 buttons

Ambient Temperature -20℃~60℃

Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃

PTFE (-20℃~150℃, DN15-DN1600)

FEP (-20℃~120℃, DN3-DN1800)

PFA (-20℃~160℃, DN3-DN800)

Liner Material Polyurethane (-10℃~60℃, DN40-DN1600)

Neoprene (-10°C-80°C, DN4O-DN3000)

Hard Rubber (-10°C~80°C, DN 40-DN3000)

Ceramic (-20℃~180℃, DN15-DN200)

Process connection Flange, tri-clamp, wafer, thread, insertion

Measuring tube: SS304


Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional

Transmitter Material SS304

PN10 / PN16 / PN25 / PN40 DIN


Flange 10K / 20K / 30 K JIS 150# / 300# / 600# ANSI
Nominal Pressure Others

Insertion, tri-clamp, wafer, thread PN16

Display Instantaneous flow, total flow, flow velocity

Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis

Totalizer Three built-in totalizers: forward flow, reverse flow and net flow

Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h

31
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Measuring Mode

Forward, Reverse and Difference Value

Battery Symbol

Alarm Display
3
C
-0000012.78 m 30 Second Timer

00230R% -00.050 m/s


ACTIVE ACTIVE
Instantaneous Flow

Flow Rate

Percentage

Conductance Ratio Flow Mode

3 3 3
C C C
-0000012.78 m 30 -0000012.78 m 30 -0000012.78 m 30
1.900MPa -00.050 m/s A 080.0 -00.050 m/s 1.900MPa -00.050 m/s
ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE

lnlet Temperature A
Pressure Value
Outlet Temperature B
Instantaneous Flow State transition region
Temperature Difference D
Flow Rate
lnfrared remote control receive window
Percentage Instantaneous Heat / cold Flow
Conductance Ratio Instantaneous Flow Up display measuring state paging key
Flow Rate window/LCD Active window
Percentage Down display measuring state paging
Conductance Ratio key window/LCD Active window

Flow + Pressure Mode Flow + Temperature Mode Magnetic Key Operational Position

32
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Size Flange φh N
Standard Nominal Pressure H (mm) L (mm) φA (mm) φB (mm) (mm) (mm)
mm mm
DN15 1/2" DIN PN16 315 200 95 65 14 4
DN20 3/4" DIN PN16 320 200 105 75 14 4
DN25 1" DIN PN16 325 200 115 85 14 4
DN32 1¼" DIN PN16 337 200 140 100 18 4
DN40 1½" DIN PN16 347 200 150 110 18 4
DN50 2" DIN PN16 363 200 165 125 18 4
DN65 2½" DIN PN16 380 200 185 145 18 4
DN80 3" DIN PN16 396 200 200 160 18 8
DN100 4" DIN PN16 415 250 220 180 18 8
DN125 5" DIN PN16 440 250 250 210 18 8
DN150 6" DIN PN16 473 300 285 240 22 8
DN200 8" DIN PN16 530 350 340 295 22 12
DN250 10" DIN PN16 606 450 405 355 26 12
DN300 12" DIN PN16 659 500 460 410 26 12
DN350 14" DIN PN16 715 550 520 470 26 16
DN400 16" DIN PN16 770 600 580 525 30 16
DN450 18" DIN PN16 826 600 640 585 30 20
DN500 20" DIN PN16 889 600 715 650 33 20
DN600 24" DIN PN16 1007 600 840 770 36 20
DN700 28" DIN PN16 1093 700 910 840 36 24
DN800 32" DIN PN16 1201 800 1025 950 39 24
DN900 36" DIN PN16 1301 900 1125 1050 39 28
DN1000 40" DIN PN16 1426 1000 1255 1170 42 28

33
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Communication

Standard Battery-powered Without Output Signal Battery-powered with Pulse

Battery-powered with RS485 MODBUS Battery-powered with external GPRS

Process Connection

Flange Insertion Tri-clamp Thread Remote

34
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table
QTLD/D X X X X X X X X X
Caliber size DN10-DN2000 (3/8"-80")
Compact 1
Structure
Remote 2
PTFE 1
FEP 2
PFA 3
Neoprene 4
Lining Material
Polyurethane 5
Hard Rubber 6
Ceramic 7
Others 8
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
3.6 V lithium battery 1
3.6 V lithium battery and 12~24 VDC 2
Power Supply
3.6 V lithium battery and 85~265 VAC 3
Pulse P
Signal Output RS485 R
/Communication GPRS G
4~20 mA (need external power) 4
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25,
D**
D40: DIN PN40
Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
Process Connection IT
G2" thread ball valve
Insertion
DN50 flange ball valve IF
Tri-clamp TC
Wafer W
Thread T
Flow 1
Measuring Mode Flow + Temperature 2
Flow + Pressure 3

