Architectural Mechanical Electrical Structural: M6 Washroom Renovation

This document contains a list of architectural, mechanical, electrical, and structural drawings for a washroom renovation project. The architectural drawings include floor plans and reflected ceiling plans. The mechanical drawings include plumbing and HVAC demolition and new work. The electrical drawings include lighting, fire alarm, and power/systems work. The structural drawings include general notes, specifications, and details. Contact information is provided for the architects, mechanical engineer, electrical engineer, and structural engineer working on the project.

Uploaded by

Biyan Setya
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views

Architectural Mechanical Electrical Structural: M6 Washroom Renovation

This document contains a list of architectural, mechanical, electrical, and structural drawings for a washroom renovation project. The architectural drawings include floor plans and reflected ceiling plans. The mechanical drawings include plumbing and HVAC demolition and new work. The electrical drawings include lighting, fire alarm, and power/systems work. The structural drawings include general notes, specifications, and details. Contact information is provided for the architects, mechanical engineer, electrical engineer, and structural engineer working on the project.

Uploaded by

Biyan Setya
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

ARCHITECTURAL MECHANICAL ELECTRICAL STRUCTURAL

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
EDWARD J CUHACI & ASSOCIATES ARCHITECTS INC. GOODKEY WEEDMARK AND ASSOCIATES GOODKEY WEEDMARK AND ASSOCIATES ADJELEIAN ALLEN RUBELI C C drawing no. B C
PHONE: 613-727-5111 PHONE: 613-727-5111 PHONE: 613-232-5786 dessin no.

PHONE: 613-236-7135 FAX: 613-727-5115 FAX: 613-727-5115 FAX: 613-230-8916 project projet
FAX: 613-236-1944
M6
WASHROOM
ARCHITECTURAL DRAWINGS - M2-5121 & M59-5123 MECHANICAL DRAWINGS ELECTRICAL DRAWINGS STRUCTURAL DRAWINGS RENOVATION
A01- LEGEND, NOTES, WALL TYPES AND TYPICAL DETAILS
A02 - ROOM FINISH AND DOOR SCHEDULE M1 - MECHANICAL DRAWING LIST, LEGENDS E1 - ELECTRICAL LEGENDS, DRAWING LIST S01 - GENERAL NOTES AND SPECIFICATIONS
A03 - GROUND FLOOR REFLECTED CEILING PLANS AND SCHEDULE AND KEY PLANS S02 - STRUCTURAL DETAILS drawing dessin

A04 - MEZZANINE FLOOR PLANS M2 - M6 - GROUND FLOOR AND MEZZ E2 - SECOND FLOOR LIGHTING AND FIRE
A05 - MEZZANINE REFLECTED CEILING PLANS WASHROOM PLUMBING DEMOLITION ALARM WORK LIST OF DRAWINGS
AND NEW WORK E3 - SECOND FLOOR POWER AND SYSTEMS
M3 - M6 - GROUND FLOOR AND MEZZ WORK
WASHROOM HVAC DEMOLITION AND
NEW WORK
Designed By
J.V.D. / J.J.
Date 2016 03 04 (yyyy/mm/dd)
Drawn By
A.W.
Date 2016 03 07 (yyyy/mm/dd)
Reviewed By
J.J.
Date 2016 03 09 (yyyy/mm/dd)
Approved By
BRANDON LALONDE
Date 2016 06 22 (yyyy/mm/dd)
Tender Soumission
ISABELLE D'AMOUR TANGUAY

Project Manager Administrateur de projets


W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-CS1
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
VIEWNUMBER
SHEETNUMBER

VIEWNUMBER
SHEETNUMBER

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

M6
WASHROOM
TYPICAL MOUNTING HEIGHTS RENOVATION

drawing dessin

LEGEND, NOTES,
WALL TYPES,
AND TYPICAL DETAILS

Designed By
J.V.D. / J.J.
Date 2016 03 04 (yyyy/mm/dd)
Drawn By
A.W.
Date 2016 03 07 (yyyy/mm/dd)
Reviewed By
J.J.
Date 2016 03 09 (yyyy/mm/dd)
Approved By
BRANDON LALONDE
Date 2016 06 22 (yyyy/mm/dd)
Tender Soumission
ISABELLE D'AMOUR TANGUAY

Project Manager Administrateur de projets


W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-A01
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

