COMPANY Container Site Office
COMPANY Container Site Office
1 Container Size And Condition 1 unit 40 feet Container min 90 % Container in good condition (L1200mm x W2438mm x H2800mm).
2 Exterior 1 Unit Container Steel Walls
3 Interior Wall and Ciling 1 unit Melamine wood with Alumunium List
4 Frame 1 Unit Wood/ Steel Hollow
5 Insulation 1 Unit Glass wool 5 cm
6 Floor 1 Unit Vinyl Sheet
Door, dor handle and Lock. 970mm x 2080mm external entry door, constructed from Steel Sheeting complete with handle and
7 2 Unit
lock.
Window 965m x 1230 mm sliding windows, constructed from Aluminum Alloy frame and 5mm glass pane (with
8 Unit
3 security bars)
9 Air Conditioner 2 Unit 1 PK air conditioner, split standard type, Sharp brand or equivalent
10 Exhaust Fan 2 Unit 8-10inch exhaust fan, Maspion brand or equivalent.
11 Electrical System 4 unit 36 watt duble fluorescence lights (outbow), SNI local standard.
12 4 point Single power points (positioned as per drawing), SNI local standard.
13 1 Point single power point for exhaust fan (positioned as per drawing), SNI local standard.
14 4 Point Single switches (positioned as per electrical installation drawing), SNI local standard.
15 2 Point 3 Pin single power point for air conditioner (positioned as per drawing), SNI local Standard
MCB box fitted with trip switches and ELCB: lights 6Amp – power points 20Amp – air conditioner
16 1 unit 16Amp – ELCB 25Amp, SNI local standard.
16 Amp, externally mounted, 3 Pin, main power ‘IN’ socket (male and female socketsprovided), SNI
17 Unit
1 local standard.
18 1 unit All internal electrical wiring/cabling will be through wall mounted PVC ducting (outbow) andusing
19 Canopy for all Window and Door 1 Lot steel canopy
20 Painting 1 Lot Exterior paint White Color with JGC Logo
1 Container Size And Condition 1 unit 20 feet Container min 90 % Container in good condition (L6000mm x W2438mm x H2800mm).
2 Exterior 1 Unit Container Steel Walls
3 Interior Wall and Ciling 1 unit Melamine wood with Alumunium List
4 Frame 1 Unit Wood/ Steel Hollow
5 Insulation 1 Unit Glass wool 5 cm
6 Floor 1 Unit Vinyl Sheet
Door, dor handle and Lock. 970mm x 2080mm external entry door, constructed from Steel Sheeting complete with handle and
7 1 Unit
lock.
Window 965m x 1230 mm sliding windows, constructed from Aluminum Alloy frame and 5mm glass pane (with
8 Unit
2 security bars)
9 Air Conditioner 1 Unit 1 PK air conditioner, split standard type, Sharp brand or equivalent
10 Exhaust Fan 1 Unit 8-10inch exhaust fan, Maspion brand or equivalent.
11 Electrical System 2 unit 36 watt duble fluorescence lights (outbow), SNI local standard.
12 2 point Single power points (positioned as per drawing), SNI local standard.
13 1 Point single power point for exhaust fan (positioned as per drawing), SNI local standard.
14 2 Point Single switches (positioned as per electrical installation drawing), SNI local standard.
15 1 Point 3 Pin single power point for air conditioner (positioned as per drawing), SNI local Standard
16 1 unit MCB box fitted with trip switches and ELCB: lights 6Amp – power points 20Amp – air conditioner
17 1 Unit 16 Amp, externally mounted, 3 Pin, main power ‘IN’ socket (male and female socketsprovided), SNI
18 1 unit All internal electrical wiring/cabling will be through wall mounted PVC ducting (outbow) andusing
19 Canopy for all Window and Door 1 Lot Steel canopy
20 Painting 1 Lot Exterior paint White Color with JGC Logo
1 Container Size And Condition 1 unit 20 feet Container min 90 % Container in good condition (L6000mm x W2438mm x H2800mm).
2 Exterior 1 Unit Container Steel Walls
3 Interior Wall and Ciling 1 unit Melamine wood with Alumunium
4 Frame 1 Unit Wood/ Steel Hollow
5 Insulation 1 Unit Glass wool 5 cm
6 Floor 1 Unit Original Container Floor
7 Door, dor handle and Lock. 1 Unit 970mm x 2080mm external entry door, constructed from Steel Sheeting complete with handle and
lock.
8 Window 2 Unit 965m x 1230 mm sliding windows, constructed from Aluminum Alloy frame and 5mm glass pane (with
9 Air Conditioner 1 Unit 1 PK air conditioner, split standard type, Sharp brand or equivalent
10 Exhaust Fan 1 Unit 8-10inch exhaust fan, Maspion brand or equivalent.
11 Electrical System 2 unit 36 watt duble fluorescence lights (outbow), SNI local standard.
12 2 point Single power points (positioned as per drawing), SNI local standard.
13 1 Point single power point for exhaust fan (positioned as per drawing), SNI local standard.
14 2 Point Single switches (positioned as per electrical installation drawing), SNI local standard.
15 1 Point 3 Pin single power point for air conditioner (positioned as per drawing), SNI local Standard
16 1 unit MCB box fitted with trip switches and ELCB: lights 6Amp – power points 20Amp – air conditioner
17 1 Unit 16 Amp, externally mounted, 3 Pin, main power ‘IN’ socket (male and female socketsprovided), SNI
18 1 unit All internal electrical wiring/cabling will be through wall mounted PVC ducting (outbow) andusing
19 Canopy for all Window and Door 1 Lot Steel canopy
20 Painting 1 Lot Exterior paint White Color with JGC Logo
1 Container Size And Condition 1 unit 20 feet Container min 90 % Container in good condition (L6000mm x W2438mm x H2800mm).
2 Exterior 1 Unit Container Steel Walls
3 Interior Wall and Ciling 1 unit (corrugated iron zincalume).
4 Frame 1 Unit Steel Hollow
5 Insulation 1 Unit N/A
6 Floor 1 Unit Alumunium / (Corrugated iron Zincalume) Checkered plate
7 Door, dor handle and Lock. 5 Unit 970mm x 2080mm external entry door, constructed from Steel Sheeting complete with handle and
8 Window N/A
9 Air Conditioner N/A
10 Exhaust Fan 5 Unit 8-10 inch exhaust fan, Maspion brand or equivalent.
11 Electrical System 5 unit 8-12 watt Bulb Lamp, SNI local standard.
12 N/A
13 5 Point single power point for exhaust fan (positioned as per drawing), SNI local standard.
14 5 Point Single switches (positioned as per electrical installation drawing), SNI local standard.
15 N/A
16 1 unit MCB box fitted with trip switches and ELCB: lights 16Amp – power points 20Amp ELCB 25Amp, SNI
17 1 Unit 16 Amp, externally mounted, 3 Pin, main power ‘IN’ socket (male and female socketsprovided), SNI
18 1 unit All internal electrical wiring/cabling will be through wall mounted PVC ducting (outbow) andusing
19 5 unit Water Closet ( ammerican statndard or equivalent)
Sanitary Sytem
20 5 unit Jet Washer
21 5 unit Faucet
22 5 unit Coat Hooks
23 Canopy for all Window and Door 1 Lot Steel canopy
24 Painting 1 Lot Exterior paint White Color with JGC Logo