Currenza-C2 Operating-Instructions EN PDF
Currenza-C2 Operating-Instructions EN PDF
Table of contents
Safety instructions 3
Operating elements 3
Blue version 3
White version 4
Configuration of the coin changer 5
Menu structure 6
Abbreviations in the menu 6
Menu: Audit 7
Submenu: General Data 7
Submenu: Vends 8
Submenu: Flow of money 9
Menu: Inventory 11
Menu: Service 12
Submenu: Show payout combination 12
Submenu: Coin Management 13
Payout statistic 13
Proposals for optimization 13
Submenu: Token Teach 14
Teach token 14
Menu: Diagnostic 16
Submenu: Validator module 16
Submenu: Changer module 16
Submenu: Payout module 17
Submenu: Audit module 17
Submenu: Display module 17
Menu: Settings 18
Submenu:Operating modes 18
Submenu:Selling prices (BDV/Executive) 20
Submenu:Inhibit mask 20
Submenu: Peripheral 21
Submenu: Coin settings 22
Submenu: Other settings 24
Submenu: Audit module 25
Menu: Filling mode 26
2
SAFETY INSTRUCTIONS
Before operating the device for the first time, please read the safety
instructions and the respective manuals for this product at least once to
ensure you have understood the proper use of the device, the handling
instructions and the requirements in respect of staff qualification for
installation and maintenance, and the necessary protective measures. All
information about this product is available at suzohapp.com.
OPERATING ELEMENTS
The currenza c2 coin changer series includes two models. While the
housing dimensions and design are the same, a distinction is made between
the versions Blue and White. Only the operating elements
are different on the two versions.
Blue version
The human interface, the operating device for the user, consists of a
keyboard with seven keys and a display.
3
White version
The White version has no operating elements on the control panel. The user
interface is made available via the separate setting module HENRI or via the
respective vending machine (provided this function is supported).
4
CONFIGURATION OF THE COIN CHANGER
i Info
Inhibited
by vending
machine
Fig. 5: Example of a message
5
Please press the MENU key to open the main menu.
A = Audit
B = Inventory
C = Service
D = Diagnostic
E = Settings
F = Filling
Back: MENU
Menu structure
Navigation within the menu structure is simple. Select the desired menu in
the main menu by pressing the key with the letter A, B, C, D, E or F shown
on the left of the menu.
Example: Press the key with the letter E to change to the Settings menu.
Use the keys "Arrow up" or "Arrow down" to navigate within the
menus. Press the "OK“ key to change to a selected submenu . Press the
"EXIT“ key to change to the higher-ranking menu. Change to the main
menu with the MENU key.
All menus contain a help text for navigation within the menu in
the bottom part.
6
Menu: Audit
The main menu is displayed: Press key A to change to the Audit menu. You
can access all audit data via the Audit menu. The following overview shows
the submenus available.
7
Submenu: Vends
The Audit menu is displayed: Select the Vends submenu using the "Arrow
up“ or "Arrow down“ key and press the "OK" key . In this menu
you can inform yourself about the sales effected via the coin changer.
Vends
Sales of all payment sources
(s. Ini. 0000.00 | s. l. R. 0000.00;
Number: s. Ini. 000000 | s. l. R. 000000)
Cash sales
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Cashless sales
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Token sales
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Free vends
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Free vends with Token
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Test vends
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Discounts
(s. Ini. | s. l. R.; see “Sales of all payment sources”)
Sales per selection line
(Selection 001 [bis 100]
s. Ini. | s. l. R.; see “Sales of all payment sources”)
8
Submenu: Flow of money
The Audit menu is displayed: Select the Flow of money submenu using the
"Arrow up“ or "Arrow down“ key and press the "OK" key . In this
menu you can inform yourself about the flow of money through the coin
changer.