35
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description
QTLD/F partially-filled flowmeter is composed of converter, flow sensor and level sensor. The user only needs to
enter the diameter of pipe, the non-full pipe flowmeter will automatically calculate the flow rate, and automatically
display the instantaneous flow, total flow, velocity, height, etc. It can measure liquid volume min 10% of full pipe. It is
especially suitable for the needs of municipal rainwater, waste water, sewage discharge and irrigation.

Suitable For Low


Flow Rate

Can measure liquid


volume min 10% of full
pipe

Small Blind Zone


60mm

36
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Features
Partially filled pipe electromagnetic flow meter can measure partially filled pipe liquid flow, it is very popular in
irrigation.
Its can use solar power supply, this type is very suitable for remote areas where has no industrial power
supply.
It adopts safe and durable material, service life is longer than normal products. Normally, it can work at least 5-
10 years or longer.
And we have already got food grade certificate for its liner so it can be used for drinking water, underground
water, etc. Many drinking water companies use this type in their big size pipelines.
We use an accurate mini ultrasonic level meter for its liquid level measurement then the flow meter will record
the liquid level and use this parameter to measure liquid flow. This ultrasonic level meter's blind area is very
small and its accuracy can reach ±1mm.

Technical Data
Size DN200-DN3000 (8"-120")
Accuracy ±2.5% of reading at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Structure Remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium
Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication Rs485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature -20℃~120℃
PTFE (-20℃~150℃, DN200-DN1600)
FEP (-20℃~120℃, DN200-DN1800)
Liner Material
PFA (-20℃~160℃, DN200-DN800)
Polyurethane (-10℃~60℃, DN200-DN1600)
DIN PN10 / PN16 / PN25 / PN40 / PN64 / PN100
Flange JIS 10K / 20K / 30 K
ANSI 150# / 300# / 600#
Measuring tube: SS304
Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure 0.6Mpa, 150lb optional
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English

37
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Features

Electrode cable Level gauge cable


Excitation cable

DN200-DN1000 Drawing ( DIN Flange ),Other flange standards are available

Diameter Nominal
L (mm) H (mm) φA (mm) φK (mm) n*φh (mm)
(mm) pressure
Inch

DN200 8" 0.6 400 494 320 280 8*φ18

DN250 10" 0.6 450 561 375 335 12*φ18

DN300 12" 0.6 500 623 440 395 12*φ22

DN350 14" 0.6 550 671 490 445 12*φ22

DN400 16" 0.6 600 708 540 495 16*φ22

DN450 18" 0.6 600 778 595 550 16*φ22

DN500 20" 0.6 600 828 645 600 20*φ22

DN600 24" 0.6 600 934 755 705 20*φ22

DN700 28" 0.6 700 1041 860 810 24*φ26

DN800 32" 0.6 800 1149 975 920 24*φ30

DN900 36" 0.6 900 1249 1075 1020 24*φ30

DN1000 40" 0.6 1000 1359 1175 1120 28*φ30

38
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/F X X X X X X X X X
Caliber size DN200-DN3000(8"-120")
Remote 1
Structure
Remote with explosion proof 2
Neoprene 1
FEP 2
PFA 3
Lining Material PTFE 4
Polyurethane 5
Hard Rubber 6
Others 7
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply
9~36 VDC solar power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/Communication 4~20 mA + Profibus C
GPRS D
DIN D6:DIN PN6, D10: DIN PN10, D16: DIN PN16 D**
ANSI A15: ANSI 150# A**
Flange Standard
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor 2

39
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description

QTLD/M mini magnetic flow meter is an economical option for small pipe size
compared with other process connection, it includes transmitter and sensor, Which
enjoy the advantages of small and compact, no moving parts, maintenance-free, save
the installation space and reduce freight costs etc.The Magmeters is ideal for use in
the field of mechanical engineering and plant construction. It has DN3
/DN6/DN10/DN15 size, 4-20mA, Pulse and RS485 Modbus available.

