TP70 DIP SETTING Malaysia1

This document provides instructions for setting the DIP switches on a MYR7 bill acceptor. It lists the DIP switch functions and settings for accepting Malaysian currency denominations of 1, 2, 5, 10, 20, 50, and 100 in pulse mode. It also provides settings for the pulse protocol and harness functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

TP70 DIP SETTING Malaysia1

This document provides instructions for setting the DIP switches on a MYR7 bill acceptor. It lists the DIP switch functions and settings for accepting Malaysian currency denominations of 1, 2, 5, 10, 20, 50, and 100 in pulse mode. It also provides settings for the pulse protocol and harness functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MYR7

TP70/P5 DIP SWITCHES SETTING : 1(002/Pulse)


Supported bill MYR 1、2、5、10、20、50、100 ( Malaysia )
DIP1 Function SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10
★ 1 Pulse / MYR 1 OFF OFF OFF
2 Pulse / MYR 1 OFF OFF ON
3 Pulse / MYR 1 OFF ON OFF
4 Pulse / MYR 1 OFF ON ON
5 Pulse / MYR 1 ON OFF OFF
10 Pulse / MYR 1 ON OFF ON
20 Pulse / MYR 1 ON ON OFF
100 Pulse / MYR 1 ON ON ON
Lo= 50ms
Fast Output Pulse ON
Hi=100ms
★ Lo= 50ms
Slow Output Pulse OFF
Hi=300ms
Inhibit level Active Low ON
★ Inhibit level Active High OFF
★ Accept MYR 1 & 2 ON
Reject MYR 1 & 2 OFF
★ Accept MYR 5 ON
Reject MYR 5 OFF
★ Accept MYR 10 ON
Reject MYR 10 OFF
★ Accept MYR 20 ON
Reject MYR 20 OFF
★ Accept MYR 50 &100 ON
Reject MYR 50 &100 OFF
★ Menufacture setting
Note: (1) Please reset the bill acceptor after any changes on Dip switch.
(2) Dip Switch 1 to 5 are only for Pulse mode.

DIP SWITCHS SETTING : 2 Currency Assign Data


DIP2 FUNCTION SW1 SW2 SW3 SW4 Interface
RS232 Pulse
★ Pulse Normal High ON Bill value
Pulse Normal Low OFF BV1 1 1
★ Pulse Protocol ON BV2 2 2
RS232 Protocol OFF BV3 5 5
Harness Disable ON BV4 10 10
★ Harness Enable OFF BV5 50 50
Manufacture Default ON BV6 100 100
★ System Default OFF BV7 20 20
★ Menufacture setting
Note: (1) Please reset the bill acceptor after any changes on Dip switch
(2) Dip Switches 1 & 3 are only used for pulse protocol.