SF320A Manual 704181UK

The document provides mounting instructions for flow sensors. It states that the sensor tip must be completely immersed in the medium being monitored. It provides guidelines for mounting the sensor horizontally or vertically depending on the pipe orientation. Minimum distances between sensors and bends/valves are specified to avoid malfunctions. Scale drawings with dimensions are included for different sensor models. Tightening torques and recommended insertion depths are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views8 pages

SF320A Manual 704181UK

The document provides mounting instructions for flow sensors. It states that the sensor tip must be completely immersed in the medium being monitored. It provides guidelines for mounting the sensor horizontally or vertically depending on the pipe orientation. Minimum distances between sensors and bends/valves are specified to avoid malfunctions. Scale drawings with dimensions are included for different sensor models. Tightening torques and recommended insertion depths are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Operating instructions /

Mounting instructions
Flow sensor UK

SF***A
06 / 2012
704181 / 02
Before installation, read the safety-related section of the operating
instructions, enclosed separately!

1 Installation
The sensor tip must be completely immersed in the medium.
• In the case of horizontal pipes mount the unit from the side, if possible (fig. 1).
- When the unit is to be mounted at the bottom of the pipe, it should be free
from deposits.
- When the unit is to be mounted at the top of the pipe, it should be completely
filled with the medium to be monitored.
• In the case of vertical pipes mount the unit in a place where the medium flows
upwards (fig. 2).
1 A 2 A

B
B

A: mounting bush (15 mm for units with M12 x 1 and G¼ thread; 33 mm for units with G½
thread).
B: packing washer
To avoid malfunction a minimum 3
distance between the flow monitor and B
bends, valves or such like must be ob-
served (fig 3). Min. 5 x pipe diameter min.
upstream (A), min. 3 x pipe diameter 3xD
downstream (B).
min.
D 5xD

2
2 Ceramic units
Max. tightening torque: 8Nm for units with G¼ thread; 30Nm for units with G½
thread.
The thread of the mounting bush must be clean, undamaged and comply
with the standard (pipe thread to DIN ISO 228).
For sealing only use flat seals.

3 Flow sensor SF620A


UK

1 2 3 4

► Screw the clamp adapter (2) onto the process fitting (1).
► Insert the flow sensor (4) into the adapter.
► Set the requested installation length.
► Tighten the nut (3) (follow the instructions included with the clamp adapter).
Recommended insertion depth of the sensor: 20 ... 30 mm in the pipe. Min.
12 mm, max. to mid pipe.
Note: The sensor tip must not touch the pipe wall.

3
4 Scale drawings
Category 1/2G
SF111A
55
13 27
12

8,2
M12x1
17
SF211A
55
13 27
12

8,2
G1 4
17
SF311A
75
15 45
12
8,2
G1 2

27

4
Category 2G / Cable
SF121A
55
13 27
12

7,7
M12x1
17 UK

SF221A
55
13 27
12

7,7
G1 4
17
SF321A
75
15 45
12
7,7
G1 2

27

5
Category 2G / Plug
SF120A
52
13 27
12

7,7
M12 x1

M12x1
17
SF220A
52
13 27
12

7,7
M12 x1

G1 4
17
SF320A 72
15 45
12
7,7
M12x1

G1 2

27

6
SF620A

M12x1
217
25 146 45

7,7
20 15

10
UK

Category 2G / Ceramic units


SF223A
52
13 27
12

G1 4
8,6
17

SF323A 76,5
15 45
15,5
8,6
27

G1 2

15

7
Category 2G / ANSIB16.5 (1in; 300 lb/sq.in)
SF521A

124
19
51
89
197,5
173,5
157,6
156
32,5
24,5
12,5
10,5

18
10
7,7