0% found this document useful (0 votes)
45 views

848 TX

Uploaded by

Wagner Vescovi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views

848 TX

Uploaded by

Wagner Vescovi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

Product Data Sheet

00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Rosemount 848T High Density Temperature
Measurement Family
• Innovative temperature measurement for high
density applications that provide installation
and operational savings
• Independently configurable inputs that
support RTD, thermocouple, ohm, mV, and
4–20 mA signals
• Enclosure options and intrinsically safe design
allows for installation close to any process,
including hazardous areas
• WirelessHART™ capabilities extends the full
benefits of PlantWeb® to previously
inaccessible locations

Contents
High Density Temperature Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
The Rosemount 848T Foundation fieldbus Temperature Transmitter . . . . . . . . . . . . . . . . . . page 4
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
The Rosemount 848T Wireless Temperature Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
WirelessHART... The Industry Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 27

www.rosemount.com
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

High Density Temperature Measurement


Increase performance with High Density
Transmitters
• Transmit multiple measurements with one set of
electronics
• Mount close to process to reduce sensor wire length and
increase measurement reliability
• Enhance Accuracy with EMI correction, cold junction
compensation and device diagnostics
• Reduce installation costs by as much as 70 percent

High Density Temperature Measurement


Ideal solution for taking multiple measurements in close
proximity to each other such as:
• Bearing temperature on pumps and motors
• Distillation columns
• Furnaces and boilers
• Reactors, storage tanks, and many more

Simplify Installation and Reduce Wiring Costs


• Eliminate Marshalling
• Less wire routing and fewer terminations
• Faster startups with fewer devices

Access Powerful Information with New Device


Dashboards
• Leverage Human Centered Design practices to create an
intuitive user interface
• Instantly see status and output of each sensor
• Direct links to graphical diagnostics and troubleshooting
help
• Drastically lower configuration time

2
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Smart Wireless Delivers Innovative Wireless
Solutions for Temperature Measurement
• Self-organizing network delivers information rich data

FOUNDATION
fieldbus
with >99% data reliability and establishes a highly
stable network
• WirelessHART® Internationally recognized as IEC
62591
• Emerson SmartPower™ solutions provide an
intrinsically safe Power Module, allowing field
replacements without removing the transmitter from
the process, keeping personnel safe and reducing
maintenance costs
• Emerson Process Management’s layered approach
to wireless network security ensures that data
transmissions are secure

FOUNDATION fieldbus Provides Effective


Measurements with Reduced Wiring Costs
• Internationally recognized Digital Network
(IEC 61158) supports the connection of up to 16
devices on a single twisted wire pair
• Allows advanced computations through use of
function blocks
• Provides continuous measurement status for each
measurement point
• Lower costs by reducing wiring, terminations, and
required number of I.S. Barriers

Explore the Benefits of a Complete Point


Solution from Rosemount Temperature
Measurement
• Emerson offers a selection of RTDs and
thermocouples that bring superior durability and
Rosemount reliability to temperature sensing
• A broad thermowell offering meets the demanding
requirements of a variety of process applications

Experience Global Consistency and Local


Support from Worldwide Rosemount
Temperature Manufacturing sites
• World-class manufacturing provides globally
consistent product from every factory and the
capacity to fulfill the needs of any project
• Experienced Instrumentation Consultants help select
the right products for each temperature application
• An extensive global network of Emerson service and
support personnel can be onsite when and where
they are needed

3
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

The Rosemount 848T FOUNDATION fieldbus Temperature


Transmitter
FOUNDATION
fieldbus

The Rosemount 848T offers a low cost solution for high density
measurements. The 848T accepts eight independently configurable sensor
inputs, and can be mounted close to the process to improve data quality.
FOUNDATION fieldbus architecture allows up to 128 temperature
measurements to be transmitted on a single H1 fieldbus line. Additionally,
the 848T is bus-powered, further reducing the amount of required wiring to
install the device. The robust design has proven itself in thousands of
successful installations. Capabilities include:
• Eight independently configurable inputs, including 2- and 3-wire RTDs,
thermocouples, mV, 2- and 3-wire ohms, and 4-20mA signals
• Diagnostics, including good, bad, and uncertain measurement status
• Fieldbus functionality with 8 AI blocks, 1 MAI block, 4 ISEL Blocks, and
backup LAS Capabilities
• 600 Vdc isolation and integral transient protection
Table 1. Rosemount 848T FOUNDATION fieldbus Ordering Table
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Product Description
848T High Density Temperature Measurement Family
Transmitter Output
Standard Standard
F FOUNDATION fieldbus digital signal (includes AI, MAI, and ISEL function blocks, and Backup Link Active ★
Scheduler)
Rosemount
Junction
Product Certifications(1) Box required?
Standard Standard
I1 ATEX Intrinsic Safety No ★
I4 TIIS Intrinsically Safety No ★
I5(2) FM Intrinsically Safe No ★
I6(2) CSA Intrinsically Safe No ★
I7 IECEx Intrinsic Safety No ★
IA ATEX FISCO Intrinsic Safety No ★
IE FM FISCO Intrinsically Safe No ★
IF(2) CSA FISCO Intrinsically Safe, Division 2 No ★
IG IECEx FISCO (Intrinsic Safety) No ★
N1 ATEX Type n (enclosure required) Yes ★
N5 FM Class I, Division 2, and Dust Ignition-proof (enclosure required) Yes ★
N6 CSA Class I, Division 2 No ★
N7 IECEx Type n (enclosure required) Yes ★
NC ATEX Type n Component (Ex nA nL) No(3) ★
ND ATEX Dust (enclosure required) Yes ★
NJ IECEx Type n Component (Ex nA nL) No(3) ★
NK FM Class 1, Division 2 No ★
NA No Approval No ★
Expanded
E6 CSA Explosion-proof, Dust Ignition-proof, Division 2 (JX3 enclosure required) Yes(4)

4
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Table 1. Rosemount 848T FOUNDATION fieldbus Ordering Table
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.

FOUNDATION
Options (Include with selected model number)

fieldbus
Input Types
Standard Standard
S001 RTD, Thermocouple, mV, Ohm Inputs ★
S002(5) RTDs, Thermocouple, mV, Ohm and 4–20 mA Inputs ★
Transient Protection
Standard Standard
T1 Integral Transient Protector ★
Mounting Bracket
B6 Mounting Bracket for 2-in. pipe mounting – SST bracket and bolts ★
Enclosure Options
Standard Standard
JP1 Plastic Junction Box; No Entries ★
JP2 Plastic Box, Cable Glands (9 x M20 nickel-plated brass glands for 7.5–11.9 mm unarmored cable) ★
JP3 Plastic Box, Conduit Entries (5 Plugged Holes, suitable for installing 1/2-in. NPT fittings) ★
JA1 Aluminum Junction Box; No Entries ★
JA2 Aluminum Cable Glands (9 x M20 nickel-plated brass glands for 7.5–11.9 mm unarmored cable) ★
JA3 Aluminum Conduit Entries (5 Plugged Holes, suitable for installing 1/2-in. NPT fittings) ★
JS1 Stainless Steel Junction Box; No Entries ★
JS2 Stainless Steel Box, Cable Glands (9 x M20 nickel-plated brass glands for 7.5–11.9 mm unarmored cable) ★
JS3 Stainless Steel Box, Conduit Entries (5 Plugged Holes, suitable for installing 1/2-in. NPT fittings) ★
JX3(6) Explosion-proof Box, Conduit Entries (4 Plugged Holes, suitable for installing 1/2-in. NPT fittings) ★
Software Configuration
Standard Standard
C1 Custom Configuration of Date, Descriptor, Message and Wireless Parameters (Requires CDS with Order) ★
Line Filter
Standard Standard
F5 50 Hz Line Voltage Filter ★
Calibration Certificate
Standard Standard
Q4 Calibration Certificate (3-Point Calibration) ★
Special Temperature Test
Expanded
LT Test to -60 °F (-51.1 °C)
Conduit Electrical Connector
Standard Standard
GE(7) M12, 4-pin, Male Connector (eurofast®) ★
GM(7) A size Mini, 4-pin, Male Connector (minifast®) ★
Typical Model Number: 848T F I5 S001 T1 B6 JA2

(1) Consult factory for availability.


