Structural Engineering

This document provides an index and listing of structural drawings for proposed new dwellings. The index includes 21 structural drawing sheets with titles related to footings, slabs, drainage, bracing, and other structural elements. Notes indicate that the drawings are to be read with other project documents and it is the client's responsibility to check buildability. Dimensions are not to be obtained by scaling and discrepancies should be referred to the engineer.

Uploaded by

Michelle Kiera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
274 views

Structural Engineering

This document provides an index and listing of structural drawings for proposed new dwellings. The index includes 21 structural drawing sheets with titles related to footings, slabs, drainage, bracing, and other structural elements. Notes indicate that the drawings are to be read with other project documents and it is the client's responsibility to check buildability. Dimensions are not to be obtained by scaling and discrepancies should be referred to the engineer.

Uploaded by

Michelle Kiera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

INDEX TO SHEETS

SHEET TITLE
S-000 COVER SHEET & DRAWING LIST
S-001 GENERAL NOTES
S-002 STRUCTURAL NOTES
S-101 FOOTING & SLAB PLAN
S-201 FOOTING & SLAB DETAILS - SHEET 1
S-202 FOOTING & SLAB DETAILS - SHEET 2
S-203 FOOTING & SLAB DETAILS - SHEET 3
S-204 DEEP EDGE & DEEP STEP BEAM DETAILS
S-205 STRIP FOOTING DETAILS
S-206 PIERING DETAILS

WA QLD NSW VIC S-207


S-208
S-209
SURFACE DRAINAGE DETAILS
PLUMBING CONNECTION DETAILS
MASONRY ARTICULATION DETAILS
www.structerre.com.au S-301 WIND BRACING PLAN
S-401 WIND BRACING DETAILS
S-402 WIND BRACING NOTES

PROPOSED NEW DWELLINGS FOR

TORO HOMES

IMPORTANT NOTE:
IT IS THE RESPONSIBILITY OF THE CLIENT IN CONSULTATION WITH THEIR BUILDER TO CHECK AND VERIFY
THE BUILDABILITY OF THE DESIGN AS PRESENTED AND REFER ANY CONCERNS BACK TO THE ENGINEER
PRIOR TO CONSTRUCTION. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS.
IT IS ASSUMED THAT THE USER OF THESE DETAILS HAS A LEVEL OF FAMILIARITY AND COMPETENCY TO
UNDERSTAND AND EXECUTE THE WORKS.
AT ALL TIMES COMMON SENSE IS TO BE USED
IF EVER IN DOUBT, ASK!

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


TORO HOMES COVER SHEET AND DRAWING LIST LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-000
1-2-063810758693-0000000-14734-000052243031302
GENERAL NOTES: CUT-AND-FILL SITES, SHALL BE GRADED TO FALL 50mm MINIMUM AWAY FROM FOUNDATIONS AND FOOTINGS:
THE FOOTING OVER A DISTANCE OF 1.0m. SURFACE OR SUBSURFACE DRAINS SUMMARY OF AS2870-2011 - TABLE 2.2 - Classification of normal site footing
G.1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL SHALL BE USED TO CHANNEL WATER AWAY AND CONNECT TO STORMWATER performance for brick veneer & full masonry construction F.1. FOOTINGS SHALL BE PLACED CENTRALLY UNDER WALLS AND COLUMNS
AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH SYSTEM. ANY PAVING SHALL ALSO BE SUITABLY SLOPED. UNLESS OTHERWISE NOTED.
SITE EXPECTED DAMAGE DAMAGE CATEGORIES (C1 & C2 OF
OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF F.2. ALL WORKMANSHIP & MATERIALS SHALL BE IN ACCORDANCE WITH AS 2870 &
D.3. PLUMBING TRENCHES SHALL BE SLOPED AWAY FROM THE HOUSE AND SHALL CLASS CATEGORIES APPENDIX C)
THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE NATIONAL CONSTRUCTION CODE (N.C.C.)
ARCHITECT/ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK. BE BACKFILLED WITH CLAY IN THE TOP 300mm WITHIN 1.5m OF THE HOUSE. THE A & S CATEGORY 0 & 1 WALL CRACKS < 1mm
CLAY USED FOR BACKFILLING SHALL BE COMPACTED. WHERE PIPES PASS SLAB CRACKS < 1mm F.3. THE FOOTING DETAILS SHOWN ARE FOR THE SITE CLASSIFICATION
G.2. DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE STRUCTURAL UNDER THE FOOTING SYSTEM, THE TRENCH SHALL BE BACKFILLED WITH CLAY STIPULATED. WHILST EVERY CARE HAS BEEN TAKEN TO VERIFY THAT THE
DRAWINGS. LEVEL CHANGES < 8mm OVER 3m
OR CONCRETE TO RESTRICT THE INGRESS OF WATER BENEATH THE FOOTING OFTEN CATEGORY 1 & OFTEN WALL CRACKS <1 mm. & INFORMATION SHOWN IS CORRECT, STRUCTERRE CONSULTING ENGINEERS
G.3. SETTING OUT DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY SYSTEM. RARELY 2 RARELY 1 < 5mm TAKE NO RESPONSIBILITY FOR VARIATIONS WHICH MAY OCCUR DUE TO
THE BUILDER. D.4. EXCAVATIONS NEAR THE EDGE OF THE FOOTING SYSTEM SHALL BE BACKFILLED M SLAB CRACKS 1 < 2mm VARIATIONS IN SITE CONDITIONS.
G.4. DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE IN SUCH A WAY AS TO PREVENT ACCESS OF WATER TO THE FOUNDATION. FOR LEVEL CHANGES 10 < 15mm OVER 3m F.4. FILL USED IN THE CONSTRUCTION OF A SLAB EXCEPT WHERE THE SLAB IS
CONDITION AND NO PART SHALL BE OVERSTRESSED. EXAMPLE, EXCAVATIONS SHOULD BE BACKFILLED ABOVE OR ADJACENT THE OFTEN WALL CRACKS < 5 mm & SUSPENDED SHALL CONSIST OF A CONTROLLED FILL OR ROLLED FILL IN
FOOTING WITH MOIST CLAY, COMPACTED BY HAND-RODDING/TAMPING. OFTEN CATEGORY 1 & 2 ACCORDANCE WITH AS 2870:
G.5. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RARELY 5 < 15mm
REQUIREMENTS OF THE CURRENT EDITIONS OF THE AS CODES AND THE POROUS MATERIAL SUCH AS SAND, GRAVEL OR BUILDING RUBBLE SHOULD H1/H2 RARELY CATEGORY 3 SLAB CRACKS 2 < 4mm F.4.1. ROLLED FILL CONSISTS OF MATERIAL COMPACTED IN LAYERS BY
BY-LAWS AND ORDINANCES OF THE RELEVANT BUILDING STATE AUTHORITY. NOT BE USED. REPEATED ROLLING WITH AN EXCAVATOR. ROLLED FILL SHALL NOT
LEVEL CHANGES OF 15 < 25mm OVER 3m
G.6. THIS REPORT IS BASED ON INFORMATION SUPPLIED BY THE CLIENT. IF ANY D.5. WATER RUN-OFF SHALL BE COLLECTED AND CHANNELED AWAY FROM THE E OFTEN CATEGORY 3 OR MORE OFTEN WALLS CRACKS 15 < 25mm EXCEED 600mm COMPACTED IN LAYERS NOT MORE THAN 300mm FOR
ASPECT OF THE SITE PREPARATION OR PROPOSED CONSTRUCTION CHANGES HOUSE DURING CONSTRUCTION. SAND MATERIAL OR 400mm COMPACTED IN LAYERS NOT MORE THAN
SLAB CRACKS 2 < 4mm OR MORE 150mm FOR OTHER MATERIAL.
FROM THAT ORIGINALLY ADVISED, THE ENGINEER MUST BE NOTIFIED SO THAT D.6. PENETRATIONS OF THE EDGE BEAMS AND FOOTING BEAMS ARE TO BE LEVEL CHANGES > 25mm OVER 3m
ANY NECESSARY AMENDMENTS CAN BE MADE. AVOIDED, BUT WHERE NECESSARY SHALL BE SLEEVED TO ALLOW FOR F.4.2. CONTROLLED FILL CONSISTS OF WELL GRADED SAND FILL UP TO 800mm
G.7. DEVELOPMENT APPLICATION DECISION NOTICE - FOR WORK REQUIRING MOVEMENT. DEEP, WELL COMPACTED IN NOT MORE THAN 300mm LAYERS BY
ARTICULATED MASONRY NOTES: VIBRATING PLATE OR VIBRATING ROLLER. NO SAND FILL UP TO 400mm
BUILDING APPROVAL, THE DEVELOPMENT APPLICATION DECISION NOTICE, D.7. CONNECTION OF STORMWATER DRAINS AND WASTE DRAINS SHALL INCLUDE
ISSUED BY THE COUNCIL OR BUILDING CERTIFIER MUST BE FORWARDED TO US FLEXIBLE CONNECTIONS. A.1. THIS DESIGN ASSUMES THAT MASONRY ARTICULATION JOINTS WILL BE DEEP, WELL COMPACTED IN NOT MORE THAN 150mm LAYERS BY A
PRIOR TO ARRANGING ANY INSPECTIONS WITH THIS OFFICE. INSTALLED UNLESS NOTED OTHERWISE ON FOOTING & SLAB PLAN. ANY MECHANICAL ROLLER, CLAY FILL SHOULD BE MOIST DURING
D.8. ADDITIONAL PLUMBING REQUIREMENTS ARE NEEDED FOR MODERATELY, MASONRY ARTICULATION JOINTS SHALL BE POSITIONED IN ACCORDANCE COMPACTION. THE DEPTHS OF FILL GIVEN ABOVE ARE DEPTHS
SITE CLASSIFICATION NOTES: HEAVILY & EXTREMELY REACTIVE SITES IN ACCORDANCE WITH CLAUSE 6.6 (F) WITH TECHNICAL NOTE 61 PRODUCED BY CEMENT CONCRETE & AGGREGATES MEASURED AFTER COMPACTION. FOR COMPACTED DEPTHS GREATER
