DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

PROJECT ONE – ECR EPCM SERVICES CONTRACT

7650-8550-DS-500-6158

LEVEL INSTRUMENTS DATASHEETS


RADAR LEVEL TRANSMITTER DATASHEETS - AREA OF PAU-004 (P4)

EE1 27-Dec-2022 FE FOR ENQUIRY AS PHC SCA

Rev.No. Date Issue Code Description Prepared by Reviewed by Approved by

© All rights reserved. This document is protected by copyright. The contents and information in this document, in particular text, drawings and images it contains, are
strictly confidential and may not be altered or amended, copied, used or disclosed without the express permission of the rights holder.
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

CLIENT
LOGO Project One – ECR EPCm

PROJECT No.: 10420


PAGE 2 of 105

INDEX

ITEM TAG NUMBER REVISION STATUS PAGE


1 ECR-LT -30103A EE1 RFI 4
2 ECR-LT -30103B EE1 RFI 6
3 ECR-LT -30201A EE1 RFI 8
4 ECR-LT -30201B EE1 RFI 10
5 ECR-LT -30210 EE1 RFI 12
6 ECR-LT -30312 EE1 RFI 14
7 ECR-LT -30401A EE1 RFI 16
8 ECR-LT -30401B EE1 RFI 18
9 ECR-LT -30401C EE1 RFI 20
10 ECR-LT -34129 EE1 RFI 22
11 ECR-LT -34259 EE1 RFI 24
12 ECR-LT -35109A EE1 RFI 26
13 ECR-LT -35109B EE1 RFI 28
14 ECR-LT -35202A EE1 RFI 30
15 ECR-LT -35202B EE1 RFI 32
16 ECR-LT -35213 EE1 RFI 34
17 ECR-LT -36102A EE1 RFI 36
18 ECR-LT -36102B EE1 RFI 38
19 ECR-LT -36103A EE1 RFI 40
20 ECR-LT -36103B EE1 RFI 42
21 ECR-LT -89501A EE1 RFI 44
22 ECR-LT -91103 EE1 RFI 46
23 ECR-LT -91316 EE1 RFI 48
24 ECR-LT -91317 EE1 RFI 50
25 ECR-LT -91368 EE1 RFI 52
26 ECR-LT -91402 EE1 RFI 54
27 ECR-LT -92466 EE1 RFI 56
28 ECR-LT -92566 EE1 RFI 58
29 ECR-LZT -30191A EE1 RFI 60
30 ECR-LZT -30191B EE1 RFI 62
31 ECR-LZT -30191C EE1 RFI 64
32 ECR-LZT -30192A EE1 RFI 66
33 ECR-LZT -30192B EE1 RFI 68
34 ECR-LZT -30192C EE1 RFI 70
35 ECR-LZT -30202A EE1 RFI 72
36 ECR-LZT -30202B EE1 RFI 74
37 ECR-LZT -30202C EE1 RFI 76
38 ECR-LZT -30302A EE1 RFI 78
39 ECR-LZT -30302B EE1 RFI 80
40 ECR-LZT -30302C EE1 RFI 82
41 ECR-LZT -30501A EE1 RFI 84
42 ECR-LZT -30501B EE1 RFI 86
43 ECR-LZT -30501C EE1 RFI 88
44 ECR-LZT -35104A EE1 RFI 90
45 ECR-LZT -35104B EE1 RFI 92
46 ECR-LZT -35104C EE1 RFI 94
47 ECR-LZT -35201A EE1 RFI 96
48 ECR-LZT -35201B EE1 RFI 98
49 ECR-LZT -35201C EE1 RFI 100
50 ECR-LZT -91114 EE1 RFI 102
51 ECR-LZT -91311 EE1 RFI 104

98
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
GENERAL NOTES:

1- VTA: Vendor to Advise.


2- Spare Cable entries shall be plugged with brass screw plug. Cable gland entry shall be supplied with plastic plug
3- Positive Material Identification (PMI) shall be done for pressure containing housing as per INEOS specification
4- Transmitter shall have HART Protocol version 7 with sensor fault indication to NAMUR NE 43. Hart tag number shall be configured in
Manufacturing
5- Burn out direction shall be specified in EPC stage based on process requirements.
6- Transmitter self?monitoring and diagnostics shall be in accordance to NAMUR NE 107.
7- Instrument casings, enclosures and housings shall be anodised aluminium and suitably painted for the environmental conditions.
8- Vendor to provide all applicable testing certificates such as Calibration certificate, Hydrotest, Radiography, Dye penetration test , Intergranular
Corrosion test, etc.
9- Values for Dielectric Constant are on HOLD.
10- Centering Ring / Counterweight shall be provided by Vendor.
11- SIL certificates with failure rates as per IEC 61508 ed. 2010 shall be provided.
12- Material Certificate: EN 10204 3.1 for pressure retaining part.
13- Vendor to provide all applicable testing certificate such as Calibration certificate, Hydrotest, Radiography, PMI test, DP test, Intergranular
corrosion test, etc
14- The meter electronics shall be protected against transients induced by lightning and power supply surges. Transient protection electronics shall
preferably be provided in the terminal block. The transient protection shall meet the requirements specified in IEC-60587.

