K K Wagh Polytechnic, Nashik: A. Where There Is Less Space Available

The document is about a chapter on gas insulated substations from an electrical engineering class. It discusses key aspects of gas insulated substations including why they are used where space is limited, that sulfur hexafluoride gas is used, the maximum transmission voltage in India, and that SF6 circuit breakers are preferred for high voltage applications. It also summarizes characteristics of SF6 gas and some components and benefits of gas insulated substations.

Uploaded by

Prashant Jadhav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

K K Wagh Polytechnic, Nashik: A. Where There Is Less Space Available

The document is about a chapter on gas insulated substations from an electrical engineering class. It discusses key aspects of gas insulated substations including why they are used where space is limited, that sulfur hexafluoride gas is used, the maximum transmission voltage in India, and that SF6 circuit breakers are preferred for high voltage applications. It also summarizes characteristics of SF6 gas and some components and benefits of gas insulated substations.

Uploaded by

Prashant Jadhav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

K K Wagh Polytechnic, Nashik

Department Of Electrical Engineering

Sub: - Electrical Substation Practices (22633) Class:- TY


Chapter 5:- Gas Insulated Substation
Course Outcome: - Maintain Gas insulated Substation

1. Gas Insulated Substation is employed where


a. Where there is less space available
b. For high altitude substations
c. In terrain region
d. All the above

2. Which of the gas is used in gas insulated substation


a. Nitrogen + SF6
b. Hydrogen + SF6
c. SF6
d. None of the above

3. What is the maximum transmission voltage substation in India


a. 400KV
b. 500KV
c. 750KV
d. 1000KV

4. Step potential and Touch potential is associated with


a. High voltage transmission
b. Earthing of the substation
c. Voltage rise in the substation
d. Communication systems

5. Which of the following circuit breakers is preferred for EHT application


a. Air blast circuit breakers
b. Minimum oil circuit breakers
c. Bulk oil circuit breakers
d. SF6 circuit breakers

6. SF6 gas
a. is lighter than hydrogen
b. is lighter than air
c. has density 2-times as compared to that of air
d. has density 5 limes as compared to that of air

7. SF6 is which type of gas


a. Electro positive
b. Electro negative
c. Both (a) and (b)
d. None of these

8. Why is an isolator installed

Mr. N. M. Ghogare
a. To isolate one portion of the circuit from another
b. As an substitute for the circuit breaker
c. It used on either sides of the circuit breaker
d. Both (a) and (c)

9. During arc extinction SF6 gas gets converted to which among these
a. Gets decomposed to SF4 and SF2
b. Gets decomposed to S and F
c. Gets reduced to SF6
d. Gets oxidized

10. The current chopping tendency is minimised by using SF6 gas at relatively
a. Low pressure and high viscosity
b. Low pressure and low viscosity
c. High pressure and low viscosity
d. High pressure and high viscosity

11. Neutral earthing has the advantages of


a. Elimination of arcing grounds
b. Low maintenance and operating costs over isolated neutral systems
c. simplified design of earth fault protection
d. All of the above

12. Routine tests are conducted on


a. Bulk oil circuit breakers
b. Minimum oil circuit breakers
c. Air-blast circuit breakers
d. All of the above

13. At what pressure is the SF6 gas filled in the whole installation of GIS substations
a. 3 kg / cm2
b. 5 kg / cm2
c. 3 kg / m2
e. 5 kg / m2

14. The size of Gas Insulated Substation is significantly small compared to conventional
Substation because
a. High electronegative property of SF6 gas
b. High dielectric property of SF6 gas
c. High Insulation property of SF6 gas
d. All the above

15. Earthing conductivity is affected by


a. Moisture content in the soil
b. Chemical composition
c. Concentration of salts in the soil
d. All the above

Mr. N. M. Ghogare