FROM AS 2870. AUSTRALIA AND AS 3700 SECTION 12.16.4. REFER TO TABLE BELOW FOR THAN THAT GIVEN ABOVE THE FILL SHALL BE SUBJECT TO CONTROL AND
S.C.1. THIS REPORT HAS BEEN BASED UPON INFORMATION PROVIDED TO OUR OFFICE
AND/OR GATHERED BY OUR STAFF. D.9. PLUMBING & DRAINAGE UNDER THE SLAB SHOULD BE AVOIDED WHERE MAXIMUM SPACING AND MASONRY ARTICULATION PLAN (IF PROVIDED) FOR TESTING. IF TEST FAILS THEN PIERS ARE REQUIRED. CONTACT THIS
PRACTICAL (REFER AS/NZS 3500 CLAUSE 4.10) SPECIFIC LOCATIONS AND DETAILS FOR RENOVATIONS OR EXTENSIONS TO OFFICE PRIOR TO FURTHER CONSTRUCTION.
S.C.2. THIS REPORT HAS BEEN PREPARED IN ACCORDANCE WITH AS 2870 AND EXISTING STRUCTURES.
RELEVANT STATE LEGISLATION. D.10. ALL PIPEWORK INCLUDING STORMWATER FITTINGS & ADAPTERS SHOULD BE F.5. TOP SOIL CONTAINING GRASS ROOTS OR OTHER ORGANIC MATERIAL SHALL
PROTECTED FROM MECHANICAL DAMAGE. A.2. MASONRY ARTICULATION JOINTS SHALL BE POSITIONED WHERE EVER NEW BE REMOVED FROM THE AREA ON WHICH THE SLAB IS TO REST.
S.C.3. SHOULD SOIL CONDITIONS ENCOUNTERED ON SITE DIFFER SIGNIFICANTLY BRICKWORK MEETS OLD BRICKWORK.
FROM THOSE INDICATED IN THE SOIL TEST NOTED ABOVE, THE ENGINEER MUST D.11. PROVISIONS SHOULD BE MADE FOR THE CONNECTION OF OVERFLOW OR WATER F.6. IF ANY FOOTING IS LOCATED SUCH THAT A LINE DRAWN AT 45 DEGREES (FOR
BE NOTIFIED BEFORE PROCEEDING AS THE SITE CLASSIFICATION MAY NEED DISCHARGE FROM FIXTURES SUCH AS HOT WATER SYSTEMS & AIR A.3. WHERE MASONRY ARTICULATION IS SHOWN BESIDE OPENINGS WITH CLAY AND 30 DEGREES FOR SAND) FROM ITS BASE INTERSECTS A PRIVATE
REVISING AND MODIFICATIONS TO THE DESIGN MAY BE REQUIRED. CONDITIONERS TO A DRAIN AS REQUIRED BY THE RELEVANT LOCAL BRICKWORK ABOVE THE OPENING, CARE SHOULD BE TAKEN TO PROVIDE A SERVICE TRENCH, THEN PIERS ARE REQUIRED. SEE FOOTING & SLAB DETAILS
AUTHORITY. SLIP JOINT AROUND THE END OF THE LINTEL. FOR EXAMPLE.
S.C.4. THE SITE INVESTIGATION MAY BE RENDERED IRRELEVANT IF THE LOCATION OF
PROPOSED STRUCTURES VARY FROM THAT SPECIFIED AT THE TIME OF THIS PROPERTY MAINTENANCE NOTES: A.4. WHERE MASONRY ARTICULATION IS SHOWN BESIDE OPENINGS, THE JOINT F.7. FOOTING & SLAB PIERS ARE REQUIRED WHERE UNCONTROLLED FILL UNDER
REPORT. THIS REPORT RELATES TO THE CONDITIONS EXISTING ON THE LAND AT P.1. THIS DESIGN IS BASED UPON THE NORMAL FOOTING PERFORMANCE IS TO CONTINUE BETWEEN THE WINDOW/DOOR FRAME AND THE BRICKWORK THE EDGE BEAM/SLAB IS PRESENT.
THE TIME OF THE SITE INVESTIGATION. THIS REPORT IS BASED UPON THE TO THE FULL HEIGHT OF THE WALL. AT THESE LOCATIONS, THE FRAMES ARE F.8. WHERE PIERS ARE USED TO SUPPORT A SLAB ON UNCONTROLLED FILL,
CRITERIA PROVIDED IN TABLE 2.2 OF AS8270-2011 WITH DAMAGE TO BE FIXED WITH FASTENERS THAT WILL ALLOW MOVEMENT OF THE JOINT.
PROPOSED CUT / FILL INFORMATION PROVIDED BY THE CLIENT. ANY CATEGORIES DETAILED IN APPENDIX C. IF THESE PERFORMANCE CRITERIA IS PLUMBING AND DRAINAGE PIPES FOUNDED WITHIN SUCH FILL SHALL BE
UNADVISED EXTENSIVE CUTTING OR FILLING MAY RENDER THIS REPORT UNSUITABLE FOR THIS DWELLING PLEASE CONSULT THIS OFFICE FOR HUNG FROM THE SLAB MESH WITH NON-CORROSIVE STRAPS.
IRRELEVANT. ADDITIONAL ENGINEERING ADVISE AND DESIGN SERVICES. MAXIMUM SPACING OR ARTICULATION JOINTS TO AS 4773 F.9. FOR SATISFACTORY RESULTS, CONCRETE MUST BE CURED FOR AT LEAST 7
S.C.5. WHILE A REASONABLE EFFORT IS MADE TO ASSESS THE SITE'S SUITABILITY FOR P.2. THE OWNER'S ATTENTION IS DRAWN TO APPENDIX B 'PERFORMANCE (UNREINFORCED MASONRY) U.N.O DAYS. CURING MAY BE ACHIEVED BY KEEPING THE CONCRETE MOIST, BY
THE PROPOSED CONSTRUCTION, THIS REPORT DOES NOT TAKE INTO ACCOUNT CRITERIA AND FOUNDATION MAINTENANCE' AND APPENDIX C APPLYING A CURING COMPOUND, OR BY COVERING THE CONCRETE WITH A
SLOPE STABILITY. IF REQUIRED BY THE COUNCIL, A SUITABLY QUALIFIED JOINT SPACING (m) FOR WALL MOISTURE BARRIER. WHERE A CURING COMPOUND IS USED, IT MUST
'CLASSIFICATION OF DAMAGE DUE TO FOUNDATION MOVEMENTS' OF AS SITE HEIGHT
PERSON SHOULD BE ENGAGED TO UNDERTAKE A SLOPE STABILITY CONSTRUCTION & SURFACE FINISH COMPLY WITH AS3799 & BE APPLIED TO THE MANUFACTURERS
2870-2011. CLASS
ASSESSMENT. < 4m HIGH 4m TO 8.5m SPECIFICATIONS. MANY BUILDERS FIND THAT THE MOST SATISFACTORY WAY
P.3. WE ALSO DIRECT THE OWNER TO THE CSIRO PUBLICATION BTF 18 TO CURE A SLAB IS TO COVER IT WITH SHEETS OF POLYETHYLENE AS SOON
MISCELLANEOUS NOTES: A&S NOT REQUIRED - -
'FOUNDATION MAINTENANCE AND FOOTING PERFORMANCE: A HOMEOWNER'S AS POSSIBLE AFTER FINISHING. IF A SLAB IS MOIST WHEN COVERED AND
M.1. WHERE TERMITE PROTECTION IS REQUIRED, INSTALL IN ACCORDANCE WITH GUIDE'. COPIES OF THIS PUBLICATION ARE AVAILABLE FROM CSIRO EXTERNAL FACE FINISH 6.0 4.2
THE POLYETHYLENE IS HELD SECURELY ONTO THE CONCRETE, THIS SYSTEM
AS3660. BUILDER SHALL CONFIRM WITH OWNER THE PREFERRED METHOD OF PUBLISHING ON PH: 1300-788-000 OR AT EXTERNAL RENDERED/PAINTED 5.5 3.9 PROVIDES SATISFACTORY CURING OF THE CONCRETE.
M, M-D
TERMITE MANAGEMENT. OWNER IS RESPONSIBLE FOR ONGOING INSPECTION OF http://www.publish.csiro.au/nid/18/pid/3612.htm. THIS REPORT MAY BE INTERNAL FACE FINISH 6.0 4.2
STRUCTURAL TIMBER ELEMENTS AND ENSURING THAT TERMITE MANAGEMENT RENDERED INVALID IF THE PROPERTY IS NOT MAINTAINED AS INTERNAL RENDERED/PAINTED 5.5 3.9
CONCRETE BLOCKWORK (EXCLUDES RETAINING WALLS):
SYSTEMS ARE NOT BREACHED. RECOMMENDED IN THIS PUBLICATION. BM.1. REINFORCED CONCRETE (R.C.) BLOCKWORK TO CONFORM TO AS 3700
EXTERNAL FACE FINISH 5.0- 5.5 3.5 - 3.9
M.2. THE RECOMMENDED DISTANCE THAT A NEW TREE SHOULD BE LOCATED FROM A P.4. THE LONG TERM PERFORMANCE OF DWELLING FOOTINGS IS DEPENDANT ON H1, H2, EXTERNAL RENDERED/PAINTED MASONRY STRUCTURES. BLOCKWORK SHALL BE CONSTRUCTED IN
4.5 - 5.5 3.2 - 3.5
DWELLING WOULD BE EQUAL OR GREATER THAN 75% OF THE MATURE HEIGHT FACTORS SUCH AS SITE DRAINAGE, VEGETATION AND WATERING OF AREAS H1-D, ACCORDANCE WITH THE PROVISIONS OF AS3700. UNCONFINED
H2-D INTERNAL FACE FINISH 5.0 - 5.5 3.5 - 3.9 CHARACTERISTIC COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNIT,
FOR CLASS M SITES, 100% OF THE MATURE HEIGHT FOR CLASS H1 & H2 SITES, ADJACENT TO THE DWELLING.
150% OF THE MATURE HEIGHT FOR CLASS E SITES. INTERNAL RENDERED/PAINTED 4.5 - 5.0 3.2 - 3.5 f'uc = 15 MPa
P.5. WATERING OF LAWNS AND GARDENS SHOULD BE CONSISTENT. OVER
P, E, E-D REFER NOTE 4 / LOCATIONS - - BM.2. MORTAR TYPE = M3
DRAINAGE NOTES: WATERING CAN DAMAGE FOOTINGS. EQUALLY FOOTINGS MAY BE DAMAGED
BY PROLONGED PERIODS OF NEGLECT AFTER YEARS OF CAREFUL WATERING. NOTES: BM.3. DESIGN CHARACTERISTIC COMPRESSIVE STRENGTH OF GROUT, f'cg = 20 MPa.
D.1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH AS2870. LEAKING TAPS AND PIPES AND BLOCKED DRAINS SHOULD BE REPAIRED 1. AS DEFINED IN AS 2870
PROMPTLY. PROLONGED NEGLECT CAN LEAD TO DAMAGED FOOTINGS. BM.4. YIELD STRENGTH OF REINFORCEMENT - fsy = 500 MPa
D.2. D.2. DRAINAGE SHALL BE CONSTRUCTED TO AVOID WATER PONDING 2. USE MAXIMUM SPACING FOR EXPANSION OR CONTRACTION JOINTS
AGAINST OR NEAR THE FOOTING. THE GROUND IN THE IMMEDIATE VICINITY OF 3. FOR H-D SITES USE THE SHORTER SPACING BM.5. CLEANOUT ALL CORES AFTER EACH DAYS LAYING. JOINTS TO BE TOOLED.
THE PERIMETER FOOTING, INCLUDING THE GROUND UPHILL FROM THE SLAB ON CONTROL JOINTS TO BE PROVIDED AT 6.0 TO 8.0m CENTRES AND AS PER
4. FOR LOCATION OF JOINTS ON CLASS E, E-D & P SITES, REFER TO ENGINEER FOR
BLOCKWALL PLANS WHERE APPLICABLE.
ADVICE

