ATX™ FELED Series Nonmetallic LED Luminaires

Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Applications
• For use in locations where:
— Hazardous areas are designated as Zone 1 and 2 – 21 and 22
— A high degree of corrosion resistance is required
— Protection against dirt, water and moisture is necessary
• Typical applications include:
— Oil refineries
— Petrochemical facilities
— Food processing plants
— Waste and water treatment plants
— Underground tunnels
— General manufacturing facilities
Features
• Available in 5000K or 4000K Color Temperatures.
• Meets photobiological requirement for Risk Group 0 (RG0).
• Easy to retrofit in same mounting footprint as Appleton’s FE
series nonmetallic fluorescent luminaires.
• Full range of lumen outputs, with light distribution equivalent to Standard Materials
Appleton’s FE series fluorescent luminaires. • Housing: fiberglass reinforced polyester
• Corrosion-resistant fiberglass reinforced polyester body and • Lens: polycarbonate
hinged polycarbonate lens. • Gasket: elastomer
• High impact resistance housing (20 Joules – IK10) from • Internal reflector: highly reflective white powder coated
-30 °C to +55 °C (-22 °F to +131 °F) ambient temperature aluminum
and wind profile for use in extreme offshore and onshore • Mounting accessories available in different materials such as
environments. gray painted aluminum, zinc plated steel, galvanized steel or
• 60,000+ hour LED life for years of maintenance free operation. 316 stainless steel
• Lightweight design, hinged cover with captive screws, and ATEX/IECEx Certifications and Compliances
terminal block wiring for easy installation and maintenance.
• Contemporary, low profile design suitable for tight spaces. • Certification Type: FELED
• Standard screw-type terminal block can accept 4 to 6 mm2 wire. — Gas: Zones 1 and 2
• Field replaceable LED driver. – Conforming to ATEX 2014/34/EU: II 2 G
• Industry-leading thermal management for safe, reliable – Type of Protection: Ex db eb mb IIC Gb
operation over wide temperature range. – Temperature Class: T6 to T5
• Universal, high efficiency, drivers cover voltage requirements for — Dust: Zones 21 and 22
100-240 Vac, 50/60 Hz +/- 10%. – Conforming to ATEX 2014/34/EU: II 2 D
• High power factor electronic ballast (>0.95). – Type of Protection: Ex tb IIIC Db
• Standard 2KV surge suppression. – Surface Temperature: +63 °C to +85 °C (+145 °F to +185 °F)
• M20 plug or M25 plug provided. • Ambient Temperature: -30 °C up to +55 °C
• Latch assembly and elastomer gasket seals against water and (-22 °F up to 122 °F/ +131 °F) (standard) and -20°C up to
dust ingress, IP66. +50 °C (-4 °F up to 122 °F) (emergency)
• Easily accessed for maintenance using Allen key or straight • EU Declaration of Conformity: 50317
blade screwdriver. • ATEX Certificate: LCIE 16 ATEX 3048X
• Central opening with unique patented release system to prevent • IECEx Certificate: IECEx LCIE 16.0038X
damage. • Index of Protection according EN/IEC 60529: IP66
• Can be horizontally or vertically mounted. • Impact Resistance (shock): IK10
• Positive safety switch disconnects power to LED’s and driver to • Photobiological Safety, IEC 62778 and IEC 62471: RG0
allow maintenance in hazardous locations.
• Available in 3 hour emergency version, including built-in monthly
self- test. Test results through multi-colored LED.
• Ex e battery with plug-in connector.
Options
• 3 Hours Emergency/Battery Back-Up available ;
— Add suffix -E to the end of the catalog number.
Example: FELED5CBDSADE

 Available for 5K lumen models only.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 1


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.
FELED 3 C BD S A D

Series: Color Temperature: Mounting Version: Options:


FELED - FELED Series C - Cool 5000K CCT S - Surface/Suspension Mount D - Diffused
Zone 1, 2, 21, 22 N - Neutral 4000K CCT Standard Wiring (single phase) E - 3H Emergency (combined) 
ATEX/IECEx Certified L - Surface/Suspension Mount
Dual Loop In/Out Through
Wiring (single phase)

Lumen Output : Voltage: Cable Entry:


3 - 3K Lumen Output BD - 100-240 Vac, A – Armored M20 
4 - 4K Lumen Output 50/60Hz N - Unarmored M25 
5 - 5K Lumen Output
7 - 7K Lumen Output

 All values displayed reflect typical values.


