DS0037Rev11 LLHP Liquid Level Switches
DS0037Rev11 LLHP Liquid Level Switches
FEATURES
• Liquid level switches that can detect almost any liquid type;
oil or water based
• Large load output; high switching currents
• Choice of threads and terminal connections
a) Before use check that the fluid in which you wish to use these devices is compatible with Stainless Steel and Polysulfone.
NOTES
OUTLINE DRAWING HOUSING SPECIFICATIONS
All dimensions shown in mm. Tolerances = ±1mm. Installation drawings and 3D (.step) files available on the
product webpage.
Cable
Housing
3/4”-16
Thread 1/2” BSPP 3/8” BSPP 1/2” NPT
UNJF
ELECTRICAL INTERFACE
Cable
Wire Designation
Red Vs
White Output
Black 0V
Flying Leads
Pin Designation
1 Vs
2 Not connected
3 0V
4 Output
Note: “X” can equal 0.5, 1.0 or 3.0 metres.
Flying Leads
Wire Designation
Red Vs
Green Output
Blue 0V
In order to suit any application, these sensors have been designed with various output circuit configurations.
4.5V—15.4VDC
10V—45VDC
L L H P X X X X X X
A 1 2 2 0 D 1
Polysulfone Push Pull Push Pull Stainless Steel -25 °C M12x1 Brad Nitrile rubber
tip High in Air Low in Air 3/8” BSPP to +80°C Harrison (IP67)
(100mA, 4.5-15.4V) (100mA, 4.5-15.4V)
3 4 5 1 I 5
Push Pull Push Pull Stainless Steel -40 °C Cable 0.5m Viton
High in Air Low in Air 1/2” BSPP to +125°C (IP67)
(800mA, 10—45V) (800mA, 10—45V)
5 6 8 L
N-Type N-Type Stainless Steel Cable 1.0m
High in Air Low in Air 1/2” NPT (IP67)
(800mA, 10—45V) (800mA, 10—45V)
7 8 B M
P-Type P-Type Stainless Steel Cable 3.0m
High in Air Low in Air 3/4”-16 UNJF (IP67)
(800mA, 10—45V) (800mA, 10—45V)
P
Flying Leads
24AWG 0.2mm
(IP65)
Note: Not all combinations are configurable and minimum order quantities (MOQs) may apply in some cases.
Please contact SST Sensing for details; email: [email protected]
CAUTION INFORMATION
Do not exceed maximum ratings and ensure sensor(s) are operated in As customer applications are outside of SST Sensing Ltd.’s control, the
accordance with their requirements. information provided is given without legal responsibility. Customers
should test under their own conditions to ensure that the equipment is
Carefully follow all wiring instructions. Incorrect wiring can cause
suitable for their intended application. Before use, check that the fluid in
permanent damage to the device.
which you wish to use these devices is compatible with Stainless Steel
SST Sensing Ltd recommend using alcohol based cleaning agents. and Polysulfone.
Do NOT use chlorinated solvents such as trichloroethane as these are
likely to attack the sensor material. For technical assistance or advice, please email:
[email protected]
Failure to comply with these instructions may result in product
damage.
General Note: SST Sensing Ltd. reserves the right to make changes to product specifications without notice or liability.
All information is subject to SST Sensing Ltd.'s own data and considered accurate at time of going to print.