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES GENERAL NOTES LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-001
CONCRETE WORK: BOLTS DENOTED 8.8/S, 8.8/TB AND 8.8/TF ARE HIGH STRENGTH STRUCTURAL
BOLTS OF STRENGTH GRADE 8.8 TO TIMBER NOTES:
C.1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH C.17. ALL REINFORCING BARS SHALL COMPLY WITH AS 4671. ALL FABRIC SHALL
AS 3600 & AS 2870. U.N.O COMPLY WITH AS 4671 AND SHALL BE SUPPLIED IN FLAT SHEETS. AS/NZS 1252 & AS/NZS 4291.1. T.1. MANUFACTURED TIMBER ELEMENTS (e.g. LVL) EXPOSED TO
8.8/S DENOTES BOLTS SNUG TIGHT. WEATHERING SHALL BE L.O.S.P. TREATED TO H3 LEVEL. WHERE
C.2. CONCRETE QUALITY FOR CEMENT TYPE A & EXPOSURE CLASSIFICATION C.18. REINFORCEMENT SYMBOLS: 8.8/TB DENOTES BOLTS FULLY TENSIONED IN BEARING, TO AS 4100. EXPOSED TO DIRECT SUN, FURTHER PROTECTION WITH A GOOD
A1 SHALL BE AS TABULATED AND SHALL BE VERIFIED BY TESTS N - DENOTES GRADE D500 HIGH STRENGTH DEFORMED BARS TO AS 4671. 8.8/TF DENOTES BOLTS FULLY TENSIONED IN FRICTION, TO AS 4100 - MATING QUALITY PAINT SYSTEM IS REQUIRED.
(REFER TABLE BELOW). U.N.O, SEE SLAB PLAN FOR A2, B & C R - DENOTES GRADE R250 HOT ROLLED PLAIN BARS TO AS 4671. SURFACES MUST NOT BE PAINTED.
CATEGORIES. SL - DENOTES HARD-DRAWN WIRE SQUARE REINFORCING FABRIC TO AS T.2. ALL WORK IN STRUCTURAL TIMBER TO BE IN ACCORDANCE WITH THE
4671. S.7. ALL DETAILS, GAUGE LINES ETC. (WHERE NOT SPECIFICALLY SHOWN) ARE TO BE IN CURRENT EDITION OF AS 1684, SAA TIMBER FRAMING CODE AS 1720,
CONCRETE RL - DENOTES HARD-DRAWN WIRE RECTANGULAR REINFORCING FABRIC TO ACCORDANCE WITH AISC PUBLICATIONS "DESIGN CAPACITY TABLES FOR SAA TIMBER ENGINEERING CODE AS 1320 - GLUED LAMINATED
ELEMENT SLUMP AGG COVER U.N.O (mm) STRUCTURAL STEEL" AND "STANDARDISED STRUCTURAL CONNECTIONS". PLATES STRUCTURAL TIMBER
GRADE AS 4671.
L - DENOTES HARD-DRAWN WIRE TRENCH MESH TO AS 4671. ARE TO BE 10mm THICK, CUT FROM STANDARD FLAT BARS U.N.O. ENDS OF HOLLOW T.3. BOLTS: ALL NUTS & BOLTS TO BE PROVIDED WITH WASHERS. ALL
20 TOP SECTIONS SHALL BE SEALED WITH NOMINAL THICKNESS PLATES AND
SLABS ON THE NUMBER IMMEDIATELY FOLLOWING THESE SYMBOLS IS THE BAR BOLTS TO BE TIGHTENED FINALLY BEFORE HANDOVER. BOLT HOLES
100mm 20mm N20 30 BTM. & SIDES DIAMETER IN MILLIMETRES. CONTINUOUSLY WELDED TO SEAL ENDS, UNO. TO BE 2mm OVERSIZE IN UNSEASONED TIMBER.
GROUND
40 TOP (EXT.) C.19. FABRIC/MESH REINFORCEMENT TO BE LAPPED ONE MESH PLUS 30mm. S.8. THE STEEL FABRICATOR SHALL PROVIDE THE ENGINEER WITH 1 COPY OF T.4. UNLESS DETAILED OTHERWISE TIMBER MEMBERS TO BE FIXED WITH
LAPS IN POSITIONS OF MAXIMUM MOMENT ARE NOT PERMITTED. WORKSHOP DRAWINGS FOR INSPECTION AT LEAST 7 DAYS BEFORE FABRICATION NOMINAL NAILING AS SPECIFIED IN AS 1684
FOOTINGS & IS STARTED. STEELWORK IS NOT TO BE FABRICATED UNTIL WORKSHOP DRAWINGS
100mm 20mm N20 50 TYPICAL
PIERS C.20. ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON INSULATED STEEL, ARE APPROVED. T.5. SIZES AND DETAILS NOT SHOWN SHALL COMPLY WITH
30 TOP & SIDES PLASTIC OR CONCRETE CHAIRS GENERALLY AT NOT GREATER THAN 800 AS 1684 ALL OPENINGS TO BE FULLY FLASHED WITH STD GALVANISED
SUSPENDED S.9. ALL DIMENSIONS ARE MILLIMETRES U.N.O.
80mm 20mm N32 CENTRES BOTH WAYS. RODS SHALL BE TIED AT ALTERNATE INTERSECTIONS. SHEET STEEL FLASHING.
SLAB 20 BTM.
C.21. ALL TENSILE REINFORCEMENT TO BE LAPPED AS SHOWN IN TABLE BELOW: S.10. CORROSION PROTECTION T.6. ALL BOLTS TO HAVE MILD STEEL GALVANISED WASHERS :
BEAMS 80mm 20mm N32 45 TYPICAL S.10.1. INTERNAL STEELWORK (ENCLOSED) BOLTS UP TO 12mm DIA - 50x50x3 WASHERS
45 TOP S.10.1.1. THE STEELWORK SHALL BE CLEANED TO AS 1627 CLASS 1 AND GIVEN ONE BOLTS UP TO 20mm DIA - 65x65x5 WASHERS
STAIRS 80mm 20mm N32 REINFORCEMENT BAR N12 N16 N20 N24
35 BTM. LAP LENGTH 400 600 700 800
COAT OF ALKYD PRIMER TO GIVE A DRY FILM THICKNESS OF 50 MICRONS ROOF TRUSS NOTES:
BEFORE DISPATCH TO SITE, UNLESS THE STEEL IS TO BE ENCASED IN
30 SIDES (INT.) CONCRETE OR IS DETAILED OTHERWISE. APPLY ONE FINISH COAT OF ALL RT.1. THE BASIS OF DESIGN SHALL BE SAA LOADING CODE
WALLS 80mm 20mm N32 AS 1170.1; AS 1170.2 & SAA TIMBER STRUCTURE CODE AS 1720.1.
40 SIDES (EXT.) STRUCTURAL STEELWORK NOTES: WEATHER GLOSS ACRYLIC PAINT.
S.10.2. EXTERNAL STEELWORK (UNENCLOSED) RT.2. DESIGN THE ROOF TRUSSES AS PER THE WIND CLASSIFICATION AS
COLUMNS 80mm 20mm N32 40 TYPICAL S.1. DESIGN CONFORMS TO THE FOLLOWING STANDARDS:
SPECIFIED.
AS 4100 - STEEL STRUCTURES. S.10.2.1. ALL STRUCTURAL STEELWORK WHICH IS EXPOSED OR IN CONTACT WITH
C.3. SAMPLE AND TEST IN ACCORDANCE WITH AS 3600. AS/NZS 4600 - COLD-FORMED STEEL STRUCTURES. RT.3. IN ADDITION TO THE NOMINATED PERMANENT BRACING, PROVIDE
EXPOSED BRICKWORK, AND ALL LINTELS, SHALL BE HOT DIP GALVANISED
C.4. ALL CONCRETE CONSTRUCTION TO BE COMPACTED WITH A MECHANICAL FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS AFTER FABRICATION. STEELWORK GALVANISED AFTER FABRICATION ANY ADDITIONAL PERMANENT BRACING REQUIRED FOR STRUCTURAL
VIBRATOR. OF AS 4100. SHALL COMPLY WITH AS/NZS 4680. SUFFICIENCY OF THE TRUSS SYSTEM.
C.5. THOROUGHLY SCABBLE CONCRETE ON WHICH NEW CONCRETE IS TO BE S.2. ALL STEELWORK SHALL BE TEMPORARILY BUT SECURELY BRACED UNTIL ALL S.10.2.2. AS AN ALTERNATIVE TO GALVANISING, ALL STRUCTURAL STEELWORK RT.4. PROVIDE ANY TEMPORARY BRACING REQUIRED TO MAINTAIN THE
POURED. FINAL BRACING, CLADDING AND STABILISING BRICK OR BLOCKWORK HAVE WHICH IS EXPOSED SHALL BE CLEANED TO AS 1627 CLASS 2 1/2 STABILITY OF THE TRUSSES AT ALL STAGES OF ERECTION.
C.6. ALL CONCRETE SHALL BE PLACED AND CURED IN ACCORDANCE WITH BEEN COMPLETED, TO MAINTAIN THE STRUCTURE IN A SAFE AND STABLE PREPARATION AND GIVEN A COAT OF INORGANIC ZINC SILICATE TO GIVE A RT.5. MAKE ALLOWANCES FOR SIZE AND LOCATION OF MECHANICAL
AS3600. WHERE CURING COMPOUNDS ARE USED, IT MUST COMPLY WITH CONDITION DURING CONSTRUCTION. DRY FILM THICKNESS OF 75 MICRONS BEFORE DISPATCH TO THE SITE, SERVICES/AIRCONDITIONING DUCTWORK IF APPLICABLE.
AS3799 & BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS S.3. BASE PLATES SHALL BE GROUTED BEFORE THE MEMBER IS SUBSTANTIALLY UNLESS THE STEEL IS TO BE ENCASED IN CONCRETE OR IS DETAILED RT.6. SPAN TRUSSES ONLY BETWEEN THE NOMINATED SUPPORTS AND
SPECIFICATIONS & AS FOLLOWS: LOADED. GROUT SHALL HAVE A MINIMUM STRENGTH f'c OF 25 MPa AND OTHERWISE. HOLDING DOWN POSITIONS INDICATED.
C.6.1. ONTO SLAB WITHIN 2HRS OF FINISHING OPERATION. SHALL BE DRY PACK MORTAR RAMMED IN, OR AN APPROVED NON-SHRINK S.10.2.3. REPAIR OF GALVANISED COATING AFTER WELDING RT.7. PROVIDE CERTIFICATION FROM A STRUCTURAL ENGINEER, AS DEFINED
GROUT. PREPARATION - REMOVE ALL WELDING SCALE, SLAG & SHARP EDGES.
C.6.2. ONTO WALLS AND COLUMNS IMMEDIATELY AFTER REMOVAL OF IN THE QUEENSLAND BUILDING BY-LAWS, THAT THE ROOF TRUSSES
S.4. U.N.O. ALL MATERIAL SHALL BE: POWER TOOL CLEAN TO AS 1627.2, CLASS 3, USING ABRASIVE WHEEL ON A ARE STRUCTURALLY SUFFICIENT.
FORMWORK.
GRADE 250 HOT-ROLLED PLATES COMPLYING WITH AS/NZS 3678. POLISHER AT 3500RPM. DEGREASE & REMOVE ALL SURFACE
C.7. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED GRADE 300 UB, UC, PFC, EA, UA, FLATS & ROUNDS COMPLYING WITH AS/NZS CONTAMINANTS TO AS 1627.1. CLAY MASONRY NOTES:
FINISHES. 3679.1. CM.1. DESIGN CONFORMS TO AS 3700 - MASONRY STRUCTURES. CONSTRUCT
S.10.2.4. 'SEVERE' CORROSION ENVIRONMENT - APPLY 2 COATS OF 2-PACK EPOXY
C.8. CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE TO THE APPROVAL GRADE 300 WB, WC COMPLYING WITH AS/NZS 3679.2. ZINC TO AS 3750.9, TO TOTAL 150um DFT, FOLLOWED BY 2 PACK EPOXY IN ACCORDANCE WITH THE PROVISIONS OF AS 3700.
OF THE ENGINEER. GRADE C350 CHS COMPLYING WITH AS 1163. ENAMEL TO TOTAL 150um DFT. STRENGTH, f'uc = 12 MPa
C.9. BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS, IF ANY. GRADE C450 RHS, SHS COMPLYING WITH AS 1163. SALT RESISTANCE GRADE = TO AS 3700
S.10.2.5. 'MODERATE' CORROSION ENVIRONMENT - APPLY A TOTAL OF 125um DFT
C.10. HORIZONTAL FORMWORK SHALL BE STRIPPED WHEN APPROVED BY THE S.5. WELDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF AS/NZS 1554.1. OF DULUX METALSHIELD COLD GALV. PRIMER OR EQUIV IN 2 COATS, USING CM.2. MORTAR TYPE = TO AS 3700
ENGINEER. WELDING CONSUMABLES SHALL BE GRADE E48XX OR W50X U.N.O. BRUSH OR SPRAY CAN. NOMINAL THICKNESS = 10mm
ALL WELDS SHALL BE 6mm CFW SP CATEGORY U.N.O. CM.3. CORE-FILLING GROUT TO BRICK PIERS = 20 MPa.
C.11. U.N.O NO ALLOWANCE HAS BEEN MADE FOR STACKED MATERIALS OR ALL BUTT WELDS SHALL BE SP CATEGORY U.N.O. S.11. UNLESS NOTED OTHERWISE, PROTECTIVE COATINGS FOR STEELWORK SHALL BE
MACHINERY ON THE CONCRETE STRUCTURE. INSPECTION IS REQUIRED IN ACCORDANCE WITH AS/NZS 1554.1. AS TABULATED BELOW AND IN ACCORDANCE WITH VOL. 2 PART 3.4.4 OF THE NCC. CM.4. WALL TIES TYPE = MEDIUM DUTY
C.12. NO HOLES OR CHASES OTHER THAN THOSE SHOWN ON THE STRUCTURAL ALL GP / SP WELDS SHALL BE 100% VISUALLY SCANNED. DURABILITY CLASSIFICATION = TO AS 3700
DRAWINGS SHALL BE MADE IN CONCRETE ELEMENTS WITHOUT THE PRIOR SP FILLET WELDS SHALL HAVE 10% VISUAL EXAMINATION U.N.O FIXING = MIN. EMBEDMENT IN MORTAR 50mm. FACE FIXED VENEER
ENVIRONMENT STRUCTURAL MEMBERS (NOT BUILT LINTELS (BUILT
APPROVAL OF THE ENGINEER. SP BUTT WELDS SHALL HAVE 50% VISUAL EXAMINATION U.N.O. TIES TO BE SCREW FIXED.
(EXPOSURE CLASS INTO MASONRY/CONCRETE) INTO MASONRY OR
C.13. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY, IT IS NOT ALL GP WELDS SHALL HAVE 10% VISUAL EXAMINATION. CM.5. JOINTS TO BE TOOLED. CONTROL JOINTS TO BE PROVIDED AS PER
AS PER AS 2312 INTERNAL EXTERNAL CONCRETE)
NECESSARILY SHOWN IN TRUE PROJECTION. S.6. BOLTS SHALL BE M16 DIAMETER U.N.O. FOUNDATION DESIGN ENGINEERING REPORT.
BOLT CATEGORY IS TO BE 8.8/S COMPLYING WITH AS 4100, AS/NZS 1252 & VERY LOW R0 - -
C.14. SPLICES IN REINFORCEMENT MADE IN POSITIONS OTHER THAN SHOWN
SHALL BE TO THE APPROVAL OF THE ENGINEER. WHERE THE LAP LENGTH AS/NZS 4291.1. U.N.O. LOW R0 R1 R2
IS NOT SHOWN IT SHALL BE SUFFICIENT TO DEVELOP THE FULL STRENGTH PROVIDE DESIGN ENGINEER WITH EVIDENCE OF COMPLIANCE WITH THESE
CODES. MEDIUM R0 R2 R3
OF THE REINFORCEMENT.
HOLDING DOWN BOLTS SHALL BE CATEGORY 4.6/S U.N.O. HIGH R1 R3 R4
C.15. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS SHOWN THREADS MAY BE INCLUDED IN THE SHEAR PLANES U.N.O.
ON THE STRUCTURAL DRAWINGS. ALL BOLTS, NUTS AND WASHERS SHALL BE HOT DIP GALVANISED. VERY HIGH R1 R4 R5
C.16. PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER BOLTS DENOTED 4.6/S ARE COMMERCIAL BOLTS OF STRENGTH GRADE 4.6 TO PROTECTIVE COATING SPECIFICATION TO AS 2699.3
TO REINFORCEMENT WITHOUT THE APPROVAL OF THE ENGINEER. AS 1111 SNUG TIGHT.