 Must order armored cable glands separately.
 Cable glands provided in luminaires with unarmored hub entries.
 Available for 5K lumen models only.

2 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Lumen
Line Current Amps Input Power Output Color Temp Length in Weight in
(50/60 Hz) Power Factor (Lumens) Efficacy CRI (CCT) m (ft) kg (lbs) Catalog Number
FELED3CBDSAD
0.28A @ 100V
FELED3CBDSND
2850 105 lm/w >70 5000K
FELED3CBDLAD
0.13A @ 240V
0.8 6.0 FELED3CBDLND
27W >0.95
(2.6) (13.2) FELED3NBDSAD
0.28A @ 100V
FELED3NBDSND
2500 95 lm/w >80 4000K
FELED3NBDLAD
0.13A @ 240V
FELED3NBDLND
FELED4CBDSAD
0.32A @ 100V
FELED4CBDSND
3600 114 lm/w >70 5000K
FELED4CBDLAD
0.15A @ 240V
0.8 6.0 FELED4CBDLND
32W >0.95
(2.6) (13.2) FELED4NBDSAD
0.32A @ 100V
FELED4NBDSND
3200 101 lm/w >80 4000K
FELED4NBDLAD
0.15A @ 240V
FELED4NBDLND
FELED5CBDSAD
0.39A @ 100V
FELED5CBDSND
4650 122 lm/w >70 5000K
FELED5CBDLAD
0.16A @ 240V
1.4 9.0 FELED5CBDLND
38W >0.95
(4.6) (19.8) FELED5NBDSAD
0.39A @ 100V
FELED5NBDSND
4150 110 lm/w >80 4000K
FELED5NBDLAD
0.16A @ 240V
FELED5NBDLND
FELED7CBDSAD
0.63A @ 100V
FELED7CBDSND
7050 111 lm/w >70 5000K
FELED7CBDLAD
0.30A @ 240V
1.4 11.0 FELED7CBDLND
63W >0.95
(4.6) (24.3) FELED7NBDSAD
0.63A @ 100V
FELED7NBDSND
6550 103 lm/w >80 4000K
FELED7NBDLAD
0.30A @ 240V
FELED7NBDLND

Visit our website at www.emerson.com or contact us at (800) 621-1506. 3


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Technical Data
Gas Dust
T Rating Surface T°
Position
Model Horizontal/ Ta= +40 °C Ta= +50 °C Ta= +55 °C Ta= +40 °C Ta= +50 °C Ta= +55 °C
Type Vertical (+104 °F) (+122 °F) (+131 °F) (+104 °F) (+122 °F) (+131 °F)

FELED3 70°C 80 °C 85 °C
T6 T6 T5
Standard
 (158 °F) (176 °F) (185 °F)

FELED4 64 °C 74 °C 79 °C
T6 T6 T6
Standard
 (147 °F) (165 °F) (174 °F)

FELED5 63 °C 73 °C 78 °C
T6 T6 T6
Standard
 (145 °F) (163 °F) (172 °F)

FELED5 63 °C 73 °C
T6 T6 — —
Emergency

 (145 °F) (163 °F)

FELED7 65 °C 75 °C 80 °C
T6 T6 T6
Standard
 (149 °F) (167 °F) (176 °F)

“T” Numbers Represent the Maximum Temperature


“T” # T1 T2 T3 T4 T5 T6

301-450 201-300 136-200 101-135 86-100 85


Temp.
Range
ºC (˚ºF) (547-842) (394-572) (277-392) (214-275) (187-212) (185)