(2) Available only with S001 option.
(3) The Rosemount 848T ordered with component approval is not approved as a stand-alone unit. Additional system certification is required.
(4) Enclosure Option JX3 must be ordered with Product Certification Code E6. (O-ring for the JX3 enclosure rated to -20 °C).
(5) S002 is only available with Product Certification N5, N6, N1, NC, NK, and NA.
(6) JX3 Explosion-proof enclosure rated to -4 °F (-20 °C).
(7) Available with no approval or Intrinsically Safe approvals only. For FM Intrinsically Safe (option code I5), install in accordance with Rosemount drawing
00848-4402.

5
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

Wiring
Rosemount 848T Sensor Wiring Diagram
FOUNDATION
fieldbus

1 2 3 1 2 3 1 2 3 1 2 3
2-wire 3-wire Thermocouples / 2-Wire RTD
RTD and RTD and Ohms and with
Ohms Ohms* Millivolts Compensation
Loop**

* Emerson Process Management provides 4-wire sensors for all


single-element RTDs. Use these RTDs in 3-wire configurations by
clipping the fourth lead or leaving it disconnected and insulated
with electrical tape.
** The transmitter must be configured for a 3-wire RTD in order to
recognize an RTD with a compensation loop.

Standard Configuration
Unless otherwise specified, the transmitter will be shipped as
follows for all eight sensors:

Standard Configuration Settings


Sensor Type(1) Thermocouple Type J
Damping(1) 5 seconds
Measurement Units(1) °C
Output(1) Linear with Temperature
Line Voltage Filter(1) 60 Hz
Temperature Specific • Sensor Transducer Block (1)
Blocks
FOUNDATION™ fieldbus • Analog Input (8)
Function Blocks • Multiple Analog Input (1)
• Input Selector (4)
Input Transient Filter(1) • Enabled

(1) For all eight sensors.

6
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Specifications
FUNCTIONAL Electromagnetic Compatibility Compliance Testing

FOUNDATION
fieldbus
• Meets the criteria under European Union Directive
Inputs 2004/108/EC
Eight independently configurable channels including combinations • Meets the criteria under IEC 61326: 2006
of 2- and 3-wire RTDs, thermocouples, mV, and 2- and 3-wire ohm
inputs. Stability
4–20 mA inputs using optional connector(s). • ±0.1% of reading or 0.1 °C (0.18 °F), whichever is greater, for
Outputs 2 years for RTDs.
• ±0.1% of reading or 0.1 °C (0.18 °F), whichever is greater, for
Manchester-encoded digital signal that conforms to IEC 61158 and
1 year for thermocouples.
ISA 50.02.

Status Self Calibration


If self-diagnostics detect a sensor burnout or a transmitter failure, The transmitter’s analog-to-digital circuitry automatically
the status of the measurement will be updated accordingly. self-calibrates for each temperature update by comparing the
dynamic measurement to extremely stable and accurate internal
Ambient Temperature Limits reference elements.
–40 to 185 °F (–40 to 85 °C)
Vibration Effect
Accuracy (Pt 100 @ reference condition: 20 °C) Transmitters are tested to high pipeline vibration specification per
±0.30 °C (±0.54 °F) For the complete list see “Accuracy” on IEC 60770-1 1999 with no effect on performance.
page 9.

Isolation Backup Link Active Scheduler (LAS)


• 600 Vdc channel to channel isolation(1). The transmitter is classified as a device link master, which means
• 10 Vdc channel to channel isolation for all operating conditions it can function as a Link Active Scheduler (LAS) if the current link
with maximum 150 meters (500 feet) of sensor lead length 18 master device fails or is removed from the segment.
AWG. The host or other configuration tool is used to download the
Power Supply schedule for the application to the link master device. In the
absence of a primary link master, the transmitter will claim the LAS
Powered over FOUNDATION fieldbus with standard fieldbus power and provide permanent control for the H1 segment.
supplies. The transmitter operates between 9.0 and 32.0 Vdc,
22 mA maximum. (Transmitter power terminals are rated
Software Upgrade in the Field
to 42.4 Vdc.)
Software for the Rosemount 848T with FOUNDATION fieldbus is
Transient Protection easy to upgrade in the field using the FOUNDATION fieldbus
The transient protector (option code T1) helps to prevent damage Common Device Software Download procedure.
to the transmitter from transients induced on the loop wiring by
FOUNDATION fieldbus Parameters
lightning, welding, heavy electrical equipment, or switch gears.
Schedule Entries 20
This option is installed at the factory for the Rosemount 848T and
Links 30
is not intended for field installation. Virtual Communications Relationships (VCR) 20
Update Time
Approximately 1.5 seconds to read all 8 inputs. PHYSICAL
Humidity Limits Mounting
0–99% non-condensing relative humidity. The Rosemount 848T can be mounted directly onto a DIN rail or it
can be ordered with an optional junction box. When using the
Turn-on Time
optional junction box, the transmitter can be mounted onto a panel
Performance within specifications is achieved in less than 30 or a 2-in. pipe stand (with option code B6).
seconds after power is applied to the transmitter.

Alarms
The AI and ISEL function blocks allow the user to configure the
alarms to HI-HI, HI, LO, or LO-LO with a variety of priority levels
and hysteresis settings.

(1) Reference conditions are -40 to 60 °C (-40 to 140 °F)


with 30 meters (100 feet) of sensor lead length 18 AWG
wire. 7
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

Entries for Optional Junction Box


No Entry
• Used for custom fittings
FOUNDATION
fieldbus

Cable Gland
• 9 x M20 nickel-plated brass glands for 7.5–11.9 mm
unarmored cable
Conduit
• 5 plugged 0.86-in. diameter holes suitable for installing 1/2-in.
NPT fittings

Materials of Construction for Optional Junction Box


Junction Box Type Paint
Aluminum Epoxy Resin
Plastic NA
Stainless Steel NA
Aluminum Explosion-proof NA

Weight
Assembly Weight
oz lb kg
Rosemount 848T only 7.5 .47 .208
Aluminum(1) 78.2 4.89 2.22
Plastic(1) 58.1 3.68 1.65
Stainless Steel (1) 77.0 4.81 2.18
Aluminum Explosion-proof 557 34.8 15.5
(1) Add 35.2 oz (2.2 lb, 0.998 kg) for nickel-plated brass glands.
Environmental Ratings
Type 4X and IP66 with optional junction box. JX3 Explosion-proof
enclosure rated to -4 °F (-20 °C).

FUNCTION BLOCKS
Analog Input (AI)
• Processes the measurement and makes it available on the
fieldbus segment.
• Allows filtering, alarming, and engineering unit changes.

Input Selector (ISEL)


• Used to select between inputs and generate an output using
specific selection strategies such as minimum, maximum,
midpoint, or average temperature.
• Since the temperature value always contains the
measurement status, this block allows the selection to be
restricted to the first “good” measurement.

Multiple Analog Input Block (MAI)


• The MAI block allows the eight AI blocks to be multiplexed
together so they serve as one function block on the H1
segment, resulting in greater network efficiency.