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES STRUCTURAL NOTES LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-002
USE 225 PODS
SLAB DESIGN SUMMARY (U.N.O)
'bh' BOX HEIGHT (mm) 300 & 225
BOX SIZE (mm) 1090 x 1090
'st' SLAB THICKNESS (mm) 85 USE 300 PODS 100 USE 300 PODS
'od' OVERALL DEPTH (mm) 385 & 310
'bw' BEAM WIDTH (mm) 270
'rw' RIB WIDTH (mm) 100 USE 225 PODS
STEP
SLAB REINF'T SL82
W
100mm RIB REINF'T 1-N12 BTM
2-N12 BTM or
270mm BEAM REINF'T
3-L11TM BTM
REINF'T FOR BEAMS WIDER THAN 300mm PROPOSED MAIN
STEP
WIDTH (mm) TOP BOTTOM DWELLING W

301 - 370 1-N12 3-N12 100 1st REFER TO ATTACHED


371 - 480 2-N12 4-N12 POD
USE 300 PODS RAINWATER UNIT SLAB
481 - 600 3-N12 5-N12 I.B. I.B. I.B. CONNECTION DETAIL
STEP TYPICAL
PIER DESIGN SUMMARY (U.N.O) W

I.B.
MEMBER PIER SPACING (mm)
EDGE BEAMS 2400 & 3600
INTERNAL & STEP BEAMS 2400 x 2400 GRID
INTERNAL RIBS 2400 x 2400 GRID PROPOSED SECONDARY
FOUNDATIONS PIER ∅ (mm) SOCKET DEPTH (mm) I.B. I.B.
DWELLING
STIFF CLAY 450 500
USE 300 PODS
SHALE 400 200
ROCK 300 100

FOOTING DESIGN SUMMARY


FOOTING TYPE DEPTH (df) REINFORCEMENT 100
3-L11TM TOP & BTM
SF1 600mm
WITH R6 TIES @ 900 CRS
4-L11TM TOP & BTM
SF2 600mm
WITH R6 TIES @ 900CRS
NONE (MASS USE 300 PODS
PAD P1 1000mm
CONCRETE)

GEOTECHNICAL INFORMATION
SOIL CLASSIFICATION: P (DESIGN H1)
FOOTING & SLAB NOTES:
SOIL TEST REFERENCE: 3.22.4970.1 F.S.1. CUT/FILL LINE SHOWN IS APPROXIMATE ONLY. IF NOT
SHOWN, SITE SCRAPE SHOULD SUFFICE TO CREATE
DATE: 29/06/2022 BUILDING PLATFORM. IF IN DOUBT PLEASE CONSULT
FOUNDING MATERIAL: VERY STIFF CLAY TREE INFLUENCE NOTE: ENGINEER FOR FURTHER ADVICE.
F.S.2. BUILDER TO CONFIRM SERVICES DO NOT AFFECT
SAFE BEARING CAPACITIES (SWL) LEGEND IN ORDER TO MAINTAIN 'NORMAL' MOISTURE CONDITIONS FOR THE
STRUCTURE BEFORE COMMENCING WORK ON-SITE.
SLAB & FOOTINGS 250 kPa DENOTES 2000mm LONG 3-N12 or 3-L11TM FOOTING & SLAB PLAN LONG TERM SUSTAINABILITY OF THE DWELLING, WE SUGGEST
THAT ANY TREES/ROOT SYSTEMS BE REMOVED FROM THE SITE IF
CONTACT THIS OFFICE IF OTHERWISE.
∅450 WITH A 500 SOCKET INTO CRACK CONTROL BARS, TIED TO UNDERSIDE OF SCALE 1:100 THEY ARE WITHIN THE ZONE OF INFLUENCE OR IN CLOSE F.S.3. SCREW PIERS WITH A MIN. SWL OF 50 kN MAY BE USED
NATURAL MATERIAL (VERY STIFF SLAB TOP MESH. · CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS = 20MPa PROXIMITY TO PROPOSED DWELLING, BACKFILL AND COMPACT AS AN ALTERNATIVE TO BORED PIERS AND AT 2400 CTS.
PIERS FOR HIGHLY OR EXTREMELY REACTIVE SITES ALL SCREW
CLAY) WITH A MIN. CAPACITY OF DENOTES WET AREA SET-DOWN. · 50mm BAR CHAIRS OR 45mm TRIPOD RAILS SHOULD BE USED FOR MESH ROOT SYSTEM AREAS TO COMPLY WITH NOTE F4, DWG S-001
250kPa SHADED AREA DENOTES EXTENT OF SHALLOW DURING THE REMOVAL PROCESS. IF THIS CANNOT BE ACHIEVED PIERS MUST BE FOUNDED BELOW 1.25 x Hs TO COMPLY
W · 4 BAR CHAIRS OR 2 RAILS PER FULL WAFFLE POD
PODS. CONTACT THIS OFFICE PRIOR TO COMMENCING WORK ONSITE AS WITH CLAUSE G 6.3 OF AS2870-2011.
· LAP MESH IN ACCORDANCE WITH DETAIL ON DRG S-201
FURTHER ENGINEERING MAY BE REQUIRED. THIS MAY INCLUDE F.S.4. TERMINATE TO DAMP PROOFING MATERIAL AT FINISHED
EXPOSURE CLASSIFICATION · TOP COVER TO BE FROM TOP OF REINFORCEMENT GROUND OR PAVING LEVEL.
DENOTES EXCAVATION STEP DOWN BUT IS NOT LIMITED TO ADDITIONAL PIERING AND/OR ISOLATION
STRUCTURAL STEEL MEDIUM · DO NOT SCALE OFF ENGINEERING DRAWINGS. IF IN DOUBT, ASK TRENCHES TO ACT AS ROOT BARRIERS. F.S.5 225 PODS MAY BE USED IN WET SET DOWN AREA.

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES FOOTING & SLAB PLAN LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:100 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-101
SLAB DESIGN SUMMARY (U.N.O) 150

DESIGN SUMMARY
BEAM TOP REINFORCEMENT
MAX.

SLAB DESIGN
REFER TO SLAB
'bh' BOX HEIGHT (mm) 300 & 225 (ONLY REQ'D IF SPECIFIED IN

SUMMARY
REFER TO
BEAM TOP REINFORCEMENT N12 OR EQUIVALENT AT ALL RIB SLAB DESIGN SUMMARY)

TABLE
'st'
BOX SIZE (mm) 1090 x 1090 (ONLY REQ'D IF SPECIFIED IN LOCATIONS (1000 LONG) TIED TO TIED TO UNDERSIDE OF MESH.
SLAB DESIGN SUMMARY) TOP MESH WITH THE UNDERSIDE OF SLAB MESH
'st' SLAB THICKNESS (mm) 85 20 TOP COVER

75
TIED TO UNDERSIDE OF MESH. 120 MIN. TOP MESH WITH

'od'
'od' OVERALL DEPTH (mm) 385 & 310 20 TOP COVER IF TILED
40 TOP COVER IF EXPOSED
'bw' BEAM WIDTH (mm) 270
'rw' RIB WIDTH (mm) 100
SLAB REINF'T SL82

MIN.
150
100mm RIB REINF'T 1-N12 BTM G.L.
2-N12 BTM or
270mm BEAM REINF'T
3-L11TM BTM
270 MIN. 100 MIN. 270 MIN. 270 MIN. DAMP-PROOF MEMBRANE 270 MIN.
REINF'T FOR BEAMS WIDER THAN 300mm
'bw' 'rw' 'bw' 'bw' 'bw'
WIDTH (mm) TOP BOTTOM BEAM BTM REINFORCEMENT RIB BTM REINFORCEMENT BEAM BTM REINFORCEMENT BEAM BTM REINFORCEMENT
(REFER TO SLAB DESIGN SUMMARY) (REFER TO SLAB DESIGN SUMMARY) (REFER TO SLAB DESIGN SUMMARY) (REFER TO SLAB DESIGN SUMMARY)
301 - 370 1-N12 3-N12
371 - 480 2-N12 4-N12 TYPICAL EDGE BEAM INTERNAL RIB INTERNAL BEAM - IB STEP BEAM 75 TYPICAL EDGE BEAM
481 - 600 3-N12 5-N12 WITH REBATE PATIO/ALFRESCO EDGE BEAM

N12 OR EQUIVALENT AT ALL RIB

DESIGN SUMMARY
TIMBER FRAME IF REQUIRED
LOCATIONS (1000 LONG) TIED TO

REFER TO SLAB
BEAM TOP REINFORCEMENT (ONLY REQ'D
THE UNDERSIDE OF SLAB MESH

SUMMARY TABLE
IF SPECIFIED IN SLAB DESIGN SUMMARY) 150

DESIGN SUMMARY
SLAB DESIGN
TIED TO UNDERSIDE OF MESH. MAX.

REFER TO
500 LAP

REFER TO SLAB
'st'
TOP MESH WITH
'od'

120 MIN.

75 MAX.

75 MAX.
20 TOP COVER
500 MIN. N12 BAR

'od'
LAP MESH 450mm

175
R6-300 CRS LAP 300

MIN.
150
270 MIN. DAMP-PROOF
'bw' MEMBRANE
BEAM BTM REINFORCEMENT 270 MIN. BEAM BTM REINFORCEMENT BEAM BTM REINFORCEMENT 270 MIN.
USE SHALLOWER PODS
(REFER TO SLAB DESIGN SUMMARY) 'bw' (REFER TO SLAB DESIGN SUMMARY) (REFER TO SLAB DESIGN SUMMARY) 'bw'

TYPICAL EDGE BEAM STEP BEAM 175 MAX. WET AREA SET DOWN WET AREA HOB AT
MESH LAPS NO REBATE
EDGE BEAM
1. MESH IS TO BE LAPPED AS SHOWN BELOW:
a) OVERLAP OF SIDE OF SHEETS
BEAM TOP REINFORCEMENT (ONLY REQ'D
IF SPECIFIED IN SLAB DESIGN SUMMARY)
30 TIED TO UNDERSIDE OF MESH.
GARAGE DOOR REBATE
85 'st'

TO ARCHITECTURAL TOP MESH WITH


MI

b) OVERLAP OF ENDS OF SHEETS SPECIFICATIONS


N.

20 TOP COVER

30
SUMMARY TABLE
SLAB DESIGN

c) OVERLAP SIDE AND END OF SHEETS


REFER TO
'st'

270 MIN. BEAM BTM REINFORCEMENT


30 (REFER TO SLAB DESIGN SUMMARY)
'bw'

d) NOT ACCEPTABLE GARAGE ENTRY EDGE BEAM


WITH 225 PODS & GREATER

NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN


APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES FOOTING & SLAB DETAILS - SHEET 1 LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-201
BEAM TOP REINFORCEMENT (ONLY REQ'D BEAM TOP REINFORCEMENT (ONLY REQ'D
IF SPECIFIED IN SLAB DESIGN SUMMARY) IF SPECIFIED IN SLAB DESIGN SUMMARY)
TIED TO UNDERSIDE OF MESH TIED TO UNDERSIDE OF MESH.
10mm BITUMEN
IMPREGNATED N12-400 CRS 'Z' BARS .
FIBREBOARD 300 LEGS TOP MESH WITH
300 TOP MESH WITH 20 TOP COVER IF TILED
DRIVEWAY SLAB
20 TOP COVER 40 TOP COVER IF EXPOSED
OR PAVERS

SUMMARY TABLE
SLAB DESIGN
G.L.