4 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Ambient Temperature
Conduit/Cable Entries  Voltage °C (°F) T Rating Catalog Number
Standard 3K Lumens - 0.80 m (2.6ft)
M20 Standard  FELED3CBDSAD
M25 Standard  -30 up to +55 FELED3CBDSND
100/240 Vac, 50/60 Hz T5 @ 55°C
M20 Dual Loop In/Loop Out  (-22 up to +131) FELED3CBDLAD
M25 Dual Loop In/Loop Out  FELED3CBDLND
M20 Standard  FELED3NBDSAD
M25 Standard  -30 up to +55 FELED3NBDSND
100/240 Vac, 50/60 Hz T5 @ 55°C
M20 Dual Loop In/Loop Out  (-22 up to +131) FELED3NBDLAD
M25 Dual Loop In/Loop Out  FELED3NBDLND
Standard 4K Lumens - 0.80 m (2.6ft)
M20 Standard  FELED4CBDSAD
M25 Standard  -30 to +55 FELED4CBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 to +131 ) FELED4CBDLAD
M25 Dual Loop In/Loop Out  FELED4CBDLND
M20 Standard  FELED4NBDSAD
M25 Standard  -30 to +55 FELED4NBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 to +131) FELED4NBDLAD
M25 Dual Loop In/Loop Out  FELED4NBDLND
Standard 5K Lumens - 1.40 m (4.6ft)
M20 Standard  FELED5CBDSAD
M25 Standard  -30 up to +55 FELED5CBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 up to +131) FELED5CBDLAD
M25 Dual Loop In/Loop Out  FELED5CBDLND
M20 Standard  FELED5NBDSAD
M25 Standard  -30 up to +55 FELED5NBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 up to +131) FELED5NBDLAD
M25 Dual Loop In/Loop Out  FELED5NBDLND
Standard 7K Lumens - 1.40 m (4.6ft)
M20 Standard  FELED7CBDSAD
M25 Standard  -30 to +55 FELED7CBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 to +131) FELED7CBDLAD
M25 Dual Loop In/Loop Out  FELED7CBDLND
M20 Standard  FELED7NBDSAD
M25 Standard  -30 to +55 FELED7NBDSND
100/240 Vac, 50/60 Hz T6 @ 55°C
M20 Dual Loop In/Loop Out  (-22 to +131) FELED7NBDLAD
M25 Dual Loop In/Loop Out  FELED7NBDLND
Emergency 5K Lumens - 1.40 m (4.6ft)
M20 Standard  FELED5CBDSADE
M25 Standard  -20 up to +50 FELED5CBDSNDE
100/240 Vac, 50/60 Hz T6 @ 50°C
M20 Dual Loop In/Loop Out  (-4 up to +122) FELED5CBDLADE
M25 Dual Loop In/Loop Out  FELED5CBDLNDE
M20 Standard  FELED5NBDSADE
M25 Standard  -20 up to +50 FELED5NBDSNDE
100/240 Vac, 50/60 Hz T6 @ 50°C
M20 Dual Loop In/Loop Out  (-4 up to +122) FELED5NBDLADE
M25 Dual Loop In/Loop Out  FELED5NBDLNDE

 M20 entries are with brass earth continuity plate for armored cable. Must order armored cable glands separately. M25 entries are for non-armored cable. Cable
glands provided with luminaires with M25 unarmored hub entries.
 Standard cable entry provides 3 entries; 1 at one and 2 at the other end of the housing.
 Loop In/Loop Out through cable entry provides 3 entries; 1 at one and 2 at the other end of the housing.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 5


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Wiring Diagrams

Standard

Version
Version
:L :L Version
Version
:S:S

DualDual
LoopLoop
In/Out
In/Out
- Through
- Through
Wiring
Wiring
(Single
(Single
Phase)
Phase) Standard
Standard
(Single
(Single
Phase)
Phase)

3 entries,
3 entries,
1 at1one
at one
endend
andand
2 at2the
at the
other
other 3 entries,
3 entries,
1 at1one
at one
endend
andand
2 at2the
at the
other
other
PE
PE

PE
PE

PE
PE
N
LN
N
N
N
N

PE
PE

PE
PE
L
LL
L
L

N
N
N
N
LL
L
Emergency
L
Version : L Version : L Version : S Version : S

Dual Loop In/Out - Through


Dual Loop
WiringIn/Out
(Single
- Through
Phase) Wiring (Single Phase) Standard (Single Phase)
Standard (Single Phase)

3 entries, 1 at one end 3and


entries,
2 at the
1 atother
one end and 2 at the other 3 entries, 1 at one end 3and
PE entries,
2 at the
1 atother
one end and 2 at the other

PE
PE

PE
PE

PE
PE

PE
PE

PE

L’
L’

L’
L’
N

N
N

N
L
L

L
L
L’

L’
N

LN

N
L’

L’

L’

L’
N

LN
L

L
L

6 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Wiring Diagram Emergency Function Diagram


Mains Mains Lighting Switch ON Lighting Switch OFF
PE N L

Lighting ON
Switch

L’

