Electromagnetic Flow Meter: Q&T Instrument Co.,Ltd
Electromagnetic Flow Meter: Q&T Instrument Co.,Ltd
Description
QTLD magnetic flow meter, also known as electromagnetic flow meter or mag meter, is widely used because less
obstruction, cost-effective and accurate measurement. Electromagnetic flow meter don't have any moving parts to
wear down, reducing the need for maintenance or replacement. We offer flowmeters with a range of liners,
electrodes, and sizes, which can meet various conductive liquids.
Compact Remote
01
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Industries
Applications
Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution
Features
Wide range of nominal diameters (DN3-3000) Bi-directional flow measurement
02
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
03
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Transmitter Drawing
Compact Transmitter
Remote Transmitter
04
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
DN15-DN600 Compact Electromagnetic Flow Meter DN15-DN600 Remote Electromagnetic Flow Meter
with DIN Drawing with DIN Drawing
Compact Mag Flow Meter Size Remote Mag Flow Meter Size
05
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Flange Pressure
Size H (mm) L (mm) φA (mm) φB (mm) N (mm) φh (mm)
Standard Rate
1/2" ANSI 150# 318 200 88.9 60.45 4 15.7
3/4" ANSI 150# 323 200 98.6 69.85 4 15.7
1" ANSI 150# 328 200 108 79.25 4 15.7
1¼" ANSI 150# 333 200 117.3 88.9 4 15.7
1½" ANSI 150# 343 200 127 98.6 4 15.7
2" ANSI 150# 363 200 152.4 120.7 4 19.1
2½" ANSI 150# 383 200 177.8 139.7 4 19.1
3" ANSI 150# 398 200 190.5 152.4 4 19.1
4" ANSI 150# 426 250 228.6 190.5 8 19.1
5" ANSI 150# 449 250 254 215.9 8 22.4
6" ANSI 150# 477 300 279.4 241.3 8 22.4
8" ANSI 150# 538 350 342.9 298.5 8 22.4
10" ANSI 150# 613 450 406.4 362 12 25.4
12" ANSI 150# 678 500 482.6 431.8 12 25.4
14" ANSI 150# 728 550 533.4 476.3 12 28.4
16" ANSI 150# 784 600 596.9 539.8 16 28.4
18" ANSI 150# 830 600 635 577.9 16 31.75
20" ANSI 150# 887 600 698.5 635 20 31.75
24" ANSI 150# 999 600 812.8 749.3 20 35.1
06
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Flange Pressure
Size H (mm) L (mm) φA (mm) φB (mm) N (mm) φh (mm)
Standard Rate
1/2" ANSI 150# 204 200 88.9 60.45 4 15.7
3/4" ANSI 150# 209 200 98.6 69.85 4 15.7
1" ANSI 150# 214 200 108 79.25 4 15.7
1¼" ANSI 150# 219 200 117.3 88.9 4 15.7
1½" ANSI 150# 229 200 127 98.6 4 15.7
2" ANSI 150# 249 200 152.4 120.7 4 19.1
2½" ANSI 150# 269 200 177.8 139.7 4 19.1
3" ANSI 150# 284 200 190.5 152.4 4 19.1
4" ANSI 150# 312 250 228.6 190.5 8 19.1
5" ANSI 150# 335 250 254 215.9 8 22.4
6" ANSI 150# 363 300 279.4 241.3 8 22.4
8" ANSI 150# 424 350 342.9 298.5 8 22.4
10" ANSI 150# 499 450 406.4 362 12 25.4
12" ANSI 150# 562 500 482.6 431.8 12 25.4
14" ANSI 150# 614 550 533.4 476.3 12 28.4
16" ANSI 150# 670 600 596.9 539.8 16 28.4
18" ANSI 150# 716 600 635 577.9 16 31.75
20" ANSI 150# 773 600 698.5 635 20 31.75
24" ANSI 150# 885 600 812.8 749.3 20 35.1
07
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Applicable to industrial and municipal water, wastewater and low corrosive mediums.
SS316L Widely used in petroleum, chemical industries.
Exceptional resistance to strong solutions of oxidizing salts and acids, like Fe+++, Cu++,
Hastelloy C
Nitric acids, mixed acids.
