At-Dc Series Air Handlers: Compact Units With DC "Whispercool" Blowers

The document describes the AT-DC series of chilled water air handlers. The air handlers feature whisper-quiet DC blowers, improved cooling and dehumidification performance, and designs that eliminate condensate drain problems. They are suitable for marine HVAC applications. Specifications are provided for nominal cooling/heating capacities, electrical requirements, water and air flows, and unit dimensions for various models in the AT-DC series.

Uploaded by

Damir Milisa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

At-Dc Series Air Handlers: Compact Units With DC "Whispercool" Blowers

The document describes the AT-DC series of chilled water air handlers. The air handlers feature whisper-quiet DC blowers, improved cooling and dehumidification performance, and designs that eliminate condensate drain problems. They are suitable for marine HVAC applications. Specifications are provided for nominal cooling/heating capacities, electrical requirements, water and air flows, and unit dimensions for various models in the AT-DC series.

Uploaded by

Damir Milisa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CHILLED WATER AIR CONDITIONING

W ec
hi hn
T
sp o
er log
C y
oo
AT-DC Series Air Handlers

l
Compact Units With DC "WhisperCool" Blowers

Key Benefits

■■ DC "WhisperCool" blowers are extremely


quiet yet powerful enough to overcome
high-static-pressure duct.
■■ Improved cooling and dehumidification.
■■ Drain pan has anti-slosh, anti-fungal foam
lining.
■■ Vibration-isolation mounts reduce noise
and vibration.
■■ Exposed components are insulated
against secondary condensation.
■■ Remote air bleeder on 6 ft. (1.8 m) of
flexible tubing with ball valve.
■■ Electrical box can be remotely mounted
The AT-DC series of chilled water air handlers represents the new standard in marine HVAC up to 6 ft. (1.8 m).
engineering that you'll barely notice. Thanks to "WhisperCool" technology, the AT-DC series ■■ Rotatable blowers.
harnesses engineering refinements to eliminate the annoying "motor hum" heard from ordinary
air handlers operating at very low fan speeds. Incoming alternating current is converted to drive ■■ Optional flow control automatically
a brushless DC internal blower motor, resulting in super-quiet and highly-efficient performance balances circulated water throughout the
across all fan speeds. system.
■■ Optional Electric Heat.
Additional design changes in the air handlers eliminate condensate drain problems, reduce
dripping condensation and standing water issues. An improved coil enhances cooling and
dehumidification performance. The redesigned unit also creates easily accessible water-pressure
test points for troubleshooting and maintenance.

All Marine Air air handlers use corrosion-resistant materials. They feature "positive-flow" drain pans
with anti-slosh foam lining and are fully insulated against secondary condensation. Electric heat is
optional.

ISO 9001:2008 L-2426B Rev. 20120824


Specifications for AT-DC Series Air Handlers Dimensions
Model (1) AT6DC AT9DC AT12DC AT18DC AT24DC AT36DC
Nominal Capacity - Cool (BTU/h) 6000 9000 12000 18000 24000 36000
Nominal Capacity - Heat (BTU/h) 3412 3412 5118 5118 10236 10236
Voltage @ 50/60Hz 1-Ph (V) 230 230 230 230 230 230
Full Load Amps (FLA) Cool (A) (2) 1.4 1.4 3.2 3.9 3.9 3.9
Max. Height
Full Load Amps (FLA) Blower (A) 1.4 1.4 3.2 3.9 3.9 3.9 Min. Height
Optional Electric Heat (kW) 1 1 1.5 1.5 3 3
Heater Amps (A) 4.3 4.3 6.5 6.5 13 13
Max. Circuit Breaker (A) 5 5 5 5 5 5
Min. Circuit Ampacity (A) 2 2 4 5 5 5
Water Flow (gpm/lpm) 1.5/5.7 2.25/8.6 3/11.4 4.5/17.1 6/22.8 9/34.1
Air Flow (cfm/m3h) 200/339.9 300/509.8 400/679.7 600/1019.5 700/1189.4 800/1359.3 Max. Depth Max. Width
External Static Pressure (inH2O/Pa) 2.9/722.1 2.8/697.2 2.6/647.4 2.1/522.9 1.4/348.6 0.5/124.5
Min. Height (in/mm) (3) 11.08/282 11.79/300 12.05/307 14.83/377 16.7/425 16.74/426
Max. Height (in/mm) (3) 13.63/347 13.73/349 13.94/355 16.94/431 16.7/425 19.74/502
Max. Width (in/mm) (3) 14.81/377 16.48/419 18.75/477 20.08/511 22.48/571 26.41/671
Max. Depth (in/mm) (3) 14.27/363 14.55/370 14.49/369 14.83/377 16.42/418 17.15/436
Drain Connection Size (in) 1/2 1/2 1/2 1/2 1/2 1/2
Drain Connection Type FPT FPT FPT FPT FPT FPT
Chilled Water Connection Size (in) 1/2 1/2 1/2 1/2 1/2 1/2
Chilled Water Connection Type FPT FPT FPT FPT FPT FPT
Min. Supply Duct Size (in/mm) 5/127 6/153 6/153 7/178 8/204 8/204
Min. Supply Air Grille Size (sq in/sq cm) 35/226 49/317 70/452 100/646 140/904 196/1265
Min. Return Air Grille Size (sq in/sq cm) 70/452 98/633 130/839 200/1291 240/1549 360/2323
Height-Electrical Box (in/mm) 8/204 8/204 8/204 8/204 8/204 8/204
Width-Electrical Box (in/mm) 6.13/156 6.13/156 6.13/156 6.13/156 6.13/156 6.13/156
Depth-Electrical Box (in/mm) 2/51 2/51 2/51 2/51 2/51 2/51
1 ‘Z’ indicates 230V. Add ‘-FC’ for optional flow control; add ‘-LX’ or ‘-RX’ for valve position (relative to the blower side of the coil) and angle of the blower (‘-R0’ is the default); add ‘#kW’ for amount of
optional electric heat in kilowatts.
2 Blower amps will be reduced at lower speed/cfm or higher static pressure. Amps listed are at free air.
3 All dimensions ± 0.30 in. (8 mm).

Dometic Marine Division


Dealer
2000 N. Andrews Ave. | Pompano Beach, FL 33069 USA | Tel. 954-973-2477 | Fax: 954-979-4414
www.Dometic.com/Marine | [email protected]
24/7 Tech Support for United States & Canada:
8:00 AM to 5:00 PM Eastern Time: 800-542-2477
After hours and weekends: 888-440-4494
International Sales & Services
Europe & the Middle East: Call +44(0)870-330-6101
For all other areas visit our website to find your nearest distributor.
Assembled in the USA
CHILLED WATER AIR CONDITIONING