0% found this document useful (0 votes)
79 views

Bridge Design For Prestressed Concrete Box Section Based On AASHTO 17th Edition & ACI 318-19

This document provides a summary of the design of a prestressed concrete box bridge section based on AASHTO and ACI code standards. The summary includes the bridge dimensions, material properties, reinforcement details, prestressing details, and checks that the design satisfies serviceability and ultimate limit state requirements for stresses, crack control, and flexural capacity. The design was found to be adequate based on the code checks performed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views

Bridge Design For Prestressed Concrete Box Section Based On AASHTO 17th Edition & ACI 318-19

This document provides a summary of the design of a prestressed concrete box bridge section based on AASHTO and ACI code standards. The summary includes the bridge dimensions, material properties, reinforcement details, prestressing details, and checks that the design satisfies serviceability and ultimate limit state requirements for stresses, crack control, and flexural capacity. The design was found to be adequate based on the code checks performed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Bridge Design for Prestressed Concrete Box Section Based on AASHTO 17th Edition & ACI 318-19

INPUT DATA & DESIGN SUMMARY


BRIDGE SPAN L= 120 ft
SECTION DIMENSIONS SECTION PROPERTIES
T= 280 in, within [B , 300"] , (7112 mm) A= 15529.0 in2
B= 240 in, within [200", 280"] , (6096 mm) yt = 41.82 in
C= 110 in, within [80",180"] , (2794 mm) yb = 54.18 in
D= 96 in, within [L/15 , L/25] , (2438 mm) I= 19766329 in4
Tt = 12 in, within [8",18"] & >T/30 , (305 mm) St = 472656 in3
Tb = 24 in, within [8", 24"] & >B/30 , (610 mm) Sb = 364825 in3
W= 24 in, within [8", 24"] & >D/15 , (610 mm)
Tc = 24 in, within [14", 24"] & >C/12 , (610 mm)
Te = 6 in, (152 mm)
CONCRETE STRENGTH f 'c = 8 ksi, (55 MPa)
REBAR STRENGTH f y* = f y = 80 ksi, (552 MPa)
TENDON TENSILE STRENGTH fsu* = fpu = 270 ksi, (1862 MPa)
TENDON YIELD STRENGTH fpy = 243 ksi, (1675 MPa)
DISTANCE TO CENTROID OF COMPRESSION d' = 6 in, (152 mm)
DIST. TO CENTROID OF BOT. PRESTRESSED dp,b = 84 in, (2134 mm)
DIST. TO CENTROID OF WEB. PRESTRESSED dp,w = 76 in, (1930 mm)
DISTANCE TO CENTROID OF TENSION d= 80 in, (2032 mm)
TOP COMPRESSION REINF. 2 # 8 @ 12 in o.c., (305 mm)
BOTTOM TENSION REINF. 2 # 8 @ 12 in o.c., (305 mm)
WEB HORIZONTAL REINF. 2 # 8 @ 12 in o.c., (305 mm)
SHEAR STIRRUP REINF. 2 legs, # 10 @ 8 in o.c., (203 mm)
BOTTOM PRESTRESSING TENDONS
15 x 36 strands (each 0.5 in diameter & 0.153 in2 area )
EACH WEB PRESTRESSING TENDONS (13 mm) ( 99 mm2)
4 x 36 strands (each 0.5 in diameter & 0.153 in2 area )
TOTAL TENDON FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER 0.75 fpy, (ACI 318-19 20.3) Pi = 23088.2 kips
TOTAL TENDON FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES 0.6 fpy, (ACI 318-19 20.3) Pe = 18470.5 kips
MOMENT DUE TO SELF-WEIGHT MG = 22420.061131 ft-kips, (30398 kN-m) VERTICAL SHEAR FORCE Vu = 6886.735 kips, (30632.2 kN)
MOMENT DUE TO DEAD LOAD MD = 33750 ft-kips, (45759 kN-m) TORSIONAL MOMENT Tu = 35868.412 ft-kips, (48631 kN-m)
MOMENT DUE TO LIVE LOAD ML = 31500 ft-kips, (42708 kN-m) LATERAL BENDING MOMENT Mu,y = 41320.41 ft-kips, (56023 kN-m)
SECTION LOCATION ( 0, 1 or 2 ) 0 at midspan (Seismic/Wind Horizontal Bending Load)
PRESTRESSING METHOD ( 0, 1 or 2 ) 2 post-tensioned & bonded
EXPOSURE ( 0 OR 1 ) 0 mild exposure THE DESIGN IS ADEQUATE.