Titanium can withstand corrosive mediums such as seawater, chloride salt solutions,
Titanium hypochlorite salts, oxidable acids (including fuming nitric acids), organic acids, and alkali.
Not resistant to high purity reducing acids such as sulphuric acids, hydrochloric acids.
Platinum-iridium Applicable to all chemical mediums except for Ammonium salts and Fortis.
Best chemical resistance, withstand boling hydrochloric acid, sulfuric acid,nitric acid,
PTFE alkali and a variety of organic solvents.
Poor wear resistance and poor adhesion.
Withstand the corrosion of hydrochloric acid, acetic acid, oxalic acid, ammonia water,
Hard Rubber phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide.
Use for general acid, alkali, and salt solutions, not resistant to the corrosion of strong oxidants.
08
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
QTLD X X X X X X X X X X X
Caliber size DN3-DN3000 (1/8"-120")
Compact 1
Remote 2
Structure
Compact with explosion proof 3
Remote with explosion proof 4
±0.5% 1
Accuracy ±0.2% 2
Others 3
PTFE 1
FEP 2
PFA 3
Neoprene 4
Lining Material
Polyurethane 5
Hard Rubber 6
Ceramic 7
Others 8
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply 9~36 VDC solar power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/ Communication 4~20 mA + Profibus PA/DP C
GPRS D
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25, D40: DIN PN40 D**
Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
Process Connection JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2
Square A
Transmitter
Round B
09
QTLD Flange Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
mm Inch 0.1 m/s 0.2 m/s 0.5 m/s 1 m/s 4 m/s 10 m/s 12 m/s 15 m/s
DN3 1/8" 0.003 0.005 0.013 0.025 0.102 0.254 0.305 0.382
DN6 1/4" 0.01 0.02 0.051 0.102 0.407 1.017 1.221 1.526
DN10 3/8" 0.028 0.057 0.141 0.283 1.13 2.826 3.391 4.239
DN15 1/2" 0.064 0.127 0.318 0.636 2.543 6.359 7.63 9.538
DN20 3/4" 0.113 0.226 0.565 1.13 4.522 11.304 13.56 16.956
DN25 1" 0.177 0.353 0.883 1.766 7.065 17.663 21.2 26.494
DN32 1¼" 0.289 0.579 1.447 2.894 11.575 28.938 34.73 43.407
DN40 1½" 0.452 0.904 2.261 4.522 18.086 45.216 54.26 67.824
DN50 2" 0.707 1.413 3.533 7.065 28.26 70.65 84.78 105.98
DN65 2½" 1.19 2.39 5.97 11.94 47.76 119.4 143.3 179.1
DN80 3" 1.81 3.62 9.04 18.09 72.35 180.86 217 271.3
DN100 4" 2.83 5.65 14.13 28.26 113.04 282.6 339.1 423.9
DN125 5" 4.42 8.83 22.08 44.16 176.63 441.56 529.9 662.34
DN150 6" 6.36 12.72 31.79 63.59 254.34 635.85 763 953.78
DN200 8" 11.3 22.61 56.52 113.04 452.16 1130.4 1356 1696
DN250 10" 17.66 35.33 88.31 176.53 706.5 1766.25 2120 2649
DN300 12" 25.43 50.87 127.2 254.34 1017 2543.4 3052 3815
DN350 14" 34.62 69.24 173.1 346.19 1385 3461.85 4154 5193
DN400 16" 45 90 226.1 452 1809 4522 5426 6782
DN450 18" 57 114 286.1 572 2289 5723 6867 8584
DN500 20" 71 141 353.3 707 2826 7065 8478 10598
DN600 24" 102 203 508.7 1017 4069 10174 12208 15260
DN700 28" 138 277 692.4 1385 5539 13847 16617 20771
DN800 32" 181 362 904.3 1809 7235 18086 21704 27130
DN900 36" 229 458 1145 2289 9156 22891 27469 34336
DN1000 40" 283 565 1413 2826 11304 28260 33912 42390
DN1200 48" 407 814 2035 4069 16278 40694 48833 61042
DN1400 56" 554 1108 2769 5539 22156 55390 66468 83084
DN1600 64" 723 1447 3617 7235 28938 72346 86815 108518
DN1800 72" 916 1831 4578 9156 36625 91562 109875 137344
DN2000 80" 1130 2261 5652 11304 45216 113040 135648 169560
DN2200 88" 1368 2736 6839 13678 54711 136778 164134 205168
DN2400 96" 1628 3256 8139 16278 65111 162778 195333 244166
DN2600 104" 1910 3821 9552 19104 76415 191038 229245 286556
DN2800 112" 2216 4431 11078 22156 88623 221558 265870 332338
DN3000 120" 2543 5087 12717 25434 101736 254340 305208 381510
Remark: Recommend flow velocity range 0.5~15 m/s
10
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/T tri-clamp magnetic flow meter is designed for sanitary applications, size is DN15-DN200, the sensor is
SS304 or SS316 and lined with PFA. With tri-clamp, the magnetic flow meter can be installed and torn down easily
to clear, it meet the strict requirements of food-processing and pharmaceutical industries.