OFF
L
Standard LED
N Lighting Fixture
PE

L’
L Emergency LED
N Lighting Fixture
PE

LED Status
Color Indication Function
LED Blinking Mains voltage available – Battery charging
Green
LED Continuous Mains voltage available – Battery connected and loaded
Green and Red LED Blinking Alternately (2s) Mains voltage available – Battery in repair mode
LED Blinking Mains voltage available – No battery connected OR defective
Mains voltage NOT available — Light unit powered by batteries
LED Continuous
Red (emergency mode)
Mains voltage NOT available — Battery low (emergency mode com-
LED Flashing
pleted)
Yellow (Orange) and another Mains voltage available— Last automatic or manual operational check
LED Blinking Alternately
color has been unsuccessful
None (Off) No Light Emitted Mains voltage NOT available — Battery completely empty
Self-Test: In 3 month intervals batteries are automatically discharged and recharged once.

Emergency Light Duration


Version Battery Capacity Duration Light Output

5K 7 Ah – 6V 3 hours 25%

Visit our website at www.emerson.com or contact us at (800) 621-1506. 7


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Accessories and Replacement Parts

Description Catalog Number


Fixing Brackets
Set of two brackets for surface installation

Zinc plated steel FEFBZ

Brackets for Surface Mounting

Set of two

316 stainless steel FESBS

M8 Ring Bolts
Set of two

Zinc plated steel


FERBM8Z

Half Clamps Brackets for Pole Mounting


Set of two
Diameter for 1-1/4 to 1-1/2" pole: 42 mm (1.65 in) to 49 mm (1.93 in)
Zinc plated steel FEHC49Z
316 stainless steel FEHC49S
Diameter for 2" pole: 60 mm (2.36 in)
Zinc plated steel FEHC60Z
316 stainless steel FEHC60S
Hinged Brackets

Set of two brackets for adjusting luminaire


Aluminum FEHBA
316 stainless steel FEHBS
Fall Prevention Kit

Safety chain retains fixture temporarily to ease installation


For M25 cable entry FESCM25
For M20 cable entry FESCM20

8 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Accessories and Replacement Parts

Description Catalog Number


Replacement Drivers and Inverter

FELED3 - Standard Models Driver (qty: 1) Z00936

FELED4 - Standard Models Driver (qty: 1) Z00937

FELED5 - Standard and Emergency Models Driver (qty: 1) Z00928

FELED5 - Emergency Models Inverter (qty: 1) Z00930

FELED7 - Standard Models Driver (qty: 1) Z00937 

Replacement Lens

0.79 m (2.6 ft) clear polycarbonate external lens with gasket Z00650

1.39 m (4.6 ft) clear polycarbonate external lens with gasket Z00651

Replacement Diffuser

0.79 m (2.6 ft) diffused internal lens for FELED3 and FELED4 Models FELED2DPL

1.39 m (4.6 ft) diffused internal lens for FELED5 and FELED7 Models FELED4DPL

Replacement LED Arrays

5000K CCT LED Array


Z00941
FELED3C (qty: 1) - FELED4C (qty: 2) - FELED5C and FELED7C (qty: 4)

4000K CCT LED Array


Z00942
FELED3N (qty: 1) - FELED4N (qty: 2) - FELED5N and FELED7N (qty: 4)
Battery Pack

Battery Pack 6V 7Ah for FELED5 Emergency version Z00848

 Utilizes two drivers.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 9


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Mounting Options Dimensions in Millimeters (Inches)


FEFBZ: zinc plated steel — Set of two quick fixing brackets for ease of surface mounting

9.0 mm
(0.35")

64 mm
(2.52")
9.0 mm
(0.16")

30 mm
(1.18")

8.5 mm
(0.33")
8.5
25.0 mm (0.98")
49.0 mm (1.93")

FESBS: 316 stainless steel — Set of two brackets for surface mounting

232 mm (9.13")
200 mm (7.87")
38.0 mm
(1.50")
13.0 mm
(0.51")

32.0 mm
(1.26")
9.5 mm
(0.37")
9.5

14.5
14.5mm (0.57")

FERBM8Z: zinc plated steel — Set of two ring bolts

20.0 mm
(0.79")

8.0 mm
(0.31")
15.0 mm 36.0 mm
(0.59") (1.42")

M8x31.8 mm
M 8(1.25")
x 1.25

10 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Mounting Options Dimensions in Millimeters (Inches)


FEHC49Z: zinc plated steel or FEHC49S: 316 stainless steel — Set of two clamps for pole diameter 42 mm to 49 mm (for 1-1/4” to 1-1/2" pole).
FEHC60Z: zinc plated steel or FEHC60S: 316 stainless steel — Set of two clamps for pole diameter 60 mm (for 2” pole).