REFER TO
'st'
MIN.
150
120 DAMP-PROOF MEMBRANE BEAM BTM REINFORCEMENT 100 MIN.
420 (REFER TO SLAB DESIGN SUMMARY)
'rw'
BEAM BTM REINFORCEMENT
(REF. TO SLAB DESIGN SUMMARY) VERANDAH EDGE BEAM
GARAGE ENTRY EDGE BEAM DETAIL NON LOAD BEARING ONLY

FOR DRIVEWAY SLAB OR PAVERS


WITH 225 PODS AND GREATER

NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN


APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES FOOTING & SLAB DETAILS - SHEET 2 LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-202
IN THE EVENT THAT THE SLAB REINFORCEMENTS
RIB REINFORCEMENT NEEDS TO BE CUT DUE TO PIPE PENETRATION
PROVIDE A 600x600 OFF CUT OF MESH AND LAP
& TIE TO SLAB REINFORCEMENT

RIB REINFORCEMENT

200
CUT POD TO SUIT PIPE PROVIDE 1-N12 EXTRA APPROX. 1200
LONG & LAP MIN. 500 EACH END WITH
RIB REINFORCEMENT

SLAB PIPE PENETRATION DETAIL (PLAN VIEW)


N.T.S.

150 150
MAX. MAX.
BEAM TOP REINFORCEMENT BEAM TOP REINFORCEMENT
(ONLY REQ'D IF SPECIFIED IN (ONLY REQ'D IF SPECIFIED IN
SLAB DESIGN SUMMARY) TIED RAINWATER TANK
SLAB DESIGN SUMMARY) TIED
TO UNDERSIDE OF MESH. TO UNDERSIDE OF MESH.
TOP MESH WITH TOP MESH WITH
1-N12 Z-BAR WITH 500 20 TOP COVER 1-N12 Z-BAR WITH 500 20 TOP COVER
LEGS TOP & BTM AT LEGS TOP & BTM AT
EACH END & AT 600 CRS. EACH END & AT 600 CRS.
MIN. 3 BARS WITH A WITH A MIN. 40 COVER
MIN. 40 COVER

SUMMARY TABLE

SUMMARY TABLE
SLAB DESIGN

SLAB DESIGN
MIN.

MIN.
150

150
REFER TO

REFER TO
'st'

'st'
SLAB MESH TOP & BTM DAMP-PROOF SLAB MESH TOP & BTM DAMP-PROOF
WITH 40 COVER * 270 MIN. MEMBRANE WITH 40 COVER 270 MIN. MEMBRANE
*600 MAX. ATTACHED COLUMN 'bw' 'bw'
*1100 MAX. HW, AC UNIT BEAM BTM REINFORCEMENT BEAM BTM REINFORCEMENT
(REFER TO SLAB DESIGN SUMMARY) PIERS ARE ONLY (REFER TO SLAB DESIGN SUMMARY)
REQUIRED WHEN
SHOWN ON PLAN

L=2200 MAX.

ATTACHED COLUMN, HW, AC UNIT & GAS BOTTLE SLAB DETAIL ATTACHED RW UNIT SLAB DETAIL
(NOTE- WHERE ATTACHED SLAB COINCIDES WITH DEEP EDGE BEAM (NOTE- WHERE ATTACHED SLAB COINCIDES WITH DEEP EDGE BEAM
REFER TO TABLE ON SHEET S-204 FOR STEM WIDTH AND EXTRA REINFORCEMENT) REFER TO TABLE ON SHEET S-204 FOR STEM WIDTH AND EXTRA REINFORCEMENT)

NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN


APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES FOOTING & SLAB DETAILS - SHEET 3 LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-203
EXTERIOR WALL AS PER
ARCHITECTURAL PLANS.
BEAM TOP REINFORCEMENT OMIT AT PATIO/ALFRESCO SLAB BEYOND
(ONLY REQ'D IF SPECIFIED IN DEEP EDGE BEAM.
SLAB DESIGN SUMMARY) TIED POD OFF CUTS
TO UNDERSIDE OF MESH OR BACKFILL

EXTRA HORIZONTAL
REINFORCEMENT 1000 MIN.

D=1800 MAX.
(as per table) BEAM BTM
REINFORCEMENT
EXTRA VERTICAL 'C' BARS (REFER TO SLAB
TIED TO UNDERSIDE OF

500 MAX.
DESIGN SUMMARY)
TOP MESH WITH 150 &
600 LEGS AS PER TABLE.
500 MIN.
G.L.
STEP HEIGHTS &

150
LOCATIONS TO BE
N12 (OR EQUIV.) L-BARS @ RIB CONFIRMED ON SITE
LOCATIONS WITH 450 LEGS.
REQUIRED ONLY WHEN 'D' IS CONTROLLED
OR ROLLED FILL
TYPICAL EDGE BEAM STEPPING DETAIL
GREATER THAN 1000 270 MIN.
BEAM BTM REINFORCEMENT 'bw' 225 THICK POD FIXED WITH STAR
LIP AT PATIO/ALFRESCO (REFER TO SLAB DESIGN PICKET AT 2400 CRS. DRIVEN MIN.
DEEP EDGE BEAM SUMMARY) 300 INTO FIRM GROUND

ALTERNATE DEEP EDGE BEAM


NIB
100

(1800 MAX.)

75 MAX.
DRIP GROOVE
R6-300 CRS
10mm GAP FOR HOB AT INTERNAL DEEP
LAP 300
JOINT SEALANT 150 BEAM IF REQUIRED
MAX. LAP 600. TYP
N12 BAR
POD OFF CUTS
EXTRA HORIZONTAL OR BACKFILL POD OFF CUTS LAP 600. TYP EXTRA HORIZONTAL
REINF. AS PER TABLE OR BACKFILL REINF. AS PER TABLE

EXTRA VERTICAL REINF. EXTRA REINFORCEMENT TO DEEP EDGE & DEEP STEP BEAM EXTRA VERTICAL REINF.
Z-BARS WITH 600 & 150 Z-BARS WITH 600 & 150
LEGS AS PER TABLE 150 LEGS AS PER TABLE
EXTRA VERTICAL EXTRA HORIZONTAL
DEPTH 'D' N12 (OR EQUIV.) L-BARS
REINFORCEMENT REINFORCEMENT

'D'
N12 (OR EQUIV.) L-BARS @ RIB LOCATIONS WITH
450 LEGS. REQUIRED
'D'

@ RIB LOCATIONS WITH <400mm - -


450 LEGS. REQUIRED ONLY WHEN 'D' IS
ONLY WHEN 'D' IS GREATER THAN 1000
401mm - 900mm N12 @ 400 CRS N12 @ 400 CRS
GREATER THAN 1000
150 901mm - 1200mm N12 @ 300 CRS N12 @ 400 CRS

1201mm - 1800mm N12 @ 200 CRS N12 @ 300 CRS


MIN.
150

BEAM BTM REINFORCEMENT CONTROLLED CONTROLLED N12 (OR EQUIV.) @ 400 CRS
(REFER TO SLAB DESIGN OR ROLLED FILL OR ROLLED FILL L-BARS WITH 600 & 150 LEGS.
SUMMARY) 270 MIN. 270 MIN.
'bw' 'bw' BEAM BTM REINFORCEMENT
225 THICK POD FIXED WITH STAR 225 THICK POD FIXED WITH STAR
(REFER TO SLAB DESIGN
PICKET AT 2400 CRS. DRIVEN MIN. PICKET AT 2400 CRS. DRIVEN MIN.
300 INTO FIRM GROUND 300 INTO FIRM GROUND SUMMARY)

DEEP EDGE BEAM (1800 MAX.) DEEP STEP BEAM (1800 MAX.)

NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN


APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES DEEP EDGE & DEEP STEP BEAM DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-204
G.L. N12 L-BAR TOP & BTM IN N12 L-BAR TOP & BTM IN
OUTER FACE OF CORNER. OUTER FACE OF CORNER.
BRICKWORK TO BCA 500 LEGS (ONLY REQUIRED 500 LEGS (ONLY REQUIRED
REQUIREMENTS FOR STRIP FOOTINGS) FOR STRIP FOOTINGS)

EXCAVATION DEPTH
Df FOOTING DEPTH
G.L.

(refer plan sheet)

Df + 100
REINFORCEMENT
TOP & BTM
(refer plan sheet)

Df FOOTING DEPTH
(refer plan sheet)
REINFORCEMENT TIES
(refer plan sheet)
300

STRIP FOOTING 'SF1'

G.L.
SLAB BEAM/STRIP FOOTING SLAB BEAM/STRIP FOOTING
CORNER DETAIL (PLAN) INTERSECTION DETAIL (PLAN)

EXCAVATION DEPTH
450x450

Df FOOTING DEPTH
SQUARE OR

(refer plan sheet)

Df + 100
∅450
REINFORCEMENT STEP LENGTH STEP LENGTH
TOP & BTM
ISOLATED PAD DETAIL (P1) (refer plan sheet)
= 1.5 x 'Df' = 1.5 x 'Df'

MAX

MAX
200

200
75 REINFORCEMENT TIES
(refer plan sheet)

'Df' FOOTING DEPTH

'Df' FOOTING DEPTH


450

CONCRETE
75

LEVELING STRIP
STRIP FOOTING 'SF2'
G.L.

ROCK METHOD 'A' METHOD 'B'


3-L11 TM BTM

FOOTING ON ROCK DETAIL STEP LENGTH


= 1.5 x 'Df'

HORIZONTAL
CROSS RODS AS
PER DEB DETAILS

MAX
200

2 x 'Df'
'Df' FOOTING DE
STRIP FOOTING STRIP FOOTING 2-N12 'Z' BARS TOP & BTM.
COG 600 TOP & 250 BTM.

'Df' FOOTING DEPTH


PTH SLOPE < 1:10

3-N12 'U' BARS METHOD 'C'


WITH 200 LEGS
METHOD 'D'

STRIP FOOTING/EDGE STRIP FOOTING/DEEP METHODS FOR STEPPING STRIP FOOTINGS (ELEVATION)
BEND REINFORCEMENT ON SITE TO MAINTAIN COVER
BEAM CONNECTION EDGE BEAM CONNECTION (FOR FOOTING DEPTH REFER TO DWG S-101)

NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN


APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES STRIP FOOTING DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-205
50
REFER SLAB PLAN FOR PIERS MUST BE LOCATED
REINFORCEMENT TYP. UNDER INTERNAL RIBS TYP.
G.L.

450 MIN.

100 100
2-N16x250 LONG INSERTED
40 FROM TOP OF PILE
G.L.
SCREW PILE EMBEDDED
240 INTO FOOTING
SLIDING/BEARING SLIDING/BEARING
PLATE CAP PLATE CAP
300x300
SCREW PIER TYP. SCREW PIER TYP.

TYPICAL SLAB/SCREW PIER CONNECTION DETAIL ISOLATED SCREW PILE PAD


OPTION 1

INTERNAL RIB RIB REINFORCEMENT


TYP TYP
REFER SLAB PLAN FOR

TYP.
75
REINFORCEMENT TYP. 75
TYP.

P. .
-

TY MIN
SCREW PILE

50
G.L. UNDER

SCREW PIER TYP. SCREW PIER TYP.

SECTION Y
SCALE 1:20 -
PRIVATE SERVICE TRENCH NOTES
TYPICAL SLAB/SCREW PIER CONNECTION DETAIL LOCAL THICKENING AT ST.1. PLUMBING AND DRAINAGE TRENCHES SHALL
OPTION 2 INTERNAL PILE LOCATIONS BE LOCATED OUTSIDE THE INFLUENCE OF THE
FOOTINGS. THE HORIZONTAL DISTANCE TO ANY
G.L. TRENCH EXCAVATION MUST BE GREATER THAN
THE TRENCH DEPTH IN ACCORDANCE WITH
CLAUSE 6.3 FROM AS 2870-2011. THIS
REFER SLAB PLAN FOR PIERS MUST BE LOCATED HORIZONTAL CLEARANCE TO BE INCREASED
REINFORCEMENT TYP. UNDER INTERNAL RIBS TYP. MORE THAN TWICE THE TRENCH DEPTH FOR
SAND SITES. FOOTING PIERS WILL BE
NECESSARY UNDER ALL EDGE BEAMS IF THESE

SERVICE TRENCH
CONDITIONS ARE NOT MET.
ST.2. TRENCH BACKFILL SHALL BE COMPACTED IN
ACCORDANCE WITH CLAUSE 5.5 OF AS/NZS
3500.2-2003 OR CLAUSE 7.2.13 OF AS/NZS
G.L. 45° 3500.3-2003. SAND BEDDING AND SURROUND
1
ZONE OF INFLUENCE SHALL BE BLOCKED WITH A CLAY PLUG
PROVIDE BONDBREAKER PROVIDE BONDBREAKER 1 45° FOR CLAY WHEREVER TRENCHES PASS UNDER THE EDGE
FOR PIERS >1.0m DEEP FOR PIERS >1.0m DEEP 30° FOR SAND OF ANY SLAB.
30°
CONC. BORED PIER CONC. BORED PIER 1
REFER TO SLAB PLAN FOR REFER TO SLAB PLAN FOR
2
LOCATION & SIZE. TYP. LOCATION & SIZE. TYP.

