Catalog GD200A
Catalog GD200A
GD20&GD200A Series
Vector General Purpose
Inverter Product Instruction
GD20&GD200A series inverters are new generation product of the inverter, with rich
product type and wide range of power, can be widely use to fan and water pump.
Products based on the vector V/F control, and realize the accurate parameter of
motor Auto-turning, high precision speed control. To effectively improve the reliability
of the product and the environment.
At the same time, with more rich function and more flexible application, the series
products can strengthen the customer’s easy to use.
Product Advantage
Multi-function
and easy to use
GD20 series mini type general vector inverter, positioned as using the high performance
mini product of small power market; product using the leading international vector control
algorithm, with excellent product features, compatible with wall and rail installation, and
the product volume is smaller.Product widely used in Textile machinery, Food machinery,
Plastic machinery, Printing and packaging, Environmental protection equipment, Ceramic
equipment, Woodworking equipment, Conveying equipment and so on industries.
Product Advantage
● Mini structure
● Easy maintenance
● Various installation ways
● Excellent performance
1 Mini design, smaller installation space 2 Compatible with rail and wall
installation, flexible installation
manner
Excellent Performance
Current
Current waveforms when sudden loading in V/F control Current waveforms when sudden unloading in V/F
mode with 2Hz and full load control mode with 2Hz and full load
Current waveforms when sudden loading in vector Current waveforms when sudden unloading in vector
control mode with 0.5Hz and full load control mode with 0.5Hz and full load
Current waveforms when sudden loading in vector Current waveforms when sudden unloading in vector
control mode with 0.5Hz and full load control mode with 0.5Hz and full load
5
Various protection Provide overall fault protection Protection functions such as overcurrent, overvoltage,
functions functions undervoltage, overheating, overload, can save fault information
Main Applications
Function Specification
Standard Wiring
Wiring diagram of control circuit
Type Selection
Type designation key
GD20-2R2G-4-UL
① ② ③ ④
Key No. Detailed description Detailed content
Power ratings
Key Rated output power(kW) Rated input current(A) Rated output current(A)
Installation Dimension
Wall installation
Installation dimension (unit: mm)
Rail installation
Installation dimension (unit: mm)
10
Product Advantage
● High performance
● Multi-function with simple operation
● Reliable quality certificated
11
load and frequent braking motor after braking and the situation when keep
● Big braking torque and quick braking the moment output after braking to zero speed
● Not available on the situation of big inertia load or
12
Remarks:
C2 filter: EMC performance of the inverter achieves the limited
usage requirement in civil environment.
C3 filter: EMC performance of the inverter achieves the limited
usage requirement in civil environment.
13
14
15
In the diagram above, M2 and M3 are auxiliary motors which are controlled by RO1 and RO2. PID constant-pressure
automatic control system is formed by the inverter through pressure feedback. The pressure reference can apply analog
or keypad input. 485 remote communications is also supported.
16
Remarks:
Each Goodrive200A inverter has past the test certification
AC 3PH:380V(-15%)-440V(+10%)
Wide voltage range
17
Remarks:
INVT is the only manufacturer achieved ACT certificate of TÜV SÜD .The full name of ACT is Acceptance of Client's Testing, which
means the German TÜV SÜD admit the technology level of the lab and accept their separate testing data and test reports officially.