95 for 31.8 mm (1.25")


or 38.1 mm (1.50")

75.0 mm
(2.95”)

14.0 mm
(0.55”) or 84 for 50.8 mm (2.00")
31.8 mm (1.25")
or 38.1 mm (1.50")

m
m )
60 6”
85 mm Ø (2.3
(3.31”)

14.0 mm
(0.55”) 50.8 mm
(2.00")

FEHBA: aluminum or FEHBS: 316 stainless steel — Set of two hinged brackets for adjusting luminaire.
32.0 mm
5.5 mm (1.26”)
(0.22”)
82 18.0 mm
.
(3. 0 m
(3. 0 mm

23 m (0.71”)
”)
”)
03
.
77

132 mm (5.20”)
30°

100.0 mm
60
30

90

(3.94”)
14.5 mm
0

30
60
(0.57”)
90

30°

M8x31.8 mm
(1.25")
41.0 mm 13.0 mm 9.5 mm
(1.61”) (0.51”) (0.37”)

Visit our website at www.emerson.com or contact us at (800) 621-1506. 11


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Luminaire Dimensions in Millimeters (Inches)

145.0 mm
(5.71")

217.0 mm
(8.54")

End View

400.0 mm 2 X M8
(15.75")

785.0 mm (30.91")

Side View — 0.785 m (2.58 ft)

2 X M8
700.0 mm (27.56")

1390.0 mm (54.72")

Side View — 1.39 m (4.56 ft) Version

12 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Photometric Data — DATA SHOWN IS ABSOLUTE


3K Lumen Output with Diffuser, 5000K CCT
REPORT NUMBER: FELED3CBDXXD

Luminaire Lumens: 2,836

Polar Candela Distribution Isocandela Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


790
-80° -60° -40° -20° 0° 20° 40° 60° 80°
0-30 618.3 21.8% 21.8%
658 130° 80° 0-40 1,022.8 36.1% 36.1%
60° 0-60 1,850.6 65.2% 65.3%
527 60-90 786.1 27.7% 27.8%
120° 40°
395
70-100 558.0 19.7% 19.7%
20°
90-120 181.6 6.4% 6.4%
110° 0°
263 0-90 2,636.7 92.9% 93.1%
132 100°
-20° 90-180 195.4 6.9% 6.9%
-40° 0-180 2,832.1 99.8% 100%
0.00 90°
-60°
132 80° -80° Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
263
70° 0-10 74.3 2.6% 90-100 109.8 3.9%
Cd: 706, 90% Cd: 314, 40%
395
Cd: 588, 75% Cd: 235, 30% 10-20 214.6 7.6% 100-110 51.8 1.8%
60° Cd: 470, 60% Cd: 157, 20% 20-30 329.4 11.6% 110-120 20.1 0.7%
527 Cd: 392, 50% Cd: 78, 10%
30-40 404.5 14.3% 120-130 6.6 0.2%
658 50°
Point of Max Cd: 784.0 40-50 428.1 15.1% 130-140 2.7 0.1%
50-60 399.7 14.1% 140-150 1.9 0.1%
790 60-70 337.8 11.9% 150-160 1.4 0%
0° 10° 20° 30° 40° 70-80 263.0 9.3% 160-170 0.9 0%
-0° H 80-90 185.2 6.5% 170-180 0.3 0%
-90° H
3K Lumen Output with Diffuser, 4000K CCT
REPORT NUMBER: FELED3NBDXXD