8
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
ACCURACY
Table 2. Input Options/Accuracy

FOUNDATION
fieldbus
Input Ranges Accuracy Over Range(s)
Sensor Option Sensor Reference °C °F °C °F
2- and 3-Wire RTDs
Pt 50 ( = 0.00391) GOST 6651-94 –200 to 550 –328 to 1022 ± 0.57 ± 1.03
Pt 100 ( = 0.00391) GOST 6651-94 –200 to 550 –328 to 1022 ± 0.28 ± 0.50
Pt 100 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.30 ± 0.54
Pt 100 ( = 0.003916) JIS 1604, 1981 –200 to 645 –328 to 1193 ± 0.30 ± 0.54
Pt 200 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.54 ± 0.98
Pt 200 ( = 0.003916) JIS 1604;  = 0.003916, 1981 –200 to 645 –328 to 1193 ± 0.54 ± 0.98
Pt 500 IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.38 ± 0.68
Pt 1000 IEC 751;  = 0.00385, 1995 –200 to 300 –328 to 572 ± 0.40 ± 0.72
Ni 120 Edison Curve No. 7 –70 to 300 –94 to 572 ± 0.30 ± 0.54
Cu 10 Edison Copper Winding No. 15 –50 to 250 –58 to 482 ± 3.20 ± 5.76
Cu 100 (a=428) GOST 6651-94 -185 to 200 -301 to 392 ± 0.48 ±0.86
Cu 50 (a=428) GOST 6651-94 -185 to 200 -301 to 392 ± 0.96 ±1.73
Cu 100 (a=426) GOST 6651-94 -50 to 200 -58 to 392 ± 0.48 ±0.86
Cu 50 (a=426) GOST 6651-94 -50 to 200 -58 to 392 ± 0.96 ±1.73
Thermocouples—Cold Junction Adds + 0.5 °C to Listed Accuracy
NIST Type B (Accuracy varies NIST Monograph 175 100 to 300 212 to 572 ± 6.00 ± 10.80
according to input range) 301 to 1820 573 to 3308 ± 1.54 ± 2.78
NIST Type E NIST Monograph 175 –200 to 1000 –328 to 1832 ± 0.40 ± 0.72
NIST Type J NIST Monograph 175 –180 to 760 –292 to 1400 ± 0.70 ± 1.26
NIST Type K NIST Monograph 175 –180 to 1372 –292 to 2502 ± 1.00 ± 1.80
NIST Type N NIST Monograph 175 –200 to 1300 –328 to 2372 ± 1.00 ± 1.80
NIST Type R NIST Monograph 175 0 to 1768 32 to 3214 ± 1.50 ± 2.70
NIST Type S NIST Monograph 175 0 to 1768 32 to 3214 ± 1.40 ± 2.52
NIST Type T NIST Monograph 175 –200 to 400 –328 to 752 ± 0.70 ± 1.26
DIN L DIN 43710 –200 to 900 –328 to 1652 ± 0.70 ± 1.26
DIN U DIN 43710 –200 to 600 –328 to 1112 ± 0.70 ± 1.26
w5Re26/W26Re ASTME 988-96 0 to 2000 32 to 3632 ± 1.60 ± 2.88
Type L GOST R 8.585-2001 -200 to 800 -328 to 1472 ± 0.71 ±1.28
Terminal Temperature -50 to 85 -58 to 185 ±0.50 ±0.90
Millivolt Input—Not approved for use with CSA Option Code I6 –10 to 100 mV ± 0.05 mV
2- and 3-Wire Ohm Input 0 to 2000 ohms ± 0.90 ohm
4–20 mA (Rosemount)(1) 4–20 mA ± 0.01 mA
4–20 mA (NAMUR)(1) 4–20 mA ± 0.01 mA
(1) Requires the S002 option code.

Differential Configuration Notes Analog Sensors 4–20mA


Differential capability exists between any two sensor types. Two types of 4–20 mA sensors are compatible with the
For all differential configurations, the input range is X to Y where Rosemount 848T. These types must be ordered with the S002
X = Sensor A minimum - Sensor B max. option code complete with an analog connector kit. The alarm
Y = Sensor A maximum - Sensor B min. levels, accuracy for each type are listed in Table 3.

Accuracy for Differential Configurations: Table 3. Analog Sensors


If sensor types are similar (for example, both RTDs or both Sensor Option Alarm Levels Accuracy
thermocouples), the accuracy = 1.5 times worst case accuracy of
4–20mA (Rosemount 3.9 to 20.8 mA ± 0.01mA
either sensor type. If sensor types are dissimilar (for example, one Standard)
RTD and one thermocouple), the accuracy = Sensor 1 Accuracy +
4–20mA (NAMUR) 3.8 to 20.5 mA ± 0.01mA
Sensor 2 Accuracy.

9
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

AMBIENT TEMPERATURE EFFECT


Transmitters may be installed in locations where the ambient temperature is between –40 and 85 °C (–40 and 185 °F).
Table 4. Ambient Temperature Effects
FOUNDATION

Accuracy per 1.0 °C (1.8 °F) Change in Ambient Temperature(1) Temperature Range (°C)
fieldbus

NIST Type
RTD
Pt 50 ( = 0.00391) • 0.004 °C (0.0072 °F) NA

Pt 100 ( = 0.00391) • 0.002 °C (0.0036 °F) NA

Pt 100 ( = 0.00385) • 0.003 °C (0.0054 °F) NA

Pt 100 ( = 0.003916) • 0.003 °C (0.0054 °F) NA

Pt 200 ( = 0.003916) • 0.004 °C (0.0072 °F) NA

Pt 200 ( = 0.00385) • 0.004 °C (0.0072 °F) NA

Pt 500 • 0.003 °C (0.0054 °F) NA

Pt 1000 • 0.003 °C (0.0054 °F) NA

Cu 10 • 0.03 °C (0.054 °F) NA

Cu 100 (a=428) • 0.002 °C (0.0036 °F) NA

Cu 50 (a=428) • 0.004 °C (.0072 °F) NA

Cu 100 (a=426) • 0.002 °C (0.0036 °F) NA

Cu 50 (a=426) • 0.004 °C (.0072 °F) NA

Ni 120 • 0.003 °C (0.0054 °F) NA

Thermocouple (R = the value of the reading)


Type B • 0.014 °C • R 1000
• 0.032 °C - (0.0025% of (R - 300)) • 300  R < 1000
• 0.054 °C - (0.011% of (R - 100)) • 100  R < 300
Type E • 0.005 °C + (0.00043% of R) • All
Type J, DIN Type L • 0.0054 °C + (0.00029% of R) • R0
• 0.0054 °C + (0.0025% of |R|) • R 0
Type K • 0.0061 °C + (0.00054% of R) • R0
• 0.0061 °C + (0.0025% of |R|) • R 0
Type N • 0.0068 °C + (0.00036% of R) • All
Type R, Type S • 0.016 °C • R  200
• 0.023 °C - (0.0036% of R) • R 200
Type T, DIN Type U • 0.0064 °C • R0
• 0.0064 °C - (0.0043% of |R|) • R 0
GOST Type L • 0.007 °C • R 0
• 0.007 °C + (0.003% of IRI) • R0
Millivolt • 0.0005 mV NA

2- and 3-wire Ohm • 0.0084 ohms NA

4–20 mA (Rosemount) • 0.0001 mA NA

4-20 mA (NAMUR) • 0.0001 mA NA

(1) Change in ambient is in reference to the calibration temperature of the transmitter (20 °C (68 °F) typical from the factory).
Ambient Temperature Notes
Examples:
When using a Pt 100 ( = 0.00385) sensor input at 30 °C ambient temperature:
• Ambient Temperature Effects: 0.003 °C x (30 - 20) = 0.03 °C
• Worst Case Error: Sensor Accuracy + Ambient Temperature Effects = 0.30 °C + 0.03 °C = 0.33 °C
• Total Probable Error 2 2
0.30 + 0.03 = 0.30C