Flow of money
Coin data
Coins to cash-box
(s. Ini. 0001.00 | s. l. R. 0001.00)
Coins to tube
(s. Ini. 0000.00 | s. l. R. 0000.00)
Change paid out
(s. Ini. 0000.00 | s. l. R. 0000.00)
Change paid out from Hopper
(s. Ini. 0000.00 | s. l. R. 0000.00)
Coins to tube in manual filling mode
(s. Ini. 0000.00 | s. l. R. 0000.00)
Coins paid out manually
(s. Ini. 0000.00 | s. l. R. 0000.00)
Cash overpay
(s. Ini. 0000.00 | s. l. R. 0000.00)
Credited from machine
(s. Ini. 0000.00 | s. l. R. 0000.00)
Coin counter
Counter: Accept
(Coin 01 [to 16]
s. Ini. 000000 | s. l. R. 000000)
Counter: In Tube
(Tube A [to F]: EUR 02.00
s. Ini. 000000 | s. l. R. 000000)
Counter: Paid out
(Tube A [to F]: EUR 02.00
s. Ini. 000000 | s. l. R. 000000)
9
Bill data
Accepted bills
(s. Ini. 0000.00 | s. l. R. 0000.00)
Bills to Recycler
(s. Ini. 0000.00 | s. l. R . 0000.00)
Bills paid out
(s. Ini. 0000.00 | s. l. R. 0000.00)
Bills in manually
(s. Ini. 0000.00 | s. l. R. 0000.00)
Bills out manually
(s. Ini. 0000.00 | s. l. R. 0000.00)
Cashless data
Debited from Cashless
(s. Ini. 0000.00 | s. l. R. 0000.00;
Number: s. Ini. 000000 | s. l. R. 000000)
Credited to Cashless
(s. Ini. 0000.00 | s. l. R. 0000.00;
Number: s. Ini. 000000 | s. l. R. 000000)
Discounts from Cashless
(s. Ini. | s. l. R. see “Credited to Cashless”)
Token from Cashless
(s. Ini. | s. l. R. see “Credited to Cashless”)
Token
Accepted Token
(s. Ini. 0000.00 | s. l. R. 0000.00)
Token overpay
(s. Ini. 0000.00 | s. l. R. 0000.00)
Freevend Token
(s. Ini. 0000.00 | s. l. R. 0000.00)
10
Menu: Inventory
The main menu is displayed: Press key B to change to the Inventory menu.
At first the current tube combination is displayed in the Inventory menu:
Inventory:
A F
2.00 C D 0.50
B 1.00 0.10 E
0.05 0.20
After about two to three seconds, the complete tube content including the
counter readings of the individual tubes are displayed:
Inventory:
A EUR F
000.00
000 000
B C D E
000 000 000 000
Fig. 8: Menu Inventory 2
You now can pay out one coin each by pressing the keys A, B, C, D, E or F.
11
Menu: Service
The main menu is displayed: Press key C to change to the Service menu.
Make the service settings via the Service menu.
Service (main menu, key C)
Show payout combination
Coin Management
Token Teach
the "OK" key . The current payout or tube combination of the coin
changer is displayed in this menu.
Tube cassette
A F
2.00 C D 0.50
B 1.00 0.10 E
0.05 0.20
12
Submenu: Coin Management
The Service menu is displayed: Select the Coin Management submenu
using the "Arrow up“ or "Arrow down“ key and press the "OK" key
Payout statistic
Coin Management
Payout statistic
(A [to F]: EUR 00.50 ???)
Status of Analysis
(Example: 100 % | Analysis completed)
Proposals for optimization
The amount of coins inserted and paid out again is displayed for each tube
in per cent (highlighted in cyan, see above).
13
Submenu: Token Teach
The Service menu is displayed: Select the Token Teach submenu using the
"Arrow up“ or "Arrow down“ key and press the "OK" key .
Token Teach
Token teach
Token A
1: “Please insert coins...”
2: “Inserted: 00”
...
3: “Inserted: 10”
4: “Continue: OK”
5: “Select acceptance band: A = normal | B = wide”
Token B
(see Token A)
Token C
(see Token A)
Token delete
Token A
Token B
Token C
Machine interface MDB: the token value is set in the vending
machine.
Machine interface BDV/Executive: the token value is set in
the submenu Coin settings of this coin changer.
Teach token
Proceed as described below to teach a token:
1 Select the desired token in the submenu Token teach: token A,
token B or token C.
You are requested to insert coins via the display:
2 Insert ten coins minimum.
14
After insertion of the tenth coin the following display appears: "Continue:
OK“
i Info
Token just
programmed
i Info
Token
could not
be programmed
15
Menu: Diagnostic
The main menu is displayed: Press key D to change to the Diagnostic
menu. The Diagnostic menu serves to perform functional tests for various
components of the coin changer.
Diagnostic (main menu, key D)
Validator module
Changer module
Payout module
Audit module
Display module
16
Submenu: Payout module
The Diagnostic menu is displayed: Select the Payout module submenu
using the "Arrow up“ or "Arrow down“ key and press the "OK" key
17
Menu: Settings
The main menu is displayed: Press key E to change to the Diagnostic menu.
Configuration of the coin changer is performed via the Settings menu.
Settings (main menu, key E)
Operating modes
Selling prices (only BDV/Executive)
Inhibit mask
Peripheral
Coin settings
Other settings
Audit module
Submenu:Operating modes
The Settings menu is displayed: Select the Operating modes submenu
using the "Arrow up“ or "Arrow down“ key and press the "OK" key
. In this menu you can configure the operating modes of the coin
changer, e. g. the functions of the inventory keys.