CHECK TRANSFER LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.1)


ENTIRE SECTION PRESTRESSED ECCENTRICITY
e= 38.05 in
MIN. TOP FIBER STRESS
- Fti = -0.671 ksi
MAX. BOT. FIBER STRESS
Fbi = 4.400 ksi
MAX. ALLOWABLE STRESS
Fsi = 189.000 ksi

fsi = 182.250 ksi


< Fsi
[Satisfactory]

1 e  M
f ti  P i     G  0.197 ksi > - Fti
 A St  St [Satisfactory]
(As')reqd = 0.000 in2 < (As')provd
 1 e  MG
f bi  P i     3.157 ksi < Fbi (ACI 318-19 24.4 & 24.5) [Satisfactory]
 A Sb  Sb [Satisfactory]

CHECK SERVICEABILITY LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.2)


CONCRETE DECK THICKNESS
t= 4 in
(0 for non-composite)
COMPOSITE SECTION PROPERTIES
b= 500 in
Ac = 17529.0 in2
yct = 40.82 in
ycb = 59.18 in
Ic = 23171159 in4
Sct = 567642 in3
Scb = 391537 in3
(Cont'd)
MIN. TOP FIBER STRESS MAX. BOT. FIBER STRESS
Fte = 0.6fc' = 4.800 ksi, for total loads -Fbe = -(0, 3, or 6)(fc')0.5 = -0.537 ksi
Fte, G+D = 0.4fc' = 3.200 ksi, for sustained loads only MAX. ALLOWABLE STRESS
Fte, 0.5(G+D)+L = 0.4fc' = 3.200 ksi, for live + 50% sustained loads Fse = 0.8fy = 194.400 ksi, after all losses
fse = 145.800 ksi < Fse
[Satisfactory]

 1 e  M MDML
f te  P e     G  1.556 ksi < Fte [Satisfactory]
 A St  S ct
 1 e  M MD
f te,G  D  P e     G  0.890 ksi < Fte, G+D [Satisfactory]
 A St  S ct

 1 e  0.5( M G  M D)  M L
f te,0.5(G  D) L  0.5P e      1.111 kis < Fte, 0.5(G+D)+L
 A St  S ct [Satisfactory]

 1 e  M MDML
f be  P e     G 
0.429 ksi > -Fbe [Satisfactory]
 A Sb  S cb
CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-19 20.3)
FACTORED ULTIMATE MOMENT
Mu,x = g ( bD MD + bL ML ) = 1.3 [ 1.0 ( MG + MD) + 1.67 ML] c = 0.003 0.85 f c'
(AASHTO Eq. 3-10)
A s' f s'
= 141407.579 ft-k
Mu,y = 41320.410 ft-k
Fc

Mu = (Mu,x + Mu,y )
2 2 0.5

= 147321.009 ft-k Parabolic
Mu
A ps f ps
q= 16.3 deg

COMPRESSION ZONE FACTOR


b1 = 0.65 , (ACI 318-19 22.2.2) Asfy
TENDON TYPE FACTOR
      2

gp = 0.280 , (ACI 318-19 20.3.2.3.1) 
 e f
'
C
2  c    c   , for 0   c   o  s E s , for  s   ty

RATIO OF TENSION REINF. r= 0.001 , (ACI 318-19 Chapter 2) f C
    o    o   , fS 
  f y , for  s   ty

RATIO OF COMPR. REINF. r' = 0.002 , (ACI 318-19 Chapter 2) '
 e f
 C
, for  c   o
RATIO OF PRESTR. REINF. rp = 0.006 , (ACI 318-19 Chapter 2) 
2  e f C'  f y  ty , for compression controlled