Domain: INEOS_ECR Plant: ECR_P


Area: ECR Unit: 35

Binder Package
General Notes
Template: P4
7650-8550-DS-500-6158, RADAR
EE1 AS 27/12/2022 FOR ENQUIRY LEVEL TRANSMITTER Page N-1 of 1
No. By Date Description Doc. No.: DATASHEETS - ARE Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30103A 61 Plant ECR_P
3 Service D3010 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3010 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 750 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 750 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Condensate 93 NACE Requirements N/A
35 Upper Fluid Name Condensate 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 980 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-1.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30103A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30103A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210°C/ FV @125 °C.
3. Electrical Tracing Temperature: 5 ° C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-1.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30103A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30103B 61 Plant ECR_P
3 Service D3010 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3010 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 750 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 750 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Condensate 93 NACE Requirements N/A
35 Upper Fluid Name Condensate 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 980 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-2.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30103B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30103B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210°C/ FV @125 °C.
3. Electrical Tracing Temperature: 5 ° C

Instruments notes:
I-1. PED Classification: Fluid Group (1)/ PED Category (hold)
I-2. VTA: Vendor to Advise

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-2.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30103B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30201A 61 Plant ECR_P
3 Service D3020 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 720 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 720 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-3.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30201A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30201A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210°C/ FV @125 °C.
3. Electrical Tracing Temperature: 5 ° C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-3.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30201A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30201B 61 Plant ECR_P
3 Service D3020 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 720 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 720 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-4.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30201B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30201B

Process notes:
1. PED classification fluid state/group-G/1
2.Steam Out Conditions: 7 barg @ 210°C/ FV @125 °C.
3. Dryout conditions: 7barg @ 60°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-4.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30201B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30210 61 Plant ECR_P
3 Service E 1035 Propane Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 2050 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2050 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-5.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30210 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30210

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@ 7 barg and 125 deg C @FV
3. Dryout conditions: 7barg @ 60°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-5.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30210 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30312 61 Plant ECR_P
3 Service D3030 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3030 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2009 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 940 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 940 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5,21 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 0 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 11,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-6.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30312 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30312

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210 °C/ FV @ 125 °C.
3. Dryout conditions: 7barg @ 60°C.
3. Electrical Tracing Temperature : 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-6.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30312 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30401A 61 Plant ECR_P
3 Service D3040 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3040 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2011 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 230 - 670 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 670 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons/Water/Hydrogen 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons/Water/Hydrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,87 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 992,4 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-7.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30401A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30401A

Process notes:
1. PED classification fluid state/group-G/1
2. Dry Out Conditions: 7 barg @ 60°C.
3. Steam Out Conditions: 125°C at FV and 210°C at 7.0 Barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-7.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30401A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30401B 61 Plant ECR_P
3 Service D3040 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3040 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2011 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 230 - 670 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 670 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons/Water/Hydrogen 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons/Water/Hydrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,87 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 992,4 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-8.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30401B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30401B

Process notes:
1. PED classification fluid state/group-G/1
2. Dry Out Conditions: 7 barg @ 60°C.
3. Steam Out Conditions: 125°C at FV and 210°C at 7.0 Barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-8.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30401B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -30401C 61 Plant ECR_P
3 Service D3040 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3040 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2011 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 230 - 670 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 670 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons/Water/Hydrogen 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons/Water/Hydrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,87 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 992,4 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-9.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-30401C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -30401C

Process notes:
1. PED classification fluid state/group-G/1
2. Dry Out Conditions: 7 barg @ 60°C.
3. Steam Out Conditions: 125°C at FV and 210°C at 7.0 Barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-9.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-30401C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -34129 61 Plant ECR_P
3 Service T3410 Caustic Wash Twr Lvl 62 Unit 34
4 Equipment ECR-534-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AA 64 Location EQUIP
6 P&ID No. 7650-8110-25-534-2004 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Caustic+Hydrocarbons 90 NACE Requirements N/A
32 Upper Fluid Name Caustic+Hydrocarbons 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 27 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 1016 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower Yes Yes 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-10.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-34129 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -34129