Electric Vibration System Low Pressure Test Chamber (L) Natural Convection Test Chamber (L)
Constant Temperature and Humidity Test Thermal Shock Test Chamber (R)
Chamber (R)
18
Main Applications
19
Function Illustration
20
Standard Wiring
Wiring diagram of control circuit
21
Inverter model Rated output power (kW) Input current (A) Rated output current (A)
3-phase 220VAC±15%
GD200A-0R75G-2 0.75 5 4.5
GD200A-1R5G-2 1.5 7.7 7
GD200A-2R2G-2 2.2 11 10
GD200A-004G-2 3.7 17 16
GD200A-5R5G-2 5.5 21 20
GD200A-7R5G-2 7.5 31 30
GD200A-011G-2 11 43 42
GD200A-015G-2 15 56 55
GD200A-018G-2 18.5 71 70
GD200A-022GP-2 22 81 80
GD200A-030G-2 30 112 110
GD200A-037G-2 37 132 130
GD200A-045G-2 45 163 160
GD200A-055G-2 55 181 190
3-phase 380VAC±15%
GD200A-0R75G-4 0.75 3.4 2.5
GD200A-1R5G-4 1.5 5.0 3.7
GD200A-2R2G-4 2.2 5.8 5
GD200A-004G/5R5P-4 4/5.5 13.5/19.5 9.5/14
GD200A-5R5G/7R5P-4 5.5/7.5 19.5/25 14/18.5
GD200A-7R5G/011P-4 7.5/11 25/32 18.5/25
GD200A-011G/015P-4 11/15 32/40 25/32
GD200A-015G/018P-4 15/18.5 40/47 32/38
GD200A-018G/022P-4 18.5/22 47/56 38/45
GD200A-022G/030P-4 22/30 56/56 45/60
GD200A-030G/037P-4 30/37 70/80 60/75
GD200A-037G/045P-4 37/45 80/94 75/92
GD200A-045G/055P-4 45/55 94/128 92/115
GD200A-055G/075P-4 55/75 128/160 115/150
GD200A-075G/090P-4 75/90 160/190 150/180
GD200A-090G/110P-4 90/110 190/225 180/215
GD200A-110G/132P-4 110/132 225/265 215/260
GD200A-132G/160P-4 132/160 265/310 260/305
GD200A-160G/200P-4 160/200 310/385 305/380
GD200A-200G/220P-4 200/220 385/430 380/425
GD200A-220G/250P-4 220/250 430/485 425/480
GD200A-250G/280P-4 250/280 485/545 480/530
GD200A-280G/315P-4 280/315 545/610 530/600
GD200A-315G/350P-4 315/350 610/625 600/650
GD200A-350G/400P-4 350/400 625/715 650/720
GD200A-400G-4 400 715 720
GD200A-500G-4 500 890 860
Remarks:
(1)The input current of the inverter 0.75G-315G/350P is tested when the input voltage is 380V and there is no DC reactor and output/input reactor.
(2)The current of the inverter 350G/400P-500G is tested when the input voltage is 380V and there is input reactor.
(3)Rated output current is defined when the rated output voltage is 380V.
22
3-phase 4kW~7.5kW 191.2 151 174 11.5 370 351 324 15 196.3 113 6
220VAC 11kW~15kW 275 237 259 11 445 426 404 10 245 119 7
series
18.5kW ~30kW 270 130 261 11 445 426 404 10 245 119 7
37kW~55kW 325 200 317 58.5 680 661 626 23 363 182 9.5
0.75kW~2.2kW 150.2 115 130 7.5 234 220 190 13.5 155 65.5 5
4kW~5.5kW 170.2 131 150 9.5 292 276 260 6 167 84.5 6
7.5kW~15kW 191.2 151 174 11.5 370 351 324 15 196.3 113 6
3-phase 18.5kW 250 210 234 12 375 356 334 10 216 108 6
380VAC
series 22kW~30kW 275 237 259 11 445 426 404 10 245 119 7
37kW~55kW 270 130 261 11 445 426 404 10 245 119 7
75kW~110kW 325 200 317 58.5 680 661 626 23 363 182 9.5
132kW~200kW 500 180 480 60 870 850 796 37 358 178.5 11
23
Installation Diagram
24
18.5-30kW Wall mounting Installation diagram 132-200kW Wall mounting Installation diagram
11-15kW Flange mounting installation diagram 18-55KW Flange mounting installation diagram
25
0.75-15kW Flange mounting Installation diagram 37-110kW Flange mounting Installation diagram
18.5-30kW Flange mounting Installation diagram 132-200kW Flange mounting Installation diagram
220-315KW Floor mounting Installation diagram 350-500KW Floor mounting Installation diagram
26
Optional Parts
27
28
Filters
GD200A-0R7G-4
GD200A-2R2G-4
GD200A-004G/5R5P-4
FLT-P04016L-B FLT-L04016L-B
GD200A-5R5G/7R5P-4
GD200A-7R5G/011P-4
FLT-P04032L-B FLT-L04032L-B
GD200A-011G/015P-4
GD200A-015G/018P-4
FLT-P04045L-B FLT-L04045L-B
GD200A-018G/022P-4
GD200A-022G/030P-4
FLT-P04065L-B FLT-L04065L-B
GD200A-030G/037P-4
GD200A-037G/045P-4
FLT-P04100L-B FLT-L04100L-B
GD200A-045G/055P-4
GD200A-055G/075P-4
FLT-P04150L-B FLT-L04150L-B
GD200A-075G/090P-4
GD200A-110G/132P-4
FLT-P04250L-B FLT-L04250L-B
GD200A-132G/160P-4
GD200A-160G/185P-4
GD200A-200G/220P-4
GD200A-220G/250P-4
GD200A-280G/315P-4
GD200A-315G/350P-4
GD200A-400G-4
29
30
31