Features

Integrated vertification, diagnostic function and empty pipe detection.

Bidirectional flow measurement.

RS485 interface supporting up to 2km distance at 14400 bps communication.

Programmable low frequency square wave field excitation, improving measurement stability and reducing
power consumption.

Implementing ‘Rate-Of-Change Limit’ technology to eliminate sharp electrical noise contained in the flow signal
and stabilize the display and outputs.

Optional real-time clock, power-failure and history data logging function, storing up to 30 days measurement
records.

40
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN3, DN6, DN10, DN15

Accuracy ±0.5% of reading at flow velocity≥ 0.5m/s

Velocity 0.3~15 m/s

Structure Compact

Conductivity > 5 μS/cm, demineralized water > 20 µS/cm

Protection Grade IP65

Electrode SS316L, Hastelloy C, Titanium

Power Supply 85~250 Vac (45~63Hz), 16~30 Vdc

Power Consumption <15W

Signal Output 4~20mA ( load resistor 0~75Ω), Pulse ( 0~5K Hz)

Communicaiton RS485 MODBUS

Ambient Temperature -10℃~55℃

Fluid Temperature -10℃~60℃

Sensor Material Measuring tube: PEEK

Process connection Thread, G1/2", 1/2"NPT, 1/2" BSP, G3/8" for DN3 and DN6 (optional)

Transmitter Material Aluminium alloy with epoxy painting

Nominal Pressure 1.6 Mpa

Display Instantaneous flow, total flow, flow velocity

Function High and low alarm, empty pipe alarm, self-diagnosis

Totalizer Three built-in totalizers: forward flow, reverse flow and net flow

L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h,
Display Unit
mass flow unit: kg/s, kg/m, kg/h,t/s, t/m, t/h

Language English, Chinese

41
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

1. Connector
2. Shell
3. Excitation Coil
4. Pole Shoe
5. Magnet Yoke
6. Bracket Plate Assembly
7. Fixed Block
8. Measuring Tube
9. Electrode-assembly

Caliber Nominal Dimension DN Flow Range(L/min)


Pressure Male Thread
mm Inch (Mpa) L(mm) D(mm) H(mm) B(mm) mm Inch Standard Special

3 1/8" 135 G1/2" 3 1/8" 0.2~2 0.2~4 G1/2"

6 1/4" 145 G1/2" 6 1/4" 0.8~8 0.8~16 G1/2"


1.6 100 70
10 3/8" 145 G1/2" 10 3/8" 2~20 2~40 G1/2"

15 1/2" 155 G1/2" 15 1/2" 5~50 5~100 G1/2"

42
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/M X X X X X

DN3 (1/8") 1

DN6 (1/4") 2
Size
DN10 (3/8") 3

DN15 (1/2") 4

G1/2" 1

G3/8" (only for DN3 and DN6) 2

NPT 1/2" 3

Process Connection NPT 3/8" 4

BSP 1/2" 5

BSP 3/8" 6

Others 7

SS316L 1

Electrode Material Hastelloy C 2

Titanium 3

85~265 VAC E
Power Supply
16~30 VDC G

4~20 mA + Pulse + RS485 MODBUS A


Signal Output
/Communication
GPRS D

43
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

The concentration
ratio of slurry can
reach 55%, and the variation
range is usually less
than 5%

Description

Noise is common in process fluids containing solid particulates, and it can influence the measurement, our slurry
magnetic flow meter adopts square wave excitation and 25Hz/30Hz high excitation, which can eliminate
interfacerence between the sharp wave noise generated by solid particles, ensures accurate measurement of
viscous medium.

44
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Industries

Cement slurry, sludge, gypsum slurry, paper pulp, juice, syrup, ore slurry, coal slurry, etc.

Oil Field Ore Slurry

Paper Pulp Gypsum Slurry Cement Slurry

Features

01 Special design grouting converter: Special converter can eliminate interfacerence between the sharp

02
wave noise generated by solid particles.

Medium concentration: the concentration of slurry can reach 55%, and the variation range is usually

03
less than 5%.

Excitation method: square wave excitation (4 kinds of square waves) impoves flow measurement

04 stability.

Excitation Frequency: 25 Hz/30 Hz excitation frequency for choose. High excitation frequency has

05 high anti-interference ability, ensures accurate measurement of viscous medium.