Process notes:
1. PED classification fluid state/group-G/1
2. Considered 70% of the height of the sump for high level alarm

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: STUD: ASTM A193 GR. B7, S2 (IMPACT TESTED) NUT: ASTM A194 GR. 2H, S59 (IMPACT TESTED)
I-3. CHARPY IMPACT TESTED AT -20 DEG.C, MINIMUM 27 JOULES AVERAGE AND 20 JOULES MINIMUM

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-10.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-34129 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -34259 61 Plant ECR_P
3 Service Drain Level 62 Unit 34
4 Equipment ECR-534-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AA 64 Location EQUIP
6 P&ID No. 7650-8110-25-534-2005 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Caustic+Hydrocarbons 90 NACE Requirements N/A
32 Upper Fluid Name Caustic+Hydrocarbons 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Liquid 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 27 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 1016 96 Fire Safe Design N/A
38 Upper Density kg/m³ 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 Upper Specific Gravity 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower Yes Yes 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-11.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-34259 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -34259

Process notes:
1. PED classification fluid state/group-G/1
2. Considered 70% of the height of the sump for high level alarm

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: STUD: ASTM A193 GR. B7, S2 (IMPACT TESTED) NUT: ASTM A194 GR. 2H, S59 (IMPACT TESTED)
I-3. CHARPY IMPACT TESTED AT -20 DEG.C, MINIMUM 27 JOULES AVERAGE AND 20 JOULES MINIMUM

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-11.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-34259 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -35109A 61 Plant ECR_P
3 Service DS3510 Spnt Caus Lvl 62 Unit 35
4 Equipment ECR-DS-3510 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 150 - 1400 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1250 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Spent Caustic 93 NACE Requirements N/A
35 Upper Fluid Name Spent Caustic 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1016 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-12.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-35109A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -35109A

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-12.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-35109A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -35109B 61 Plant ECR_P
3 Service DS3510 Spnt Caus Lvl 62 Unit 35
4 Equipment ECR-DS-3510 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 14000 - 1400 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1250 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Spent Caustic 93 NACE Requirements N/A
35 Upper Fluid Name Spent Caustic 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1016 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-13.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-35109B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -35109B

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-13.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-35109B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -35202A 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 150 - 980 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 830 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 834 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-14.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-35202A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -35202A

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. (Vendor shall offer Probe Material SS316 with optional coating)

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-14.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-35202A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -35202B 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 150 - 980 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 830 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 834 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-15.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-35202B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -35202B

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-15.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-35202B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -35213 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification
5 Piping Class / Trim Spec 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method 68 Type
10 Probe Type 69 Mounting
11 Probe Material 70 Power Supply / From
12 Probe Lining Material 71 Accuracy % Repeatibility
13 Probe Length mm 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection 73 Gas Group Temp Rating
15 Flange Material 74 Certification Zone EEx d
16 Flange Size/Rating/Facing 75 IP Rating
17 Mounting 76 Cable Entries
18 Seal Material 77 Electrical Connections
19 Standard Drawing - Stilling Well 78 Crippled Mode Detection
20 Stilling Well Material 79 Burn-out Direction
21 Stilling Well O.D. mm 80 Calibrated Range -
22 Stilling Well Length mm 81
23 Instrument Range - 82
24 CHAMBER : 83
25 Chamber Material 84
26 Chamber Size / Centre to Centre mm 85
27 Vessel Connection 86
28 Flange Size/Rating/Facing 87
29 Vent / Drain 88
30 Vent / Drain Connection 89
31 Vent/Drain Flange Size/Rating/Facing 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water + Gasoline 93 NACE Requirements
35 Upper Fluid Name Water + Gasoline 94 Certification Authority
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No.
37 Operating Conditions Min Norm Max 96 Material Certificate
38 Pressure barg 5 97 Test Requirements
39 Temperature °C 35,5 98 Special Requirements for Service
40 Lower Density kg/m³ 834 99 Fire Safe Design
41 Upper Density kg/m³ 100 Paint Finish
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg
44 Normal Level mm 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-16.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LDT-35213 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -35213

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-16.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LDT-35213 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -36102A 61 Plant ECR_P
3 Service D3610 Dry Fd Abs Sep Lvl 62 Unit 36
4 Equipment ECR-D-3610 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-536-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 190 - 910 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 720 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,3 97 Test Requirements See Notes
39 Temperature °C 9 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 910 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-17.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-36102A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -36102A