TYPICAL SLAB/BORED PIER CONNECTION DETAIL


PRIVATE SERVICE TRENCH DETAIL

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES PIERING DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-206
MAX 1 IN 3 BATTER. OTHERWISE
LOW RETAINING WALL REQUIRED
AT TOE OF BATTER. (TYPICAL)
SURFACE DRAINAGE NOTES:
BLOCKOUT IN FOOTING LAGGING THICKNESS AS PER TABLE, PIPE PLACEMENT
APPROX. 2x PIPE ∅ SQ. PENETRATION OF THE EDGE BEAM BY S.D.1. CLAUSE 3.1.2.3 OF VOLUME 2 OF THE NATIONAL CONSTRUCTION
PLUMBING SHALL BE SLEEVED ZONE A REFER DETAIL 1 CODE (NCC) REQUIRES THAT THE FINISHED HEIGHT OF ANY SLAB
ZONE A

= = =
1000 EDGE BEAM BE A MINIMUM OF 150mm, GENERALLY, ABOVE THE FINISHED
ZONE B NO THICKENING REQ'D

'OD'
ZONE B GROUND LEVEL AFTER LANDSCAPING, AND THAT THE EXTERNAL
ZONE C ZONE C REFER DETAIL 2 SURFACE DRAINS AWAY WITH A MINIMUM OF 50mm FALL OVER

'D'
THE FIRST METRE. IT SHOULD ALSO BE NOTED THAT CLAUSE
FFL 1 in 20 4.6.6.6 OF AS/NZS 3500.2-2003 REQUIRES THAT THE TOP OF THE
OVERFLOW RELIEF GULLY BE A MINIMUM OF 150mm BELOW THE

Max.
200
TRENCH MESH MINIMUM REQUIREMENTS FOR LAGGING LOWEST GRATE IN THE SLAB AND 75mm ABOVE THE FINISHED
FFL AT LEAST 150mm
ABOVE FGL 50mm BTM. COVER THICKNESS GROUND LEVEL.
'3D' S.D.2. FINISHED GROUND AND FLOOR LEVELS SHALL BE AS SHOWN IN
SITE MINIMUM LAGGING THICKNESS
THIS AREA MUST DRAIN THE TYPICAL SURFACE DRAINAGE DETAILS ON THIS PAGE AND
CLASS (mm)
THE FOLLOWING REQUIREMENTS:
AWAY AT A GRADE NOT EDGE BEAM THICKENING DETAIL 1
LESS THAN 1 IN 150. "M" 20 S.D.2.1. DURING CONSTRUCTION, SURFACE WATER SHALL BE DIVERTED
(TYPICAL) "H1" 20 AWAY FROM FOOTINGS TO A LAWFUL POINT OF DISCHARGE.
"H2" 40 S.D.2.2. THE FINISHED SURFACE OF ANY GROUND, INCLUDING
PATHWAYS AND DRIVEWAYS, SHALL BE GRADED AWAY FROM
TRENCH MESH LAGGING THICKNESS, (MIN. 40mm) "E" 40
1000 ANY FOOTING, SLAB OR BASEMENT RETAINING WALL A
50 BTM. COVER PENETRATION OF THE EDGE BEAM BY "P" 40 MINIMUM OF 50mm OVER THE FIRST METRE.
50mm min. PLUMBING SHALL BE SLEEVED S.D.2.3. THE GROUND SHALL THEN BE GRADED AROUND THE
EDGE BEAM
STEP BUILDING SUCH THAT SURFACE WATER WILL DRAIN AWAY
1 in 20 1 in 150 MINIMUM REQUIREMENTS FOR EXPANSION & FROM THE BUILDING TO A LAWFUL POINT OF DISCHARGE.

75
FFL

'D'
ALLOWABLE ROTATION IN FITTINGS S.D.2.4. THE GROUND SHALL ALSO BE SHAPED SUCH THAT NO
PONDING OF SURFACE WATER CAN OCCUR.
FFL AT LEAST 150mm CONCRETE PATIO MINIMUM REQUIRED ALLOWABLE S.D.2.5. WHERE DRAINAGE PITS ARE INSTALLED TO DRAIN SURFACE
SITE CLASS
ABOVE FGL 100mm min. ALT. TO 2 LAYERS OF EXPANSION JOINT CAPACITY ROTATION WATER AWAY, GRATED INLET PITS SHALL BE INSTALLED WITH
1000 Min. MESH, BEND THE SINGLE PIPES DRAINING TO A LAWFUL POINT OF DISCHARGE. PITS
LAYER AND MAINTAIN "H1" & "H2" 80mm 15° AND PIPES SHALL BE DESIGNED AND CONSTRUCTED IN
EDGE BEAM THICKENING DETAIL 2 75mm SEPARATION "E" 150mm 15° ACCORDANCE WITH AS/NZS 3500.3-2003. DRAINAGE PITS MAY
DISTANCES NEED TO BE INSTALLED TO ALLOW SURFACE WATER TO DRAIN
"P/H1 OR H2" 80mm 15° AWAY IN AREAS WHERE THE DISTANCE FROM A FOOTING TO A
1000 PLUMBING PIPE PENETRATION DETAILS "P/E" 150mm 15° BOUNDARY OR ADJACENT STRUCTURE, EG FENCE, IS LESS
THAN 1.0m.
S.D.2.6. THE FINISHED FLOOR LEVEL OF ANY GARAGE OR CARPORT
SHALL ALSO BE SET SUCH THAT DRIVEWAY SLOPES COMPLY
ROOFED
WITH AS/NZS 2890.1-2004. REFER TO THE TYPICAL DRIVEWAY
PATIO
DETAILS ON THIS PAGE.
S.D.3. RETAINING WALLS SHALL BE INSTALLED AT THE BASE OF CUT AND
FFL 1 in 150 1 in 20 FILL BATTERS WHERE BATTER SLOPES EXCEED 1:3. RETAINING
WALLS ARE ALSO REQUIRED WHERE CUTTING BELOW THE BASE OF
AN EXISTING RETAINING WALL AND WHERE AN ADDITIONAL
FFL AT LEAST 150mm CONCRETE PATIO SURCHARGE IS PLACED ABOVE AN EXISTING RETAINING WALL.
ABOVE FGL 100mm min.

FFL
1 in 150 1 in 150
STRAPS NOT REQ'D IN CUT

FILL TO ENSURE WATER RUNOFF STRAPS REQ'D IF UNCONTROLLED FILL IS IN


UNDER BUILDING EXCESS OF 600mm

TYP. SURFACE DRAINAGE DETAILS PLUMBING & DRAINAGE STRAPS


FFL - FINISHED FLOOR LEVEL FFL - FINISHED FLOOR LEVEL
FGL - FINISHED GROUND LEVEL

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES SURFACE DRAINAGE DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:20 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-207
HORIZONTAL EXPANSION JOINT
· REQUIRED DOWNSTREAM AT EACH
PLUMBING CONNECTION NOTES: REQUIRED TO BE DESIGNED & CONSTRUCTED IN ACCORDANCE WITH AS/NZS
3500 PART 5.
JUNCTION, CHANGE IN GRADE &
CHANGE IN DIRECTION AS PER AS 3500 P.1. THE FOLLOWING NOTES & DETAILS PROVIDED ARE A GUIDE ONLY FOR P.9. THE USE OF CORRUGATED FLEXIBLE PVC PIPE PRODUCTS SHOULD BE
· REFER TO AS 3500 & LOCAL COUNCIL ARTICULATION FOR SANITARY PLUMBING, DRAINAGE & SHOULD BE READ IN AVOIDED ON CLASS H & E SITES AS THEY ARE NOT ABLE TO EXPAND
REQUIREMENTS FOR MAXIMUM CONJUNCTION WITH AS/NZS 3500, AS 2870 & ANY OTHER RELEVANT LONGITUDINALLY TO ACCOMMODATE POTENTIAL VERTICAL & LATERAL
SPACING BETWEEN JOINTS. STANDARD & OTHER REQUIREMENTS OF THE NCC. MOVEMENTS AT THE SLAB OR FOOTING EDGE UNLESS SPECIFICALLY
P.2. ALL SEWER & STORMWATER TO BE CONSTRUCTED IN ACCORDANCE WITH DETAILED BY THE MANUFACTURER.
AS/NZS 3500 & THE REQUIREMENTS OF AS 2870 SECTION 5: CLAUSE 5.6 & P.10. SEPTIC TANKS & ASSOCIATED SOAKAGE AREAS SHOULD BE LOCATED TO
G.L. SECTION 6: CLAUSE 6.6: FOR SLAB OR STRIP FOOTINGS ON HIGHLY AND MINIMISE SOIL MOISTURE INCREASES WITHIN THE FOUNDATION.
EXTREMELY REACTIVE SITES, THE FOLLOWING REQUIREMENTS APPLY: P.11. ALL PIPEWORK INCLUDING STORMWATER FITTINGS & ADAPTERS SHOULD BE
DRAINS ATTACHED TO OR EMERGING FROM UNDERNEATH THE BUILDING PROTECTED FROM MECHANICAL DAMAGE.
SHALL INCORPORATE FLEXIBLE JOINTS IMMEDIATELY OUTSIDE THE FOOTING
P.12. TERMITE PROTECTION NOT SHOWN ON THESE DRAWINGS AS THERE ARE
CLAY PLUG VERTICAL EXPANSION JOINT AND COMMENCING WITHIN 1m OF THE BUILDING PERIMETER TO
VARIOUS OPTIONS. REFER TO THE BUILDING DESIGNER.
· MAY BE REPLACED WITH SWIVEL/EXPANSION ACCOMMODATE A TOTAL RANGE OF DIFFERENTIAL MOVEMENT IN ANY
COMBINATION SWIVEL-EXPANSION JOINT DIRECTION EQUAL TO THE ESTIMATED CHARACTERISTIC SURFACE MOVEMENT P.13. ALL DETAILS ARE INDICATIVE ONLY. DESIGN OF PATHS FOOTINGS ETC. &
COMBO JOINT IF DISTANCE BETWEEN BOTTOM
TO BE INSTALLED WITHIN 1000mm OF OF THE SITE (Ys). IN THE ABSENCE OF SPECIFIC DESIGN REQUIREMENTS, THE LOCATION OF PENETRATIONS TO BE SPECIFIED BY AN ENGINEER.
· OF SLAB & TOP OF PIPE IS < 500mm
DWELLING PERIMETER · WHERE DRAINAGE PIPE IS PENETRATING FITTINGS OR OTHER DEVICES THAT ARE PROVIDED TO ALLOW FOR THE P.14. PROVISIONS SHOULD BE MADE FOR THE CONNECTION OF OVERFLOW OR
· MAY BE REPLACED WITH A SERIES OF THROUGH CONCRETE BEAMS, VERTICAL MOVEMENT SHALL BE SET AT THE MID POSITION OF THEIR RANGE OF WATER DISCHARGE FROM FIXTURES SUCH AS HOT WATER SYSTEMS & AIR
SWIVEL & EXPANSION JOINTS OF EXPANSION JOINTS ARE NOT REQUIRED. POSSIBLE MOVEMENT AT THE TIME OF INSTALLATION, SO AS TO ALLOW FOR CONDITIONERS TO A DRAIN AS REQUIRED BY THE RELEVANT LOCAL
SERVICE PIPE
EQUIVALENT ALLOWABLE MOVEMENT MOVEMENT EQUAL TO 0.5YS IN ANY DIRECTION FROM THE INITIAL SETTING. AUTHORITY.
THIS REQUIREMENT APPLIES TO ALL STORMWATER AND SANITARY P.15. EXPANDABLE JOINT & SWIVEL SPECIFICATIONS:
TYP. UNDER SLAB EDGE DETAIL P.3.
PLUMBING DRAINS AND DISCHARGE PIPES.
PLUMBING & DRAINAGE UNDER THE SLAB SHOULD BE AVOIDED WHERE
P.15.1. TO BE MANUFACTURED AND COMPLY WITH AS 1280 AND AS 1415.
(ELEVATION VIEW) P.15.2. TO BE INSTALLED AS PER MANUFACTURES SPECIFICATIONS AND
PRACTICAL (REFER AS/NZS 3500 CLAUSE 4.10) INSPECTED BY THE LOCAL AUTHORITY.
P.4. GRADES IN PIPEWORK ON 'M', 'H', 'E' & 'P' SITES SHOULD HAVE A MINIMUM
GRADE OF 1:30 WITHIN 1.5 METRES OF THE BUILDING & 1:60 ELSEWHERE. P.15.3. SEWER PIPES FOUNDED WITHIN THE FILLED SECTION OF THE
GRADES IN FLEXIBLE FITTINGS TO BE SET AT THE MINIMUM GRADE. BUILDING PAD UNDER THE SLAB ARE TO BE HUNG FROM SLAB
P.5. ALL EXPANSION & ARTICULATION JOINTS TO BE INSTALLED IN ACCORDANCE REINFORCEMENT WITH METAL STRAPS.
WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL JOINTS TO BE SET MID P.15.4. TO ENSURE CORRECT PLUMBING CONNECTIONS ARE INSTALLED IT IS
POINT SO AS TO ALLOW FOR MAXIMUM MOVEMENT IN EITHER DIRECTION. ESSENTIAL THAT A COPY OF THIS REPORT AND ANY RELEVANT
DOWNPIPE ADDITIONS (WHERE APPLICABLE) ARE SUPPLIED TO THE PLUMBER
P.6. STORMPLASTICS (SA) PTY LTD "SWIVEL JOINTS" SHOULD NOT BE USED AS A
BEND TO ACHIEVE CORRECT FALLS. THE JOINTS SHOULD BE SET IN A PRIOR TO THEIR PREPARATION.
STRAIGHT LINE OF THE DRAIN TO ALLOW MAXIMUM (+) OR (-) MOVEMENT. A P.15.5. IT IS ALSO ADVISABLE THAT SLAB DOCUMENTATION IS AVAILABLE
MINIMUM 15° BEND TO BE INSTALLED BEFORE SWIVEL JOINTS TO ACHIEVE ON-SITE FOR REFERENCE BY THE PLUMBERS AND NOMINATED
DOWNPIPE EXPANSION JOINT OR MINIMUM GRADES FROM THE FACE OF THE FOOTINGS. INSPECTORS.
OVERSIZE COUPLING TO ALLOW P.7. DETAIL & SUPPORT OF TRAPS AT THE O.R.G. TO BE CONSIDERED ON SITE, TO
FOR VERTICAL MOVEMENT ALLOW FOR POTENTIAL MOVEMENTS INCLUDING ISOLATION AND
(REFER TABLE IF REQUIRED) ARTICULATION ASSOCIATED WITH PATHS & PAVEMENTS. THE O.R.G. SHOULD
G.L.
BE CAST IN CONCRETE MONOLITHICALLY WITH THE FOOTING SYSTEM ON
CLASS 'H' & 'E' SITES.
P.8. STORMWATER SYSTEMS THAT COLLECT ROOFWATER & SURFACE WATER ARE

