(IS) conditioner for (IS) RVDT sensor
690210266 (IS)
Utilization range

 Electrical :
Power supply: 15VDC to
28VDC
 Storage temperature: -65°C/
+150°C
 Operating temperature: -40°C
/ +85°C

Contact

Meggitt (Sensorex)
(IS) 690210266 signal conditioner features 6 wires inductive RVDT sensor signal treatment in
Archamps Technopôle
explosive atmosphere. This conditioner delivers a 4 /20mA current output proportional to the
196 Rue Louis Rustin
sensor core rod displacement. It has two screw terminals for sensor broken wire detection
74166 ARCHAMPS- France
or power supply failure.
Tel: 04 50 95 43 70
Fax: 04 50 95 43 75
www.sensorex.fr
www.meggitt.com

Meggitt Sensing Systems


Our measurement product competencies:
LVDTs | Inertial systems | Inclinometers | Accelerometers | IMU |
MEMS sensors | Servo-inclinometer | Conditioners
Aerospace
Energy
Measurement
Railway

Sensorex®
(IS) conditioner for (IS) RVDT sensor
690210266 (IS)
Mechanical and environmental characteristics Contact
Number of channel 1
Meggitt (Sensorex)
Location unit Hazardous area
Archamps Technopôle
Dimensions 215*121*55 (mm) 196 Rue Louis Rustin
Box material Aluminum(*) 74166 ARCHAMPS- France

Junction Screw terminals Tel: 04 50 95 43 70


Fax: 04 50 95 43 75
Protection IP 40 www.sensorex.fr
Vibrations 2g (white noise) www.meggitt.com

Weight Nearly 950 g

(*)Use in zone 0: the conditioner external housing includes aluminum; it shall be protected against any
impact or friction.

Mechanical characteristics at +25°C


Power supply 15VDC to 28VDC

Maximum consumption 60mA

Sensor supply voltage 2.2 Veff ±20%

Sensor frequency 3500 Hz ±10%

Synchronized demodulation on secondaries sum

Filter 450 Hz ±20%

Output signal 4/20mAdc

Load resistance 280 Ω for 15Vdc to 730 Ω for 28Vdc

Maximum non linearity ±0.1% FS

Maximum accuracy error ±0.2% FS

Zero thermal drift ±25 ppm/°C/FS

Sensitivity thermal drift 150 ppm/°C

Note: the terminal blocks must be associated to intrinsically safe devices and these combinations must be
compatible as regards intrinsic safety rules.

Selection guide
Designation Product reference Marking details

(IS) conditioner for (IS) RVDT 690210266 Ex ia IIC T5 or Ex ia IIB T4


Ex ia IIC T4
Ex ia IIC T3 or Ex ia IIB T3
The temperature classification depending on Ta ambient temperature is:
- T5 in IIC atmosphere for Ta less than 40°C
- T4 in IIB atmosphere for Ta less than 40°C
- T4 in IIC atmosphere for Ta less than 75°C
- T3 in IIC atmosphere for Ta less than 85°C - T3 in IIB atmosphere for Ta less than 85°C

Meggitt Sensing Systems


Our measurement product competencies: