Tangential Storage Silos and Cement Conveying Equipment: Operating Manual en-D000091-5K-6C-A
Tangential Storage Silos and Cement Conveying Equipment: Operating Manual en-D000091-5K-6C-A
en-D000091-5K-6C-A
Code word
SAMANFA
Order no.
D000091
Contents
en-D000091-5K-6C-A
Technical Data Operating manual
1-2 Tangential storage silos and cement conveying equipment
1 Technical Data
NOTE
Refer to the machine manuals or operating instructions of the respective
machines for the technical data of the individual machines. The machines are
listed with their item designations at the end of this section. For the
documentation for an individual machine, refer to the Table of contents in the
first folder of the overall documentation. The table of contents lists the machines
and units in accordance with their positioning in the plant. However, the table of
contents does not include all sub-items that are in the flowsheets. Refer to the
respective main items for information on the sub-items.
Consult the technical documentation of the respective manufacturer or supplier
for the technical data of machines not supplied by POLYSIUS AG Beckum.
Instructions for the control of the plant are included in the process functional
diagrams of POLYSIUS AG and in the documentation of the control system.
en-D000091-5K-6C-A
Operating manual Technical Data
Tangential storage silos and cement conveying equipment 1-3
Silo
Material..........................................................................................................cement
Bulk density (determined in accordance with EN 459-2) ............................ 1.2 t/m3
Storage density in the silo ......................................................................... 1.35 t/m3
Material temperature ................................................................................... ≤ 90 °C
Inside diameter................................................................................................. 16 m
Silo height......................................................................................................... 50 m
Useful capacity ........................................................................................... 12,000 t
Number of the inlets ............................................................................................... 1
Number of the outlets ........................................................................................... 10
Air requirement...................................................................................... 10.9 m3/min
Blower-overpressure ..................................................................................... 0.6 bar
Central chamber
Diameter.......................................................................................................... 3.0 m
Volume ............................................................................................................ 15 m3
Number of the inlets ............................................................................................. 10
Number of the outlets ............................................................................................. 3
Air requirement........................................................................................ 5.1 m3/min
Blower-overpressure ..................................................................................... 0.6 bar
Conveyance
Quantity .................................................................................................................. 1
Type..............................................................................................................ROOTS
Intake capacity ...................................................................................... 11.2 m3/min
Quantity .................................................................................................................. 1
Type..............................................................................................................ROOTS
Intake capacity .................................................................................. ca. 5.1 m3/min
en-D000091-5K-6C-A
Technical Data Operating manual
1-4 Tangential storage silos and cement conveying equipment
Two of the four silos each use a joint silo dedusting system (BF01). This
document describes a block of two silos. The other block is identical and is not
described here.
POLYSIUS Customer's
Designation Order Code Code 1
Cement storage 5K
Bag filter 5K1.BF01 170 06
Bag filter 5K1.BF02 170 16
Compressed air piping 5K1.PP01 170 12
Rotary blower 5K1.RB01 170 12
Rotary blower 5K1.RB02 170 13
Tangential storage silo 5K1.SL01 170 11
en-D000091-5K-6C-A
Operating manual Technical Data
Tangential storage silos and cement conveying equipment 1-5
POLYSIUS Customer's
Designation Order Code Code 1
Discharge from silo/conveying
packing plant/loading 6C1 160 03
Outlet apparatus 6C1.DD01 170 14
Outlet apparatus 6C1.DD02 170 21
Outlet apparatus 6C1.DD03 170 21
Loading devices 6C1.LD01 170 15
Pneumatic trough conveyor 6C1.TC01 170 22
Discharge from silo/conveying
packing plant/loading 6C2 160 03
Outlet apparatus 6C2.DD01 170 14
Outlet apparatus 6C2.DD02 170 21
Outlet apparatus 6C2.DD03 170 21
Loading devices 6C2.LD01 170 15
Pneumatic trough conveyor 6C2.TC01 170 22
en-D000091-5K-6C-A
Operating manual Safety
Tangential storage silos and cement conveying equipment 2-1
2 Safety
NOTE
Be sure to comply with the general safety instructions in the supplement
Important notes on the documentation.
Use
• The plant is exclusively intended for the storage, conveyance and transport of
bulk materials, ranging from dry pulverised materials up to fine-grained and
fluidisable materials.
Be sure to comply with the specifications of the maximum permissible
temperature and the permissible moisture content indicated in the section
Technical Data.