STORMWATER
DRAINAGE PIPE TYP. STORMWATER DETAIL

MINIMUM PLUMBING RECOMMENDATIONS


SITE/DESIGN CLASSIFICATION

COMPONENT A&S M H1 H2 E P* M-D H-D E-D


HORIZONTAL PENETRATION LAGGING (mm) 20 20 40 40 40 40 40 40
IMPORTANT NOTE: û
JOINT EXPANSION SIZE (mm) û û 100 100 150 150 100 150 150-220
THESE RECOMMENDATIONS ARE A GUIDE ONLY. VERTICAL EXPANSION JOINTS (UNDER SLAB) û û û û ü ü û û ü
FINAL PLUMBING REQUIREMENTS TO BE SWIVEL JOINTS û û ü ü ü ü ü ü ü
DETERMINED BY LOCAL PLUMBING AUTHORITY DOWNPIPE EXPANSION JOINTS û û ü ü ü ü ü ü ü
IN CONJUNCTION WITH AS/NZS 3500
GULLY PITS FOR HOSE COCKS & AC UNITS û û ü ü ü ü ü ü ü
* 'P' CLASSIFICATION PLUMBING REQUIREMENTS ARE SPECIFIC TO UNCONTROLLED FILL ONLY

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES PLUMBING CONNECTION DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-208
REFER TO TYPICAL
MASTIC SEALANT DETAIL WALL TIES @ 300 CRS
VERTICALLY

STUD FRAME

300 300
PLASTER MAX. MAX.
BOARD
NOTE: MAXIMUM BRICK TIE FIXING DISTANCE
IS 300mm FROM THE ARTICULATION JOINT.

MASONRY VENEER WALL JOINT DETAIL PROPOSED MAIN


DWELLING

REFER TO TYPICAL
MASTIC SEALANT DETAIL

10mm THICK LINE OF TIES EACH


RENDER SIDE OF JOINT EVERY PROPOSED SECONDARY
2 N# RENDERED PLASTER
3rd COURSE HEIGHT DWELLING
STOPPING BEADS
(EXANGLE R11 BY 'RONDO')

MASONRY CAVITY WALL JOINT DETAIL

10 MOULDING TO CONCEAL
ARTICULATION JOINT
MASTIC SEALANT

MASONRY EXPANSION TIE


FIXED TO WALL/FRAME ∅12 FOAM
BACKING ROD ARTICULATION MARKING PLAN
SCALE 1:100
WALL TIES @ 300 CRS
WINDOW/DOOR REFER TO TYPICAL
VERTICALLY
FRAME MASTIC SEALANT DETAIL
JOINT TO BE
10 THICK.
MASTIC SEALANT
STUD FRAME
LEGEND
DENOTES APPROX. LOCATION OF ARTICULATION
PROVIDE ∅2.6x150LG GALV. PINS
PLASTER JOINTS IN THE MASONRY WALLS (DO NOT SCALE).
CENTRALLY ACROSS JOINT EVERY 3RD
BOARD ACHRITRAVE TO CONCEAL ∅12 FOAM EXACT LOCATION OF ARTICULATION JOINTS SHOULD
COURSE OR USE MFA3 ANCHOR OR
JOINT INTERNALLY BACKING ROD BE READ OFF ARCHITECTURAL DRAWINGS. ALL
SIMILAR ACROSS EVERY 6TH COURSE
ARTICULATION JOINTS SHALL BE CONSTRUCTED FOR
THE FULL HEIGHT OF THE WALL. REFER TO DETAILS.
MASONRY VENEER WALL JOINT DETAIL SINGLE SKINNED WALL JOINT DETAIL TYPICAL MASTIC SEALANT DETAIL
BESIDE OPENINGS
NOTE - FOR ALL REINFORCEMENT REFER TO FOOTING & SLAB PLAN
APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.
GERVASE PURICH TORO HOMES MASONRY ARTICULATION DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-209
MEMBER SCHEDULE
MARK MEMBER SIZE COMMENTS
B1 700 6.0 kN/m PLYWOOD BRACING PANEL (SEE DETAIL TYPE 'B')
B2 1200 6.0 kN/m PLYWOOD BRACING PANEL (SEE DETAIL TYPE 'B')
B3 1800 3.0 kN/m TENSIONED METAL STRAPPING (SEE DETAIL 'TMS')

B2

B3
B3

B1

B2
B3

B3
PROPOSED MAIN
DWELLING

B3

B1
B3

B3
B3
PROPOSED SECONDARY
DWELLING B3
B1

B1
WIND BRACING NOTES:
W.1. BRACING PANELS, INCLUDING FIXINGS AT TOP & BOTTOM
B2

B2
ARE TO BE CONSTRUCTED IN ACCORDANCE WITH
B2 B1 MANUFACTURER'S SPECIFICATION AND AS 1684-2010.
W.2. CONSTRUCTION BRACING: 40% OF BRACING TO BE IN PLACE
BEFORE ROOFING IS INSTALLED.
REQUIRED = 43kN
A PROVIDED = 57.0kN W.3. STRUCTURAL PLY SHEET BRACING IN ACCORDANCE WITH
AS 1684-2010. PLYWOOD BRACING PANELS LESS THAN
900mm IN WIDTH ARE TO HAVE ADDITIONAL FIXINGS OF
1-M10 COACH SCREW AT EACH CORNER OF THE PANEL OR
M12 RODS EACH END.

N2 W.4. PLYWOOD BRACING (6kN/m RATING) FIXED IN ACCORDANCE


WITH AS 1684 (TABLE 8.18 H ).
W.5. DOUBLE BRACED WALLS TO HAVE M16 RODS EACH END.
WIND BRACING PLAN W.6. CEILING DIAPHRAGM ACTION IS REQUIRED TO DISTRIBUTE
REQUIRED = 36kN
B PROVIDED = 48.60kN SCALE 1:100 LOADS TO BRACING WALLS. CEILING BATTENS TO BE
· ALL FRAMING TIE DOWN & CONNECTION DETAILS TO DIRECTLY FIXED TO THE TRUSSES OR RAFTERS. HANGING
COMPLY WITH AS1684.2 FOR N2 WIND CLASSIFICATION BRACKET WILL NOT BE PERMITTED UNLESS THE BRACKET IS
BRACING WIND AXIS · TIE DOWN ALL FRAMING IN ACCORDANCE WITH TABLE 9.4A CERTIFIED BY THE MANUFACTURER, SPECIFICALLY THAT IT
3.21.4970.1 ON SHEET S-402 WILL NOT AFFECT THE CEILING DIAPHRAGM.
WIND CLASS REFERENCE: W.7. ALL PLY BRACE TO BE INSTALLED IN VENEER CAVITY WHERE
DATE: 29/06/2022
POSSIBLE.

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES WIND BRACING PLAN LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - 1:100 @ A3 TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-301
30 x 0.8mm GALV. METAL STRAP LOOPED OVER
VERTICAL BUTT JOINTS PLATE AND FIXED TO STUDS WITH 4/30 x ∅2.8mm
PERMITTED PROVIDED FIXED TO GALV. FLAT HEAD NAILS (OR EQUIV.) TO EACH END.
50 NOGGING AT 50mm CRS 40 STAGGERED
ALTERNATIVELY, PROVIDE SINGLE STRAPS TO
50 BOTH SIDES, WITH FOUR (4) NAILS PER STRAP END,
∅2.8 FH NAILS AT 9mm FROM EDGE OR EQUIV. ANCHORS OR OTHER FASTENERS.
OF SHEET AND: 50 CRS TOP & BTM VERTICAL BUTT JOINTS
PLATE, 150 CRS VERTICAL EDGES & PERMITTED PROVIDED FIXED TO
300 CRS INTERMEDIATE STUDS NOGGING AT 50mm CRS
30 x 0.8mm TENSIONED METAL STRAP FIXED TO
STUDS WITH ONE (1) 30 x ∅2.8mm GALV. FLAT-HEAD
MINIMUM PLYWOOD THICKNESS NAIL (OR EQUIV.) AND TO PLATES WITH 4/30 x
∅2.8 FH NAILS AT 9mm FROM EDGE OF
150 (mm) SHEET AND: 50 CRS TOP & BTM PLATE,
∅2.8mm GALV. FLAT HEAD NAILS, OR ALTERNATIVE
150 CRS VERTICAL EDGES & 300 CRS
METAL STRAP, FIXED AS ABOVE, WITH A NET 150
PLYWOOD STUD STUD INTERMEDIATE STUDS
SECTIONAL AREA OF NOT LESS THAN 21mm²
STRESS SPACING SPACING
GRADE 450mm 600mm
BRACING PANELS CONNECTED TO FLOOR WITH
F8 7mm 9mm A FULL HEIGHT M12 THREADED ROD AT EACH
150
F11 6mm 7mm END FIXED TO SLAB WITH RAMSET CHEMSET
F14 4mm 6mm REO 502 EMBEDDED 100mm. (FOR FIRST FLOOR
BRACING PANELS REFER TO DETAIL A OR B)
F27 4mm 4.5mm
40 STAGGERED
FIX BTM PLATE TO FLOOR FRAME OR SLAB,
. to WITH NOM. FIXING REQUIREMENT.
300 BRACING PANELS CONNECTED TO SLAB WITH A M12
m MIN X.
CHEMICAL ANCHOR FIXED WITH RAMSET CHEMSET REO 502 0m MA
(OR EQUIVALENT) EMBEDDED 70mm. ANCHORS PROVIDED 180 0mm
27 0 460mm MIN. HARDWOOD/
AT EACH END AND INTERMEDIATELY @1200CTS MAX. (FOR 600mm MIN. PLYWOOD
FIRST FLOOR BRACING PANELS REFER TO DETAIL A OR B)
TYPICAL BRACING WALL (PLY/HARDBOARD)
TYPICAL BRACING WALL (PLY) TYPE B TENSIONED METAL STRAPPING (TMS) TYPE E
NTS NTS NTS
READ IN CONJUNCTION WITH AS 1684 TABLE 8.18(h) USING METHOD B READ IN CONJUNCTION WITH AS 1684 TABLE 8.18(d) READ IN CONJUNCTION WITH AS 1684 TABLE 8.18(n) USING TYPE E (HARDBOARD)
(6.0 kN/m RATING FOR 2.7m HIGH WALLS) (3.0 kN/m RATING FOR 2.7m HIGH WALLS) OR 8.18(h) USING METHOD A (PLYWWOOD)
(6.4 kN/m RATING FOR 2.7m HIGH WALLS)
MIN. HARDBOARD THICKNESS 4.8mm

150 x 50 NOGGING, MIN.