Luminaire Lumens: 2,517

Polar Candela Distribution Isofoot Candle Plot ZONAL LUMEN SUMMARY


180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire
730
0-30 562.4 22.3% 22.3%
130° -80° -60° -40° -20° 0° 20° 40° 60° 80°
608 0-40 927.4 36.8% 36.8%
80°
0-60 1,665.5 66.2% 66.1%
487 60°
120° 60-90 686.9 27.3% 27.3%
365 40° 70-100 484.2 19.2% 19.2%
243
110° 20° 90-120 155.1 6.2% 6.2%
0° 0-90 2,352.4 93.4% 93.4%
122 100°
-20° 90-180 167.1 6.6% 6.6%
0.00 90°
-40° 0-180 2,519.6 100.1% 100%
122 80° -60°
-80° Lumens Per Zone
243
70° Zone Lumens % Total Zone Lumens % Total
365
Cd: 648, 90% Cd: 288, 40% 0-10 67.9 2.7% 90-100 94.4 3.7%
60° Cd: 540, 75% Cd: 216, 30% 10-20 195.5 7.8% 100-110 44.2 1.8%
487
Cd: 432, 60% Cd: 144, 20%
Cd: 360, 50% Cd: 72, 10% 20-30 298.9 11.9% 110-120 16.5 0.7%
608 50° 30-40 365.0 14.5% 120-130 5.4 0.2%
Point of Max Cd: 720.1
730
40-50 383.2 15.2% 130-140 2.4 0.1%
0° 10° 20° 30° 40° 50-60 354.8 14.1% 140-150 1.7 0.1%
60-70 297.1 11.8% 150-160 1.3 0.1%
-0° H 70-80 229.4 9.1% 160-170 0.9 0%
-90° H 80-90 160.4 6.4% 170-180 0.3 0%

Visit our website at www.emerson.com or contact us at (800) 621-1506. 13


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Photometric Data — DATA SHOWN IS ABSOLUTE


4K Lumen Output with Diffuser, 5000K CCT
REPORT NUMBER: FELED4CBDXXD

Luminaire Lumens: 3,604

Polar Candela Distribution Isocandela Plot ZONAL LUMEN SUMMARY


180° 170° 160° 150° 140°
1,100 Zone Lumens % Lamp % Luminaire
-80° -60° -40° -20° 0° 20° 40° 60° 80°
0-30 799.3 22.2% 22.2%
917 130°
80° 0-40 1,316.8 36.5% 36.5%
733 60° 0-60 2,361.2 65.5% 65.5%
120° 60-90 992.0 27.5% 27.5%
550 40°
70-100 710.6 19.7% 19.7%
110° 20°
367 90-120 234.3 6.5% 6.5%
0° 0-90 3,353.2 93% 93%
183 100°
-20° 90-180 251.9 7% 7%
0.00 90° -40° 0-180 3,605.1 100% 100%
183 80° -60°
-80° Lumens Per Zone
367
70° Zone Lumens % Total Zone Lumens % Total
550
Cd: 925, 90% Cd: 411, 40%
0-10 96.7 2.7% 90-100 139.9 3.9%
60° Cd: 771, 75% Cd: 308, 30% 10-20 278.1 7.7% 100-110 67.7 1.9%
733 Cd: 617, 60% Cd: 206, 20%
Cd: 514, 50% Cd: 103, 10%
20-30 424.6 11.8% 110-120 26.6 0.7%
917 50° 30-40 517.5 14.4% 120-130 8.9 0.2%
Point of Max Cd: 1,029.0
40-50 542.7 15.1% 130-140 3.3 0.1%
1,100
0° 10° 20° 30° 40°
50-60 501.7 13.9% 140-150 2.1 0.1%
60-70 421.2 11.7% 150-160 1.8 0.1%
-0° H 70-80 333.1 9.2% 160-170 1.1 0%
80-90 237.6 6.6% 170-180 0.4 0%
-90° H

4K Lumen Output with Diffuser, 4000K CCT


REPORT NUMBER: FELED4NBDXXD

Luminaire Lumens: 3,197

Polar Candela Distribution Isofoot Candle Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°


Zone Lumens % Lamp % Luminaire
900 0-30 703.8 22% 22%
-80° -60° -40° -20° 0° 20° 40° 60° 80°
130°
0-40 1,163.6 36.4% 36.4%
750 80°
0-60 2,097.5 65.6% 65.6%
60°
600 60-90 889.6 27.8% 27.8%
120° 40°
450
70-100 631.3 19.7% 19.8%
20° 90-120 197.5 6.2% 6.2%
110°
300
0° 0-90 2,987.1 93.4% 93.5%
150 100° -20° 90-180 208.5 6.5% 6.5%
-40° 0-180 3,195.6 100% 100%
0.00 90°
-60°
150 80°
-80° Lumens Per Zone
300
70° Zone Lumens % Total Zone Lumens % Total
450
0-10 84.8 2.7% 90-100 120.0 3.8%
Cd: 807, 90% Cd: 359, 40%
60° Cd: 673, 75% Cd: 269, 30% 10-20 244.4 7.6% 100-110 56.3 1.8%
600 Cd: 538, 60% Cd: 179, 20% 20-30 374.6 11.7% 110-120 21.2 0.7%
Cd: 449, 50% Cd: 90, 10%
750
30-40 459.8 14.4% 120-130 6.1 0.2%
50° Point of Max Cd: 897.0 40-50 484.7 15.2% 130-140 2.0 0.1%
900 50-60 449.2 14.1% 140-150 1.2 0%
0° 10° 20° 30° 40° 60-70 378.2 11.8% 150-160 0.9 0%
70-80 300.0 9.4% 160-170 0.6 0%
-0° H 80-90 211.3 6.6% 170-180 0.2 0%
-90° H