M6
WASHROOM
RENOVATION

drawing dessin

ROOM FINISH &


DOOR SCHEDULE
SECTIONS

Designed By
J.V.D. / J.J.
Date 2016 03 04 (yyyy/mm/dd)
Drawn By
A.W.
Date 2016 03 07 (yyyy/mm/dd)
Reviewed By
J.J.
Date 2016 06 22 (yyyy/mm/dd)
Approved By
BRANDON LALONDE
Date 2016 06 22 (yyyy/mm/dd)
Tender Soumission
ISABELLE D'AMOUR TANGUAY
PROJECT_MAN
Project Manager Administrateur de projets
W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-A02
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

M6
WASHROOM
RENOVATION

drawing dessin

GROUND FLOOR
REFELECTED
CEILING PLANS

Designed By
DESIGNED_BY
Date DATE_DESIGNED (yyyy/mm/dd)
Drawn By
J.V.D.
Date 2016 04 08 (yyyy/mm/dd)
Reviewed By
REVIEWED_BY
Date DATE_REVIEWED (yyyy/mm/dd)
Approved By
APPROVED_BY
Date DATE_APPROVED (yyyy/mm/dd)
Tender Soumission
TENDER
PROJECT_MAN
Project Manager Administrateur de projets
W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-A03
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A02

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
A02 dessin no.

project projet

M6
WASHROOM
RENOVATION

drawing dessin

MEZZANINE
FLOOR PLANS

Designed By
DESIGNED_BY
Date DATE_DESIGNED (yyyy/mm/dd)
Drawn By
J.V.D.
Date 2016 04 08 (yyyy/mm/dd)
Reviewed By
REVIEWED_BY
Date DATE_REVIEWED (yyyy/mm/dd)
Approved By
APPROVED_BY
Date DATE_APPROVED (yyyy/mm/dd)
Tender Soumission
TENDER
PROJECT_MAN
Project Manager Administrateur de projets
W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-A04
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A02

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
A02 dessin no.

project projet

M6
WASHROOM
RENOVATION

drawing dessin

MEZZANINE
REFLECTED CEILING
PLAN

Designed By
DESIGNED_BY
Date DATE_DESIGNED (yyyy/mm/dd)
Drawn By
J.V.D
Date 2017 04 08 (yyyy/mm/dd)
Reviewed By
REVIEWED_BY
Date DATE_REVIEWED (yyyy/mm/dd)
Approved By
APPROVED_BY
Date DATE_APPROVED (yyyy/mm/dd)
Tender Soumission
TENDER
PROJECT_MAN
Project Manager Administrateur de projets
W.O. no. D.T. no.

A1-010981-01
Drawing no. No. du dessin

5122-A05
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
NRC MONTREAL ROAD CAMPUS BUILDINGS M6 WASHROOMS RENOVATION
1200 MONTREAL ROAD, OTTAWA

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

MECHANICAL
DRAWING LIST,
LEGENDS &
SCHEDULES
Designed By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

M1
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

M6 - GROUND FLOOR &


MEZZ WASHROOM
PLUMBING DEMOLITION
& NEW WORK
Designed By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

M2
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

M6 - GROUND FLOOR &


MEZZ WASHROOM
HVAC DEMOLITION &
NEW WORK
Designed By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
S.VALLIER
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R.LEONARD
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

M3
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
NRC MONTREAL ROAD CAMPUS BUILDINGS M6 WASHROOM RENOVATION
1200 MONTREAL ROAD, OTTAWA
ELECTRICAL

A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

ELECTRICAL
LEGENDS,
DRAWING LIST AND
KEY PLANS
Designed By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

E1
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

SECOND FLOOR
LIGHTING AND FIRE
ALARM WORK

Designed By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

E2
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

SECOND FLOOR
POWER AND SYSTEMS
WORK

Designed By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

E3
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
A detail no.
no. du detail
A B location drawing no.
A
sur dessin no.
C C drawing no. B C
dessin no.

project projet

NRC BUILDINGS M6
M6 WASHROOM
RENOVATION

drawing dessin

ELECTRICAL SINGLE
LINE DIAGRAM

Designed By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Drawn By
A. GIRARD
Date 2016-04-13 (yyyy/mm/dd)
Reviewed By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Approved By
R. BOIVIN
Date 2016-04-13 (yyyy/mm/dd)
Tender Soumission

Project Manager Administrateur de projets


W.O. no. D.T. no.