10
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Product Certifications

FOUNDATION
HAZARDOUS LOCATIONS CERTIFICATIONS

fieldbus
North American Certifications N5 Dust Ignition-Proof
For use in Class II, III, Division 1, Groups E, F, G. Class I,
Factory Mutual (FM) Approvals Division 2, Groups A, B, C, D;
I5 Intrinsically Safe and Non-Incendive Non-incendive for Class 1, Division 2, Groups A, B, C, D when
Intrinsically Safe for use in Class I, Division 1, Groups A, B,C, installed to Rosemount Control Drawing 00848-4404.
D; when installed per Rosemount drawing 00848-4404. Rosemount Enclosure Required.
Temperature Code: Valid with both S001 and S002 options.
T4 (Tamb = –40 to 60 °C) Temperature Code:
Non-Incendive for use in Class I, Division 2, Groups A, B, C, D T4A (Tamb = –40 to 85 °C)
(suitable for use with Non-Incendive field wiring) when T5 (Tamb = –40 to 70 °C)
installed in accordance with Rosemount Drawing 00848-4404. NK Non-Incendive for use in Class I, Division 2, Groups A, B, C, D
Temperature Code: (suitable for use with Non-Incendive field wiring) when
T4A (Tamb = -40 to 85 °C) installed in accordance with Rosemount Drawing 00848-4404.
T5 (Tamb = -40 to 70 °C) Temperature Code:
Rosemount Enclosure Required. T4A (Tamb = -40 to 85 °C)
Indoor Hazardous (Classified) Locations. T5 (Tamb = -40 to 70 °C)
Table 5. FM Approved Entity Parameters Rosemount Enclosure Required.
Indoor Hazardous (Classified) Locations.
Power/Bus Sensor(1)
Vmax = 30 V VOC = 12.5 V Table 8. FM Approved Entity Parameters(1)
Imax = 300 mA ISC= 4.8 mA
Power/Bus Sensor
Pi = 1.3 W Po = 15 mW
Vmax = 42.4 V VOC = 12.5 V
Ci = 2.1 nF CA = 1.2 F
Ci = 2.1 F ISC = 4.8 mA
Li = 0 LA = 1 H
(1) Entity parameters apply to entire device, not individual sensor channels. Li = 0 H Po = 15 mW
CA = 1.2 F
Table 6. Entity Parameters for Non Incendive Field Wiring
Power/Bus Sensor(1) LA = 1 H

Vmax = 42.4 V VOC = 12.5 V (1) Intrinsically safe and non-incendive parameters
Ci = 2.1nF ISC = 4.8 mA
Li = 0 Po = 15 mW Canadian Standards Association (CSA) Approvals
CA = 1.2 F E6 Explosion-Proof and Dust Ignition-Proof
LA = 1 H Class I, Division 1, Groups B, C, and D.
(1) Entity parameters apply to entire device, not individual sensor channel. Class II, Division 1, Groups E, F, and G.
Class III
IE FISCO (Fieldbus Intrinsically Safe Concept) Intrinsic Safety Must be installed in enclosure option JX3.
Intrinsically safe for use in Class I, Division 1, Groups A, B,C, Install per drawing 00848-1041.
D; when installed in accordance with Rosemount Drawing Conduit seal not required.
00848-4404. Suitable for use in Class I, Division 2, Groups A, B, C, D. when
Temperature Code: installed per Rosemount drawing 00848-4405.
T4 (Tamb = –40 to 60 °C) Temperature Code:
Non-incendive for use in Class I, Division 2, Groups A, B, C, D T3C = (– 50 Tamb  60 °C)
(suitable for use with non-incendive field wiring); when Must be installed in a suitable enclosure as determined
installed in accordance with Rosemount Drawing 00848-4404. acceptable by the local inspection authority.
Temperature Code: I6 Intrinsically Safe, Division 2
T4A (Tamb = –40 to 85 °C) For use in Class I, Division 1, Groups A, B, C, D; when
T5 (Tamb = –40 to 70 °C) installed per Rosemount drawing 00848-4405.
Temperature Code:
Table 7. Entity Parameters T3C (Tamb = –50 to 60 °C)
Power/Bus Sensor(1) Suitable for Class I, Division 2, Groups A, B, C, D. Rated 42.4
VDC max. Not valid with S002 option.
Vmax = 17.5 V VOC = 12.5 V
Imax = 380 mA ISC = 4.8 mA
Pi = 5.32 W Po = 15 mW
Ci = 2.1nF CA = 1.2 F
Li = 0 LA = 1 H
(1) Entity parameters apply to entire device, not individual sensor
channels.
11
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

Table 9. CSA Approved Entity Parameters European Certifications


Power/Bus Sensor(1)
Vmax = 30 V VOC = 12.5 V
ATEX Approvals
FOUNDATION

I1 Intrinsic Safety
fieldbus

Imax = 300 mA ISC = 4.8 mA


Certification Number: Baseefa09ATEX0093X
Ci = 2.1nF Po = 15 mW
ATEX Marking II 1 G
Li = 0 CA = 1.2 F Ex ia IIC T4 (Tamb = –50 to 60 °C)
LA = 1 H 1180
(1) Entity parameters apply to entire device, not individual sensor Table 11. ATEX Approved Entity Parameters
channels.
Power/Bus Sensor(1)
IF FISCO (Intrinsically Safe) Ui = 30 V Uo = 12.5 V
For use in Class I, Division 1, Groups A, B, C, D; when Ii = 300 mA Io = 4.8 mA
installed per Rosemount drawing 00848-4405.
Pi = 1.3 W Po = 15 mW
Temperature Code:
Ci = 0 Ci = 1.2 F
T3C (Tamb = –50 to 60 °C)
Suitable for Class I, Division 2, Groups A, B, C, D.Rated 42.4 Li = 0 Li = 1 H
VDC max. Not valid with S002 option. (1) Entity parameters apply to entire device, not individual sensor
channels.
Table 10. CSA Approved Entity Parameters
Power/Bus Sensor(1) SPECIAL CONDITIONS FOR SAFE USE (X):
Ui = 17.5 V VOC = 12.5 V 1. This apparatus must be installed in an enclosure which affords
it a degree of protection of at least IP20. Non-metallic
Ii = 380 mA ISC = 4.8 mA
enclosures must have a surface resistance of less than 1
Pi = 5.32 W Po = 15 mW
Gohm. Light alloy or zirconium enclosures must be protected
Ci = 2.1nF Ca = 1.2 F from impact and friction when installed.
Li = 0 La = 1 H 2. The apparatus will not meet the 500 Vrms isolation test
(1) Entity parameters apply to entire device, not individual sensor
required by Clause 6.4.12 in EN 60079-11:2007. This must be
channels. taken into account when installing the apparatus.

N6 Class I, Division 2 IA FISCO (Fieldbus Intrinsically Safe Concept) Intrinsic Safety


Suitable for use in Class I, Division 2, Groups A, B, C, D. when Certificate Number: BASEEFA09ATEX0093X
installed per Rosemount drawing 00848-4405. ATEX Marking II 1 G
Temperature Code: Ex ia IIC T4 (Tamb = –50 to 60 °C)
T3C = (–50 Ta  60 °C) 1180
Must be installed in a suitable enclosure as determined
Table 12. ATEX Approved Entity Parameters
acceptable by the local inspection authority.
Power/Bus Sensor
Ui = 17.5 V Uo = 12.5 V
Ii = 380 mA Io = 4.8 mA
Pi = 5.32 W Po = 15 mW
Ci = 0 Ci = 1.2 F
Li = 0 Li = 1 H
SPECIAL CONDITIONS FOR SAFE USE (X):
1. This apparatus must be installed in an enclosure which affords
it a degree of protection of at least IP20. Non-metallic
enclosures must have a surface resistance of less than 1
Gohm. Light alloy or zirconium enclosures must be protected
from impact and friction when installed.
2. The apparatus will not meet the 500 V rms isolation test
required by Clause 6.4.12 in EN 60079-11:2007. This must be
taken into account when installing the apparatus.

