0% found this document useful (0 votes)
925 views

Fumis Table With All Errors

This document contains a table listing various alert and error codes, descriptions, and recommended actions for resolving issues that may occur with a heating device. The table includes 17 alert/error codes related to issues like low fuel level, maintenance needs, sensor failures, and other device or communication errors. Recommended actions for the user include refueling the tank, calling for service, checking for blockages, and resetting alarms; or contacting service for sensor, component, or software issues.

Uploaded by

connan2014
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
925 views

Fumis Table With All Errors

This document contains a table listing various alert and error codes, descriptions, and recommended actions for resolving issues that may occur with a heating device. The table includes 17 alert/error codes related to issues like low fuel level, maintenance needs, sensor failures, and other device or communication errors. Recommended actions for the user include refueling the tank, calling for service, checking for blockages, and resetting alarms; or contacting service for sensor, component, or software issues.

Uploaded by

connan2014
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Alert/error Alert/error Android/iOS Alpha UI Simbols

Alert/error description Notes


code Log code Application

A001 / A001 Low fuel Warning fuel level, refuel the tank.
Blinking

Time to service expired, call service


A002 / A002 Maintenance
Blinking for regular maintenance.
Flue gases temperature warning
A003 8 A003 Cleaning level. Chimney or heat exchanger
Blinking
cleaning required.
Low battery, call service for its
A004 / A004 Low battery
Blinking replacement.

Combustion Fan RPM sensor failure,


A005 / A005 Speed sensor
Blinking call service.

A006 239 A006 Door opened Door open, close the door.
Blinking

Pressure/airflow Airflow sensor malfunctioned, call


A007 / A007
Blinking sensor service.

Alpha UI keyboard User interface display error, call


E001 / /
Lit error service.

IR communication Infrared sensor malfunctioned, call


E002 / /
Lit error service.

RF Communication RF Communication error, call


E003 / /
Lit error sersvice
No communication between
MB communication
E004 / E001 controller motherboard and user
Lit error
interface, call service
Error, caused by: 1. Ignition failed,
E101 240 E101 Fire error
Lit 2. water over temperature, 3.
backfire protection. If the error
persists, call service.

Error, caused by: 1. Chimney, air


inlet tube or burning pot dirty. 2.
E102 241 E102 Chimney dirty manually stopped device before
Lit
flame detection. If the error
persists, call service.

NTC2 temperature sensor failure,


E105 244 E105 NTC2
Lit call service

NTC3 temperature sensor failure,


E106 245 E106 NTC3
Lit call service

TC2 temperature sensor failure, call


E107 246 E107 TC2
service
Lit
STB or pressure switch triggered.
Reset the alarm/switch and restart
E108 247 E108 Security switch error
Lit the device. If the error persists, call
service.
STB or pressure switch triggered.
Reset the alarm/switch and restart
E109 248 E109 Pressure switch error
Lit the device. If the error persists, call
service.

NTC1 temperature sensor failure,


E110 249 E110 NTC1
Lit call service

TC1 temperature sensor failure, call


E111 250 E111 TC1
Lit service

Gases over Flue gases over temperature.


E113 252 E113
Lit temperature Chimney or heat exchanger cleaning
required. If the error persists, call
service.
Fuel Ignition timeout expired
(empty the burning pot and restart
E114 253 E114 No pellets
Lit the device) or fuel tank empty
(refuel the tank).
Motherboard controller error, call
E115 254 E115 General error
Lit service.
/ / Heating device / / WiRCU module not powered or
not connected without internet connection.
/ / No response / / Cloud service currently unavailable.
from cloud Please try later.
/ / No internet / / Your smart device is not connected to
connection the internet.

You might also like