• Any use other than the intended use (e.g. storage of flammable or explosive
bulk materials) is forbidden. POLYSIUS AG is not responsible for damage
resulting from any use other than the intended use. All other use is at the
owner's own risk.
• The intended use also includes compliance with the instructions in the
operating manual, the machine manuals, and the operating instructions.
Operation
• Any safety checks before or during operation depend on the relevant national
regulations. The plant management is responsible for the performance and
recording of such checks.
• If changes in the plant or its operating behaviour relevant to safety occur, shut
the plant down immediately.
• All silo doors and access openings must be closed and secured with padlocks.
Inspection
• Be sure to comply with all warning signs and safety instructions on the
machines as well as in the machine manuals and operating instructions.
• Make absolutely sure that all machines and motors whose operation might
endanger persons or equipment are switched off and safeguarded against
restarting for the entire duration of the inspection work.
• Make absolutely sure that all rotating parts of the machines have come to a
complete standstill before you remove any protection devices or open any
covers.
• Before starting work on the machines, make absolutely sure that there is no
danger of suffering burns when touching the machines. Before opening any
inspection and service covers, make absolutely sure that there is no longer
any hot material inside the machines.
• Remount all protection devices and properly close all inspection and service
covers after the inspection work has been finished.
en-D000091-5K-6C-A
Operating manual Components and mode of functioning
Tangential storage silos and cement conveying equipment 3-1
Figure 3
1 Silo feeding system 6 Rotary blower for aerating the central chamber
2 Main silo compartment 8 Outlet apparatus for bulk loading
3 Central chamber 9 Outlet apparatuses for packing plants 1 and 2
Rotary blower for silo
4
aeration
en-D000091-5K-6C-A
Components and mode of functioning Operating manual
3-2 Tangential storage silos and cement conveying equipment
en-D000091-5K-6C-A
Operating manual Components and mode of functioning
Tangential storage silos and cement conveying equipment 3-3
2 Outlet apparatuses
2.2 Sector valve
2.3 Trough conveyor section (FLUIDOR ® pneumatic trough conveyor )
2.7 Shut-off flap (silo venting)
3 Central chamber
3.2 Aeration floor
3.4 Aeration nozzles in cone of central chamber
3.9 Filling level limit switch
3.10 Access hatch
en-D000091-5K-6C-A
Components and mode of functioning Operating manual
3-4 Tangential storage silos and cement conveying equipment
Figure 5
en-D000091-5K-6C-A
Operating manual Components and mode of functioning
Tangential storage silos and cement conveying equipment 3-5
Figure 6
Ventilation system
The tangential silo and the central chamber must be vented via filter installations.
To prevent heat accumulations, the venting system of the silo cone is located in
the room below the silo cone.
en-D000091-5K-6C-A
Components and mode of functioning Operating manual
3-6 Tangential storage silos and cement conveying equipment
Tangential silo
The tangential silo is used for interim storage of dry, fluidisable bulk materials. It
is continuously fed through the silo inlet. The maximum filling level is set by
means of the filling level limit switch.
The current filling level in the tangential silo can be determined by filling level
measurement (continuously, in case of radar measuring, or if the filling system is
shut down, by means of the silo pilot).
Air is blown through the stored bulk material via aeration boxes, fluidising the bulk
material and making it free-flowing. Due to the slanting floor surface, the fluidised
bulk material flows via the silo outlet frames into the downstream outlet
apparatuses.
The aeration boxes and the silo outlet troughs in the tangential silo are supplied
with air from the blower via piping. The air flow rate can be adjusted by manual
valves.
The aeration system of each aeration sector can be turned on and off by shut-off
devices.
10 outlets are arranged beneath the main silo compartment. Each outlet is
equipped with an outlet apparatus. The outlet apparatus consists of a manual
gate valve, a pneumatically controllable rotary flow-regulating valve and a
FLUIDOR® pneumatic trough conveyor arranged downstream of it.
Central chamber
The bulk material is continuously fed into the central chamber via the outlet
apparatuses.
The filling level in the central chamber is kept constant via continuous filling level
measurement and the corresponding control loop for controlling the outlet
apparatuses downstream of the main silo compartment. Overfilling is prevented
by means of a filling level limit switch.
The bulk material is aerated through the aeration floor and thus becomes free-
flowing. It can be discharged via the aerated discharge troughs and the outlet
apparatuses.
The aeration floor and the downstream outlet apparatuses are supplied with
fluidisation air from a blower.