Industries
11
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Features
Tri-clamp electromagnetic flow meter is easy to be installed and dismantled.
It adopts harmless food grade stainless steel as raw material, so it can contact with food directly.
It is easy to clean, customer just need open the tri-clamp and dismantle the flow meter.
It has current output and pulse output for connecting with PLC or other devices. And user can also read flow
measurement by RS485/HART/Profibus.
Stainless steel material has long service life, and it can be used to measure most of drinks.
Technical Data
Size DN15-DN200 (1/2"-8")
Accuracy ±0.5% of reading at flow rate ≥ 0.5m/s, ±0.2% optional at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65 standard, IP67 optional
Protection Grade
Sensor: IP65 std, IP68 (submersible, only available for remote type)
Electrode SS316L
Power Supply 85~250 VAC (50/60 HZ), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature Compact: -20℃~80℃, Remote: -20℃~120℃
Liner material PFA
Measuring tube: SS304
Sensor Material
Tri-clamp & housing: SS304 standard, SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure 1.6 Mpa
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean
12
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Size
φA(mm) φB(mm) φC(mm) φD(mm) E(mm) H(mm) L(mm)
mm Inch
13
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Size
H(mm) L(mm) W(mm)
mm Inch
14
QTLD/T Tri-clamp Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/T X X X X X X X X X
Compact 1
Remote 2
Structure
Compact with explosion proof 3
±0.5% 1
Accuracy ±0.2% 2
Others 3
SS316L 1
Hastelloy B 2
Electrode Material
Hastelloy C 3
Others 4
SS304 1
Sensor Material
SS316 2
85~265 VAC E
Others X
4~20 mA + HART B
Signal Output
/Communication
4~20 mA + Profibus C
GPRS D
Square A
Transmitter
Round B
15
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/W wafer electromagnetic flow meter is designed with flangeless structure for minimum size and weight.
Eliminate gaskets and prevent moisture ingress with an all-welded sensor. No moving parts, which reduced the
maintenance and repair with an obstructionless design. Alignment rings are available to install easily.
Features
16
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
17
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Size
φA(mm) φB(mm) φC(mm) H(mm) L(mm)
mm Inch
18
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Size
Size Inch φA(mm) φB(mm) L(mm) H(mm)
19
QTLD/W Wafer Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/W X X X X X X X X X X
20
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
21
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Industries
Applications
Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution
Features
22
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
23
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Type
24
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 693mm 1
400≥DN≥250 793mm 2 DN
1200≥DN>400 893mm 1
2000≥DN>1400 1093mm 4 DN
4"-80" Thread Ball Valve Insertion Electromagnetic Flow Meter Drawing (Compact)
Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 583mm 1
400≥DN≥250 683mm 2 DN
1200≥DN>400 783mm 1
2000≥DN>1400 983mm 4 DN
4"-80" Thread Ball Valve Insertion Electromagnetic Flow Meter Drawing (Remote)
25
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Specifications
lnsertion
Pipe Size Length(L)
Length L1
DN≤200 480mm 1
400≥DN≥250 580mm 2 DN
1200≥DN>400 680mm 1
2000≥DN>1400 880mm 4 DN
26
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
D≤400mm, H=1/2 D
D>400mm, H=1/4 D
Remarks:
Insertion depth has no relationship with pipe
thickness.For example, DN400 pipe thickness is
5mm, insertion depth should be ½ of 400mm, the L1
should be 200 mm.