INDEX OF TENSION REINF. w= 0.013 , (ACI 318-19 20.3.2.3.1) o  ,  ty  , t  
INDEX OF COMPR. REINF. w' = 0.016 , (ACI 318-19 20.3.2.3.1)
Ec Es  ty  0.003 , for tension controlled

'
E c  57 f , E s  29000ksi ,  e  0.85 ,  cu  0.003
INDEX OF PRESTR. REINF. wp = 0.173 , (ACI 318-19 20.3.2.3.1) C

STRESS IN BONDED TENDONS : 100000

  
 p
 f pu d    '   
, 0.17   
80000

f ps  f pu 1     MIN   p ' 
fPn (k)

248.462 ksi 60000


  1   fc dp 
  
40000

STRESS IN UNBOUNDED TENDONS : 20000

0
 f 'c  Not applicable 0 20000 40000 60000 80000 100000 120000 140000 160000 180000
f ps  MIN  f se  10  , f , f  60  

 100  p y se 

-20000

-40000
 '
 fMn (ft-k) Solid Black Line - Tension Controlled
fc
f ps  MIN  f se  10  , f y, f se  30   Not applicable Solid Red Line - Transition
 300  p 
  Dash Line - Compression Controlled
f Mn = 161491 ft-kips @ Pu = 0 kips

  1 Mu
' 
e   S cb  > [Satisfactory]
1.2M cr  1.2S b  P e     7.5 f c   M G   1 
136507 ft-k < f Mn [Satisfactory]
  Ac S b    Sb 
(AASHTO 9.18.2 & ACI 318-19 18.8.2, but ACI 318-19 waived)

CHECK SHEAR CAPACITY (AASHTO 9.20, ACI 318-19 9 & 22)

d  MAX  0.8h , d p   84.00 in



f 'c  MIN 100 ,

 f 'c  provd



89.44 psi

 
   V ud p    
' ' ' 
 MAX  MIN  0.6 f c  700MIN 1 ,   b wd , 5b wd f c  , 2b wd f c  , for f se  0.4 f
 M u 
pu
7266.41 kips
Vc     
 
 '
2b wd
 f c , for f se  0.4 f pu

  d 
  A ps f puS 
 MAX  50b wS , bw 
, for f se  0.4 f
 Av f yd    fy 80 df y  pu

V s  MIN  , 8b wd f 'c   4267.20 kips Av(min)      1.400 in2


 S    
 50b wS
 , for f se  0.4 f pu
 f y

 MIN  0.75d , 24  , for V  4b d f '


 s w c
24.00 in
S max   
 MIN  0.375d , 12  , for V s  4b wd f c
'

 MIN  0.75d , 24  , for V  4b d f '
 s w c
S max   

 MIN  0.375d , 12  , for Vs  4bw d f '
c
(Cont'd)

 V c
 no shear re inf . requd , for case 1: V u  2

 V c
, for case 2 :  V u  V c
Av,requd   Av (min) 2  1.400 in2 [Satisfactory], Case 3 applicable

 MAX  Av,cal Av (min) 
, , for case 3 :  
Vc Vu   V S V c 


unsatisfactory , for case 4 :  V S  V c   V u

CHECK TORSIONAL CAPACITY (AASHTO 9.21, ACI 318-19 22.7)

Acp = 26880 in2 2 


 Acp f pc
Pcp = 752 in Tu >  f 'c   1   6093.124 ft-kips
 P cp  4 f 'c
fpc = 0.687 ksi
Aoh = 25293 in2 Thus, Torsional Reinf. Reqd.
Ph = 735 in

 5 Acp f 'c 
At Tu  At   f yv  2  f yv   25b w  
  0.020 in2/in A L  MAX   P h   cot 37.5  ,  Ph   max  At ,   85.96 in2
S 1.7 Aoh f yv cos 37.5   S   f yL   f yL  
 f yL 

S

f yv  
 

 At   2 50b w 
 MAX  Av At ,
 At 
S   0.215 in2/in <  S   0.635 in2/in
 Total  S f yv    Pr ovD
Re qD 
[Satisfactory]