Cement is discharged from the central chamber via three outlet apparatuses: The
outlet apparatuses 5K1.DD02 and DD03 convey material to the pneumatic trough
conveyors 6C1.TC01 and 6C2.TC01 of the packing plants 1 and 2, DD01 is used
for truck loading.
en-D000091-5K-6C-A
Operating manual Components and mode of functioning
Tangential storage silos and cement conveying equipment 3-7
Filling
The tangential storage silo is used for interim storage of dry, fluidisable bulk
materials. The material to be stored is fed in via the upper inlet openings (1.5).
The maximum filling height is limited by the filling level limit switch (1.8).
The respective filling levels in the tangential storage silo can be additionally
determined by the silo pilot (1.7) or continuously by radar measurement.
Emptying
This tangential storage silo is emptied via the aerated silo outlet openings (1.11).
Air is blown through the stored bulk material via the aeration boxes (1.13),
fluidising the bulk material and making it free-flowing. Due to the slanting floor
surface the fluidised bulk material flows via the silo outlet openings (1.11) into the
downstream outlet apparatuses (2).
The bulk material is fed into the central chamber (3) via the outlet apparatuses.
The filling level limit switches (3.9) are used to monitor the filling level in the
central chamber.
en-D000091-5K-6C-A
Components and mode of functioning Operating manual
3-8 Tangential storage silos and cement conveying equipment
en-D000091-5K-6C-A
Operating manual Components and mode of functioning
Tangential storage silos and cement conveying equipment 3-9
en-D000091-5K-6C-A
Operating manual Commissioning
Tangential storage silos and cement conveying equipment 4-1
4 Commissioning
NOTE
Be sure to also perform the checks specified in the machine manuals of
POLYSIUS AG and in the operating instructions of the respective
manufacturers.
Perform a test run of all machines belonging to this functional group or the
subsequent functional group.
Adjust all machines of the functional group in accordance with the
specifications contained in the machine manuals.
en-D000091-5K-6C-A
Commissioning Operating manual
4-2 Tangential storage silos and cement conveying equipment
en-D000091-5K-6C-A
Operating manual Starting the plant
Tangential storage silos and cement conveying equipment 5-1
5.2. Startup
The operating mode used to discharge material from the silo to the packing plant
is basically the same as that used for loading the trucks. It is possible to
simultaneously keep several outlets in operation. When doing this, be sure to
observe the interconnection of the two operating modes.
If the discharge from the silo to an installation has been started, it is not
necessary to start up the silo again for discharge to another installation.
en-D000091-5K-6C-A
Starting the plant Operating manual
5-2 Tangential storage silos and cement conveying equipment
en-D000091-5K-6C-A
Operating manual Shutting down the plant
Tangential storage silos and cement conveying equipment 6-1
The aeration and venting system of the silo cone should remain in operation in
order to maintain a constant temperature under the cone.
Interruption of operation
• If malfunctions of the sensor system or the conveyors occur, the silo should be
shut down as described above.
• In the event of a power failure, all rotary flow-regulating valves of the silo
(main silo compartment and central chamber) must unconditionally be closed.
The valve position for the "Close" procedure must be open when de-
energised, also in the case of a power failure.
en-D000091-5K-6C-A
Operating manual Operation
Tangential storage silos and cement conveying equipment 7-1
7 Operation
7.1. Aerating/emptying the central chamber
WARNING
The silo has to be run until empty at least once a year in order
to prevent damage to the silo and maintain the silo's ability to
function properly.
This applies to the large main silo compartment and also to the downstream
central chamber.
After having been emptied, the silo floor and the aeration boxes in the main
silo compartment have to be inspected and checked for damage and irregu-
larities.
This work has to be properly recorded.
en-D000091-5K-6C-A
Operation Operating manual
7-2 Tangential storage silos and cement conveying equipment
en-D000091-5K-6C-A
Operating manual Trouble shooting
Tangential storage silos and cement conveying equipment 8-1
8 Trouble shooting
Provided that maintenance work is properly carried out and that the plant is
correctly operated, faults should not occur. However, if operating trouble does
occur, its cause must be determined and eliminated immediately.
NOTE
For trouble shooting at the individual machines and units, consult the machine
manuals or operating instructions of the respective machines. The trouble
shooting instructions below refer to faults that affect the entire installation
described in this operating manual.
en-D000091-5K-6C-A
Operating manual Appendix
Tangential storage silos and cement conveying equipment 9-1
9 Appendix
Flowsheet 65000414,
pages 5K1 - 6C3
en-D000091-5K-6C-A