18
Operating modes - BDV / Executive
Configure inventory keys
(keys enabled, keys blocked)
Selling mode
Single or Multi vend
(Single vend, Multi vend)
Committed to vend
(not active, active)
Price Holding
Price Holding
(not active, active)
Indicate price
(not active, active)
2 price lists with Cashless
(not active, active)
Limitations
Acceptance limit
(000.00)
Change limit
(000.00)
Credit limit for Cashless
(000.00)
Residual credit
(not delete, delete)
Only tube coins in filling mode
(not active, active)
Tube counter correction
(not active, active)
19
Operating modes - MDB
Configure inventory keys
(keys enabled, keys blocked)
Security stock in the tubes
(payable | not payable)
Inhibit bill acceptance
(not active | active)
Security stock to VMC
(send to VMC | not send to VMC)
Only tube coins in filling mode
(not active, active)
Tube counter correction
(not active, active)
Submenu:Selling prices (BDV/Executive)
This menu is only available when the machine interface BDV /
Executive is used.
The Settings menu is displayed: Select the Selling prices submenu using
the "Arrow up“ or "Arrow down“ key and press the "OK" key .
You can assign a value to up to one hundred prices.
Submenu:Inhibit mask
The Settings menu is displayed: Select the Inhibit mask submenu using
the "Arrow up“ or "Arrow down“ key and press the "OK" key .
In this menu you can release or block coins (01 to 16) individually.
20
Submenu: Peripheral
The Settings menu is displayed: Select the Peripheral submenu using the
"Arrow up“ or "Arrow down“ key and press the "OK" key . In this
menu you can configure the data exchange with peripheral units.
Peripheral
Cashless - only BDV / Executive
BDV Cashless
(not active | active)
BDV Cashless (Standard address)
(not active | active)
MDB Cashless (address 0x60)
(not active | active)
Bill validator - only BDV / Executive
Bill validator
(not active | active)
Enable bill acceptance
(if not empty | if card is present | always)
Audit unit in the machine - only BDV / Executive
(not active | active)
Bill recycler
(not active | active)
Hopper
Communication with Hopper
(not active | active)
Coin signal of Hopper
(Low-active | High-active)
Empty signal of Hopper
(Low-active | High-active)
Coin value in Hopper 1
(00.00)
Coin value in Hopper 2
(00.00)
Coin value in Hopper 3
(00.00)
Coin value in Hopper 4
(00.00)
21
The peripheral units which are supported depend on the
machine interface used (BDV/Executive or MDB).
22
Coin settings
Filling level limitation
(Tube A [to e.g. F]:
actual value / change in value [from 000 to 199])
Security stock
(Tube A [to e.g. F]:
actual value / change in value [from 00 to 09])
Coin sorting
Select tube cassette
(Tube cassettes 01 to 08)
New payout combination
(Sorting tube A [to e.g. F]: EUR 00.00;
actual value, value in change)
Token
Setting of token value
Value of token A (00.00)
Value of token B (00.00)
Value of token C (00.00)
Setting of free vend token
Token A as free vend token
(no free vend | free vend)
Token B as free vend token
(no free vend | free vend)
Token C as free vend token
(no free vend | free vend)
Condition for Tube Empty - only BDV / Executive
(0... 99)
Security level
(Coin 01 [to 16]: normal | narrow | very narrow)
23
Submenu: Other settings
The Settings menu is displayed: Select the Other settings submenu using
the "Arrow up“ or "Arrow down“ key and press the "OK" key .
In this menu you can make general settings for the coin changer, e. g.
language and currency code.
Other settings
Base coin value
(00.00)
Language
(German | English | French | Spanish)
Currency Code
(1234)
MDB-Level
(Level 2 | Level 3)
Display contrast
(00)
Wake-up time
(00)
24
Submenu: Audit module
The Settings menu is displayed: Select the Audit module submenu using
the "Arrow up“ or "Arrow down“ key and press the "OK" key .
In this menu you can make the settings for the vouchers.
Audit module
Machine number
(000000)
Configurate printer interface
Time
(not printed | printed)
Product-specific data
(not printed | printed)
Sales data
(not printed | printed)
Start button on printer
(not exists | exists)
Printer format
(12 characters | 24 characters)
Set system Date
(00.00.00)
Set system Time
(00.00.00)
25
Menu: Filling mode
The main menu is displayed: Press the key F to change to the Filling mode
menu. At first the current tube combination is displayed in the Filling mode
menu:
Tube filling:
A F
2.00 C D 0.50
B 1.00 0.10 E
0.05 0.20
After about two to three seconds, the complete tube content including the
counter readings of the individual tubes are displayed:
Tube filling:
A EUR F
000.00
000 000
B C D E
000 000 000 000
26