Process notes:
1 . PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter
5. Dry Out conditions: 60°C at 7 barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-17.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-36102A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -36102B 61 Plant ECR_P
3 Service D3610 Dry Fd Abs Sep Lvl 62 Unit 36
4 Equipment ECR-D-3610 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-536-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 190 - 910 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 720 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,3 97 Test Requirements See Notes
39 Temperature °C 9 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 910 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 2,292 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-18.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-36102B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -36102B

Process notes:
1 . PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter
5. Dry Out conditions: 60°C at 7 barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-18.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-36102B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -36103A 61 Plant ECR_P
3 Service D3610 Dry Fd Abs Sep Lvl 62 Unit 36
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-536-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm - 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1500 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name C5 Plus 93 NACE Requirements N/A
35 Upper Fluid Name C5 Plus 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,22 97 Test Requirements See Notes
39 Temperature °C 9 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 993,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18 65 105
47 Dielectric Constant Upper/Lower 1,837 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-19.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-36103A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -36103A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter
5. Dry Out conditions: 60°C at 7 barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-19.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-36103A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -36103B 61 Plant ECR_P
3 Service D3610 Dry Fd Abs Sep Lvl 62 Unit 36
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-536-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 20 - 942 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1500 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name C5 Plus 93 NACE Requirements N/A
35 Upper Fluid Name C5 Plus 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 11,22 97 Test Requirements See Notes
39 Temperature °C 9 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 993,8 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 14,5 104
46 Design Temperature Min/Max °C -18 65 105
47 Dielectric Constant Upper/Lower 1,837 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-20.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-36103B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -36103B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions- 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C
4. GWR Level Transmitter
5. Dry Out conditions: 60°C at 7 barg

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Instrument Range / Calibration Range / : HOLD
I-5. Center to Center : To be review in Tabulation Phase.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-20.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-36103B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -89501A 61 Plant ECR_P
3 Service D8950 Drain Drum Lvl 62 Unit 89
4 Equipment ECR-D-8950 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-589-2010 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 150 - 1350 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1200 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hidrocarbon - Water 93 NACE Requirements N/A
35 Upper Fluid Name Flare Gases Wet 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,3 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 3,5 104
46 Design Temperature Min/Max °C -18,3 210 105
47 Dielectric Constant Upper/Lower 2,274 34,5 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-21.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-89501A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -89501A

PROCESS NOTES:
1. PED classification: Fluid State: G / Group: 1.
2. Steam Out: 3.5 barg @210ºC and FV @125ºC.
3. LT with electrical tracing.
4. High level switch will activate UC-8910 (Start Pump).
5. Low level switch will activate UC-89011 (Stop Pump).
6. Lower Fluid: This instrument can work with a mixture of hydrocarbon / water (Density, 700 /1000 kg/m3), so consider a dielectric constant range
between 1.553 - 34.5 (Hydrocarbon - Water).

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-21.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-89501A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -91103 61 Plant ECR_P
3 Service D9110 Methanol Lvl 62 Unit 91
4 Equipment ECR-D-9110 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 180 - 2420 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2240 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Methanol 93 NACE Requirements N/A
35 Upper Fluid Name Nitrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 1 97 Test Requirements See Notes
39 Temperature °C 27,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 784 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 8 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1 32,63 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-22.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-91103 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -91103

PROCESS NOTES:
1. PED classification: Fluid State: L / Group: 1.
2. Vacuum condition: FV @65 °C.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-22.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-91103 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -91316 61 Plant ECR_P
3 Service D9130 Wash Oil Lvl 62 Unit 91
4 Equipment ECR-D-9130 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 180 - 2420 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2240 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Wash Oil 93 NACE Requirements N/A
35 Upper Fluid Name Nitrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 1 97 Test Requirements See Notes
39 Temperature °C 27,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 985 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 8 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1 2,7 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-23.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-91316 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -91316

PROCESS NOTES:
1. PED classification: Fluid State: L / Group: 1.
2. Steam Out: 7 barg @210ºC and FV @125 °C.
3. Low Low level switch will activate UC-91001.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-23.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-91316 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -91317 61 Plant ECR_P
3 Service Sewer Level 62 Unit 91
4 Equipment ECR-591-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Wash Oil/Methanol/Water 90 NACE Requirements N/A
32 Upper Fluid Name Air 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Gas/Vapor 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 25 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 985 96 Fire Safe Design N/A
38 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-24.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-91317 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -91317

Procces Notes:

1. PED classification: Fluid State: L / Group: 1


2.Lower Fluid: This instrument can work with a mixture of Wash Oil/Methanol/Water (Density, 985 /784/1000 kg/m3).