5122
Drawing no. No. du dessin

E4
PWGSC A1 (841x594)
0 10 20mm 40 60 80 100 120 140 160 180 200mm
GENERAL INSPECTIONS AND TESTING
THE GENERAL NOTES AND TYPICAL DETAILS ARE APPLICABLE TO ALL STRUCTURAL CONDITIONS NOT SPECIFICALLY DETAILED OR THE FOLLOWING ITEMS SHALL BE INSPECTED OR TESTED BY INDEPENDENT INSPECTION/ TESTING AGENCIES DESIGNATED BY THE
REFERENCED ON STRUCTURAL DRAWINGS. CLIENT. MATERIALS AND WORKMANSHIP NOT CONFORMING TO THE SPECIFICATIONS SHALL BE REJECTED BY THE CONTRACTOR.
REPORTS AND TEST RESULTS SHALL BE PROMPTLY SUBMITTED TO THE ENGINEER FOR REVIEW. TESTING SHALL INCLUDE BUT NOT BE
THESE NOTES, DETAILS AND DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT SPECIFICATIONS. LIMITED TO:

THESE DRAWINGS ARE FOR THE USE OF THE CONSULTANT'S CLIENT ONLY. ALL INFORMATION SHOWN APPLIES TO THIS PROJECT ONLY CONCRETE:
AND REFLECTS THE BEST JUDGEMENT OF THE CONSULTANT IN LIGHT OF THE AVAILABLE INFORMATION AT THE TIME OF PREPARATION. CONCRETE AND GROUT TESTING IN ACCORDANCE WITH CSA A23.2 LATEST EDITION AND THE SPECIFICATIONS, INCLUDING THE
DECISIONS OR ACTIONS MADE BY THIRD PARTIES BASED ON THE DRAWINGS ARE THE SOLE RESPONSIBILITY OF SUCH PARTIES. REQUIREMENTS OF SLUMP, AIR AND AGE BEFORE BEING USED. CONTRACTOR TO KEEP RECORDS OF POUR DATES, TESTING
PERFORMED, CLASS OF CONCRETE USED WITH LOCATION AND TEST RESULTS FOR ALL ITEMS POURED.
THESE DRAWINGS ARE THE PROPERTY OF ADJELEIAN ALLEN RUBELI LTD. AND MAY NOT BE REPRODUCED IN ANY FORM WITHOUT
WRITTEN PERMISSION. TESTING TO DETERMINE THE IN-SITU STRENGTH OF CONCRETE FOR EARLY FORM REMOVAL PURPOSES WITH THE TYPE OF TEST BEING
DETERMINED ON THE ADVICE OF THE TESTING AGENCY. REPAIRS NECESSARY TO THE STRUCTURE AS A RESULT OF THESE TESTS SHALL
BE MADE BY THE CONTRACTOR AT NO EXPENSE TO THE OWNER.
CODES AND STANDARDS
TESTING AS REQUIRED AND SPECIFIED BY THE ENGINEER TO DETERMINE THE IN-SITU STRENGTH OF CONCRETE WHICH FAILS TO MEET
THE SPECIFIED REQUIREMENTS OR WHICH, DUE TO APPEARANCE, DAMAGE OR DEFECTS MAY BE DEEMED REJECTABLE. CORES SHALL
THROUGHOUT THESE DRAWINGS MEANS THAT CODE.
BE ACQUIRED AND TESTED BY THE DESIGNATED TESTING AGENCY BUT ANY REPAIRS NECESSARY TO THE STRUCTURE AS A RESULT OF
THESE TESTS SHALL BE PERFORMED AT NO COST TO THE OWNER.
SHOP DRAWINGS
STRUCTURAL STEEL & CONNECTIONS:
STRUCTURAL STEEL CONNECTIONS: WELDING INSPECTIONS TO BE VISUAL, EXCEPT WHERE NON-DESTRUCTIVE TESTING IS DEEMED NECESSARY BY THE TESTING AGENCY
STRUCTURAL STEEL CONNECTIONS SHALL BE DESIGNED TO RESIST THE INDICATED FACTORED MEMBER REACTIONS BY A PROFESSIONAL OR ENGINEER. NON-DESTRUCTIVE TESTING TO VERIFY THE QUALITY OF WELDING, WHERE DEEMED QUESTIONABLE BY VISIBLE DEFECTS
ENGINEER WHO WILL ALSO SEAL AND SIGN THE SHOP DRAWINGS. OR WHERE REQUIRED BY THE ENGINEER.