FLOW
≥15D ≥10D
Upstream Downstream
27
QTLD/C Insertion Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/C X X X X X X X X X
Compact 1
Remote 2
Structure
Compact with explosion proof 3
ABS 1
Probe
Polyurethane 2
SS316L 1
Hastelloy B 2
Electrode Material
Hastelloy C 3
Others 4
20~36 VDC G
85~265 VAC E
Power Supply
9~36 VDC solar power SD
Others X
GPRS D
Square A
Transmitter
Round B
28
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/D battery-powered electromagnetic flow meter is an ideal flow
measurement device for water and wastewater systems located at remote sites.
Various signal and communication are available like, pulse, RS485, all real-time
flow data can be monitored on computer or mobile phone by GPRS. Beside flow, it
also can measure temperature or pressure. With 5 pcs of 3.6V lithium battery,
lifespan is up to 8 years, and battery can be changed when it's used up. The
transmitter shell is SS304 and the protection grade is IP68, which is available to
be buried or submerged in the water.
Industries
29
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Applications
Features
It has a long life span, standard battery can work for 3-8 Multiple network interfaces:
01 04
years, determined by the excitation current. QTLD/D has GPRS, RS485, HART
and other network communication
02 Dual power supply: it’s equipped with external power for users.
supply interface, which can be powered by external 12-
24VDC power supply, enabling users to have a variety of 05 3.6V lithium battery can be
power options. changed if its used up.
03 Multiple work mode: QTLD/D has ‘Flow Only’ mode, ‘Flow 06 Infrared remote control display and
+ Pressure’ mode, ‘Flow +Temperature’ mode for users. operation.
Technical Data
30
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
31
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Measuring Mode
Battery Symbol
Alarm Display
3
C
-0000012.78 m 30 Second Timer
Flow Rate
Percentage
3 3 3
C C C
-0000012.78 m 30 -0000012.78 m 30 -0000012.78 m 30
1.900MPa -00.050 m/s A 080.0 -00.050 m/s 1.900MPa -00.050 m/s
ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE
lnlet Temperature A
Pressure Value
Outlet Temperature B
Instantaneous Flow State transition region
Temperature Difference D
Flow Rate
lnfrared remote control receive window
Percentage Instantaneous Heat / cold Flow
Conductance Ratio Instantaneous Flow Up display measuring state paging key
Flow Rate window/LCD Active window
Percentage Down display measuring state paging
Conductance Ratio key window/LCD Active window
Flow + Pressure Mode Flow + Temperature Mode Magnetic Key Operational Position
32
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Size Flange φh N
Standard Nominal Pressure H (mm) L (mm) φA (mm) φB (mm) (mm) (mm)
mm mm
DN15 1/2" DIN PN16 315 200 95 65 14 4
DN20 3/4" DIN PN16 320 200 105 75 14 4
DN25 1" DIN PN16 325 200 115 85 14 4
DN32 1¼" DIN PN16 337 200 140 100 18 4
DN40 1½" DIN PN16 347 200 150 110 18 4
DN50 2" DIN PN16 363 200 165 125 18 4
DN65 2½" DIN PN16 380 200 185 145 18 4
DN80 3" DIN PN16 396 200 200 160 18 8
DN100 4" DIN PN16 415 250 220 180 18 8
DN125 5" DIN PN16 440 250 250 210 18 8
DN150 6" DIN PN16 473 300 285 240 22 8
DN200 8" DIN PN16 530 350 340 295 22 12
DN250 10" DIN PN16 606 450 405 355 26 12
DN300 12" DIN PN16 659 500 460 410 26 12
DN350 14" DIN PN16 715 550 520 470 26 16
DN400 16" DIN PN16 770 600 580 525 30 16
DN450 18" DIN PN16 826 600 640 585 30 20
DN500 20" DIN PN16 889 600 715 650 33 20
DN600 24" DIN PN16 1007 600 840 770 36 20
DN700 28" DIN PN16 1093 700 910 840 36 24
DN800 32" DIN PN16 1201 800 1025 950 39 24
DN900 36" DIN PN16 1301 900 1125 1050 39 28
DN1000 40" DIN PN16 1426 1000 1255 1170 42 28
33
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Communication
Process Connection
34
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/D X X X X X X X X X
Caliber size DN10-DN2000 (3/8"-80")
Compact 1
Structure
Remote 2
PTFE 1
FEP 2
PFA 3
Neoprene 4
Lining Material
Polyurethane 5
Hard Rubber 6
Ceramic 7
Others 8
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
3.6 V lithium battery 1
3.6 V lithium battery and 12~24 VDC 2