Instruments Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-24.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-91317 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -91368 61 Plant ECR_P
3 Service Sewer Level 62 Unit 91
4 Equipment ECR-591-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2002 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Wash Oil/Methanol/Water 90 NACE Requirements N/A
32 Upper Fluid Name Air 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Gas/Vapor 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 25 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 985 96 Fire Safe Design N/A
38 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-25.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-91368 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -91368

Procces Notes:

1. PED classification: Fluid State: L / Group: 1


2.Lower Fluid: This instrument can work with a mixture of Wash Oil/Methanol/Water (Density, 985 /784/1000 kg/m3).

Instruments Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-25.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-91368 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -91402 61 Plant ECR_P
3 Service Sewer Level 62 Unit 91
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A0LY 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2007 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting Top Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 1000 82
24 CHAMBER : 83
25 Chamber Material N/A 84
26 Chamber Size / Centre to Centre mm N/A N/A 85
27 Vessel Connection N/A 86
28 Flange Size/Rating/Facing N/A N/A N/A 87
29 Vent / Drain N/A N/A 88
30 Vent / Drain Connection N/A 89
31 Vent/Drain Flange Size/Rating/Facing N/A N/A N/A 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Phosphate/Water 93 NACE Requirements N/A
35 Upper Fluid Name Air 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0 97 Test Requirements See Notes
39 Temperature °C 25 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 985 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 0 104
46 Design Temperature Min/Max °C 65 105
47 Dielectric Constant Upper/Lower 1 78,54 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection EEx d
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C N/A
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-26.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LT-91402 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -91402

PROCESS NOTES:
1. PED Classification fluid stage/group to be confirmed by chemical vendor

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress
I-2. Bolts & Nuts: ASTM A320 Gr. L7 / ASTM A194 Gr. 7, S3

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-26.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LT-91402 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -92466 61 Plant ECR_P
3 Service Sump Level 62 Unit 92
4 Equipment ECR-592-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B0LY 64 Location EQUIP
6 P&ID No. 7650-8110-25-592-2005 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Caustic/Anti Fou./ water 90 NACE Requirements N/A
32 Upper Fluid Name Air 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Gas/Vapor 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 25 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 1330 96 Fire Safe Design N/A
38 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-27.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-92466 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -92466

Procces Notes:

1. PED Classification fluid stage/group to be confirmed by chemical vendor

Instruments Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: STUD: ASTM A320 GR. L7 / NUT: ASTM A194 GR. 7, S3.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-27.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-92466 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LT -92566 61 Plant ECR_P
3 Service Sump Level 62 Unit 92
4 Equipment ECR-592-PIT 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec B0LY 64 Location EQUIP
6 P&ID No. 7650-8110-25-592-2007 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method / Type Time Domain Reflectometry 68 Type LT Non Contact Radar
10 Standard Drawing - Stilling Well N/A 69 Mounting Top Mounted
11 Stilling Well Material N/A 70 Power Supply / From 24VDC Loop Powered
12 Stilling Well O.D. mm N/A 71 Accuracy % Repeatibility ±3mm VTA
13 Stilling Well Length mm N/A 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 4" 300# RF 75 IP Rating IP 66
17 Antenna Type Horn Antenna (VTA) 76 Cable Entries 2
18 Antenna Material SS316 77 Electrical Connections M20 X 1.5
19 Antenna Lining Material VTA 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Antenna Length/O.D./Extension mm VTA VTA VTA 79 Burn-out Direction NA
21 Inactive Length mm VTA 80 Calibrated Range % 0 - 100
22 Insertion Length mm VTA 81
23 Wetted Parts Material SS316 82
24 Instrument Range mm 0 - 1000 83
25 84
26 85
27 86
28 87
29 88
30 PROCESS DATA : 89 SPECIAL REQUIREMENTS :
31 Lower Fluid Name Deeth. Anti Fou./Disp/Water 90 NACE Requirements N/A
32 Upper Fluid Name Air 91 Certification Authority VTA
33 Fluid State Lower / Upper Liquid Gas/Vapor 92 Certification Approval No. VTA
34 Operating Conditions Min Norm Max 93 Material Certificate See Notes
35 Pressure barg 0 94 Test Requirements See Notes
36 Temperature °C 25 95 Special Requirements for Service See Notes
37 Lower Density kg/m³ 910 96 Fire Safe Design N/A
38 97 Paint Finish Mfr. STD
39 Lower Specific Gravity 98 Lightning Protection N/A
40 99 Weight kg VTA
41 Normal Level mm 100
42 Design Pressure Min/Max barg 0 101
43 Design Temperature Min/Max °C 65 102
44 Dielectric Constant Upper/Lower 103
45 Corrosive Agents Upper/Lower No No 104
46 Toxic Agents Upper/Lower No No 105
47 Fluid Type / Service Identification 106 NON-VENDOR RELATED INFO :
48 107 Protection
49 108 Tracing Temperature °C
50 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-28.1 of 102
No. By Chk App Date Revision Spec: 1319 DS No.: 7650-8550-DS-ECR-LT-92566 Rev.: EE1
FW1319.psr Rev 1 Radar Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LT -92566

Procces Notes:

1. PED Classification fluid stage/group to be confirmed by chemical vendor

Instruments Notes:

I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: STUD: ASTM A320 GR. L7 / NUT: ASTM A194 GR. 7, S3.