12
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
NE ATEX TYPE ‘n’ APPROVAL SPECIAL CONDITIONS FOR SAFE USE (X):
Certification Number: BASEFFA09ATEX0095X 1. The component must be housed in a suitable certified
ATEX Marking II 3 G enclosure that provides a degree of protection of at least IP54
Ex nA nL IIC T5 (Tamb = –40 to 65 °C) and meets the relevant material and environmental

FOUNDATION
fieldbus
requirements of EN 60079-0, and EN-60079-15.
Table 13. ATEX Approved Entity Parameters 2. Provisions shall be made, external to the apparatus, to prevent
Power/Bus Sensor the rated voltage (42.4 Vdc) being exceeded by transient
disturbances of more than 40%.
Ui = 42.4 Vdc Uo = 5 Vdc
3. The electrical circuit is connected directly to earth: this must be
Ci = 0 Io = 2.5 mA
taken into account when installing the apparatus.
Li = 0 Co = 1000 F
Lo = 1 H
ND ATEX Dust Ignition Proof
SPECIAL CONDITIONS FOR SAFE USE (X): Certification Number: BAS01ATEX1315X
1. Provisions shall be made, external to the apparatus to prevent ATEX Marking II 1 D
the rated voltage (42.4 Vdc) from being exceeded by transient T90C (Tamb = – 40 to 65 °C) IP66
disturbances of more than 40%.
2. The ambient temperature range of use shall be the most SPECIAL CONDITIONS FOR SAFE USE (X):
restrictive of the apparatus, cable gland, or blanking plug. 1. The user must ensure that the maximum rated voltage and
current (42.4 Vdc, 22 mA) are not exceeded. All connections to
other apparatus or associated apparatus shall have control
NOTE:
over this voltage and current equivalent to a category “ib”
NE is valid with S001 Input Type ONLY
circuit according to EN 60079-11:2007.
2. Component approved Ex e cable entries must be used which
N1 ATEX Type n maintain the ingress protection of the enclosure to at least
Certification Number: Baseefa09ATEX0095X IP66.
ATEX Marking II 3 G
3. Any unused cable entry holes must be filled with component
Ex nL IIC T5 (Tamb = –40 to 65 °C)
approved Ex e blanking plugs.
Table 14. Entity Parameters 4. The ambient temperature range of use shall be the most
restrictive of the apparatus, cable gland, or blanking plug.
Power/Bus Sensor
Ui = 42.4 Vdc Uo = 12.5 Vdc
Ci = 0 Io = 4.8 mA
Li = 0 Po = 15 mW
Co = 1.2 F
Lo = 1 H

SPECIAL CONDITIONS FOR SAFE USE (X):


1. Provisions shall be made, external to the apparatus, to prevent
the rated voltage of the apparatus supply is not exceeded by
transient disturbances of more than 40%
2. The electrical circuit is connected directly to earth; this must be
taken into account when installing the apparatus.

NC ATEX Type n Component


Certification Number: Baseefa09ATEX0094U
ATEX Marking II 3 G
Ex nA nL IIC T4 (Tamb = –50 to 85 °C)
Ex nA nL IIC T5 (Tamb = –50 to 70 °C)

NOTE:
NC IS VALID WITH S001 INPUT TYPE ONLY

13
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

IECEx Certifications SPECIAL CONDITIONS OF SAFE USE:


1. The component must be housed in a suitable component
I7 IECEx Intrinsic Safety
certified enclosure that provides a degree of protection of at
Certificate No.: IECExBAS09.0030X
least IP54 and meets the relevant material and environmental
FOUNDATION

Ex ia IIC T4 (Tamb = –50 to 60 °C)


fieldbus

requirements of IEC 60079-0: 2004 & IEC 60079-15: 2005.


Table 15. IECEx Approved Entity Parameters 2. Provision must be made, external to the component, to ensure
the rated voltage of the component supply is not exceeded by
Power/Bus Sensor
transient disturbances of more than 40%.
Ui = 30 V Uo = 12.5 V
3. The electrical circuit is connected directly to earth; this must be
Ii = 300 mA Io = 4.8 mA
taken into account when installing the component.
Pi = 1.3 W Po = 15 mW
Ci = 2.1 F Ci = 1.2 F
NJ IECEx Type n COMPONENT Approval
Li = 0 Li = 1 H
Certification Number: IECExBAS09.0031U
SPECIAL CONDITIONS OF SAFE USE (X): EEx nA nL IIC T4 (Tamb = -50 to 85 °C)
1. The apparatus must be installed in an enclosure that provides EEx nA nL IIC T5 (Tamb = -50 to 70 °C)
a degree of protection of at least IP20. Non-metallic enclosures
must be suitable to prevent electrostatic hazards and light alloy NOTE:
or zirconium enclosures must be protected from impact and NJ is valid with S001 and S002 Input Types
friction when installed.
2. The apparatus is not capable of withstanding the 500 V Table 18. IECEx Approved Entity Parameters
isolation test required by IEC 60079-11: 2006 clause 6.3.12. Power/Bus Sensor
This must be taken into account when installing the apparatus.
Ui = 42.4 Vdc Uo = 5 Vdc
Ci = 0 Io = 2.5 mA
IG IECEx FISCO
Li = 0 Co = 1000 F
Certificate No.: IECExBAS09.0030X
Lo = 1000 mH
Ex ia IIC T4 (Tamb = – 50 to 60 °C)
SPECIAL CONDITIONS OF SAFE USE:
Table 16. IECEx Approved Entity Parameters
1. The component must be housed in a suitable component
Power/Bus Sensor certified enclosure that provides a degree of protection of at
Ui =17.5 V Uo = 12.5 V least IP54 and meets the relevant material and environmental
Ii = 380 mA Io = 4.8 mA requirements of IEC 60079-0: 2004 & IEC 60079-15: 2005.
Pi = 5.32 W Po = 15 mW 2. Provision must be made, external to the component, to ensure
Ci = 2.1 F Ci = 1.2 F the rated voltage of the component supply is not exceeded by
Li = 0 Li = 1 H transient disturbances of more than 40%.
3. The electrical circuit is connected directly to earth; this must be
SPECIAL CONDITIONS OF SAFE USE (X): taken into account when installing the component.
1. The apparatus must be installed in an enclosure that provides
a degree of protection of at least IP20. Non-metallic enclosures
must be suitable to prevent electrostatic hazards and light alloy
or zirconium enclosures must be protected from impact and
friction when installed.
2. The apparatus is not capable of withstanding the 500 V
isolation test required by IEC 60079-11: 2006 clause 6.3.12.
This must be taken into account when installing the apparatus.

N7 IECEx Type n Approval


Certificate No.” IECExBAS09.0032X
Ex Na nL IIC T5 (Tamb = – 40 to 65 °C)

NOTE:
N7 is valid with S001 and S002 Input Types

Table 17. IECEx Approved Entity Parameters


Power/Bus Sensor
Ui = 42.4 Vdc Uo = 5 Vdc
Ci = 0 Io = 2.5 mA
Li = 0 Co = 1000 F
Lo = 1000 mH

14
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Dimensional Drawings

FOUNDATION
Junction Boxes with no entries (option codes JP1, JA1, and JS1) – external dimensions are the same as those

fieldbus
outlined for the other junction box materials in this section.