LCD backlight display: instantaneous flow, total flow, flow velocity, percentage flow, etc.

45
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN3-DN3000 (1/8"-120" )


Accuracy ±0.5% of reading at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Excitation current 125 mA, 187 mA, 250 mA
Excitation Frequency 25 Hz/30 Hz
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium
Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃
PTFE (-20℃~150℃, DN15-DN1600)
FEP (-20℃~120℃, DN15-DN1800)
PFA (-20℃~160℃, DN15-DN800)
Liner Material Polyurethane (-10℃~60℃, DN40-DN1600)
Neoprene (-10℃~80℃, DN40-DN3000)
Hard Rubber (-10℃~80℃, DN 40-DN3000)
Ceramic (-20℃~180℃, DN15-DN200)
Measuring tube: SS304
Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
PN10 / PN16 / PN25 / PN40 DIN
Flange 10K / 20K / 30 K JIS
Nominal Pressure 150# / 300# / 600# ANSI
Insertion, tri-clamp wafer, thread PN16
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm,self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese

46
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Process Connection

Tri-clamp

Compact
Thread

Wafer

Remote Union

47
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

Diameter
Flange Pressure H(mm) L(mm) φA(mm) φB(mm) φh(mm) N(mm)
mm Inch
DN15 1/2" ANSI 150# 343 200 88.9 60.45 4 15.7
DN20 3/4" ANSI 150# 348 200 98.6 69.85 4 15.7
DN25 1" ANSI 150# 353 200 108 79.25 4 15.7
DN32 1¼" ANSI 150# 358 200 117.3 88.9 4 15.7
DN40 1½" ANSI 150# 368 200 127 98.6 4 15.7
DN50 2" ANSI 150# 388 200 152.4 120.7 4 19.1
DN65 2½" ANSI 150# 408 200 177.8 139.7 4 19.1
DN80 3" ANSI 150# 423 200 190.5 152.4 4 19.1
DN100 4" ANSI 150# 451 250 228.6 190.5 8 19.1
DN125 5" ANSI 150# 474 250 254 215.9 8 22.4
DN150 6" ANSI 150# 502 300 279.4 241.3 8 22.4
DN200 8" ANSI 150# 563 350 342.9 298.5 8 22.4
DN250 10" ANSI 150# 638 450 406.4 362 12 25.4
DN300 12" ANSI 150# 701 500 482.6 431.8 12 25.4
DN350 14" ANSI 150# 753 550 533.4 476.3 12 28.4
DN400 16" ANSI 150# 809 600 596.9 539.8 16 28.4
DN450 18" ANSI 150# 855 600 635 577.9 16 31.75
DN500 20" ANSI 150# 912 600 698.5 635 20 31.75
DN600 24" ANSI 150# 1024 600 812.8 749.3 20 35.1

48
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD / J X X X X X X X X X X
Caliber size DN15-DN3000 (1/2"-120")
Compact C
Remote R
Structure
Compact with explosion proof CEP
Remote with explosion proof REP
±0.5% 1
Accuracy ±0.2% 2
Others 3
PTFE 1
FEP 2
PFA 3
Lining Material Neoprene 4
Polyurethane 5
Hard Rubber 6
Ceramic 7
SS316L 1
Hastelloy B 2
Hastelloy C 3
Electrode Material Titanium 4
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
Power Supply 85~265 VAC E
9~36 VDC solar power SD
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/Communication 4~20 mA + Profitbus C
GPRS D
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25, D40: DIN PN40 D**
ANSI A15: ANSI 150#, A30: ANSI 300#, A60:ANSI 600# A**
Flange
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Other O
Process Connection Insertion with G2" thread ball valve IB
Insertion
Insertion with DN50 flange ball valve IF
Tri-clamp TC
Wafer W
Thread T
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2

49
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Description

QTLD/R reduced bore electromagnetic flow meter is ideal for these applications with zero upstream or downstream
piping as they can better handle distorted velocity flow profiles arising from the pipe networks, allowing total
flexibility in installation for demanding applications compared with full bore magnetic flow meter. It can increase
velocity and flow if it’s low flow.

Industries
Sewage Treatment Plant Water
Textile Processing Industries Effluent Treatment Plant Supply Scheme

Steel & Aluminum Industries Food & Drug Industries Chemical & Fertilizer Industries

50
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Applications

Raw Water Potable Water Sea Water Waste Water

Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution

Features
01
02
No need straight pipe in the upstream an downstream.