FIXED WITH 1/FRAMING
FIX EACH BLOCK 38 THICK BLOCKING ANCHOR EACH END
TRUSS/RAFTER/JOIST 2-M10 BOLTS
WITH 2-M10 BOLTS
EACH SIDE NOTE: PROVIDE GAP BETWEEN NOM. SEASONED TIMBER BRACING WALL
TOP PLATE & ROOF MEMBERS BLOCKING PIECE BRACING WALL
TO ALLOW FOR DEFLECTION ON TOP OF I-JOIST
BLOCKING PIECES
LARGE ENOUGH TO BRACING NAILS TO LOCATE

90
AVOID SPLITTING WALL BRIDGING MEMBER
HARD UNDER TOP
TRUSS/RAFTER/JOIST FLANGE AS SHOWN
2/30 x 0.8 GI STRAPS, 90 x 70 F8
EXTERNAL 6/2.8 dia NAILS SEASONED TIMBER WASHER & 100
BRACING WALL I-JOIST 70 x 35 MGP10
WALL EACH END OF STRAP BRIDGING MEMBER M12 BOLT MAX
BRACING WALL WEB STIFFENER
WALL PERPENDICULAR TO TRUSS/RAFTER/JOIST WALL PARALLEL TO TRUSS/RAFTER/JOIST INTERNAL WALL TO EXTERNAL WALL WALL TO JOIST BRIDGING CONNECTION WALL TO JOIST CONNECTION
DETAIL A DETAIL B

TYPICAL BRACING WALL CONNECTION DETAILS


NTS
READ IN CONJUNCTION WITH AS 1684

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES WIND BRACING DETAILS LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A
TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-401
TABLE 9.4 A: TABLE 9.4 B:
THE FOLLOWING CALCULATIONS ARE BASED ON AND TAKEN FROM: NOMINAL FIXINGS FOR TIMBER MEMBERS
A) BUILDING CODE OF AUSTRALIA &
B) AS 1684.2 - 2010 RESIDENTIAL TIMBER - FRAMED CONSTRUCTION.
N2 SHEET ROOF, 7500 ULW, TRUSSES @ 600 C/C, BATTENS @ 900 C/C FLOOR FRAMING
4/75 x 3.33mm or 5/75 x 3.05mm MACHINE - DRIVEN NAILS PLUS
TIEDOWN MEMBER TABLE No. UPLIFT FORCE FIGURE No. ALLOW LOAD (kN) DESCRIPTION/TYPE OF FIXING 1/30 x 0.8mm G.I. STRAP OVER BEARER AND FIXED BOTH ENDS TO STUMP
BATTEN TO TRUSS OR 1/75mm NO. 14 TYPE 17 SCREW - GENERAL WITH 4/22.8mm ∅ EACH END, OR
9.14 0.53 / 1.0 TABLE 9.25 d 4.5 BEARER TO TIMBER STUMP/POST
RAFTER, GENERAL/EDGES AND EDGES. 1/M10 BOLT THROUGH BEARER HALVED TO STUMP, OR
1/M12 CRACKED BOLT FIXED VERTICALLY THROUGH BEARER AND BOLTED
TRUSS OR RAFTER TO TOP 30x0.8mm G.I. LOOP STRAPS, 4/2.8∅ NAIL PER TO STUMP PLUS 4/75 x 3.33mm or 5/75 x 3.05mm MACHINE - DRIVEN NAILS.
9.13 3.3 TABLE 9.21 e 13
OF PLATE END LOOPED UNDER TOP PLATE. BEARER TO MASONRY
1M10 BOLT OR 1/50 x 4mm MILD STEEL BAR FIXED TO BEARER WITH M10 BOLT AND CAST
30x0.8 G.I. STRAP LOOPED OVER PLATE. NAILED COLUMN/WALL/PIER (EXCLUDING
TOP & BOTTOM WALL INTO MASONRY (TO FOOTING).
9.13 7.4 TABLE 9.19 d 8.4 TO STUDS AT EACH END WITH 6/2.8∅ NAILS MASONRY VENEER CONSTRUCTION)
PLATES TO STUDS
EACH END @ MAX 1350 CTS. BEARERS TO CONCRETE
1/6mm ∅ ROD CAST INTO STUMP, VERTICALLY THROUGH BEARER AND BENT OVER.
STUMP/POST
BEAMS/LINTELS TO
M10 ANCHOR RODS LINTEL TO SLAB/FLOOR BEARERS TO STEEL POST 1/M10 COACH SCREW OR BOLT.
STUDS/POSTS/BOTTOM
9.13 9.9 TABLE 9.18 d 15 FRAME AND TOP PLATE M10 TO LINTEL WITHIN
PLATES
100mm OF TRUSS/RAFTER.
OPENINGS < 1800 FLOOR JOIST TO BEARER 2/75 x 3.05mm ∅ NAILS.
BEAMS/LINTELS TO WALL FRAMING
M12 ANCHOR RODS LINTEL TO SLAB/FLOOR
STUDS/POSTS/ BOTTOM
9.13 16 TABLE 9.18 d 20 FRAME AND TOP PLATE M12 TO LINTEL WITHIN
PLATES,
100mm OF TRUSS/RAFTER. PLATES UP TO 38mm THICK -2/75mm x 3.05mm NAILS THROUGH PLATE.
OPENINGS < 3000
PLATES TO STUDS PLATES UP 38 TO 50mm THICK -2/90mm x 3.05mm NAILS THROUGH PLATE,
OR 2/75mm x 3.05mm NAILS SKEWED THROUGH STUD INTO PLATE.
1/M12 CHEMICAL ANCHOR FIXED WITH
BOTTOM PLATES TO SLAB 9.11 3.7 TABLE 9.20 d 12 RAMSET CHEMSET REO 502 (OR EQUIVALENT)
EMBEDDED 70mm @1200CRS. NOGGINS TO STUDS 2/75mm x 3.05mm NAILS SKEWED OR THROUGH NAILED.
TIMBER BRACES TO STUDS OR
2/50 x 2.8mm ∅ NAILS AT EACH JOINT.
PLATES
PLATES UP TO 38mm THICK - 2/75mm x 3.05mm NAILS AT MAX. 600mm CTS
BOTTOM PLATES TO JOISTS
PLATES UP TO 38 TO 50mm THICK - 2/90mm x 3.05mm NAILS AT MAX. 600mm CTS
ONE 75mm MASONRY NAIL (HAND DRIVEN AT SLAB EDGE),
BOTTOM PLATES TO CONCRETE SLAB
NOTE: SCREW OR BOLT AT NOT MORE THAN 1200mm CRTS.
1. TIE DOWN MEMBERS NOT IN THIS TABLE REFER TO NOMINAL FIXINGS TABLES MULTIPLE STUDS 1/75mm x 3.05mm NAIL AT 600mm CTS. MAX.
2. TIE DOWN SPECIFIED IN THE TABLE ABOVE CAN BE SUBSTITUTED PROVIDING STILL MEETS REQUIRED UPLIFT FORCE
3. MIN. RAMSET CHEMSET REO 502 (OR EQUIVALENT) TO BE USED REFER MANUFACTURERS DETAILS FOR FIXINGS. POSTS TO BEARERS OR JOISTS 1/M12 OR 2/M10 BOLTS (UNLESS OTHERWISE SPECIFIED).

TIMBER NOTES: ROOF FRAMING


T1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720, AS 1684. ROOF TRUSSES TO TOP PLATES &
T2. ALL TIMBER CONNECTIONS TO BE IN ACCORDANCE WITH AS 1684, UNLESS NOTED OTHERWISE ALL PROPRIETARY REFER TO TABLE 9.4a.
BATTENS TO ROOF TRUSSES
CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS DETAILS.
T3. WALL FRAMING HAS BEEN DESIGNED FOR THE ROOF TRUSS LAYOUT SHOWN. AN ALTERNATIVE RAFTER TO TOP PLATE - COUPLED
REFER TO TABLE 9.4a.
TRUSS LAYOUT WILL REQUIRE REDESIGN AT THE BUILDERS EXPENSE. ROOFS
T4. LINTELS HAVE BEEN DESIGNED SO THAT LONG TERM DEFLECTION SHALL BE LESS THAN EITHER SPAN / 360 OR 9mm. RAFTER TO TOP PLATE - NON
2/75mm SKEW NAILS.
T5. ALL TIMBER TO BE MIN. JOINT GROUP JD4. COUPLED
T6. TRIM OPENINGS IN CEILINGS AND ROOFS FOR SKYLIGHTS, EXHAUST DUCT, FLUES AND SIMILAR.
PROVIDE SUITABLE NOGGING AND UPSTANDS AS REQUIRED. CEILING JOISTS TO TOP PLATES 2/75mm SKEW NAILS.
T7. FOR TERMITE RESISTANCE IN TIMBER FRAMING IT IS RECOMMENDED THE USE OF CYPRESS OR ANY IN COUPLED ROOF CONSTRUCTION. 1/75mm HAND DRIVEN NAIL, OR
OTHER NATURAL TERMITE RESISTANT TIMBER LISTED IN AS 3660 PART 1, 1995, APPENDIX. A5. CEILING JOISTS TO RAFTERS
2/75mm x 3.05mm MACHINE DRIVEN NAILS.
T8. BLOCKING AT MAX. 1800 C/C AND OVER SUPPORTS, FIXED AS PER MANUFACTURERS SPECIFICATIONS.
T9. HANGING BEAMS TO ROOF TO BE IN ACCORDANCE WITH TRUSS DESIGN & SPECIFICATION. COLLAR TIES TO RAFTERS 1/M10 BOLT FOR TIES OVER 4.2m, OR 3/75mm NAILS UP TO 4.2mLONG.
T10. BINDER TO BE IN ACCORDANCE WITH TRUSS MANUFACTURERS DESIGN & SPECIFICATION AND AT MAX. 3000mm CRS.
T11. BATTENS -25x50mm (TILE) OR 38x70mm (SHEET) HWD F14 (J2) ROOF BATTENS AT 330mm c/c (TILE) OR 900 c/c (SHEET). VERANDAH/ROOF BEAMS TO POST 1/M12, OR 2/M10 BOLTS (UNLESS OTHERWISE SPECIFIED FOR TIE - DOWN).
FIXED TO TRUSS OR RAFTERS WITH NAIL OR SCREW AS PER TIE DOWN TABLE.
T12. BOTTOM CHORD BRACING WHICH IS STRUCTURALLY ADEQUATE TO TRANSFER THE WIND LOADS FROM THE
ROOF TRUSSESTO THE NOMINATED BRACING WALL IS TO BE INSTALLED.

APPROVED CLIENT SHEET PROJECT ADDRESS REVISION PROJECT NO.


GERVASE PURICH TORO HOMES WIND BRACING NOTES LOT 55, NO.4 MELALEUCA WAY, 0 3.22.4970.2
CIVIL ENGINEER
FIEAust. CPEng, NER, BPB, RBP, RPEQ No. 11656 CHRISTY'S CREEK, CESSNOCK. NSW. DATE SHEET NO.
CLIENT REFERENCE. No. TH10210 SCALE - N/A TEL (02) 9475 3000 FAX (02) 9646 2311 EMAIL: [email protected]
30/01/2023 S-402

You might also like