Power Supply
3.6 V lithium battery and 85~265 VAC 3
Pulse P
Signal Output RS485 R
/Communication GPRS G
4~20 mA (need external power) 4
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25,
D**
D40: DIN PN40
Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
Process Connection IT
G2" thread ball valve
Insertion
DN50 flange ball valve IF
Tri-clamp TC
Wafer W
Thread T
Flow 1
Measuring Mode Flow + Temperature 2
Flow + Pressure 3
35
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/F partially-filled flowmeter is composed of converter, flow sensor and level sensor. The user only needs to
enter the diameter of pipe, the non-full pipe flowmeter will automatically calculate the flow rate, and automatically
display the instantaneous flow, total flow, velocity, height, etc. It can measure liquid volume min 10% of full pipe. It is
especially suitable for the needs of municipal rainwater, waste water, sewage discharge and irrigation.
36
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Features
Partially filled pipe electromagnetic flow meter can measure partially filled pipe liquid flow, it is very popular in
irrigation.
Its can use solar power supply, this type is very suitable for remote areas where has no industrial power
supply.
It adopts safe and durable material, service life is longer than normal products. Normally, it can work at least 5-
10 years or longer.
And we have already got food grade certificate for its liner so it can be used for drinking water, underground
water, etc. Many drinking water companies use this type in their big size pipelines.
We use an accurate mini ultrasonic level meter for its liquid level measurement then the flow meter will record
the liquid level and use this parameter to measure liquid flow. This ultrasonic level meter's blind area is very
small and its accuracy can reach ±1mm.
Technical Data
Size DN200-DN3000 (8"-120")
Accuracy ±2.5% of reading at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Structure Remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 µS/cm
Transmitter: IP65
Protection Grade
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium
Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W
Analog 4~20mA ( load resistor 0~750Ω)
Signal Output Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication Rs485 MODBUS standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20℃~60℃
Fluid Temperature -20℃~120℃
PTFE (-20℃~150℃, DN200-DN1600)
FEP (-20℃~120℃, DN200-DN1800)
Liner Material
PFA (-20℃~160℃, DN200-DN800)
Polyurethane (-10℃~60℃, DN200-DN1600)
DIN PN10 / PN16 / PN25 / PN40 / PN64 / PN100
Flange JIS 10K / 20K / 30 K
ANSI 150# / 300# / 600#
Measuring tube: SS304
Sensor Material
Flange & housing: carbon steel (standard), SS304 / SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure 0.6Mpa, 150lb optional
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English
37
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Features
Diameter Nominal
L (mm) H (mm) φA (mm) φK (mm) n*φh (mm)
(mm) pressure
Inch
38
QTLD/F Partially-filled Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/F X X X X X X X X X
Caliber size DN200-DN3000(8"-120")
Remote 1
Structure
Remote with explosion proof 2
Neoprene 1
FEP 2
PFA 3
Lining Material PTFE 4
Polyurethane 5
Hard Rubber 6
Others 7
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply
9~36 VDC solar power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/Communication 4~20 mA + Profibus C
GPRS D
DIN D6:DIN PN6, D10: DIN PN10, D16: DIN PN16 D**
ANSI A15: ANSI 150# A**
Flange Standard
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor 2
39
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/M mini magnetic flow meter is an economical option for small pipe size
compared with other process connection, it includes transmitter and sensor, Which
enjoy the advantages of small and compact, no moving parts, maintenance-free, save
the installation space and reduce freight costs etc.The Magmeters is ideal for use in
the field of mechanical engineering and plant construction. It has DN3
/DN6/DN10/DN15 size, 4-20mA, Pulse and RS485 Modbus available.