INSTRUMENT SPECIFICATION

RADAR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-28.2 of 102


No. By Date Revision Code: 1319 Dwg. No.: 7650-8550-DS-ECR-LT-92566 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30191A 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-29.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30191A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30191A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-29.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30191A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30191B 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-30.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30191B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30191B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-30.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30191B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30191C 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,55 97 Test Requirements See Notes
39 Temperature °C 34,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above 103
45 Design Pressure Min/Max barg 3,5 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-31.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30191C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30191C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-31.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30191C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30192A 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 34,3 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 8 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-32.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30192A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30192A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-32.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30192A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30192B 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 34,3 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 8 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-33.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30192B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30192B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-33.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30192B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30192C 61 Plant ECR_P
3 Service Low Pt Drain Boot Proc H2O Lvl 62 Unit 30
4 Equipment - 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2001 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 0 - 1600 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper G Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,5 97 Test Requirements See Notes
39 Temperature °C 34,3 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 8 104
46 Design Temperature Min/Max °C -18,3 185 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-34.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30192C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30192C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-34.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30192C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30202A 61 Plant ECR_P
3 Service D3020 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 350 - 2400 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2050 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-35.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30202A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30202A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@ 7 barg and 125 deg C @FV
3. Dryout conditions: 7barg @ 60°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-35.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30202A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30202B 61 Plant ECR_P
3 Service D3020 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 350 - 2400 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2050 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-36.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30202B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30202B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@ 7 barg and 125 deg C @FV
3. Dryout conditions: 7barg @ 60°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-36.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30202B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30202C 61 Plant ECR_P
3 Service D3020 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3020 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2004 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 350 - 2400 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2050 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 2,04 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1000 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 9 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 75,11 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-37.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30202C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30202C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions 210 deg C@ 7 barg and 125 deg C @FV
3. Dryout conditions: 7barg @ 60°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-37.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30202C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30302A 61 Plant ECR_P
3 Service D3030 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3030 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2009 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 120 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1130 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5,21 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 0 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 11,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-38.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30302A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30302A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210 °C/ FV @ 125 °C.
3. Dryout conditions: 7barg @ 60°C.
4. Electrical Tracing Temperature : 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-38.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30302A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30302B 61 Plant ECR_P
3 Service D3030 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3030 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2009 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 120 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1130 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5,21 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 0 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 11,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-39.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30302B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30302B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210 °C/ FV @ 125 °C.
3. Dryout conditions: 7barg @ 60°C.
4. Electrical Tracing Temperature : 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-39.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30302B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30302C 61 Plant ECR_P
3 Service D3030 CG Cnds Lvl 62 Unit 30
4 Equipment ECR-D-3030 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2009 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 120 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1130 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbon+H2O+H2 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbon+H2O+H2 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5,21 97 Test Requirements See Notes
39 Temperature °C 32,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 0 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg 11,5 104
46 Design Temperature Min/Max °C -18,3 90 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-40.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30302C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30302C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam Out Conditions: 7 barg @ 210 °C/ FV @ 125 °C.
3. Dryout conditions: 7barg @ 60°C.
4. Electrical Tracing Temperature : 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-40.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30302C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30501A 61 Plant ECR_P
3 Service D3050 CG Stage1 Flash Drm Lvl 62 Unit 30
4 Equipment ECR-D-3050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2006 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 160 - 1100 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 940 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 90,7 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 869 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 270 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-41.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30501A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30501A

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions: 3.5 BARG @ 210°C AND FV @ 125°C
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-41.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30501A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30501B 61 Plant ECR_P
3 Service D3050 CG Stage1 Flash Drm Lvl 62 Unit 30
4 Equipment ECR-D-3050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2006 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 160 - 1100 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 940 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 90,7 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 869 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 270 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-42.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30501B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30501B