14 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety


ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Photometric Data — DATA SHOWN IS ABSOLUTE


5K Lumen Output with Diffuser, 5000K CCT
REPORT NUMBER: FELED5CBDXXD

Luminaire Lumens: 4,651

Polar Candela Distribution Isocandela Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


1,400
-80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 1,034.8 22.2% 22.3%
1,167 130° 80° 0-40 1,713.1 36.8% 36.9%
60° 0-60 3,090.1 66.4% 66.5%
933
40° 60-90 1,276.8 27.4% 27.5%
120°
700 70-100 884.6 19% 19%
20°
90-120 262.1 5.6% 5.6%
110° 0°
467
0-90 4,366.9 93.9% 94%
-20°
233 100° 90-180 280.6 6% 6%
-40° 0-180 4,647.5 99.9% 100%
0.00 90°
-60°
233 80° -80° Lumens Per Zone
467 Zone Lumens % Total Zone Lumens % Total
70°
Cd: 1,182, 90% Cd: 525, 40% 0-10 124.3 2.7% 90-100 163.3 3.5%
Cd: 985, 75% Cd: 394, 30%
700 10-20 358.7 7.7% 100-110 71.9 1.5%
Cd: 788, 60% Cd: 263, 20%
933
60° Cd: 657, 50% Cd: 131, 10% 20-30 551.9 11.9% 110-120 26.8 0.6%
Point of Max Cd: 1,313.0
30-40 678.3 14.6% 120-130 8.7 0.2%
1,167 50° 40-50 714.3 15.4% 130-140 3.7 0.1%
50-60 662.7 14.3% 140-150 2.4 0.1%
1,400
0° 10° 20° 30° 40° 60-70 555.5 12.0% 150-160 1.9 0%
70-80 427.8 9.2% 160-170 1.3 0%
-0° H 80-90 293.5 6.3% 170-180 0.4 0%
-90° H

5K Lumen Output with Diffuser, 4000K CCT


REPORT NUMBER: FELED5NBDXXD

Luminaire Lumens: 4,152

Polar Candela Distribution Isofoot Candle Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°


Zone Lumens % Lamp % Luminaire
1,200 0-30 927.9 22.3% 22.4%
-80° -60° -40° -20° 0° 20° 40° 60° 80°
130°
0-40 1,534.5 37% 37%
1,000 80°
0-60 2,764.3 66.6% 66.6%
60°
800 60-90 1,138.7 27.4% 27.4%
120° 40°
600
70-100 787.5 19% 19%
20° 90-120 231.2 5.6% 5.6%
110°
400 0° 0-90 3,903.0 94% 94.1%
200 100° -20° 90-180 246.9 5.9% 5.9%
-40° 0-180 4,149.9 99.9% 100%
0.00 90°
-60°
200 80° -80° Lumens Per Zone
400
70° Zone Lumens % Total Zone Lumens % Total
Cd: 1,060, 90% Cd: 471, 40% 0-10 111.5 2.7% 90-100 144.2 3.5%
600 Cd: 884, 75% Cd: 353, 30%
10-20 321.8 7.8% 100-110 63.5 1.5%
60° Cd: 707, 60% Cd: 236, 20%
800 Cd: 589, 50% Cd: 118, 10% 20-30 494.6 11.9% 110-120 23.4 0.6%
Point of Max Cd: 1,178.0
30-40 606.6 14.6% 120-130 7.4 0.2%
1,000 50° 40-50 638.2 15.4% 130-140 3.0 0.1%
1,200
50-60 591.6 14.3% 140-150 2.1 0%
0° 10° 20° 30° 40° 60-70 495.5 11.9% 150-160 1.7 0%
70-80 382.1 9.2% 160-170 1.1 0%
-0° H 80-90 261.2 6.3% 170-180 0.4 0%
-90° H