Rosemount 848T

Top View 3-D View Side View


1.7
Security Switch Simulation Switch (43)
6.7
(170)

3.7
(93)

Removable Wiring
Connection

Dimensions are in inches (millimeters)

Aluminum/Plastic Junction Box—Cable Gland (option codes JA2 and JP2)

Top View 3-D View


10.24 (260)

Ground Screw

Side View
Front View
2.44 (62) 7.84 (199.2)
1.57 (40)
1.73 (44) 6.30 (160)
4.41 (112)

2.28 (58)
3.78 (96)
1.10 (28)

Dimensions are in inches (millimeters)

15
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

Stainless Steel Junction Box—Cable Gland (option code JS2)


FOUNDATION

Top View 3-D View


fieldbus

9.91 (231)

7.7 (196)

Ground Screw

Front View Side View

1.8 (46) 9.14 (232.2)


1.1 (28) 7.72 (196)
1.73 (44)
6.61 (168)

4.0 (102)
2.4 (62)
1.8 (47)
1.2 (30)

Dimensions are in inches (millimeters)

Aluminum/Plastic Junction Box—Conduit Entry (option codes JA3 and JP3)

Top View 3-D View


10.2 (260)

Front View Side View


157 (40)
2.44 (62)
10.2 (260)

3.5 (89)

1.7 (42)

Five Plugged 0.86-in. diameter


holes suitable for installing 1/2-in.
NPT fittings
Dimensions are in inches (millimeters)

16
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Stainless Steel Junction Box—Conduit Entry (option code JS3)

Top View 3-D View

FOUNDATION
fieldbus
9.1 (231)
7.7 (196)

Ground Screw

Front View
1.4 (35) Side View
1.1 (27) 2.8 (70) 1.2 (30)

4.0 (102)
2.4 (62)
1.6 (42) 1.8 (4.7)
0.06 (1.5)
Five Plugged 0.86-in. diameter holes suitable for installing 1/2-in. NPT fittings
Dimensions are in inches (millimeters)

MOUNTING OPTIONS
Aluminum/Plastic Junction Box Stainless Steel Junction Box
(styles JA and JP) (style JS)
Front View Side View Front View Side View

10.2 4.7
5.1 (260) 6.6 (167) fully
(130) assembled (119)

7.5 (190) fully


assembled

Dimensions are in inches (millimeters)

Aluminum/Plastic Junction Box Stainless Steel Junction Box


Mounted on a Vertical Pipe Mounted on a Vertical Pipe

17
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

The Rosemount 848T Wireless Temperature Transmitter


The Rosemount 848T is the premier choice for Wireless High Density
measurements. Four independently configurable inputs are transmitted
through WirelessHART. Revisions 3 and higher offer voltage inputs up to
1000 mV, allowing for expanded voltage measuring capabilities.Costs per
point are dramatically reduced through the use of smart wireless networks,
with the same reliability and security of wired solutions. Additionally, the
field hardened enclosure is suitable for installation in IS areas. Capabilities
WirelessHART

include:
• Four independently configurable inputs, including 2-,3-,and 4-wire
RTDs, thermocouples, mV, 2-, 3-, and 4-wire ohm, and 4-20mA signals
• Intrinsically safe, long lasting Power Module, which utilizes Emerson’s
SmartPower™ Technology
• Configurable high and low alerts to improve process performance
• Easy to use Device Dashboard, used to configure, monitor, and
troubleshoot the 848T Wireless
Table 19. Rosemount 848T Wireless Transmitter Ordering Table
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Product Description
848T High Density Temperature Measurement Family
Transmitter Output
Standard Standard
X Wireless ★
Product Certifications
Standard Standard
I1 ATEX Intrinsic Safety ★
I5 FM Intrinsically Safe ★
I6 CSA Intrinsically Safe ★
I7 IECEx Intrinsic Safety ★
N5 FM Class I, Division 2, and Dust Ignition-proof (enclosure required) ★
N6 CSA Class I, Division 2 ★
NA No Approval ★
Input Type
Standard Standard
S001 RTD, Thermocouple, mV, Ohm Inputs ★
S002(1) RTD, Thermocouple, mV, Ohm and 4–20 mA Inputs ★

Options (Include with selected model number)


Wireless Burst Rate, Operating Frequency and Protocol
Standard Standard
WA3(2) User Configurable Burst Rate, 2.4 GHz DSSS WirelessHART ★
Omnidirectional Wireless Antenna and SmartPower
WK1(3) Long Range, Integral Antenna, Power Module Adapter, Intrinsically Safe (Power Module separate) ★
WM1(3) Extended Range, Integral Antenna, Power Module Adapter, Intrinsically Safe (Power Module separate) ★
Mounting Bracket
Standard Standard
B6 Mounting Bracket for 2-in. pipe mounting - SST bracket and bolts ★
Enclosure Options
Standard Standard
HA1(4) Aluminum with Cable Glands (5 x 1/2-in. NPT for 7.5 - 11.9 mm) ★
HA2(4) Aluminum with Conduit Entries (5 plugged holes, suitable for installing 1/2-in. NPT fittings) ★

18
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Table 19. Rosemount 848T Wireless Transmitter Ordering Table
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Software Configuration
Standard Standard
C1 Custom Configuration of Date, Descriptor, Message and Wireless Parameters (Required CDS with order) ★
Line Filter
Standard Standard
F5 50 Hz Line Voltage Filter ★
5-Point Calibration
Expanded

WirelessHART
C4 5-Point Calibration (Requires Q4 option code to generate a Calibration Certificate)
Calibration Certificate
Standard Standard
Q4 Calibration Certificate (3-Point Calibration) ★
Typical Model Number: 848T X I5 S001 WA3 WK1 B6 HA1

(1) Only available with product certifications NA and N5. Stable resistors included.
(2) Required for wireless.
(3) WK1 or WM1 required for wireless
(4) HA1 or HA2 required for wireless.

19
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

WirelessHART... The Industry Standard


Self-Organizing, Adaptive Mesh Routing
• No wireless expertise required, devices
automatically find the best communication
paths
• Network continuously monitors paths for
degradation and repairs itself
• Adaptive behavior provides reliable, hands-off
WirelessHART

operation and simplifies network deployments,


expansion and reconfiguration
• Supports both star and mesh topologies
Industry Standard Radio with Channel Hopping
• Standard IEEE 802.15.4 radios
• 2.4 GHz ISM band sliced into 16
radio-channels
• Continually “hop” across channels to avoid
interference and increase reliability
• Frequency hopping spread spectrum (FHSS)
technology delivers high reliability in
challenging radio environment
Self-Healing Network
• If an obstruction is introduced into the mesh
network, devices will automatically find the
best alternate communication path
• This allows the network to instantly change to
the new path without any loss in data
Seamless Integration to Existing Hosts
• Transparent and seamless integration
• Same control system applications
• Gateways connect using industry protocols

20
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Specifications
Functional Specifications Physical Specifications
Input Electrical Connections
Four independently configurable input channels that supports Power Module
Thermocouple, RTD, mV, ohm, and 4–20 mA input types. See Field replaceable, keyed connection eliminates the risk of incorrect
“Accuracy” on page 23 for sensor options. installation. Intrinsically Safe Lithium-thionyl chloride Power
Module with polybutadine terephthalate (PBT) enclosure. Six-year
Output life at one minute update rate.(1)

WirelessHART
WirelessHART 2.4 GHz DSSS. Sensor Terminals
Sensor terminals permanently fixed to terminal block
Ambient Temperature Limits
–40 to 85 °C (–40 to 185 °F) HART Communicator Connections
Communication Terminals
Humidity Limits Clips permanently fixed to terminal block
0–99% non-condensing relative humidity
Materials of Construction
Update Rate Enclosure
User selectable, 4 sec to 60 min.
Housing - Low-copper aluminum
Paint - Polyurethane
Accuracy (Pt 100 @ reference condition: 20 °C) Cover O-ring - Silicone
±0.30 °C (±0.54 °F) For the complete list see “Accuracy” on
Terminal Block and Power Module
page 23.
PBT
Isolation Antenna
PBT/Polycarbonate (PC) integrated omnidirectional antenna
Isolation between all sensor channels is rated to 10 Vdc over all
operating conditions. No damage will occur to the device with up to
Mounting
250 Vdc between any sensor channels.
Transmitter can panel mounted, or be mounted onto a 2-in. pipe
Alerts stand (with option code B6). Sensors must be remotely mounted,
as transmitter conduit entries are not designed for direct sensor
Message sent when open or short sensor is detected.
mounting.