Features
Programmable low frequency square wave field excitation, improving measurement stability and reducing
power consumption.
Implementing ‘Rate-Of-Change Limit’ technology to eliminate sharp electrical noise contained in the flow signal
and stabilize the display and outputs.
Optional real-time clock, power-failure and history data logging function, storing up to 30 days measurement
records.
40
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
Structure Compact
Process connection Thread, G1/2", 1/2"NPT, 1/2" BSP, G3/8" for DN3 and DN6 (optional)
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h,
Display Unit
mass flow unit: kg/s, kg/m, kg/h,t/s, t/m, t/h
41
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
1. Connector
2. Shell
3. Excitation Coil
4. Pole Shoe
5. Magnet Yoke
6. Bracket Plate Assembly
7. Fixed Block
8. Measuring Tube
9. Electrode-assembly
42
QTLD/M Mini Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/M X X X X X
DN3 (1/8") 1
DN6 (1/4") 2
Size
DN10 (3/8") 3
DN15 (1/2") 4
G1/2" 1
NPT 1/2" 3
BSP 1/2" 5
BSP 3/8" 6
Others 7
SS316L 1
Titanium 3
85~265 VAC E
Power Supply
16~30 VDC G
43
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
The concentration
ratio of slurry can
reach 55%, and the variation
range is usually less
than 5%
Description
Noise is common in process fluids containing solid particulates, and it can influence the measurement, our slurry
magnetic flow meter adopts square wave excitation and 25Hz/30Hz high excitation, which can eliminate
interfacerence between the sharp wave noise generated by solid particles, ensures accurate measurement of
viscous medium.
44
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Industries
Cement slurry, sludge, gypsum slurry, paper pulp, juice, syrup, ore slurry, coal slurry, etc.
Features
01 Special design grouting converter: Special converter can eliminate interfacerence between the sharp
02
wave noise generated by solid particles.
Medium concentration: the concentration of slurry can reach 55%, and the variation range is usually
03
less than 5%.
Excitation method: square wave excitation (4 kinds of square waves) impoves flow measurement
04 stability.
Excitation Frequency: 25 Hz/30 Hz excitation frequency for choose. High excitation frequency has
LCD backlight display: instantaneous flow, total flow, flow velocity, percentage flow, etc.
45
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
46
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Process Connection
Tri-clamp
Compact
Thread
Wafer
Remote Union
47
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
Diameter
Flange Pressure H(mm) L(mm) φA(mm) φB(mm) φh(mm) N(mm)
mm Inch
DN15 1/2" ANSI 150# 343 200 88.9 60.45 4 15.7
DN20 3/4" ANSI 150# 348 200 98.6 69.85 4 15.7
DN25 1" ANSI 150# 353 200 108 79.25 4 15.7
DN32 1¼" ANSI 150# 358 200 117.3 88.9 4 15.7
DN40 1½" ANSI 150# 368 200 127 98.6 4 15.7
DN50 2" ANSI 150# 388 200 152.4 120.7 4 19.1
DN65 2½" ANSI 150# 408 200 177.8 139.7 4 19.1
DN80 3" ANSI 150# 423 200 190.5 152.4 4 19.1
DN100 4" ANSI 150# 451 250 228.6 190.5 8 19.1
DN125 5" ANSI 150# 474 250 254 215.9 8 22.4
DN150 6" ANSI 150# 502 300 279.4 241.3 8 22.4
DN200 8" ANSI 150# 563 350 342.9 298.5 8 22.4
DN250 10" ANSI 150# 638 450 406.4 362 12 25.4
DN300 12" ANSI 150# 701 500 482.6 431.8 12 25.4
DN350 14" ANSI 150# 753 550 533.4 476.3 12 28.4
DN400 16" ANSI 150# 809 600 596.9 539.8 16 28.4
DN450 18" ANSI 150# 855 600 635 577.9 16 31.75
DN500 20" ANSI 150# 912 600 698.5 635 20 31.75
DN600 24" ANSI 150# 1024 600 812.8 749.3 20 35.1
48
QTLD/J Slurry Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD / J X X X X X X X X X X
Caliber size DN15-DN3000 (1/2"-120")
Compact C
Remote R
Structure
