The document describes several models of HLP Series Pressure Controllers. The controllers can be used with refrigerants, air, and liquids between -45 and 110 degrees C. They feature a novel micro switch structure for reliable operation. Models include the HLP110, HLP506, HLP530M, and HLP830HLM. Specifications include voltage, current limits, pressure ranges, and cut-off and link-up settings.

Uploaded by

yoga AGoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views1 page

STNC Pressostato PDF

The document describes several models of HLP Series Pressure Controllers. The controllers can be used with refrigerants, air, and liquids between -45 and 110 degrees C. They feature a novel micro switch structure for reliable operation. Models include the HLP110, HLP506, HLP530M, and HLP830HLM. Specifications include voltage, current limits, pressure ranges, and cut-off and link-up settings.

Uploaded by

yoga AGoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

HLP Series Pressure Controller HLP Series Pressure Controller

● Character ● Character
It is applied to the refrigerant not only using hydrogen fl uoride as medium, It is applied to the refrigerant not only using hydrogen fl uoride as medium,
But also using air and liquid (allowable liquid temperature: -45~+110 c). But also using air and liquid (allowable liquid temperature: -45~+110 c).
The novel micro switch structure will ensure reliable transform function. The novel micro switch structure will ensure reliable transform function.
The smart installation plate is applicable to different places. The smart installation plate is applicable to different places.

● HLP110 ● HLP530M Slight Moring Swith’s Date ● HLP830HLM ● HLP830M Slight Moring Swith’s Date
● HLP506
Specified VoltageV Specified VoltageV
● HLP506M A.C.125 A.C.250 A.C.125 A.C.250
Specified Electric CurentA Specified Electric CurentA
Disguide Electric Cureent 48 12 Disguide Electric Cureent 48 12
Maximum Load 48 12 Maximum Load 48 12
Winking Electric Current 288 72 Winking Electric Current 288 72

● Ordering Code ● Ordering Code

HL P 110 E HL P 830 E

Series Pressure controller Pressure Range BSP Series Pressure controller Pressure Range BSP
0.1 ~ 1.0MPa (Without E-G) 0.1 ~ 1.0MPa (Without E-G)

Single Series (MPa) Single Series (MPa)


Regulator Limits Switch Voltage Disparity Setting Up Of Leaving The Factory Regulator Limits Switch Voltage Disparity Setting Up Of Leaving The Factory
Type Type
Min Max Min Max Cuf-off[Link-up] Link-up[Cut-off] Min Max Min Max Cuf-off[Link-up] Link-up[Cut-off]
HLP110 0.1 1 0.1 0.3 0.6 0.5 low voltage end -0.07 0.6 0.06 0.4 0.3 0.2
HLP830
HLP506 -0.07 0.6 0.06 0.4 0.3 0.2 high voltage end 0.5 3 Fixed 0.3 to 0.5 2 1.5
Ⅳ HLP506M -0.07 0.6 Fixed 0.3 to 0.5 ≤ 0.4 0.3 Manual Restoration low voltage end -0.07 0.6 Fixed 0.3 to 0.5 ≤ 0.2 0.3 Manual Restoration

HLP830HLM
HLP530 0.5 3 Fixed 0.3 to 0.5 2 1.5 high voltage end 0.5 3 Fixed 0.3 to 0.5 ≤ 0.4 2 Manual Restoration
HLP530D 0.5 3 0.5 1 2 1.5 low voltage end -0.07 0.6 0.06 0.4 0.3 0.2
HLP830HM
HLP530M 0.5 3 Fixed 0.3 to 0.5 ≤ 0.4 2 Manual Restoration high voltage end 0.5 3 Fixed 0.3 to 0.5 ≤ 0.4 2 Manual Restoration
low voltage end -0.07 0.6 0.06 0.4 0.3 0.2
HLP830M
high voltage end 0.5 3 Fixed 0.3 to 0.5 ≤ 0.4 2 Manual Restoration

● Way of connection and installation


1. Way of connection: Way of connection of controller: (1) use 6x1 copper tube (It should be soft state), and then screw tight with controller’s ● Way of connection and installation
screw cap in the tube 90 cape trumpet. (2) connect with 1meter-long 3 capillary (It should be required when ordering.)(See fi gure below). 1. Way of connection: Way of connection of controller: (1) use 6x1 copper tube (It should be soft state), and then screw tight with controller’s
2. Way of installation: Way of installation of controller: (1) install with four M4 installation bore in the back of controller. (2) choose to use allpurpose screw cap in the tube 90 cape trumpet. (2) connect with 1meter-long 3 capillary (It should be required when ordering.)(See fi gure below).
installation board attachment.(See fi gure below). 2. Way of installation: Way of installation of controller: (1) install with four M4 installation bore in the back of controller. (2) choose to use allpurpose
installation board attachment.(See fi gure below).

Way of connection
Way of connection

Standard Made to order Installation size fo attachments


Standard Made to order Installation size fo attachments

431 432