ElectroMagnetic Compatibility (EMC) Weight


• Meets the criteria under European Union Directive 848T Wireless - 4.75 lbs. (2.15 kg)
2004/108/EC
• Meets all relevant requirements of EN 61326. Enclosure Ratings (848T Wireless)
Housing option codes HA1 or HA2 are Type 4x and IP66.
Transmitter Stability
• ±0.15% of reading or 0.15 °C (0.27 °F), whichever is greater,
for 2 years for RTDs.
• ±0.15% of reading or 0.15 °C (0.27 °F), whichever is greater,
for 1 year for thermocouples.

Self Calibration
The analog-to-digital measurement circuitry automatically
self-calibrates for each temperature update by comparing the
dynamic measurement to extremely stable and accurate internal
reference elements.

Vibration Effect
Tested to high pipeline vibration specifications per IEC 60770-1
1999 with no effect on performance.
(1) Reference conditions are 68 °F (20 °C), and routing
data for three additional network devices.
NOTE: Continuous exposure to ambient temperature
limits (-40 °F or 185 °F) (-40 °C or 85 °C) may reduce
specified life to less than 20 percent.

21
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

Sensor Connections

848T Wireless Sensor Connections Diagram

1 1
2 2
3 3
4 4
5 5

2-wire RTD and  3-wire RTD and 


WirelessHART

1 1
+

2 2
3 3
-

4 4
5 5

4-wire RTD and  Thermocouple and mV

22
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
ACCURACY
Table 20. Input Options/Accuracy
Input Ranges Accuracy Over Range(s)
Sensor Option Sensor Reference °C °F °C °F
2-, 3-, and 4-Wire RTDs
Pt 50 ( = 0.00391) GOST 6651-94 –200 to 550 –328 to 1022 ± 0.57 ± 1.03
Pt 100 ( = 0.00391) GOST 6651-94 –200 to 550 –328 to 1022 ± 0.28 ± 0.50
Pt 100 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.30 ± 0.54
Pt 100 ( = 0.003916) JIS 1604, 1981 –200 to 645 –328 to 1193 ± 0.30 ± 0.54
Pt 200 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.54 ± 0.98

WirelessHART
PT 200 ( = 0.003916) JIS 1604, 1981 ( = 0.003916) –200 to 645 –328 to 1193 ± 0.54 ± 0.98
Pt 500 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 850 –328 to 1562 ± 0.38 ± 0.68
Pt 1000 ( = 0.00385) IEC 751;  = 0.00385, 1995 –200 to 300 –328 to 572 ± 0.40 ± 0.72
Ni 120 Edison Curve No. 7 –70 to 300 –94 to 572 ± 0.30 ± 0.54
Cu 10 Edison Copper Winding No. 15 –50 to 250 –58 to 482 ± 3.20 ± 5.76
Cu 100 (a=428) GOST 6651-94 -185 to 200 -301 to 392 ± 0.48 ±0.86
Cu 50 (a=428) GOST 6651-94 -185 to 200 -301 to 392 ± 0.96 ±1.73
Cu 100 (a=426) GOST 6651-94 -50 to 200 -58 to 392 ± 0.48 ±0.86
Cu 50 (a=426) GOST 6651-94 -50 to 200 -58 to 392 ± 0.96 ±1.73
Thermocouples—Cold Junction Adds + 0.5 °C to Listed Accuracy
NIST Type B (Accuracy varies NIST Monograph 175 100 to 300 212 to 572 ± 6.00 ± 10.80
according to input range) 301 to 1820 573 to 3308 ± 1.54 ± 2.78
NIST Type E NIST Monograph 175 –200 to 1000 –328 to 1832 ± 0.40 ± 0.72
NIST Type J NIST Monograph 175 –180 to 760 –292 to 1400 ± 0.70 ± 1.26
NIST Type K NIST Monograph 175 –180 to 1372 –292 to 2502 ± 1.00 ± 1.80
NIST Type N NIST Monograph 175 –200 to 1300 –328 to 2372 ± 1.00 ± 1.80
NIST Type R NIST Monograph 175 0 to 1768 32 to 3214 ± 1.50 ± 2.70
NIST Type S NIST Monograph 175 0 to 1768 32 to 3214 ± 1.40 ± 2.52
NIST Type T NIST Monograph 175 –200 to 400 –328 to 752 ± 0.70 ± 1.26
DIN L DIN 43710 –200 to 900 –328 to 1652 ± 0.70 ± 1.26
DIN U DIN 43710 –200 to 600 –328 to 1112 ± 0.70 ± 1.26
w5Re/W26Re ASTME 988-96 0 to 2000 32 to 3632 ± 1.60 ± 2.88
Type L GOST R.8.585-2001 –200 to 800 –328 to 1472 ±0.71 ±1.28
Terminal Temperature -50 to 85 -58 to 185 ±3.50 ±6.30
Input Units
Ohm Input 0 to 2000 ohms ±0.90 ohms
Millivolt Input -10 to 100 mV ±0.05 mV
1000 mV input -10 to 1000 mV ±1.0 mV
4–20 mA (Rosemount)(1) 4–20 mA ±0.01 mA
4–20 mA (NAMUR)(1) 4–20 mA ±0.01 mA
(1) Requires the S002 option code.

Analog Sensors 4–20mA


Two types of 4–20 mA sensors are compatible with the
Rosemount 848T. These types must be ordered with the S002
option code complete with an analog connector kit. The alarm
levels, accuracy for each type are listed in Table 3.

Table 21. Analog Sensors


Sensor Option Alarm Levels Accuracy
4–20mA (Rosemount 3.9 to 20.8 mA ± 0.01mA
Standard)
4–20mA (NAMUR) 3.8 to 20.5 mA ± 0.01mA

23
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

AMBIENT TEMPERATURE EFFECT


Transmitters may be installed in locations where the ambient temperature is between –40 and 85 °C (–40 and 185 °F).

Table 22. Ambient Temperature Effects


NIST Type Accuracy per 1.0 °C (1.8 °F) Change in Ambient Temperature(1) Temperature Range (°C)
RTD
Pt 50 ( = 0.003910) • 0.004 °C (0.0072 °F) NA

Pt 100 ( = 0.00391) • 0.002 °C (0.0036 °F) NA

Pt 100 ( = 0.00385) • 0.003 °C (0.0054 °F) NA


WirelessHART

Pt 100 ( = 0.003916) • 0.003 °C (0.0054 °F) NA

Pt 200 ( = 0.00385) • 0.004 °C (0.0072 °F) NA

PT 200 ( = 0.003916) • 0.004 °C (0.0072 °F) NA

Cu 10 • 0.03 °C (0.054 °F) NA

Pt 500 • 0.003 °C (0.0054 °F) NA

Pt 1000 • 0.003 °C (0.0054 °F) NA

Cu 100 (a=428) • 0.002 °C (0.0036 °F) NA

Cu 50 (a=428) • 0.004 °C (.0072 °F) NA

Cu 100 (a=426) • 0.002 °C (0.0036 °F) NA

Cu 50 (a=426) • 0.004 °C (.0072 °F) NA

Ni 120 • 0.003 °C (0.0054 °F) NA

Thermocouple (R = the value of the reading) NA


Type B • 0.014 °C • R 1000
• 0.032 °C - (0.0025% of (R - 300)) • 300  R < 1000
• 0.054 °C - (0.011% of (R - 100)) • 100  R < 300
Type E • 0.005 °C + (0.00043% of R) • All
Type J, Din Type L • 0.0054 °C + (0.00029% of R) • R0
• 0.0054 °C + (0.0025% of |R|) • R 0
Type K • 0.0061 °C + (0.00054% of R) • R0
• 0.0061 °C + (0.0025% of |R|) • R 0
Type N • 0.0068 °C + (0.00036% of R) • All
Type R, Type S • 0.016 °C • R  200
• 0.023 °C - (0.0036% of R) • R 200
Type T, DIN Type U • 0.0064 °C • R0
• 0.0064 °C - (0.0043% of |R|) • R 0
GOST Type L • 0.007 °C • R 0
• 0.007 °C + (0.003% of IRI) • R0
Input Units
Ohm input • 0.0084 ohms NA

100 mV Input • 0.0005 mV NA

1000 mV Input • 0.005 mV NA

4–20 mA (Rosemount) • 0.0001 mA NA

4–20 mA (NAMUR) • 0.0001 mA NA

(1) Change in ambient is in reference to the calibration temperature of the transmitter (20 °C (68 °F) typical from the factory).