Compact with explosion proof CEP
Remote with explosion proof REP
±0.5% 1
Accuracy ±0.2% 2
Others 3
PTFE 1
FEP 2
PFA 3
Lining Material Neoprene 4
Polyurethane 5
Hard Rubber 6
Ceramic 7
SS316L 1
Hastelloy B 2
Hastelloy C 3
Electrode Material Titanium 4
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
Power Supply 85~265 VAC E
9~36 VDC solar power SD
4~20 mA + Pulse + RS485 MODBUS A
Signal Output 4~20 mA + HART B
/Communication 4~20 mA + Profitbus C
GPRS D
DIN D10: DIN PN10, D16: DIN PN16, D25: DIN PN25, D40: DIN PN40 D**
ANSI A15: ANSI 150#, A30: ANSI 300#, A60:ANSI 600# A**
Flange
JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Other O
Process Connection Insertion with G2" thread ball valve IB
Insertion
Insertion with DN50 flange ball valve IF
Tri-clamp TC
Wafer W
Thread T
IP65 Transmitter + IP65 sensor 1
Protection Grade
IP65 Transmitter + IP68 sensor (remote) 2
49
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Description
QTLD/R reduced bore electromagnetic flow meter is ideal for these applications with zero upstream or downstream
piping as they can better handle distorted velocity flow profiles arising from the pipe networks, allowing total
flexibility in installation for demanding applications compared with full bore magnetic flow meter. It can increase
velocity and flow if it’s low flow.
Industries
Sewage Treatment Plant Water
Textile Processing Industries Effluent Treatment Plant Supply Scheme
Steel & Aluminum Industries Food & Drug Industries Chemical & Fertilizer Industries
50
QTLD/D Battery-powered Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Applications
Heat Exchanger Industrial Pulp & Beverages Acidic Cooling Water Brine Solutions
& Alkaline Solution
Features
01
02
No need straight pipe in the upstream an downstream.
03
It can increase velocity and flow if it’s low flow.
04
Self-diagnosis,empty pipe alarm, exciting alarm, high and low flow alarm.
05 It has multiple output signals for choose, 4~20 mA+Pulse + RS485 Modbus are standard signal,
HART, Profibus, GPRS are optional.
51
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Technical Data
Accuracy ±0.5% of reading at flow velocity ≥0.5m/s, ±0.2% optional at flow velocity ≥0.5m/s
Repeatability ≤0.17%
Power Supply 85~250 VAC (50/60 Hz), 8~36 VDC, 3.6V lithium battery
Function High and low alarm, empty pipe alarm, exciting alarm, self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese, Italian, Portuguese, French, Spanish, Korean
52
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
DN50-DN300 Compact Reduced Bore Magnetic Flow Meter DIN PN16 Drawing
Size
Flange Nominal Pressure L (mm) D (mm) H (mm) K (mm) n*d (mm)
mm Inch (MPa)
DN50 2" DIN 1.6 200 165 374 125 4*φ18
53
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Dimension
DN50-DN300 Remote Reduced Bore Magnetic Flow Meter DIN PN16 Drawing
Size
Flange Nominal Pressure L (mm) D (mm) H (mm) K (mm) n*d (mm)
mm Inch (MPa)
DN50 2" DIN 1.6 200 165 260 125 4*φ18
54
QTLD/R Reduced Bore Electromagnetic Flow Meter
Q&T Instrument Co.,Ltd
Selection Table
QTLD/R x x x x x x x x x
Caliber size DN50-DN300 (2"-12")
Compact 1
Remote 2
Structure
Compact with explosion proof 3
Remote with explosion proof 4
±0.5% 1
Accuracy ±0.2% 2
Others 3
Neoprene 1
Lining Material
Hard Rubber 2
SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Electrode Material
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Carbon Steel 1
Sensor Material SS304 2
SS316 3
20~36 VDC G
85~265 VAC E
Power Supply
9~36 VDC solor power SD
Others X
4~20 mA + Pulse + RS485 MODBUS A
Flange ANSI A15: ANSI 150#, A30: ANSI 300#, A60: ANSI 600# A**
Standard JIS J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
55
Q&T Instrument Co.,Ltd