100% found this document useful (1 vote)
283 views2 pages

1036330-23-351 AL 466 TV THẮNG SMAW+FCAW ISO 9606 CS 6G (H-L045)

This document is a welder's qualification test certificate for Triệu Văn Thắng. It certifies that he passed welding qualification tests on April 13, 2023 according to ISO 9606-1 2017 standards for manual and partly mechanized welding of steel pipes and plates using electrodes rated as group FM1 in the flat (H-L045) and fixed pipe positions. The certificate is valid until April 25, 2026.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
283 views2 pages

1036330-23-351 AL 466 TV THẮNG SMAW+FCAW ISO 9606 CS 6G (H-L045)

This document is a welder's qualification test certificate for Triệu Văn Thắng. It certifies that he passed welding qualification tests on April 13, 2023 according to ISO 9606-1 2017 standards for manual and partly mechanized welding of steel pipes and plates using electrodes rated as group FM1 in the flat (H-L045) and fixed pipe positions. The certificate is valid until April 25, 2026.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Certificate No:

WELDER’s QUALIFICATION TEST CERTIFICATE 1036330-23-351

Test particulars
Photo
Designation: ISO 9606-1 2017, 111+136, T, BW, FM1, B, Ø168.3*18.3 mm, H-L045,
ss, mb
WPS reference: WPS-307-1-AL
Testing standard: ISO 9606-1 2017
Employer: Alpha ECC
Welder’s name: TRIỆU VĂN THẮNG
Date of birth: 1985
ID card: 036085006153
Stamp: AL 466
Job knowledge: Acceptable Not tested

Variables Weld test details Range of approval


Welding process(es) 111 + 136, Manual + Partly mechanized 111+136, Manual +Partly mechanized
Transfer mode: NA / Globular (136) NA / All, except for short circuit transfer mode (136)
Type of current and polarity: DCEP /DCEP As per Manufacturer’s recommendation / DCEP
Shielding gas NA / C1 NA / C1
Backing gas NA NA
Leftward / rightward1 welding: NA NA
Group FM1 FM1, FM2
Filler metal Type B/B A, B, RA, RB, RC, RR, R / B, R, P, V, W, Y, Z
Designation ISO 2560 / ISO 17632 As applicable for FM1, FM2
Parent metal group(s) 1.1 As applicable
Plate (P) or pipe (T)2 T to T P & T (see below diameter limitation)
Welding position H-L045 PA, PC, PE, PF
Outside pipe diameter (mm) 168 Fixed pipe Ø ≥ 84, rotating pipe Ø ≥ 75 for PA, PC
Test piece thickness (mm) 18.3 See below
Deposit thickness (mm) 5 + 13.3 111: 3 to 10, 136: 3 & over
Joint type Butt weld CJP Butt weld, branch connection with angle ≥ 60°
Weld details ss, nb ss, nb or ss, mb or bs
Gouging No With or without gouging
Layer technique for fillet welding NA NA

Suplementary remarks:
1. Supplementary fillet weld test (completed in conjunction with a butt weld qualification): NA
2. Test caried out, place: Alpha ECC Workshop, Vung tau
3. Test caried out, date: 13 Apr 2023

Type of test Performed and accepted By Report No. Date


Visual examination Yes DNV AL-2023-WQT-VS-014 13 Apr 2023
Radiographic examination Yes Alpha NDT & DNV 2023-RT-WQT-067 18 Apr 2023

1
Only process 311
2
(T) only ISO 9606-1
Form code: WELD 271 Revision: 2022-12 www.dnv.com Page 1 of 2
Certificate No: 1036330-23-351

Chosen revalidation method, refer to ISO 9606-1, 9.3 [IACS UR W32, 6.2]

ISO 9606-1 [IACS UR W32] a) [a)] b) [b)] c) [c)]


(tick off applicable field)
Validity 25 Apr 2026

Confirmation of the validity by employer/welding coordinator/examiner or examination body for the following 6 months, refer
to ISO 9606-1, 9.2 [IACS UR W32, 6.1.1]

Date Name / position / title Signature / stamp

Issued at Vung tau on 25 Apr 2023


by: Nguyen Dang Han for DNV

Nguyen Thanh Binh


Senior Engineer

Form code: WELD 271 Revision: 2022-12 www.dnv.com Page 2 of 2

You might also like