Ambient Temperature Notes


Examples:
When using a Pt 100 ( = 0.00385) sensor input at 30 °C ambient temperature, temperature effects would be:
• Ambient Temperature Effects: 0.003 °C x (30 - 20) = 0.03 °C
• Worst Case Error: Sensor Accuracy + Ambient Temperature Effects = 0.30 °C + 0.03 °C = 0.33 °C
• Total Probable Error 2 2
0.30 + 0.03 = 0.30C

24
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Product Certifications
Approved Manufacturing Locations Hazardous Locations Certificates
Rosemount Inc. – Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. - Karlstein, Germany North American Certifications
Emerson Process Management Asia Pacific Private Limited - Factory Mutual (FM) Approvals
Singapore I5 FM Intrinsic Safety and Non-incendive
Intrinsically Safe for Class I, Division 1, Groups A, B, and C.
European Union Directive Information Zone Marking: Class I, Zone 0, AEx ia llC
Temperature Codes T4 (Tamb = -50 to 70 °C)
The EC declaration of conformity for all applicable European

WirelessHART
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
directives for this product can be found at www.rosemount.com. A
Intrinsically Safe and non-incendive when installed in
hard copy may be obtained by contacting an Emerson Process
accordance with Rosemount drawing 00849-1000.
Management representative.
For use with Rosemount power module P/N 753-9220-0001
only.
ATEX Directive (94/9/EC) Enclosure Type 4X / IP66
Emerson Process Management complies with the ATEX N5 FM Class 1, Division 2, and Dust
Directive.
Non-Incendive for Class I, Division 2, Groups A, B, C, and
D.
Electro Magnetic Compatibility (EMC) (2004/108/EC) Dust Ignition-proof for Class II/III, Division 1, Groups E, F,
and G.
EN 61326-1:2006
Ambient Temperature Limits -50 to 85 °C
EN 61326-2-3:2006
Non-incendive when installed in accordance with
Rosemount drawing 00849-1000.
Radio and Telecommunications Terminal Equipment For use with Rosemount power module P/N 753-9220-0001
Directive (R&TTE) (1999/5/EC) only.
Emerson Process Management complies with the R&TTE Enclosure Type 4X / IP66
Directive.
CSA - Canadian Standards Association
Telecommunication Compliance I6 CSA Intrinsic Safety
All wireless devices require certification to ensure that they adhere Intrinsically Safe for Class I, Division 1, Groups A, B, C, and
to regulations regarding the use of the RF spectrum. Nearly every D.
country requires this type of product certification. Emerson is Temp Code T3C
working with governmental agencies around the world to supply Non-incendive for Class I, Division 2, Groups A, B, C, and D.
fully compliant products and remove the risk of violating country Enclosure Type 4X / IP66
directives or laws governing wireless device usage. For use with Rosemount power module P/N 753-9220-0001
only.
Intrinsically Safe and non-incendive when installed in
FCC and IC accordance with Rosemount drawing 00849-1016.
This device complies with Part 15 of the FCC Rules. Operation is N6 CSA Class 1, Division 2
subject to the following conditions: This device may not cause Non-Incendive for Class I, Division 2, Groups A, B, C, and
harmful interference, this device must accept any interference D.
received, including interference that may cause undesired Enclosure Type 4X / IP66.
operation. For use with Rosemount power module P/N 753-9220-0001
This device must be installed to ensure a minimum antenna only.
separation distance of 20 cm from all persons. Non-incendive when installed per Rosemount drawing
00849-1016.
Ordinary Location Certification for FM
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).

25
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

European Certifications Special Conditions for safe use (X):

I1 ATEX Intrinsic Safety 1. The surface resistivity of the antenna is greater than 1GΩ.
Certificate No.: Baseefa09ATEX0022X II 1G To avoid electrostatic charge build-up, it must not be rubbed
Ex ia IIC T5 (Ta = -60 °C to 40 °C) or cleaned with solvents or a dry cloth.
Ex ia IIC T4 (Ta = -60 °C to 70 °C) 2. The power module may be replaced in a hazardous area.
IP66 The power module has surface resistivity greater than 1GΩ
For use with Rosemount power module P/N 753-9220-0001 and must be properly installed in the wireless device
only. enclosure. Care must be taken during transportation to and
1180 from the point of installation to prevent electrostatic charge
build-up.
Special Conditions for safe use (X):
WirelessHART

1. The surface resistivity of the antenna is greater than 1GΩ.


To avoid electrostatic charge build-up, it must not be rubbed
or cleaned with solvents or a dry cloth.
2. The power module may be replaced in a hazardous area.
The power module has surface resistivity greater than 1GΩ
and must be properly installed in the wireless device
enclosure. Care must be taken during transportation to and
from the point of installation to prevent electrostatic charge
build-up.

Table 23. Sensor Parameters


Sensor
Uo = 6.6 V
Io = 3.2 mA
Po = 5.3 mW
Co = 22 uF
Lo = 1 H

IECEx Certifications
I7 IECEx Intrinsic Safety
Certificate No.: IECEx BAS 09.0004X
Ex ia IIC T6 (Tamb = -60 °C to 50 °C)
Ex ia IIC T5 (Tamb = -60 °C to 75 °C)
IP66
For use with Rosemount power module P/N 753-9220-0001
only.
Dimensional Drawings

Table 24. Sensor Parameters


Sensor
Uo = 6.6 V
Io = 3.2 mA
Po = 5.3 mW
Co = 22 uF
Lo = 1 H

26
Product Data Sheet
00813-0100-4697, Rev KA
October 2010 Rosemount 848T Family
Dimensional Drawings
848T Wireless Dimensional Drawings

5.55
(141,1)

WirelessHART
2.20
(55,8)

7.0
(177,8)

3.00
(76,3)
6.38
(162)
10.22
(259,7)

6.81
(173)

3.46
(87,8)

3.978
(101)

Dimensions are in inches (millimeters)

27
Product Data Sheet
00813-0100-4697, Rev KA
Rosemount 848T Family October 2010

The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
HART is a registered trademark of the HART Communication Foundation.
FOUNDATION is a trademark of the Fieldbus Foundation.
DeltaV is a mark of one of the Emerson Process Management companies.
All other marks are the property of their respective owners.

Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale

© 2010 Rosemount, Inc.

Emerson Process Management Emerson Process Management Emerson FZE Emerson Process ManagementAsia
Rosemount Inc. Blegistrasse 23 P.O. Box 17033 Pacific Pte Ltd
8200 Market Boulevard P.O. Box 1046 Jebel Ali Free Zone 1 Pandan Crescent
Chanhassen, MN 55317 USA CH 6341 Baar Dubai UAE Signapore 128461
T (U.S.) 1-800-999-9307 Switzerland T +65 6777 8211
T +971 4 883 5235
T +41 (0) 41 768 6111 F +65 6777 0947
T (International) (952) 906-8888 F +41 (0) 41 768 6300 F +971 4 883 5312 Service Support Hotline: +65 6770 8711
F (952) 949-7001 Email: [email protected]
www.rosemount.com

00813-0100-4697 Rev KA 10/10

You might also like