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions: 3.5 BARG @ 210°C AND FV @ 125°C
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-42.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30501B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -30501C 61 Plant ECR_P
3 Service D3050 CG Stage1 Flash Drm Lvl 62 Unit 30
4 Equipment ECR-D-3050 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-530-2006 65 Design Code
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting TOP mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 160 - 1100 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 940 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Hydrocarbons+Water 93 NACE Requirements N/A
35 Upper Fluid Name Hydrocarbons+Water 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 0,6 97 Test Requirements See Notes
39 Temperature °C 90,7 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 869 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm 103
45 Design Pressure Min/Max barg -1 3,5 104
46 Design Temperature Min/Max °C -18,3 270 105
47 Dielectric Constant Upper/Lower 2,274 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C 5
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.:
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-43.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-30501C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -30501C

Process notes:
1. PED classification fluid state/group-G/1
2. Steam out conditions: 3.5 BARG @ 210°C AND FV @ 125°C
3. Electrical Tracing Temperature: 5°C

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-43.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-30501C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35104A 61 Plant ECR_P
3 Service DS3510 Spnt Caus Lvl 62 Unit 35
4 Equipment ECR-DS-3510 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 120 - 1050
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1250 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Spent Caustic 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1016 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-44.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35104A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35104A

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-44.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35104A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35104B 61 Plant ECR_P
3 Service DS3510 Spnt Caus Lvl 62 Unit 35
4 Equipment ECR-DS-3510 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 120 - 1050
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1250 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Spent Caustic 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1016 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-45.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35104B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35104B

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-45.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35104B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35104C 61 Plant ECR_P
3 Service DS3510 Spnt Caus Lvl 62 Unit 35
4 Equipment ECR-DS-3510 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 120 - 1050
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 1250 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 1250 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Spent Caustic 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 3 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 1016 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 5 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 74,83 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-46.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35104C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35104C

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-46.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35104C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35201A 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 130 - 550
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 830 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 830 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 834 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-47.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35201A Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35201A

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-47.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35201A Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35201B 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 130 - 550
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 830 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 830 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 834 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-48.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35201B Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35201B

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-48.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35201B Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -35201C 61 Plant ECR_P
3 Service DS3520 Caus Wash Gasoline H2O 62
Lvl Unit 35
4 Equipment ECR-DS-3520 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A3AN3 64 Location EQUIP
6 P&ID No. 7650-8110-25-535-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material Monel 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range mm 130 - 550
22 Stilling Well Length mm N/A 81
23 Instrument Range mm 0 - 830 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 830 85
27 Vessel Connection SIDE-SIDE 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Water 93 NACE Requirements N/A
35 Upper Fluid Name GASOLINE 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Liquid 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 5 97 Test Requirements See Notes
39 Temperature °C 35,5 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 834 99 Fire Safe Design N/A
41 Upper Density kg/m³ 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection N/A
43 Upper Specific Gravity 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg 6,7 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1,84 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-49.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-35201C Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -35201C

Process notes:
1. PED classification fluid state/group-L/1
2. Steam out conditions 210 deg C@7 barg & 125 deg C@FV
3. GWR Level Transmitter
4. Caustic Service

Instruments notes:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTM A193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.
I-4. Vendor shall offer Probe Material SS316 with optional coating

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-49.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-35201C Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -91114 61 Plant ECR_P
3 Service D9110 Methanol Lvl 62 Unit 91
4 Equipment ECR-D-9110 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2003 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material PTFE 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 180 - 2420 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2240 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Methanol 93 NACE Requirements N/A
35 Upper Fluid Name Nitrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 1 97 Test Requirements See Notes
39 Temperature °C 27,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 784 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 8 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1 32,63 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-50.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-91114 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -91114

