LB 4811

The K-3980 Battery Load Bank is a device for testing batteries with voltages of 48V and 110V and currents up to 100A. It can discharge batteries to test their capacity and monitor their performance. Optional data loggers wirelessly monitor and record the voltage of each cell during discharge. The load bank has customizable models and safety features to protect batteries from damage during testing.

Uploaded by

Khachung Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views2 pages

LB 4811

The K-3980 Battery Load Bank is a device for testing batteries with voltages of 48V and 110V and currents up to 100A. It can discharge batteries to test their capacity and monitor their performance. Optional data loggers wirelessly monitor and record the voltage of each cell during discharge. The load bank has customizable models and safety features to protect batteries from damage during testing.

Uploaded by

Khachung Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

K-3980 Battery Load Bank

K-3980 Battery Load Bank


Model No.: LB-4811 (48V/110V 100A)
Typical application: Telecom & Power Utility
LB-4811 DC load unit is specially designed for discharge experiment, battery capacity
test, battery maintenance, engineering examination and other tests for DC power with
load. It is specifically designed for nominal voltage of 48V and 110V battery system
with max discharge current of 100A. This makes it applicable for battery discharge in
the areas of telecom and power substation.
With its optional Data Acquisition Case (DAC), you will have a real-time monitoring for
the whole process of discharge with wireless communication in PC.

Our Advantages
1) K-3980 has different customized models to meet requirement of customers from
various industries exactly.
2) Its optional data loggers enables a wireless communication with computer. And it
will monitor the whole process of discharge including voltage of EACH cell.
3) Standard discharge function and other functions like assistant discharge, parallel
load, external load, charge monitor. Compatible with non-Kongter load banks.
4) Rugged, reliable and durable with very good price.

Features
 Optional wireless DAC enables real-time PC monitor during measurement
 It sets 4 conditions for discharge auto shut-down:
Discharge time, discharge capacity, string voltage and cell voltage
 Continued discharge available when previous discharge is stop abnormally
 Parallel connection of two units for higher discharge current
Optional DAC
 Assistant discharge to add load to even non-Kongter load banks
 Can monitor measurement of other load banks or battery charger
 Accurate data measurement and vivid waveforms of PC software
 Auto sorting for lag-out batteries during discharge
 Safe circuits avoids damage to battery during measurement
 Powerful management software for data analysis and report generation
 Automatic protection upon over-heating and overload

Optional Data Acquisition Case (DAC)


Each DAC is recording voltage of up to 12 cells. It has wireless communication with
Connection with 1.2V or 2V cells:
K-3980 main unit and PC. And it is capable to measure all type of batteries (1.2V, 2V,
6V & 12V). Kongter also offers customized DAC for other battery types.
DAC numbers are easily expandable to cover more battery volumes.

Its Connection:
One DAC is connected with 12 cells of 1.2V, 2V or 4 cells of 12V (or 6V). Therefore, in
Connection with 6V or 12V cells:
different battery systems, they require different amount of DACs. With DAC, K-3980
and Kongter PC software will be able to monitor and record voltage of each cell
together with other parameter like String Voltage, Current, Discharge Capacity and so
on.
For the model of LB-4811, it will require 5 standard DACs for measurement of 2V, 6V
and 12V cells.
K-3980 Battery Load Bank

Composition: Technical Parameters

Standard parts: Power supply AC 220V/110V, 50/60Hz;


1
 Main unit of load bank 1) Standard: 1.2V , 2V, 6V and 12V

 Carrying case Cell type 2) Customized: 12V ONLY or other uncommon

 Data View software battery types.

 Set of 3m/10ft load cables 10V-55.2V(nominal: 48V)

 3m/10ft voltage test leads 10V-126.5V(nominal: 110V)


Discharge voltage range
 PC communication terminal Constant current of 100A in the range of:

 Ground cable 43.2-55.2V & 99-126.5V

 AC Power cord Single load bank: 10A-100A


Discharge current range
 USB with backup info Parallel load: 10A-200A
 Antenna Current: 1%
Accuracy
Voltage: 0.5% – 0.8%
Optional: Current: 0.1 A or 0.5%
Resolution
 DAC package Voltage: 0.001 V
 Current clamp for external loads Sampling Interval 5s –1min
 Parallel load cable Discharge pattern Constant current
Display 128*64 pixel LCD
Data transfer USB, Radio Frequency (for DAC to load bank)
Operation Temperature 0℃~40℃ (32 – 104 °F)
Humidity 5%~90% Relative humidity
Standard CE marking, EMC standard
Main Unit Dimension 520 x 202 x 355 mm

Main unit Weight 16 kg

*NOTE:
1) Quantity of DAC and cable in standard DAC package are based on 2V, 6V and
12V. For measurement of 1.2V Ni-cd batteries, you will require some more DACs
and relevant cables.

Kongter PC Software
All standard load units of K-3980 come with PC software. With the software, you have
a real-time data monitoring, analyze the testing data and easily print out the complete
report.
K-3980 PC Software

Kongter Test & Measurement Co., Limited


#405, Bldg 62, Songpingshan, Langshan Rd., Shenzhen China
TEL: +86-755-2691 6832 Web: www.kongter.com Email: [email protected]