Electromagnetic Flow Meter: DN3-DN3000mm / Flange Connection / Integrated Type

The document provides specifications for the Mag1100 electromagnetic flow meter, which measures liquid flow rates. Key details include: - It measures flow rates from 0.1 to 15 m/s for pipes ranging from 3 to 3000mm in diameter. - Accuracy is ±0.5% of reading or better depending on options selected, for liquids with conductivity over 20uS/cm. - Materials options include stainless steel, Hastelloy, titanium, and tantalum electrodes for use in corrosive liquids. - Inputs include 85-250VAC, 20-36VDC power, and communication via RS485, Hart, ProfiBus DP protocols. Outputs include pulse, 4-

Uploaded by

MP
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views

Electromagnetic Flow Meter: DN3-DN3000mm / Flange Connection / Integrated Type

The document provides specifications for the Mag1100 electromagnetic flow meter, which measures liquid flow rates. Key details include: - It measures flow rates from 0.1 to 15 m/s for pipes ranging from 3 to 3000mm in diameter. - Accuracy is ±0.5% of reading or better depending on options selected, for liquids with conductivity over 20uS/cm. - Materials options include stainless steel, Hastelloy, titanium, and tantalum electrodes for use in corrosive liquids. - Inputs include 85-250VAC, 20-36VDC power, and communication via RS485, Hart, ProfiBus DP protocols. Outputs include pulse, 4-

Uploaded by

MP
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Mag1100/Electromagnetic Flow Meter

DN3-DN3000mm / Flange Connection / Integrated Type

Benefit

♦ Medium temperature :-20℃~60℃.

♦ Diagnostic function and empty pipe detection.

♦ Measure forward and reverse direction flows.

♦ Built-in reference electrodes,no need to connect ground ring.

♦ Dual frequency excitation and stable zero point.

♦ Precision coil winding technology,makes magnetic field more uniform.

♦ High protection grade,IP65.

♦ No moving parts,no pressure loss.

♦ High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional,velocity >0.3 m/s.

Standard Specification

● Size : DN3-DN3000mm (1/8”~120”) ● Language : English,Spanish,Portuguese

● Accuracy :±0.5% of reading,±0.3% and Russian,Italian,French,etc

±0.2% optional,velocity >0.3 m/s ● Display : LC Display,128X128mm

● Velocity : Normal liquid >20 μS/cm, Three lines

4 internal push buttons

● Protection Grade : IP65 ● Ambient Temperature : -20℃~60℃

● Electrode : SS316L, Hastelloy C, Hastelloy B, ● Relative Humidity : 5%~95%

Titanium Tantalum, Platinum-iridium, ● Liner Material : Neoprene(Rubber)

Tungsten carbide PTFE

● Power Supply : AC85~250V, DC20V~36V PFA

● Power Consumption : <20W F46

● Communication : RS485/MODBUS,Hart,PROFIBU DP Polyurethane


● Flow Range : 0.1 m/s ~ 15 m/s Measuring Tube : Stainless Steel 304

● Working Pressure : 4.0 MPa (DN3-DN150) Flange : Carbon Steel (standard)

1.6 MPa (DN200-DN600) : Stainless Steel 304 (optional)

1.0 MPa (DN700-DN1000) : Stainless Steel 316 (optional)

0.6 MPa (DN1200-DN3000) ● Straight Pipe : Inlet Path ≥ 10D

● Flange Standard : ANSI 150#, 300#, 600# Outlet Path ≥ 5D

JIS 10K, 20K, 40K ● Certificates : CE, CQC, ISO9001

DIN PN10,PN16,PN25,PN40 ● Frequency Output : 1~5000 Hz

3 3 3
● Flow Unit : L/h, L/m, L/s, m /H, m /m, m /s
● Exciting Current : 125mA, 187mA, 250mA

● Electrode No. :3
● Exciting Frequency : 3.12Hz, 4.16Hz, 6.25Hz

2 measuring electrode
12.5Hz, 25Hz, 30Hz

1 grounding electrode
● Material

● Signal Output : 4~20 mA,pulse

Mag1100/Electromagnetic Flow Meter


DN3-DN3000mm / Flange Connection / Integrated Type

Dimension of Sensor and Converter

External
Nominal
Weight
Diameter
Dimension (mm)

mm L D Kg

3 200 90 4

6 200 90 5

10 200 90 6

15 200 95 8

20 200 105 10

25 200 115 12

32 200 140 13

40 200 150 14

50 200 165 15
65 200 185 18

80 200 200 20

100 250 235 25

125 250 270 28

150 300 300 30

200 350 340 50

250 450 405 70

300 500 460 95

350 550 520 120

400 600 580 140

450 600 640 160

500 600 715 200

600 600 840 280

700 700 895 350

800 800 1015 400

900 900 1115 480

1000 1000 1230 550

1200 1200 1405 660

1400 1400 1630 750

1600 1600 1830 850

1800 1800 2045 980

2000 2000 2265 1200

2200 2200 2475 1600

2400 2400 2685 2000

2600 2600 2905 2400

2800 2800 2905 2700

3000 3000 3315 2900


Mag1100/Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection / Integrated Type
Mag1100/Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection Type

Selection Table electromagnetic flow meter

Coil Main Board

Electrode Liner
Mag1100/Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection / Integrated Type

Installation Notice

Installed at the lowest point and vertical upward direction Install exhaust valve at the downstream of flow meter

Don’t install at the highest point and vertical downward direction when drop is more than 5m

Installed at the lowest point when used in open drain pipe Need 10D of upstream and 5D of downstream

Don’t install it at the entrance of pump, install it at the exit of pump Installed at the rising direction
Electrode Property

Applicable in water,sewage and corrosive mediums.


SS316L
Widely used in industries of petrol,chemistry,urea,etc

Stainless Steel Covered


Applicable in mediums of no corrosive and low abrasion.
with tungsten carbide

Having strong resistance to HydrochloriC acid of any concentration which is below boiling point.
Hastelloy B Also resistant against vitriol,phosphate,Hydrofluoric acid,organic acid etc,which are Oxidizing
acid,alkali and non oxidizing salt.

Be resistant to oxidizing acid such as Nitric acid,mixed acid as well as oxidizing salt such as
Hastelloy C
Fe+++,Cu++ and sea water

Applicable in seawater,and kinds of chloride,Hypochlorite salt,oxidizing acid(including Fuming Nitric


Titanium acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as Sulfuric acid,Hydrochloric
acid)corrosion.Acid contains antioxidant(such as Fe+++,Cu++)will greatly reduce corrosion.

Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all
Tantalum
chemical mediums.Except for Hydrofluoric acid,Oleum and Alkali.

Platinum-iridium Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.
Mag1100/Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection / Integrated Type

Electromagnetic Flowmeter Flow-rate Flow Range Comparison