PROCESS NOTES:
1. PED classification: Fluid State: L / Group: 1.
2 Vacuum condition: FV @65 °C
3. High High Level will activated UZ-91004, and closed XZV-91112 in Methanol Storage Drum.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: SS316, Filler: Graphite, Outer Ring: SS316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: ASTMA193 Gr. B7, S2 / ASTM A194 Gr. 2H, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average and 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-50.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-91114 Rev.: EE1
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A
INSTRUMENT SPECIFICATION SHEETS - GUIDED WAVE RADAR LEVEL TRANSMITTERS
Units Units
1 GENERAL : 60 GENERAL :
2 Tag No. ECR-LZT -91311 61 Plant ECR_P
3 Service D9130 Wash Oil Lvl 62 Unit 91
4 Equipment ECR-D-9130 63 Area Classification Zone 1, IIC, T4
5 Piping Class / Trim Spec A1AP3 64 Location EQUIP
6 P&ID No. 7650-8110-25-591-2001 65 Design Code -
7 66
8 PROBE / BODY : 67 TRANSMITTER / ELECTRONICS :
9 Measuring Method Time Domain Reflectometry 68 Type Guided Wave Radar
10 Probe Type Rigid Single Rod 69 Mounting External Chamber Mounted
11 Probe Material SS316/316L 70 Power Supply / From 24VDC Loop Powered
12 Probe Lining Material NA 71 Accuracy % Repeatibility ±3mm VTA
13 Probe Length mm VTA 72 Output Signal Category 4-20mA HART HART Device
14 Process Connection Flanged 73 Gas Group Temp Rating IIC T4
15 Flange Material SS316 74 Certification Zone EEx d ZONE 1
16 Flange Size/Rating/Facing 3" 300# RF 75 IP Rating IP 66
17 Mounting Top Mounted 76 Cable Entries 2
18 Seal Material Ceramic 77 Electrical Connections M20 X 1.5
19 Standard Drawing - Stilling Well N/A 78 Crippled Mode Detection Required (NAMUR NE 043)
20 Stilling Well Material N/A 79 Burn-out Direction TBD
21 Stilling Well O.D. mm N/A 80 Calibrated Range % 0 - 100
22 Stilling Well Length mm N/A 81
23 Instrument Range 180 - 2420 82
24 CHAMBER : 83
25 Chamber Material Carbon Steel Group 1.1 84
26 Chamber Size / Centre to Centre mm 3" Sch STD 2240 85
27 Vessel Connection Side-Side 86
28 Flange Size/Rating/Facing 2" 300# RF 87
29 Vent / Drain Required Required 88
30 Vent / Drain Connection Flanged 89
31 Vent/Drain Flange Size/Rating/Facing 1" 300# RF 90
32 91
33 PROCESS DATA : 92 SPECIAL REQUIREMENTS :
34 Lower Fluid Name Wash Oil 93 NACE Requirements N/A
35 Upper Fluid Name Nitrogen 94 Certification Authority VTA
36 Fluid State Lower / Upper Liquid Gas/Vapor 95 Certification Approval No. VTA
37 Operating Conditions Min Norm Max 96 Material Certificate See Notes
38 Pressure barg 1 97 Test Requirements See Notes
39 Temperature °C 27,2 98 Special Requirements for Service See Notes
40 Lower Density kg/m³ 985 99 Fire Safe Design N/A
41 100 Paint Finish Mfr. STD
42 Lower Specific Gravity 101 Lightning Protection
43 102 Weight kg VTA
44 Normal Level mm Above Tangent Line 103
45 Design Pressure Min/Max barg -1,01 8 104
46 Design Temperature Min/Max °C -18,3 65 105
47 Dielectric Constant Upper/Lower 1 2,7 106 NON-VENDOR RELATED INFO :
48 Corrosive Agents Upper/Lower No No 107 Protection
49 Toxic Agents Upper/Lower No No 108 Tracing Temperature °C
50 Fluid Type / Service Identification 109 SAP Class
51 110 SAP Code
52 111
53 112 Req No.: 7650-8550-RQ-500-6013
54 PURCHASE DATA : 113 REMARKS :
55 Manufacturer 114 See notes
56 Model Number 115
57 Serial Number 116
58 Purchase Order Number 117
59 Item Number 118

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER


EE1 AS PHC SCA 27/12/2022 FOR ENQUIRY Sheet S-51.1 of 102
No. By Chk App Date Revision Spec: 1321 DS No.: 7650-8550-DS-ECR-LZT-91311 Rev.: EE1
FW1321.psr Rev 1 GWR Level Transmitter Specification Print Date: 27/12/2022
DocuSign Envelope ID: F91BCC13-AEA3-4F8A-8CBC-E5DC99DC2F3A

Tag Number : ECR-LZT -91311

PROCESS NOTES:
1. PED classification: Fluid State: L / Group: 1.
2. Steam Out: 7 barg @210ºC and FV @125 °C
3. High High Level will activated UZ-91002 and closed of XZV-91201 in DMDS Storage Drum.

INSTRUMENT NOTES:
I-1. Gaskets Materials: Sp. Winding + Inner. Ring: Ss316, Filler: Graphite, Outer Ring: Ss316 3mm Thk, Low Stress.
I-2. Stud & Nut Materials: Astm A193 Gr. B7, S2 / Astm A194 Gr. 2h, S59 (Impact Tested).
I-3. Charpy Impact Tested At -20 Deg.C, Minimum 27 Joules Average And 20 Joules Minimum.

INSTRUMENT SPECIFICATION

GWR LEVEL TRANSMITTER

EE1 AS 27/12/2022 FOR ENQUIRY Sheet S-51.2 of 102


No. By Date Revision Code: 1321 Dwg. No.: 7650-8550-DS-ECR-LZT-91311 Rev.: EE1