DIMENSIONS REINFORCING STEEL


CHECK DIMENSIONS ON THESE DRAWINGS AGAINST DIMENSIONS ON ARCHITECTURAL DRAWINGS BEFORE USING THEM FOR FABRICATION DETAIL AND PLACE REINFORCING STEEL IN ACCORDANCE WITH THE R.S.I.C. "REINFORCING STEEL MANUAL OF STANDARD PRACTICE"
OR CONSTRUCTION. REPORT DISCREPANCIES IMMEDIATELY UPON DISCOVERY. AND CSA-A23.1 UNLESS OTHERWISE NOTED.

DRAWINGS HAVE BEEN MADE REASONABLY TO SCALE BUT CONTRACTOR MUST NOT SCALE THE DRAWINGS. REINFORCING BAR SHALL BE DEFORMED GRADE 400W AS PER CSA G30.18.

CONTRACTOR TO CONFIRM EXISTING BUILDING LOCATION AND TIE-IN POINTS BEFORE CONSTRUCTION. PROVIDE WELDED WIRE FABRIC AS SPECIFIED IN CSA G30.5M - FLAT SHEETS ONLY.

RECORD DRAWINGS OPENINGS


CONTRACTOR SHALL MAINTAIN TWO SETS OF RECORD DRAWINGS, SHOWING AS-BUILT CONDITIONS OF ALL ASPECTS OF THE STRUCTURE, REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND TO SHOP DRAWINGS OF ALL TRADES FOR EXACT LOCATION
AVAILABLE FOR REVIEW DURING CONSTRUCTION, AND FOR SUBMISSION TO THE CONSULTANT AND THE OWNER UPON PROJECT COMPLETION. AND EXTENT OF OPENINGS REQUIRED BUT NOT SHOWN ON THE STRUCTURAL DRAWINGS.

SCAN AREA FOR EXISTING REINFORCING STEEL. OBTAIN THE APPROVAL OF THE STRUCTURAL ENGINEER FOR OPENINGS REQUIRED BUT
STRUCTURAL STEEL: NOT SHOWN ON THE STRUCTURAL DRAWINGS. DO NOT CORE DRILL, SAWCUT OR OTHERWISE PRODUCE OPENINGS OF ANY SIZE, IN ANY
STRUCTURAL MEMBER WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
STRUCTURAL STEEL DESIGN AND CONSTRUCTION SHALL COMPLY WITH CSA S16, UNLESS OTHERWISE NOTED.
CONCRETE
ITEM APPLICABLE MATERIAL SPECIFICATION
C CSA G40.20/G40.21 - 300W ALL CONCRETE WORK TO BE IN ACCORDANCE WITH CSA-A23.1 AND CSA-A23.3

APPEARANCE OF EXPOSED CONCRETE SHALL BE TO THE APPROVAL OF THE ARCHITECT.


ALL STRUCTURAL STEEL TO BE PRIME PAINTED EXCEPT STEEL RECEIVING GALVANIZING, OR STEEL TO BE CAST-IN CONCRETE.
NEW CONCRETE TO BE KING FA-S10 (OR APPROVED EQUIVALENT).
DO NOT CUT OR CORE ANY OPENINGS IN ANY STRUCTURAL STEEL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL FROM THE
STRUCTURAL ENGINEER.

Project: Drawn: Project No.


J.M. 5564-11
0 2017-09-06 ISSUED FOR TENDER
NRC M6 BUILDING Scale: Drawing
AS NOTED
SLAB INFILL Date: S01
No Date Revision SEPT. 2017
EXISTING POST
EXISTING C250x30 EXISTING GRATING

NEW CEILING EXISTING C250x30 BEYOND


(REFER TO ARCH.)
NEW CONCRETE INFILL

MESH 152x152 MW25.8 x MW25.8 DRILL AND EPOXY GROUT 15M


BARS @ MID DEPTH, ONE EACH
CHIP EDGES TO SIDE (4 TOTAL) USING HILTI
PROVIDE TAPER HIT-HY200 (EMBED = 145mm)

NEW L152x152x9.5 WELDED EXISTING HSS COLUMN


TO EXISTING C250x30 AND
HSS COLUMN FOR Vf = 5kN/m EXISTING SLAB

NEW CEILING CONNECTION @ STAIRS TYPICAL SLAB INFILL DETAIL


1 : 10 1 : 10 REFER TO ARCH. FOR LOCATIONS

Project: Drawn: Project No.


J.M. 5564-11
0 2017-09-06 ISSUED FOR TENDER
NRC M6 BUILDING Scale: Drawing
AS NOTED
SLAB INFILL Date: S02
No Date Revision SEPT. 2017