03
It can increase velocity and flow if it’s low flow.

04
Self-diagnosis,empty pipe alarm, exciting alarm, high and low flow alarm.

Measure forward flow, reverse flow and net flow.

05 It has multiple output signals for choose, 4~20 mA+Pulse + RS485 Modbus are standard signal,
HART, Profibus, GPRS are optional.

Battery reduced bore Compact reduced bore Remote reduced bore

51
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Technical Data

Size DN50-DN300 (2"-12")


Sensor Reduced bore, U0+D0, don't need any straight pipe in the upstream and downstream

Accuracy ±0.5% of reading at flow velocity ≥0.5m/s, ±0.2% optional at flow velocity ≥0.5m/s

Velocity 0.1~15 m/s

Repeatability ≤0.17%

Structure Compact / remote, cable length 10m standard, 100m max

Conductivity > 5 μS/cm, demineralized water > 20 µS/cm


Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)

Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium

Power Supply 85~250 VAC (50/60 Hz), 8~36 VDC, 3.6V lithium battery

Power Consumption <20W


Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals

Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional

Display LCD Display,128X128mm, three lines, 4 buttons

Ambient Temperature -20℃~60℃

Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃

Liner Material Neoprene, hard rubber

Process connection Flange


Measuring tube: SS304
Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional

Transmitter Material Aluminium alloy with epoxy painting

Display Instantaneous flow, total flow, flow velocity

Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis

Totalizer Three built-in totalizers: forward flow, reverse flow and net flow

Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean

52
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN50-DN300 Compact Reduced Bore Magnetic Flow Meter DIN PN16 Drawing

Size
Flange Nominal Pressure L (mm) D (mm) H (mm) K (mm) n*d (mm)
mm Inch (MPa)
DN50 2" DIN 1.6 200 165 374 125 4*φ18

DN65 2½" DIN 1.6 200 185 377 145 4*φ18

DN80 3" DIN 1.6 200 200 392 160 8*φ18

DN100 4" DIN 1.6 250 220 419 180 8*φ18

DN125 5" DIN 1.6 250 250 434 210 8*φ19

DN150 6" DIN 1.6 300 285 462 240 8*φ22

DN200 8" DIN 1.6 350 340 504 295 12*φ22

DN250 10" DIN 1.6 450 405 567 355 12*φ26

DIN 1.0 500 445 630 400 12*φ22


DN300 12"
DIN 1.6 500 460 638 410 12*φ26

53
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Dimension

DN50-DN300 Remote Reduced Bore Magnetic Flow Meter DIN PN16 Drawing

Size
Flange Nominal Pressure L (mm) D (mm) H (mm) K (mm) n*d (mm)
mm Inch (MPa)
DN50 2" DIN 1.6 200 165 260 125 4*φ18

DN65 2½" DIN 1.6 200 185 263 145 4*φ18

DN80 3" DIN 1.6 200 200 278 160 8*φ18

DN100 4" DIN 1.6 250 220 305 180 8*φ18

DN125 5" DIN 1.6 250 250 320 210 8*φ19

DN150 6" DIN 1.6 300 285 348 240 8*φ22

DN200 8" DIN 1.6 350 340 390 295 12*φ22

DN250 10" DIN 1.6 450 405 453 355 12*φ26

DIN 1.0 500 445 516 400 12*φ22


DN300 12"
DIN 1.6 500 460 524 410 12*φ26

54
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd

Selection Table

QTLD/R x x x x x x x x x
Caliber size DN50-DN300 (2"-12")
Compact 1
Remote 2
Structure
Compact with explosion proof 3
Remote with explosion proof 4
±0.5% 1
Accuracy ±0.2% 2
Others 3
Neoprene 1
Lining Material
Hard Rubber 2
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply
9~36 VDC solor power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A

Signal Output 4~20 mA + HART B


/Communication 4~20 mA + Profibus C
GPRS D
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25, D40: DIN PN40 D**

Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
Standard JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O

55
Q&T Instrument Co.,Ltd

www.qtmeters.com Tel: +86-0371-2788-0299 Fax: +86-0371-2666-9963


Address: No.1 Wangbai Road, Huanglong Industrial Park, Kaifeng City, Henan Province, China