Visit our website at www.emerson.com or contact us at (800) 621-1506. 15


© January 2018
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/Area: NEC/CEC Explosionproof/ATEX/IECEx Flameproof/Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Photometric Data — DATA SHOWN IS ABSOLUTE


7K Lumen Output with Diffuser, 5000K CCT
REPORT NUMBER: FELED7CBDXXD

Luminaire Lumens: 7,038

Polar Candela Distribution Isocandela Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


2,000
-80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 1,522.2 21.6% 21.6%
1,667 130° 80° 0-40 2,519.1 35.8% 35.8%
60° 0-60 4,554.8 64.7% 64.7%
1,333
40° 60-90 1,954.8 27.8% 27.8%
120°
1,000 70-100 1,427.0 20.3% 20.3%
20°
110°
90-120 500.5 7.1% 7.1%
667 0°
0-90 6,509.6 92.5% 92.4%
-20°
333 100° 90-180 533.4 7.6% 7.6%
-40° 0-180 7,043.0 100.1% 100%
0.00 90°
-60°
333 80° -80° Lumens Per Zone
667
Zone Lumens % Total Zone Lumens % Total
70°
Cd: 1,742, 90% Cd: 774, 40% 0-10 182.9 2.6% 90-100 299.7 4.3%
Cd: 1,451, 75% Cd: 581, 30%
1,000 10-20 527.8 7.5% 100-110 142.6 2%
Cd: 1,161, 60% Cd: 387, 20%
60° Cd: 968, 50% Cd: 194, 10% 20-30 811.5 11.5% 110-120 58.1 0.8%
1,333
Point of Max Cd: 1,935.0
30-40 996.8 14.2% 120-130 17.3 0.2%
1,667 40-50 1,053.3 15.0% 130-140 5.9 0.1%
50°
50-60 982.5 13.9% 140-150 3.9 0.1%
2,000 60-70 827.5 11.7% 150-160 3.1 0%
0° 10° 20° 30° 40°
70-80 646.8 9.2% 160-170 2.0 0%
-0° H 80-90 480.5 6.8% 170-180 0.7 0%
-90° H
7K Lumen Output with Diffuser, 4000K CCT
REPORT NUMBER: FELED7NBDXXD

Luminaire Lumens: 6,540

Polar Candela Distribution Isofoot Candle Plot ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°


Zone Lumens % Lamp % Luminaire
1,900 0-30 1,437.8 22% 22%
-80° -60° -40° -20° 0° 20° 40° 60° 80°
130°
0-40 2,375.3 36.3% 36.4%
1,583 80°
0-60 4,274.2 65.3% 65.5%
60°
1,267 60-90 1,801.5 27.5% 27.6%
120° 40°
950
70-100 1,292.3 19.8% 19.8%
20° 90-120 428.3 6.5% 6.6%
110°
633 0° 0-90 6,075.7 92.9% 93.1%
317 100° -20° 90-180 452.2 6.9% 6.9%
-40° 0-180 6,527.9 99.8% 100%
0.00 90°
-60°
317 80° -80° Lumens Per Zone
633
70° Zone Lumens % Total Zone Lumens % Total
Cd: 1,649, 90% Cd: 733, 40% 0-10 173.1 2.7% 90-100 258.9 4%
950 Cd: 1,374, 75% Cd: 550, 30%
10-20 499.0 7.6% 100-110 122.4 1.9%
60° Cd: 1,099, 60% Cd: 366, 20%
1,267 Cd: 916, 50% Cd: 183, 10% 20-30 765.7 11.7% 110-120 47.0 0.7%
Point of Max Cd: 1,832.0
30-40 937.5 14.4% 120-130 12.5 0.2%
1,583 50° 40-50 985.2 15.1% 130-140 4.3 0.1%
1,900
50-60 913.7 14.0% 140-150 2.8 0%
0° 10° 20° 30° 40° 60-70 768.1 11.8% 150-160 2.3 0%
70-80 600.6 9.2% 160-170 1.5 0%
-0° H 80-90 432.7 6.6% 170-180 0.5 0%
-90° H

16 Visit our website at www.emerson.com or contact us at (800) 621-1506.